Size Ordering no. Mounting bolt Torque
TDP/TEP025 BK504 4 pcs. M12x100 108 Nm
TDP/TEP032 BK529 4 pcs. M16x100 264 Nm
TDP/TEP040 BK481 4 pcs. M20x110 517 Nm
TDP/TEP050 BK481 4 pcs. M20x110 517 Nm
TDP/TEP063 BK518 4 pcs. M30x160 1775 Nm
TDP/TEP080 BK530 8 pcs. M24x160 890 Nm
TDP/TEP100 BK531 8 pcs. M30x150 1775 Nm
• Remove protection plate from the valve mount-
ing surface
• Check the proper position of the valve ports
and the O-rings.
• Mountingbolts:usepropertyclass12.9,ISO4762
Insufcient condition of the valve mounting
surface might create malfunction!
Incorrect mounting resp. bolt torque may
result in abrupt leakage of hydraulic uid on
the valve ports.
Y-port has always to be tied directly and
separately to tank!
Limits of Use
The valve may be operated within the determined
limits only. Please refer to the “technical data“
section as well as to the “characteristic curves“
in the Parker catalogue HY11-3500/UK "Hydraulic
Valves Industrial Standard".
Follow the environmental conditions! Unal-
lowable temperatures, shock load, aggresive
chemicals exposure, radiation exposure,
illegal electromagnetic emissions may result
in operating trouble and may lead to failure!
Follow the operating limits listed in the
“specications“ table!
4. Mounting / Installation
Scope of Supply
Please check immediately after receiving the valve,
if the content is matching with the specied scope
of supply. The delivery includes:
• valve
• operation manual
The central connector has to be ordered separately
and is not included in the delivery.
Please check the delivery immediately after
receiving the shipment for apparent damages
due to shipping. Report shipment losses at
once to the carrier and the supplier!
Mounting
• Compare valve type (located on the name plate)
with part list resp. circuit diagram.
• The valve may be mounted x or movable in
any direction.
• Verify the mounting surface for the valve. Un-
eveness of 0.01 mm/100 mm, surface nish of
6.3 µm are tolerable values.
Keep valve mounting surface and work
environment clean!
Available Bolt Kits
Pressure Fluids
The following rules applies for the operation with
various pressure uids:
This information serves for orientation and
does not substitute user tests among the
particular operating conditions. Particularly
no liabiliy for media compatibility may be
derived out of it.
Mineral oil: usable without restriction.
HFC: choose the right seal option for series TEP.
Choose seal option code N for series TDP.
HFA Oil-in-water emulsion
HFB Water-in-oil emulsion
HFD Unhydrous uids (Phosphor-Ester)
For operation with the following pressure uids
please consult Parker:
For detailed information concerning pressure
uids note VDMA-document 24317 as well
as DIN 51524 & 51502.
Special gaskets may be available depending on
the utilized uid.
In case of doubt please consult Parker.