Ultrasonic sensor UC2000-L2-E6-V15-Y277310
Release date: 2016-02-16 09:15 Date of issue: 2016-02-16 277310_eng.xml
Technical data
General specifications
Sensing range 60 ... 2000 mm
Adjustment range 80 ... 2000 mm
Dead band 0 ... 60 mm
Standard target plate 100 mm x 100 mm
Transducer frequency approx. 175 kHz
Response delay ≤100 ms
Indicators/operating means
LED green Operating display
LED yellow 1 switching state switch output 1
LED yellow 2 switching state switch output 2
LED red error
Electrical specifications
Operating voltage UB10 ... 30 V DC , ripple 10 %SS
No-load supply current I0≤50 mA
Interface
Interface type Serial interface (programming adapter required)
9600 BPS, no parity, 8 data bits, 1 stop bit
Input/Output
Input/output type 1 synchronization connection, bidirectional
0 Level 0 ... 1 V
1 Level 4 V ... UB
Input impedance > 12 kΩ
Output rated operating current < 12 mA
Pulse length 0.5 ... 300 ms (level 1)
Pulse interval ≥33 ms (level 0)
Synchronization frequency
Common mode operation ≤30 Hz
Multiplex operation ≤33 Hz / n , n = number of sensors , n ≤10
(factory setting: n = 5 )
Output
Output type 2 switch outputs PNP, NO/NC, programmable
Rated operating current Ie200 mA , short-circuit/overload protected
Voltage drop Ud≤2 V
Repeat accuracy ≤0.1 % of full-scale value
Switching frequency f ≤5 Hz
Range hysteresis H programmable , preset to 1 mm
Temperature influence < 1.5 % of full-scale value
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type Connector M12 x 1 , 5-pin
Degree of protection IP67
Material
Housing PA-GF35
Transducer epoxy resin/hollow glass sphere mixture; polyurethane foam
Mass 115 g
Factory settings
Output 1 Switch point A1: 600 mm
output function: Switch point operation mode
output behavior: NO contact
Output 2 Switch point A2: 850 mm
output function: Switch point operation mode
output behavior: NO contact
Beam width wide
General information
Supplementary information Switch settings of the external programming adapter:
"output load": pull-down
"output logic": inv
Compliance with standards and
directives
Standard conformity
Standards EN 60947-5-2:2007 + A1:2012
IEC 60947-5-2:2007 + A1:2012
Approvals and certificates
UL approval cULus Listed, General Purpose
CSA approval cCSAus Listed, General Purpose
CCC approval CCC approval / marking not required for products rated
≤36 V
Model Number
UC2000-L2-E6-V15-Y277310
Single head system
Features
• Sensor head bidirectional and ro-
tatable
• Function indicators visible from all
directions
• Selectable sound lobe width
• Programmable
• Rugged metal base
Diagrams
0 400 800 1200 1600 2000 2400 2800 32003200 3600 4000
700
600
500
400
300
200
100
0
-100
-200
-300
-400
-500
-600
-700
X
Y
Characteristic response curve
Distance X [mm]
Distance Y [mm]
flat surface 100 mm x 100 mm
round bar, Ø 25 mm
wide sound lobe
narrow sound lobe
Ultrasonic sensor UC2000-L2-E6-V15-Y277310
2
Release date: 2016-02-16 09:15 Date of issue: 2016-02-16 277310_eng.xml
Germany: +49 621 776 4411Pepperl+Fuchs Group
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
USA: +1 330 486 0001 Singapore: +65 6779 9091
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com [email protected].com
fa-info@de.pepperl-fuchs.com
Dimensions
Electrical Connection
Pinout
LED yeLED gnLED ye
LED gn
3
28
67
40
40
46
7
M12 x 1
28
8ø 5.5
20
30
60
T1T2
out 1 pwr/out 2
Synchronization
Switch output 1
Switch output 2
1
5
2
3
4
L+
L-
1
3
4
5
2
1 BN
2 WH
3 BU
4 BK
5 GY
Wire colors in accordance with EN 60947-5-2
(brown)
(white)
(blue)
(black)
(gray)
Ultrasonic sensor UC2000-L2-E6-V15-Y277310
3
Release date: 2016-02-16 09:15 Date of issue: 2016-02-16 277310_eng.xml
Germany: +49 621 776 4411Pepperl+Fuchs Group
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
USA: +1 330 486 0001 Singapore: +65 6779 9091
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com [email protected].com
fa-info@de.pepperl-fuchs.com
Description of Sensor Functions
Programming procedure
The sensor features two outputs with two programmable switch points, each (for a total of 4). Programming the switch points and the operating mode can be done in two
different ways:
- via the sensor’s programming buttons
- via the serial interface, which requires an external interface adapter
The procedure for programming via the sensor's programming buttons is described below. For programming using the serial interface, please refer to the software manual.
Switch points and operating modes of each output can be programmed independently without influencing each other.
Note:
- Programming is enabled for 5 minutes after power-on. After 5 minutes without programming activity the programming feature will be locked.
- During any programming step it is possible to leave the programming routine without changing the sensor settings by pressing the currently used programming button
for 10 s.
Programming the Switch Points
Notes:
- The description below leads you through programming output 1’s switch points. The procedure for output 2 is exactly the same with the only difference, being to use the
Programming Button T2.
- If the red LED flashes during the programming procedure, it indicates uncertain target detection. In this case, please correct the target alignment until the yellow LED
flashes. The new settings will only be stored in the sensor’s memory if the yellow LED flashes.
Programming the Near Switch Point
1. Place the target at the desired near switch point position
2. Press Programming Button T1 for 2 s (corresponding yellow LED flashes)
3. Press Programming Button T1 briefly (green LED flashes three times for confirmation). The sensor returns to normal operation.
Programming of the Far Switch Point
1. Place the target at the desired far switch point position
2. Press Programming Button T1 for 2 s (corresponding yellow LED flashes)
3. Press Programming Button T1 for 2 s (green LED flashes three times for confirmation). The sensor returns to normal operation.
Programming Modes of Operation
Note:
The description below leads you through programming of the modes of operation for output 1. The procedure for output 2 is exactly the same with the only difference,being to
use Programming Button T2.
The sensor provides a three step routine to program the modes of operation. In this routine you can program:
1. Output function
2. Output behavior
3. Beam width
Programming the modes is carried out sequentially. To toggle from one mode to the next, press the Programming button for 2 s.
Press Programming Button T1 for 5 s to enter the operating modes programming routine.
Programming the output function
1. The green LED flashes. The number of flashes indicates the current output function:
single flash: Switch point output function
double flash: Window output function
triple flash: Hysteresis output function.
2. Press Programming Button T1 briefly to toggle sequentially through these output functions and select the desired mode.
3. Press Programming Button T1 for 2 s to save and enter the programming routine for output behavior
Programming the output behavior
1. The yellow LED flashes. The number of flashes indicates the current output behavior:
single flash: Normally Open (NO)
double flash: Normally Closed (NC).
2. Press Programming Button T1 briefly to toggle sequentially through these output behaviors and select the desired mode.
3. Press Programming Button T1 for 2 s to save and enter the programming routine for beam width.
Programming the beam width
1. The red LED flashes. The number of flashes indicates the current beam width setting:
single flash: narrow
Accessories
UC-PROG1-USB
Programming adapter
PACTware 3.6
FDT Framework
PACTware 4.X
FDT Framework
Ultraschall-Sensoren DTM
DTM devices for communication with cube style and UMC... sensors
V15-G-2M-PVC
Female cordset, M12, 5-pin, PVC cable
Microsoft .NET
Ultrasonic sensor UC2000-L2-E6-V15-Y277310
4
Release date: 2016-02-16 09:15 Date of issue: 2016-02-16 277310_eng.xml
Germany: +49 621 776 4411Pepperl+Fuchs Group
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
USA: +1 330 486 0001 Singapore: +65 6779 9091
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com [email protected].com
fa-info@de.pepperl-fuchs.com
double flash: medium
triple flash: wide.
2. Press Programming Button T1 briefly to toggle sequentially through these beam shapes.
3. Press Programming Button T1 for 2 s to save and exit the operating modes programming routine.
Note:
Independently programming the beam width for each individual output is not possible. The last programmed beam width is valid for both outputs. It doesn’t matter which Pro-
gramming Button is used.
Reset Sensor to Factory Settings
The sensor has a feature to reset to factory settings
1. Disconnect the sensor from power supply
2. Press and hold one of the Programming Buttons T1 or T2
3. Connect Sensor to power supply (red and yellow LED flash simultaneously for 5 s then green and yellow LED flash simultaneously)
4. Release Programming Button
The sensor now operates with default factory settings.
Factory settings
See technical data.
Display
The sensor is provided with LEDs to indicate various conditions.
#
*) off if yellow LED out2 is on
Synchronization
This sensor features a synchronization input for suppressing ultrasonic mutual interference ("cross talk"). If this input is not connected, the sensor will operate freewheeling
using internally generated clock pulses. It can be synchronized by applying an external square wave or by means of appropriate programming via the serial interface. Each
falling edge of the synchronization pulse triggers transmission of a single ultrasonic pulse. If the synchronization signal remains low for ≥ 1 second, the sensor will revert to
normal operating mode. Normal operating mode can also be activated by opening the signal connection to the synchronization input.(See note below)
If the synchronization input goes to a high level for > 1 second, the sensor will switch to standby mode, indicated by the green LED. In this mode, the output(s) will remain in
the last valid output state. When using the external synchronization feature, please refer to the software description.
Note:
If the option for synchronization is not used, the synchronization input has to be connected to ground (0V) or the sensor has to be operated via a V1 cordset (4-pin).
The synchronization function cannot be activated during programming mode and vice versa.
The following synchronization modes are possible:
1. Several sensors (max. number see technical data) can be synchronized together by interconnecting their respective synchronization inputs. In this case, each sensor
alternately transmits ultrasonic pulses in a self multiplexing mode. No two sensors will transmit pulses at the same time. (See note below)
2. Several sensors (max. number see technical data) can be synchronized together by interconnecting their respective synchronization inputs. Due to programming via the
sensors interface one sensor acts as a master device, all the others as slave devices. (see description of the interface) In this master / slave mode the sensors are triggered
in parallel and are synchronized by a common synchronization pulse, provided by the master device.
3. Multiple sensors can be controlled by the same external synchronization signal. In this mode the sensors are triggered in parallel and are synchronized by a common
external synchronization pulse. All sensors must be parameterized for external synchronization by means of the sensor interface. See software description.
4. A separate synchronization pulse can be sent to each individual sensor. In this mode the sensors operate in external multiplex mode. (See note below). All sensors must
be parameterized for external synchronization by means of the sensor interface. See software description.
5. A high level (+UB) or a low level (-UB)on the synchronization input switches the sensor to standby mode if it is parameterized for external synchronization.
Note:
Sensor response times will increase proportionally to the number of sensors that are in the synchronization string. This is a result of the multiplexing of the ultrasonic transmit
and receive signal and the resulting increase in the measurement cycle time.
Note:
The sensors syncronization input delivers an output current in case of low level and burdens with its input impedance in case of high level. Please pay attention that the syn-
chronizing device needs to have that driver capability:
driver current against +UB≥n * high-level/input impedance (n = number of sensors to be synchronized)
driver current against 0V ≥n * output current (n = number of sensors to be synchronized).
Green LED Yellow LED out1 / out2 Red LED
During Normal operation
Proper operation
Interference (e.g. compressed air)
On*)
Off
Switching state
output 1 / output 2
remains in previous state
Off
On
During Switch Point Programming
Object detected
No object detected
Confirmation after Programming
Programming failed warning
Off
Off
Triple flashing
Off
Flashing
Off
Off
Off
Off
Flashing
Off
Triple flashing
During Sensor Mode Programming
Programming the output function
Programming the output behaviour
Programming the beam width
Flashing
Off
Off
Off
Flashing
Off
Off
Off
Flashing

Other Pepperl+Fuchs Accessories manuals

Pepperl+Fuchs UC-18GS Series Installation and operation manual

Pepperl+Fuchs

Pepperl+Fuchs UC-18GS Series Installation and operation manual

Pepperl+Fuchs NVD-111 User manual

Pepperl+Fuchs

Pepperl+Fuchs NVD-111 User manual

Pepperl+Fuchs UC4000-L2M-E6-T-2M User manual

Pepperl+Fuchs

Pepperl+Fuchs UC4000-L2M-E6-T-2M User manual

Pepperl+Fuchs UC4000-L2-E5-V15-Y70120089 User manual

Pepperl+Fuchs

Pepperl+Fuchs UC4000-L2-E5-V15-Y70120089 User manual

Pepperl+Fuchs SmartRunner 3-D ToF User manual

Pepperl+Fuchs

Pepperl+Fuchs SmartRunner 3-D ToF User manual

Pepperl+Fuchs 2-D LiDAR R2000 Series Reference guide

Pepperl+Fuchs

Pepperl+Fuchs 2-D LiDAR R2000 Series Reference guide

Pepperl+Fuchs VIM6 Series User manual

Pepperl+Fuchs

Pepperl+Fuchs VIM6 Series User manual

Pepperl+Fuchs UC4000-L2-E4-V15 User manual

Pepperl+Fuchs

Pepperl+Fuchs UC4000-L2-E4-V15 User manual

Pepperl+Fuchs LUC-M10 Installation instructions

Pepperl+Fuchs

Pepperl+Fuchs LUC-M10 Installation instructions

Pepperl+Fuchs INY360D-F99-2I2E2-V17 User manual

Pepperl+Fuchs

Pepperl+Fuchs INY360D-F99-2I2E2-V17 User manual

Pepperl+Fuchs UC6000-30GM-2EP-IO-V15 User manual

Pepperl+Fuchs

Pepperl+Fuchs UC6000-30GM-2EP-IO-V15 User manual

Pepperl+Fuchs UC-18GS Series Installation and operation manual

Pepperl+Fuchs

Pepperl+Fuchs UC-18GS Series Installation and operation manual

Pepperl+Fuchs LUC-M Series Parts list manual

Pepperl+Fuchs

Pepperl+Fuchs LUC-M Series Parts list manual

Pepperl+Fuchs NCB4-12GM40-N0-V1 User manual

Pepperl+Fuchs

Pepperl+Fuchs NCB4-12GM40-N0-V1 User manual

Pepperl+Fuchs UC L2 Series Installation and operation manual

Pepperl+Fuchs

Pepperl+Fuchs UC L2 Series Installation and operation manual

Pepperl+Fuchs GLV18-8-200/73/120 User manual

Pepperl+Fuchs

Pepperl+Fuchs GLV18-8-200/73/120 User manual

Pepperl+Fuchs WILSEN.sonic.level User manual

Pepperl+Fuchs

Pepperl+Fuchs WILSEN.sonic.level User manual

Pepperl+Fuchs NJ5-11-N-G User manual

Pepperl+Fuchs

Pepperl+Fuchs NJ5-11-N-G User manual

Pepperl+Fuchs OPC User manual

Pepperl+Fuchs

Pepperl+Fuchs OPC User manual

Pepperl+Fuchs LGM Series Reference guide

Pepperl+Fuchs

Pepperl+Fuchs LGM Series Reference guide

Pepperl+Fuchs VDM54 Series User manual

Pepperl+Fuchs

Pepperl+Fuchs VDM54 Series User manual

Pepperl+Fuchs 2-D LiDAR R2000 Series User manual

Pepperl+Fuchs

Pepperl+Fuchs 2-D LiDAR R2000 Series User manual

Pepperl+Fuchs RLK28-55/31/116 User manual

Pepperl+Fuchs

Pepperl+Fuchs RLK28-55/31/116 User manual

Pepperl+Fuchs NJ2-12GK-SN-03M User manual

Pepperl+Fuchs

Pepperl+Fuchs NJ2-12GK-SN-03M User manual

Popular Accessories manuals by other brands

Makita DFJ210 instruction manual

Makita

Makita DFJ210 instruction manual

Marmitek IR455 owner's manual

Marmitek

Marmitek IR455 owner's manual

Potek SK522-W user manual

Potek

Potek SK522-W user manual

Williams 7691 instructions

Williams

Williams 7691 instructions

HATHASPACE Aroma Diffuser user guide

HATHASPACE

HATHASPACE Aroma Diffuser user guide

Flyron FNP-703A user manual

Flyron

Flyron FNP-703A user manual

Kogan KAPEN4GSPYA user manual

Kogan

Kogan KAPEN4GSPYA user manual

SICK UM18-2 Pro operating instructions

SICK

SICK UM18-2 Pro operating instructions

Campbell 61302V instruction manual

Campbell

Campbell 61302V instruction manual

Philips SPF1002B Specifications

Philips

Philips SPF1002B Specifications

Denver PBA-30006 user manual

Denver

Denver PBA-30006 user manual

SICK D 35 Series operating instructions

SICK

SICK D 35 Series operating instructions

Julabo FT402 operating manual

Julabo

Julabo FT402 operating manual

HJH MARDERSCHUTZ 737 user manual

HJH

HJH MARDERSCHUTZ 737 user manual

Omron F3SG-PG Series Quick installation manual

Omron

Omron F3SG-PG Series Quick installation manual

STEINEL IS 2180 ECO installation instructions

STEINEL

STEINEL IS 2180 ECO installation instructions

Siemens SIMATIC RF300 System manual

Siemens

Siemens SIMATIC RF300 System manual

SICK KTX Prime KTX-WB91141259ZZZZ manual

SICK

SICK KTX Prime KTX-WB91141259ZZZZ manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.