manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Paradox
  6. •
  7. Control Unit
  8. •
  9. Paradox IP150 User manual

Paradox IP150 User manual

IP150-EI04 07/2019 PARADOX.COM
Description
The IP150 Internet Module is a multi-function Internet communication module that offers SWAN
connectivity or static IP address connectivity. It is fully configurable from the integrated web interface. The
IP150 provides freedom to access your system and receive push or email notifications (depending on
configuration) from anywhere around the world.
Before You Begin (Static Mode Only)
Make sure you have a web-enabled computer. You will also require the following in order to configure your
IP150 Internet Module:
• Ethernet-compatible computer with internet access (required for remote access)
• Router
• 4-pin serial cable (included)
• CAT5 Ethernet cable (maximum 90m (295 ft.), not included)
• Insite Gold app
• Paradox IP Exploring Tools Software (required for remote access)
Figure 1 - IP Communication Overview
Connecting and Installing the IP150
Figure 2 - IP150 Overview
Metal Box Installation
Figure 3 - Metal Box Installation
To connect and install the IP150:
1) Connect the 4-pin serial cable between the panel’s serial connector and the IP150’s panel connector.
2) Connect the Ethernet cable between the router and the IP150’s network connector.
3) The on-board LEDs will illuminate to indicate the IP150’s status.
4) Clip the IP150 to the top of the metal box (refer to Metal Box Installation).
LED Indicators
Reset IP150 to Default
To reset the IP150 module to its default settings, insert a pin/straightened paper clip (or similar) into the
pin hole located between the two I/O LEDs. Press down gently until you feel some resistance; hold it down
for approximately 5 seconds, release it when the I/O and RX/TX LEDs start flashing, and then press it
again. The I/O and RX/TX LEDs will remain lit during the reset.
IP Reporting
When using IP reporting, the IP150 has the ability to poll the monitoring station. To enable IP reporting, the
IP150 must first be registered to the monitoring station’s IP Receiver (IPR512) or to the IPRS-7 software.
Telephone reporting can be used in conjunction with, or as a backup to IP reporting. Before registering the
IP150, the following information must be obtained from the monitoring station:
• Account number(s) - One account number for each partition used. IP/GPRS reporting uses a different
set of account numbers than those used for dialer reporting.
• IP address(es) - (12-digit number e.g., for 195.4.8.250 you must enter 195.004.008.250). The IP
address(es) indicate(s) which of the monitoring station’s IP Receivers will be used for IP reporting.
• IP port(s) (5-digit number; for 4-digit numbers, enter 0 before the first digit). The IP port refers to the
port used by the monitoring station’s IP Receiver.
• Receiver password(s) (up to 32-digits). The receiver password is used to encrypt the IP150
registration process.
• Security profile(s) (2-digit number). The security profile indicates how frequently the monitoring station
is polled by the IP150. Security profile numbers and polling frequency are defined by the monitoring
station.
Setting Up IP Reporting
1) Ensure the panel’s report code format is set to Ademco Contact ID:
MG/SP: section [810]
EVO: section [3070]
2) Enter the IP reporting account numbers (one for each partition):
MG/SP: section [918] / [919]
EVO: section [2976] to [2983]
Please make sure that reporting codes are programmed in the panel, refer to the corresponding
Programming Guide for more details.
In the General IP Options section, set up IP line monitoring options and dialer options, and ensure IP
reporting is enabled (refer to the following tables).
MG/SP: section [806]
EVO: section [2975]
4) Enter the monitoring station’s IP address(es), IP port(s), receiver password(s), and security profile(s)
(information must be obtained from the monitoring station).
5) Register the IP150 module with the monitoring station. To register, enter the sections below and press
[ARM]. The registration status is displayed as well as any registration errors.
NOTES:
An IP150 used with an MG/SP system will always poll using the partition 1 IP account number. When
using an EVO system, the partition 1 IP account is used by default, but can be defined in section [3020].
All reported system events will originate from the partition selected in this section.
Remote Access (Static Mode Only)
In order to configure your system for remote access you will need IP Exploring Tools, a web browser and
access to your router. The following steps will guide you in setting up remote access.
Step 1: Setting up the Router
This step allows you to set up the router so that the IP150 module can function properly.
1) Ensure the router is connected properly as indicated in the router’s instructions.
2) Access your router’s configuration page. Refer to your router’s manual for the exact procedure. In
most cases, this is done by entering the router’s static IP address in the address bar of your Web
browser. For this instance, we will use 192.168.1.1 as an example for the router’s IP address that may
be indicated in the router’s instructions or on a sticker on the router. Enter the monitoring station’s IP
3) In the router’s configuration page, check the DHCP settings (screen shot below may differ depending
on type of router used).
IP150
Internet Module
Installation Manual
Version 4.40 and higher
Left Side
View
Right Side
View
Front
View
LED Description
User On when a user is connected via Insite Gold/BabyWare/InField.
Internet
LED Status SWAN
On Connected
Flashing Trying to connect
Off No connection
Link
Solid Yellow = Valid Link @ 10Mbps
Solid Green = Valid Link @ 100Mbps
LED will flash according to data traffic
Flashing Yellow/Green = DHCP trouble
RX/TX
On after first successful communication exchange
Flashes when data is transmitted or received through/from panel
Off when no connection has been established
I/O 1 On when activated
I/O 2 On when activated
IP Line Monitoring Options
[5] [6]
Off Off Disabled
Off On When disarmed: Trouble only
When armed: Trouble only
On Off When disarmed: Trouble only
When armed: Audible alarm
On On Silent alarm becomes audible alarm
OFF ON
[7] Use dialer reporting
(telephone)
As backup for IP/GPRS
reporting
In addition to IP
reporting
[8] IP/GPRS reporting Disabled Enabled
IP Line Monitoring Options
[5] [6]
Off Off Disabled
Off On When disarmed: Trouble only
When armed: Audible alarm
On Off When disarmed: Trouble only (default)
When armed: Trouble only
On On Silent alarm becomes audible alarm
OFF ON
[7] Use dialer reporting
(telephone)
As backup for IP/GPRS
reporting
In addition to IP
reporting
[8] IP/GPRS reporting Disabled Enabled
MG/SP Sections
IP Receiver #1 #2 Backup
IP Address1 [929] [936] [943]
IP Port1 [930] [937] [944]
IP Address2 [931] [938] [945]
IP Port2 [932] [939] [946]
IP Password [933] [940] [947]
IP Profile [934] [941] [948]
EVO Sections
IP Receiver #1 #2 #3 #4
IP Address1 [2984] [2986] [2988] [2990]
IP Port1
IP Address2
IP Port2
IP Password
IP Profile
MG/SP Registration
IP Receiver # #1 #2 Backup
Register/Status [935] [942] [949]
EVO Registration
IP Receiver # #1 #2 #3 #4
Register/Status [2985] [2987] [2989] [2991]
IP150-EI04 07/2019 PARADOX.COM
Figure 4 - DHCP Settings
If DHCP is enabled, verify that the IP address range leaves at least one IP address available outside of
the range. The range shown in the above example would leave addresses 2 to 4 and 101 to 254 available
(all the numbers in an IP address are between 1 and 254). Record one of the addresses outside the
DHCP range as the one you will use for the IP150. If DHCP is disabled, the IP150 will use the default
address of 192.168.1.250. It is possible to change that address if needed using the Paradox IP Exploring
To o l s s o ft w a r e.
4) In the router’s configuration page, go to the Port Range Forwarding section (also known as “port
mapping” or “port redirection”). Add a service/item, set the Port to 80 and enter the static IP address
selected in the previous step for the IP module. If port 80 is already used, you can use another one,
such as 81 or 82 but you will have to modify the IP150’s settings in step 2. Some Internet Service
Providers block port 80, therefore the IP150 may function locally using port 80 but not over the
Internet. If this is the case, change the port to another number. Repeat this step for port 10 000
(screenshot below may differ depending on type of router used). Also, repeat this step for port 443 if
using a secure connection (https).
Figure 5 - Port Range Forwarding
Step 2: Configuring the IP150
1) Using a computer connected to the same network as the IP150, open the Paradox IP Exploring Tools.
2) Click Find It. Your IP150 appears in the list.
Figure 6 - IP Exploring Tools
3) Right-click your IP150 and select Module setup, refer to screen shot below. Enter the static IP
address you recorded in Step 1.3 or modify the address so that it corresponds to the one you have
selected for the IP150. Enter the IP150’s password (default: paradox) and click OK. If it indicates that
the IP address is already used, change it to another and modify it in the Port Forwarding of the router
(Step 1.4) and go back to Step 2.1.
4) Set any additional information such as port, subnet mask, etc. To find this information, click Start >
Programs > Accessories > Command Prompt. Enter command: IPCONFIG /ALL (with space after
IPCONFIG).
NOTE: For increased communication security, please change the default PC password and Panel ID in
the control panel. Also, note that the IP150 supports SMTP/ESMTP/SSL/TLS protocols.
Figure 7 - Module Setup
Step 3: Using a Web Browser to Access the System
Once the module is configured, it can be accessed either from the local network or through the internet
using the alarm system’s master code.
On-Site Access:
1) Enter the IP address assigned to the IP150 in the address bar of your Web browser. If you have used
a port other than port 80, you must add [: port number] at the end. (For example, if the port used is 81,
the IP address entered should look like this: http://192.168.1.250:81). For a secure connection, make
sure to write “https://...etc.”.
or
Use the Paradox IP Exploring Tools software, click Refresh and double-click on your IP150 in the list.
2) Enter your alarm system’s User Code.
WARNING: A pop-up warning you that the website’s certificate is not secure may occur. This is
acceptable, click to continue.
Inputs and Outputs Connections
To configure your I/O terminals please refer to the IP150 Programming Guide. Refer to figures 8 and 9 for
examples of input and output connections.
Technical Specifications
The following table provides a listing of the technical specifications for the IP150 Internet Module.
Figure 8 - Input Connection Example Figure 9 - Output Connection Example
Specification Description
Panel
Compatibility
Any Digiplex EVO panel (V2.02 for IP reporting)
Any Spectra SP series panel (V3.42 for IP reporting)
Any MG5000 / MG5050 panel (V4.0 for IP reporting)
Encryption AES 256-bit, MD5 and RC4
Current
Consumption
100mA
Input Voltage 13.8VDC, supplied by the panel serial port
Enclosure
Dimensions
10.9cm x 2.7cm x 2.2cm (4.3in x 1.1in x 0.9in)
Approvals CE, EN 50136-1, EN 50136-2 SP5, EN 50131-10 Grade 3, Class II
Warranty
For complete warranty information on this product, please refer to the Limited Warranty Statement found on the Web site
www.paradox.com/Terms. or contact your local distributor. Specifications may change without prior notice.
Patents
US, Canadian and international patents may apply. Paradox is a trademark or registered
trademarks of Paradox Security Systems (Bahamas) Ltd. © 2019 Paradox Security Systems
(Bahamas) Ltd. All rights reserved. www.paradox.com

Other manuals for IP150

5

Other Paradox Control Unit manuals

Paradox PCS300 User manual

Paradox

Paradox PCS300 User manual

Paradox ZX82 User manual

Paradox

Paradox ZX82 User manual

Paradox IP180 User manual

Paradox

Paradox IP180 User manual

Paradox PCS265 User manual

Paradox

Paradox PCS265 User manual

Paradox ZX16D User manual

Paradox

Paradox ZX16D User manual

Paradox PCS265LTE Installation guide

Paradox

Paradox PCS265LTE Installation guide

Paradox Digiplex EVO EVO192 V7.11 Operating instructions

Paradox

Paradox Digiplex EVO EVO192 V7.11 Operating instructions

Paradox Spectra 1759EX V1.0 User manual

Paradox

Paradox Spectra 1759EX V1.0 User manual

Paradox IP150 Operating instructions

Paradox

Paradox IP150 Operating instructions

Paradox Digiplex EVO ZX8D User manual

Paradox

Paradox Digiplex EVO ZX8D User manual

Paradox IP150+ User manual

Paradox

Paradox IP150+ User manual

Paradox MG-RCV3 User manual

Paradox

Paradox MG-RCV3 User manual

Paradox MG-RCV3 User manual

Paradox

Paradox MG-RCV3 User manual

Paradox ZX32D User manual

Paradox

Paradox ZX32D User manual

Paradox IMPERIAL DIGIPLEX EVO ACM24D User manual

Paradox

Paradox IMPERIAL DIGIPLEX EVO ACM24D User manual

Paradox ZX82 User manual

Paradox

Paradox ZX82 User manual

Paradox VDMP3 User manual

Paradox

Paradox VDMP3 User manual

Paradox PGM82 User manual

Paradox

Paradox PGM82 User manual

Paradox MAGELLAN RTX3 V1.5 User manual

Paradox

Paradox MAGELLAN RTX3 V1.5 User manual

Paradox APR3-HUB2 User manual

Paradox

Paradox APR3-HUB2 User manual

Paradox PCS265 LTE Installation guide

Paradox

Paradox PCS265 LTE Installation guide

Paradox IP150+ User manual

Paradox

Paradox IP150+ User manual

Paradox IP150 User manual

Paradox

Paradox IP150 User manual

Paradox RPT1+ User manual

Paradox

Paradox RPT1+ User manual

Popular Control Unit manuals by other brands

Leviton MC 7516 user guide

Leviton

Leviton MC 7516 user guide

Teleflex Marine KE-4 Installation/operation instruction manual

Teleflex Marine

Teleflex Marine KE-4 Installation/operation instruction manual

ElMod Fusion ECO Detailed installation instructions and user manual

ElMod

ElMod Fusion ECO Detailed installation instructions and user manual

GEM 532Z operating instructions

GEM

GEM 532Z operating instructions

Kemper Figure 150 6G Installation and operating instructions

Kemper

Kemper Figure 150 6G Installation and operating instructions

Siemens SIMATIC ET 200AL manual

Siemens

Siemens SIMATIC ET 200AL manual

Symetrix Composer v7.0 manual

Symetrix

Symetrix Composer v7.0 manual

DEFA homeCLU installation manual

DEFA

DEFA homeCLU installation manual

rada Pulse Series product manual

rada

rada Pulse Series product manual

Sanhua RFGB Series instructions

Sanhua

Sanhua RFGB Series instructions

Orthofix SFS manual

Orthofix

Orthofix SFS manual

hager RTN710X manual

hager

hager RTN710X manual

Domestia DMC-012-003 S manual

Domestia

Domestia DMC-012-003 S manual

ATEN CN8000 user manual

ATEN

ATEN CN8000 user manual

Intermatic P1353ME instruction manual

Intermatic

Intermatic P1353ME instruction manual

Grundfos CIM 150 Functional profile and user manual

Grundfos

Grundfos CIM 150 Functional profile and user manual

KLC Disco 240 user manual

KLC

KLC Disco 240 user manual

Britex FFV-E45 installation guide

Britex

Britex FFV-E45 installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.