Prexiso P40A User manual

IMPORTANT: Read before using
P40A
®
PENLASER DISTANCE MEASURE WITH CLIP
www.prexiso-eu.com
2WARRANTY
LIMITED
YEARS
135FT
40M
FUNC

1
EN
Table of Contents
Instrument Set-up ------------------------------ 2
Overview------------------------------------------------
Display---------------------------------------------------
Insert batteries ----------------------------------------
2
2
2
Operations ---------------------------------------- 3
Switching ON/OFF -----------------------------------
Measurement Reference --------------------------
Unit setting ---------------------------------------------
3
3
3
Functions ----------------------------------------- 4
Continuous measuring------------------------------
Area------------------------------------------------------
Volume--------------------------------------------------
Reset----------------------------------------------------
Addition/Subtraction---------------------------------
4
4
4
5
5
Technical Data -----------------------------------
Error, faults & troubleshooting ------------
Care -------------------------------------------------
Disposal -------------------------------------------
6
6
6
6
Safety Instructions ----------------------------
Warranty -------------------------------------------
Symbols used -----------------------------------------
Permitted use -----------------------------------------
Prohibited use ----------------------------------------
Hazards in use ---------------------------------------
Limits of use ------------------------------------------
Areas of responsibility -----------------------------
Electromagnetic Compatibility (EMC) ----------
FCC statement (applicable in U.S.) -------------
Laser classification ----------------------------------
7
9
7
7
7
7
7
8
8
8
8
Prexiso P40A
1
1
CAUTION:
If you have no such manual, or it is in the wrong
language, please ask your agency for an appropriate
copy.
The product is permitted to use for skilled persons
only.
Do not use the product before you
have studied the User Manual on the
enclosed CD or on our Homepage.
Use of controls or adjustment or performance of
procedures other than those specified herein may
result in hazardous radiation exposure.
• Do not attempt to modify the performance
of this laser device in any way. This may
result in a dangerous exposure to laser
radiation.
• Do not operate the tool outdoors.
• Do not attempt to repair or disassemble
the laser-measuring tool. If unqualified
persons attempt to repair this product,
serious injury
may occur. Any repair required on this
laser product should be performed only
by qualified service personnel.
• Do not stare into the laser beam or direct
it towards other people unnecessarily.
• Don't dazzle other individuals.
• Looking directly into the beam with
optical aids can be hazardous.
• Do not operate the product in explosion
hazardous areas or in aggressive
environments.
• Only use chargers recommended by the
manufacturer to charge the batteries.
• Keep extremities in a safe distance from
the moving parts.
• Watch out for erroneous measurements if
the product is defective or if it has been
dropped or has been misused or
modified.
• Carry out periodic test measure-ments.
Particularly before, during and after
important measure- ments.
• The product and batteries must not be
disposed of with household waste.
• It is a Class 2 laser product in accordance
with IEC 60825-1:2014
WARNING:
Important Safety
Instructions
Important Safety -------------------------------
Instructions --------------------------------------------

Instrument Set-up
Overview
The safety instructions and the user manual should be
read through carefully before the product is used for
the first time.
The person responsible for the product must ensure
that all users understand these directions and adhere
to them.
Display
Insert batteries
Prexiso P40A
2
EN
i
Change
batteries when
battery symbol
is empty.
FUNC
Display
On / Off /
Measure
Units/Area/
Volume/
Addition/
Subtraction
Unit
Battery
Measuring
Reference
Area/Volume
' "
' "
+
-
+
-
ftim
ftim

Prexiso P40A
' "
3
EN
ON OFF
5 sec
i
0.000 m
0' ''00 1/16
0 1/16 in
0.00 ft
1
The system
default
measurements
start at the
bottom as a
reference point.
Device is turned
OFF.
Switch between the
following units:
Press button to
confirm UNIT
Operations
Switching ON / OFF
Measurement Reference
If no key is
pressed for
120 sec, the
device
switches off
automatically.
FUNC
3 sec
1 2
Press button 3
sec to
measurement
reference mode
Press button
to UNIT setting
mode
3 4
Unit setting
FUNC
FUNC
4
The
measurement
and the system
recovery to initial
setting.
3 sec
2
Press button
to change the
reference to
Measurement
Reference
setting mode.
FUNC
3
Press button
to change the
reference to
top for
measurement.
FUNC

Prexiso P40A
Volume
1 2
Aim laser at
first target
point.
3 4
Aim laser at
second target
point.
5
Aim laser at
third target
point.
6
2x
4
EN
Measuring Functions
1 2
Stops continuous
measuring.
3
Continuous measuring
The last value measured is
displayed.
Aim active laser at target.
49'08"
7
/
16
Area
1
x
1 2
Aim laser at first
target point.
3 4
Aim laser at
second target
point.
5
i
The result is shown in the
main line and the measured
distance above.
FUNC
29.99
ft
2
FUNC

7
i
The result is shown in the main
line and the measured distance
above.
i
Long press FUN button for
1.5seconds to return back to
initial state.
Prexiso P40A 5
EN
4
The result is
shown in the
main line and the
measured
distance above.
1
Press button to
Addition/Sub-
traction mode
3
Then
measure
the second
data.
Addition/subtraction
Reset
2
Measure the
first data.
3X 4X
+10’00
"
109'99"
7
/
16
-10’00
"
89'99"
7
/
16
10'00"
or
299.99 ft
3
FUNC
1.5 sec
FUNC
FUNC
1
' "
99'99"
7
/
16
' "
99'99"
7
/
16

EN
Prexiso P40A
6
Technical Data
*The typical measurement uncertainty of ± 3 mm
is valid for measurements on white, diffusive,
reflective targets up to 5 m at low ambient light
and moderate temperatures. For distances
greater than 5 m, the measurement uncertainty
could increase additionally by 0.1 mm/m. In
unfavourable conditions (such as bright sunlight,
targets with poor reflectivity, or high or low
temperatures) the measurement uncertainty
could further increase up to ± 8 mm for distances
below 5 m and additionally by roughly 0.15
mm/m for distances greater than 5 m.
Error, faults & troubleshooting Care
• Clean the device with a damp, soft cloth.
• Never immerse the device in water.
• Never use aggressive cleaning agents or
solvents.
Disposal
CAUTION
The battery must not be disposed of
with household waste. Care for the
environment and take them to the
collection points provided in
accordance with national or local
regulations.The product must not be
disposed with household waste.
Dispose of the
product appropriately in
accordance with the national
regulations in force in your country.
Adhere to the national and country
specific regulations. Product specific
treatment and waste management
can be downloaded from our
homepage.
General
Maximum
measuring range*
Measuring accuracy*
Measuring units
Laser class
Laser type
Autom. power switch-off
Autom. laser off
Battery durability
(2 x AAA)
Dimension(LxWxH)
Weight (without batteries)
Operation Temperature
Storage Temperature
1-135ft / 0.30-40m
(measure from top side)
± 1/8 in
± 3 mm
ft+inch/m/ft/inch
2
620nm - 690nm
120s
30s
up to 3000
measurements
6.1 x 0.91x0.71 in
155x23x18 mm
1.41oz / 40g
32 to 104 °F
0 to 40 °C
14 to 140 °F
-10 to 60 °C
Faults Cause Solution
IC401
IC201
IC303
IC102
IC505
Change batteries
Change to a darker
environment for test
Improve the reflective surface.
(Use target plate, white paper)
Measuring the distance within
measurement range.
Improve the reflective surface.
(Use target plate, or don't
aim at strong light)
Switch on / off the device,
if the symbol still appears
after several times, please
contact with your dealer.
Low battery
The environment
is too bright
Received signal too
weak or Out of
measuring range
Received signal too
strong
Hardware error

7
EN
Prexiso P40A
Safety Instructions
The person responsible for the instrument
must ensure that all users understand
these directions and adhere to them.
Symbols used
The symbols used have the following
meanings:
WARNING
Indicates a potentially hazardous situation
or an unintended use which, if not avoided,
will result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation
or an unintended use which, if not avoided,
may result in minor injury and/or
appreciable material, financial and
environmental damage.
Important paragraphs which must be
adhered to in practice as they enable
the product to be used in a technically
correct and efficient manner.
Permitted use
• Measuring distances
Prohibited use
• Using the product without instruction
• Using outside the stated limits
• Deactivation of safety systems and
removal of explanatory and hazard
labels
• Opening of the equipment by using tools
(screwdrivers, etc.)
• Carrying out modification or conversion
of the product
• Use of accessories from other
manufacturers without express approval
• Deliberate dazzling of third parties; also
in the dark
• Inadequate safeguards at the surveying
site (e.g. when measuring on roads,
construction sites, etc.)
• Deliberate or irresponsible behaviour on
scaffolding, when using ladders, when
measuring near machines which are
running or near parts of machines or
installations which are unprotected
• Aiming directly in the sun
Hazards in use
WARNING
Watch out for erroneous measurements if
the instrument is defective or if it has been
dropped or has been misused or modified.
Carry out periodic test measurements.
Particularly after the instrument has been
subject to abnormal use, and before,
during and after important measurements.
CAUTION
Never attempt to repair the product
yourself. In case of damage, contact a
local dealer.
WARNING
Changes or modifications not expressly
approved could void the user’s authority
to operate the equipment.
Limits of use
Refer to section "Technical data".
The device is designed for use in
areas permanently habitable by humans.
Do not use the product in explosion
hazardous areas or in aggressive
environments.
i

EN
Prexiso P40A
8
Safety Instructions
Areas of responsibility
Responsibilities of the person in
charge of the instrument:
• To understand the safety instructions
on the product and the instructions in
the User Manual.
• To be familiar with local safety
regulations relating to accident
prevention.
• Always prevent access to the product
by unauthorised personnel.
Electromagnetic Compatibility
(EMC)
WARNING
The device conforms to the most
stringent requirements of the relevant
standards and regulations. However,
the possibility of causing interference
in other devices cannot be totally
excluded.
This equipment has been tested and
found to comply with the limits for a Class
B digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to
provide reasonable protection against
harmful interference in a residential
instal-lation.This equipment generates,
uses and can radiate radio frequency
energy and, if not installed and used in
accordance with the instructions, may
cause harmful interference to radio
communications.
However, there is no guarantee that
inter-ference will not occur in a particular
instal-lation. If this equipment does cause
harmful interference to radio or television
reception, which can be determined by
turning the equipment off and on, the user
is encouraged to try to correct the
interference by one or more of the
following measures:
• Reorient or relocate the receiving
antenna.
• Increase the separation between the
equipment and receiver.
• Connect the equipment into an outlet
on a circuit different from that to which
the receiver is connected.
• Consult the dealer or an experienced
radio/TV technician for help.
FCC statement (applicable in U.S.)
The device produces visible laser
beams, which are emitted from the
instrument: It is a Class 2 laser
product in accordance with:
Do not stare into the laser beam or
direct it towards other people
unnecessarily. Eye protection is
normally afforded by aversion
responses including the blink reflex.
Laser Class 2 products:
IEC60825-1 : 2014“Radiation safety
of laser products”
WARNING
Looking directly into the beam with
optical aids (e.g. binoculars,
telescopes) can be hazardous.
Safety Instructions
Laser classification

9
EN
Prexiso P40A
WARRANTY
Two-Year Limited Warranty. This product is warranted to
the original purchaser from the original purchase
date for two years subject to the warranty coverage
described herein.Please retain your receipt.This product
is warranted to the original user to be free from defects in
material and workmanship. If you believe that the
product is defective at any time during the specified
warranty period, pls contact Prexiso customer service
warranty does not cover:(1) Part failure due to normal
wear or product abuse;(2) Any parts have been altered or
modified by anyone other than an authorized
Prexiso personnel or failure to install and operate
equipment according to the guidelines put forth in the
instruction manual.(3)Any products or parts used for
rental purposes, damage resulting from shipping (claims
must be filed with freighter), accident, abuse, act of God,
misuse, or neglect. Prexiso will replace or repair
the defective unit, at its option, subject to verification of
the defect.Any implied warranties arising from the
sale of a Prexiso product, including but not limited to
implied warranties of merchantability and fitness for a
particular purpose, are limited to the above. Prexiso shall
not be liable for loss of use of the product or other
incidental or consequential damages, expenses, or
economic loss, or for any claim of such damage,
expenses, or economic loss.This warranty excludes any
accessories. This warranty gives you specific legal
rights, and you may also have other rights that vary from
state.
Labelling
Subject to change (drawings, descriptions
and technical data) without prior notice.
P40A
Table of contents
Other Prexiso Measuring Instrument manuals

Prexiso
Prexiso P60L User manual

Prexiso
Prexiso P15M-3LI User manual

Prexiso
Prexiso PMX-42A User manual

Prexiso
Prexiso P70DLI User manual

Prexiso
Prexiso PR500HV Instruction Manual

Prexiso
Prexiso G5 Series User manual

Prexiso
Prexiso P20 User manual

Prexiso
Prexiso PR500HVG User manual

Prexiso
Prexiso P15 User manual

Prexiso
Prexiso PLT40LI User manual
Popular Measuring Instrument manuals by other brands

DeFelsko
DeFelsko PosiTector 200 Reference

Omnitronic
Omnitronic SLM-600 user manual

IFM Electronic
IFM Electronic efector300 SD2001 operating instructions

Watkins-Johnson Company
Watkins-Johnson Company AN/PRD-11 Operator's maintenance manual

Liqua-Tech
Liqua-Tech LPM-101 Operation & maintenance manual

Bilanciai
Bilanciai B-TEK Scales T503W user manual