Qtx GYRO User manual

152.761UK User Manual
TECHNICAL SPECIFICATION
Voltage : 230Vac, 50/60Hz Blue : 300mW 455nm
Fuse : 2A Slow blow DMX Channels : 6
Laser Class : 3B Dimensions : 190 x 190 x 110mm
Red Laser: 100mW 638nm Power Consumption : 45W
Green Power : 50mW 532nm Weight : 2.4kg
IMPORTANT NOTE: This product conformed to Laser & LED afety standard
B EN60825-1 2007 incorporating corrigendum 2008
DISPOSAL:
Please dispose of the unserviceable device according to the current statutory requirement
Errors and omissions excepted.
Copyright© 2012. AV L Group Ltd.
GYRO
RGB LA ER
Order ref: 152.761UK
User Manual
IMPORTANT SAFETY NOTICE
Please read this manual before operating
VERSION 1.0

152.761UK User Manual
152.761UK User Manual
DMX CHANNEL DMX
VALUE DESCRIPTION
1 (Mode)
000-010 Blackout
011-062 ound to light
063-127 Auto mode
128-192 DMX 512 elect gobo (Only CH2
activated)
190-255 DMX 512 Control mode (all other
channels activated)
2 (X ax s
rotat on)
000-255 Laser Gobo select (ONLY when CH1 in
DMX elect gobo mode)
000-255 X axis rotation
3 (Y ax s
rotat on) 000-255 Y axis rotation
4 (Colour
Select)
000-041 White
042-083 Red
084-125 Green
126-167 Blue
168-209 Yellow
210-251 Pink
252-254 Cyan
255 Colour display in sections
5 (Sect on
D splay) 000-255 et multiple colours per section of the
beam (Only when CH4 = 255)
6 (Colour
sect on length) 000-255 ection show gradually become longer

152.761UK User Manual
DMX
The fixture is equipped with 3-pin XLR connectors for DMX input and output. The E
connectors are wired in parallel. Only use a shielded twisted-pair cable designed for 3-pin XLR-
plugs and connectors in order to connect the controller with the fixture or one fixture with
another.
Building a serial DMX-chain:
Caut on: At the last fixture, the DMX-cable has to end with a terminator. older a 120 Ohm
resistor between PIN 2 (-) and PIN 3 (+) into a 3-pin XLR-plug and plug it in the DMX-output
of the last fixture.
When in DMX mode there are two channels with the following function:
152.761UK User Manual
INTRODUCTION:
GYRO - RGB LASER
Thank you for purchasing this Gyro laser.
This laser effect moves away from the traditional stepper motor laser patterns of the past,
producing some spectacular gobo effects that rotate at different speeds whilst transforming
into different colours and shapes. The laser is best projected on to a flat surface, such as a
wall or ceiling, or through smoke. Brighter red laser technology allows this effect to produce
much more vibrant colours. Works great as a single unit or as a pair and is an ideal addition to
any lighting rig or for use in permanent installations such as nightclubs or discos.
Unique gobo-like patterns
Brighter 638nm Red laser technology
0.45W total laser power (Red: 100mW, Green 50mW, Blue: 300mW)
Auto, sound-to-light, pattern select and 6 channel DMX modes
Master/slave mode
Easy digital display to set the mode of operation
Key controlled for laser safety
We recommend that this product is used within the guidelines H G95

152.761UK User Manual
CAUTION
•Please read th s manual fully before nstall ng or operat ng th s
product as t conta ns mportant safety nformat on relat ng to ts
nstallat on and operat on.
•Th s Class 3B
laser product em ts hazardous levels of opt cal
rad at on and w ll cause njury to the eyes f v ewed d rectly.
•Th s product s not su table for project on d rectly at aud ences or
other persons.
•Th s product must not be used for any form of aud ence scann ng
appl cat on and s for profess onal use only.
152.761UK User Manual
OPERATION FOR GYRO
Press the “FUNC” button to enter setup mode followed by the “UP” & “DOWN” keys to select
the mode you desire. To confirm your selection press “ENTER”
D splay Funct on
AUt Auto running random effects cycle
OU ound activated random effects cycle
rgb Colour select mode
P00-P19 Gobo elect
001-512 DMX address

152.761UK User Manual
REAR PANAL GYRO LASER:
1. Power ON/OFF witch
2. IEC Power IN
3. Digital display
4. ound sensitivity
5. Microphone
6. DMX OUT
7. DMX IN
8. afety Key
152.761UK User Manual
IMPORTANT INFOMATION:
This product is a Class 3B laser and should only be installed and used by persons who are
trained in the management of laser radiation and are able to operate in accordance within the
guidance given by the Health and afety Executive (H E) in H (G)95: “The Radiation afety of
Lasers used for Display purposes”.
Copies of this guide can be downloaded from the H E website below:
www.hse.gov.uk/pubns/priced/hsg95.pdf
This product contains no user-serviceable parts. Under no circumstances should any attempt
be made by the user to dismantle or modify it in any way.
INSTALLATION AND MOUNTING INSTRUCTIONS:
This product must be securely mounted so that its emission is always directed away from
people and objects that are able to reflect the emission towards people. In this regard the
separation distances of 3 metres vertically and 2.5 metres horizontally, cited in H (G)95 and
shown overleaf must be observed.

152.761UK User Manual
VERTICAL BIRDS EYE VIEW:
152.761UK User Manual
LAYOUT GYRO LASER:
1. Mounting bracket
2. Thumb screw
3. Laser Aperture

152.761UK User Manual
TROUBLESHOOTING
If the un t s not funct on ng properly
Check that the IEC cable is connected properly
Check that the mains power switch is on.
Check the fuse hasn’t blown (see below guide)
Check that the unit isn’t in DMX mode.
Check the safety key is turned to the on position.
If in sound to light mode ensure the microphone sensitivity is turned up.
REPLACING FUSE
First disconnect from the mains power supply then remove the fuse holder above the IEC
ocket to reveal the fuse. Replace with the correct fuse rating as stated on the product or in
the user manual. Then lock the fuse holder cover back into place.
GENERAL MAINTENANCE
Be sure to power off the fixture before conducting maintenance.
To maintain optimum performance and minimise wear, fixtures should be cleaned frequently.
Usage and environment are contributing factors in determining frequency. As a general rule,
fixtures should be cleaned at least twice a month. Dust build-up reduces light output &
performance as well as overheating. This can lead to reduced life and increased mechanical
wear.
Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust
collected on external vents and internal components. Clean all glass when fixture is cold with a
mild solution to the cloth or tissue, and drag dirt and grime to the outside of the lens. Gently
polish optical surfaces until they are free of haze and lint.
The cleaning of internal and external optical lenses and/or mirrors must be carried out
periodically to optimise light output. Cleaning frequently depends on the environment in which
the fixture operates: damp, smoky or particularly dirty surroundings can require cleaning fluid.
Always dry the parts carefully. Clean the external optics at least every 20 days.
152.761UK User Manual
VERTICAL CROSS SECTIONAL VIEW:

152.761UK User Manual
PACKAGE CONTENTS:
Please check the contents to ensure that the product has been received in good condition.
Laser x 1unit User’s Guide x 1pc
IEC Power Lead x 1pc afety Keys x 2pcs
If you find any accessory is missing or the product has arrived with any problems, please
contact your retailer at once.
This product contains no user-serviceable parts so make no attempt to try to fix or modify this
item yourself as this will invalidate the warranty. We recommend you keep the original
package and proof of purchase for any possible replacement or returned demand.
SETUP:
1. Unpack the laser ensuring all packaging and tape is removed.
2. Always test the laser before fixing in a permanent location.
3. Connect the IEC mains plug and power up.
4. Insert the safety key and turn to a quarter turn clockwise. At this moment ensure that
no one is exposed to laser radiation.
5. elect which mode you want to operate the laser in.
6. Leave the laser to run for 10 minutes before installing in its location.
152.761UK User Manual
CONNECT WITH POWER SUPPLY – THE GROUND WIRE MUST BE
CONNECTED:
Use the supplied IEC lead to connect to the main power supply as follows:
W re Connect on Internat onal s gnal
Brown Live L
Blue Neutral N
Yellow /Cyan Earth
For your safety, please kindly pay attention to all of the warnings below:
Always plug in the power plug last and disconnect from the mains when the device is
not in use or before cleaning.
Do not install and operate the device in rain or extreme heat, moisture or dusty
environments.
This device is for indoor use only and in a dry environment.
Do not switch on immediately. Wait until the unit reaches room temperature.
Do not shake the device and avoid brute force when installing or operating.
Do not use the device during thunderstorms and please disconnect the power.
Do not use solvents or aggressive detergent to clean the device. Use a soft and clean
cloth.
Do not modify the device or the connected power cord without authorisation.
Do not stare into the aperture. This product emits hazardous levels of optical radiation
and will cause serious injury to the eyes if viewed at close range.
This product should be securely mounted so that its output emission is always directed
away from people and at objects that are able to reflect emission towards people. In
this regard, the separation distances cited in H (G)95 should be observed.
The symbol determines the minimum distance from lighted objects. The
minimum distance between light-output and the illuminated surface must be more than
0.5m.
Table of contents