manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Parker
  6. •
  7. Measuring Instrument
  8. •
  9. Parker Porter F65 User manual

Parker Porter F65 User manual

This manual suits for next models

1

Other Parker Measuring Instrument manuals

Parker Digital MXR-D 4065D User manual

Parker

Parker Digital MXR-D 4065D User manual

Parker BD15 Series Installation and maintenance instructions

Parker

Parker BD15 Series Installation and maintenance instructions

Parker SensoControl Serviceman SCM-150-1-01 Installation guide

Parker

Parker SensoControl Serviceman SCM-150-1-01 Installation guide

Parker PFM1 Series User manual

Parker

Parker PFM1 Series User manual

Parker ServiceJunior SCJN Series User manual

Parker

Parker ServiceJunior SCJN Series User manual

Parker DIGI+ User manual

Parker

Parker DIGI+ User manual

Parker icountBS Series User manual

Parker

Parker icountBS Series User manual

Parker SensoControl Serviceman SCM-150 Series User manual

Parker

Parker SensoControl Serviceman SCM-150 Series User manual

Parker SciPres II Assembly instructions

Parker

Parker SciPres II Assembly instructions

Parker OSP-P User manual

Parker

Parker OSP-P User manual

Parker SensoControl ServiceJunior User manual

Parker

Parker SensoControl ServiceJunior User manual

Parker SensoControl ServiceJunior Series User manual

Parker

Parker SensoControl ServiceJunior Series User manual

Parker PMS User manual

Parker

Parker PMS User manual

Parker Service Master CONNECT User manual

Parker

Parker Service Master CONNECT User manual

Parker RK 11-1669 User manual

Parker

Parker RK 11-1669 User manual

Parker SCPSi User manual

Parker

Parker SCPSi User manual

Parker icountACM202024 User manual

Parker

Parker icountACM202024 User manual

Parker Serviceman Plus User manual

Parker

Parker Serviceman Plus User manual

Parker DPIT1 VS08MDC1 Series User manual

Parker

Parker DPIT1 VS08MDC1 Series User manual

Parker icountOS User manual

Parker

Parker icountOS User manual

Parker C3000 Instruction Manual

Parker

Parker C3000 Instruction Manual

Parker XRF User manual

Parker

Parker XRF User manual

Parker 023-064 Series User manual

Parker

Parker 023-064 Series User manual

Parker SensoControl User manual

Parker

Parker SensoControl User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Description
The Porter Series F65 and F150 Flowmeters are variable area, low flow
rate indicators for metering liquids or gases. The meter consists of a
one-piece forged aluminum body with a tapered, fluted glass metering
tube and a ball float. A wrap around window shield allows 180° visibility
of the metering tube and scale. The flowmeter may be supplied with
our without a control valve and is available with stainless steel or brass
inserts (wetted parts) when the meter is used for corrosive service.
Specifications
Warning: Do not operate this flowmeter in excess of maximum
pressure and temperature limits. Exceeding these limits may
result in serious personal injury.
Maximum Pressure Limits
200 psig
Maximum Temperature Limits
160°F (71°C) w/Neoprene Packing and Buna-N
O-rings.
200°F (94°C) w/Viton Packing and Viton O-rings
Accuracy
Series F65: +/-10% Full Scale
Series F150: +/-5% Full Scale
Repeatability
Series F65: +/-0.5% Full Scale
Series F150: +/-0.25% Full Scale
Scale
Series F65: 0-65 mm (Direct reading scales optional)
Series F150: 0-150 mm (Direct reading scales optional)
Connections
1/8” Female NPT threaded adaptor with panel mounting nuts. Other
process connections available (consult factory).
Control Valve (Optional)
Standard Cartridge Valve (SC)
High Resolution Control Valve (HR)
Operation
Slowly open the flow control valve until the desired flow rate is indicated
on the flowmeter. If equipped with integral control valve, turn counter-
clockwise to open. The center of the ball float is used as the reference
mark when reading the scale.
Installation
The flowmeter may be panel mounted and secured with the mounting nuts
provided on the inlet and outlet connection fittings. The meter must be
mounted in a vertical position to assure accuracy. To panel mount Series
F65 meters, drill two 9/16” holes on 4-1/2” centers. For Series F150, drill
two 9/16” holes on 8-13/16” centers.
Connections are horizontal, 1/8” female NPT. Connect the upstream sup-
ply line to the inlet (bottom) connection on the meter, and connect the
downstream line to the outlet (top) connection. Make certain connections
are clean and tight, but do not over tighten. Leak check prior to use.
If the metered fluid contains contaminants, it is highly recommended an
in-line filter be installed upstream of the meter to assure proper operation
and accuracy.
INSTRUCTIONS
FORGED BODY
FLOWMETERS
Disassembly and Cleaning
The flowmeter may easily be disassembled for cleaning or parts replace-
ment without removing it from the line. If the inside of the metering tube
requires cleaning, the tube may be removed and flushed or swabbed with a
suitable cleaning agent.
a. Turn off the flow to the flowmeter.
b. Squeeze sides of plastic front shield and remove.
c. While supporting the glass tube, use a 5/32” Allen wrench and turn
counterclockwise to back out the seal spindle. Carefully remove tube
and float assembly. Remove tube seat packings if necessary.
d. On all aluminum body meters, seal spindle may be removed by turning
counterclockwise. On meters with stainless steel or brass wetted parts,
turn seal spindle clockwise to remove through tube portion of meter.
e. If necessary, remove control valve by turning counterclockwise with an
open-end wrench. Depending upon the width of the wrench, it may be
necessary to remove the knob.
Reassembly
a. Make certain all parts are clean.
b. When installing tube seat packings, stainless steel guide should pro-
trude approximately 1/16” above the surface of the packing.
c. Install tube assembly and carefully tighten seal spindle by turning
clockwise. On flowmeters with brass and stainless steel wetted parts,
carefully tighten seal spindle by turning counterclockwise. When tight-
ening, check to make sure metering tube is properly seated on packing
and not contacting any metal part of the meter body or seal spindle.
d. Replace control valve and front shield. Leak check before resuming
Return Shipments
If a flowmeter is to be returned to the manufacturer for any reason, con-
tact Porter for a return authorization number. This number must be refer-
enced on the return shipment. Items returned must be properly packaged
and shipped prepaid. Units exposed to hazardous gases or liquids must
be accompanied by a Declaration of Contamination Form (FM-768).
A B C D E
F65 5 9/16" 3 1/4" 1 3/16" 1 1/8" 4 1/2"
F150 9 15/16" 7 9/16" 1 3/8" 1 1/4" 8 13/16"
Dimensions shown are in Inches
FM-215 Rev. E 10/07
FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND /OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN
CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further
investigation by users having technical expertise. It is important that you analyze all aspects of your application and review the information concerning the product or
system in the current product catalog. Due to the variety of operating conditions and applications for these products and systems and assuring that all performance,
safety and warning requirements of the application are met.
The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin
Corporation and its subsidiaries at any time without notice.
"HR" High Resolution Control
Valve
Needle
Size Brass
with Buna N
Stainless
Steel
with
0 HR-0-B HR-0-S
1 HR-1-B HR-1-S
2 HR-2-B HR-2-S
3 HR-3-B HR-3-S
4 HR-4-B HR-4-S
5 HR-5-B HR-5-S
6 HR-6-B HR-6-S
Standard Cartridge Valve
Needle
Size Aluminum
with Buna N
Brass
with
Buna N
Stainless Steel
with Viton®
1 SC-1-A SC-1-B SC-1-S
2 SC-2-A SC-2-B SC-2-S
3 SC-3-A SC-3-B SC-3-S
Forged Body Flowmeters
Series F65 and F150
Ref. Description Aluminum
Series
F65, F150
Brass &
Stainless Steel
Series
F65 & F150
Material
1 Tube and Float
Assembly As Required As Required
2 Tube Seat Packing
w/Guide As Required As Required
3 Seal Spindle A-174-AL2
N/A
N/A
N/A
A-823-BR1
A-823-SS1
Aluminum
Plated Brass
St. Stl.
4
O-ring (lower)
013
111
111
PB-102-8-BN
N/A
N/A
N/A
PB-102-9-BN
PB-102-39-VT
Buna N
Buna N
Viton®
5
O-ring (upper)
111
010
010
PB-102-9-BN
N/A
N/A
N/A
PB-102-6-BN
PB-102-23-VT
Buna N
Buna N
Viton®
6
O-ring
009
010
010
PB-102-5-BN
N/A
N/A
N/A
PB-102-6-BN
PB-102-23-VT
Buna N
Buna N
Viton®
7 Connector Adaptor A-808-001
N/A
N/A
N/A
A-1120-BR1
A-1120-SS1
Aluminum
Plated Brass
St. Stl.
8 Panel Mounting
Nut PA-267-1-ST2 PA-267-1-ST2 Steel
9 Window Shield
Series F65
Series F150
PB-146-01LX
PB-146-02LX
PB-146-01LX
PB-146-02LX
Lexan
Lexan
10 O-ring
010
PB-102-6-BN
N/A
PB-102-6-BN
PB-102-23-VT
Buna-N
Viton ®
11 O-ring
011
PB-102-7-BN
N/A
PB-102-7-BN
PB-102-24-VT
Buna-N
Viton®
12 Control Valve
Assembly See Valve List See Valve List
Viton® - DuPont Dow Elastomers LLC
Replacement Parts