This manual suits for next models

17

Other Rebotec Mobility Aid manuals

Rebotec ECO 100 User manual

Rebotec

Rebotec ECO 100 User manual

Rebotec FIXI User manual

Rebotec

Rebotec FIXI User manual

Rebotec James 150 User manual

Rebotec

Rebotec James 150 User manual

Rebotec 133 30 Series User manual

Rebotec

Rebotec 133 30 Series User manual

Rebotec 181.10 User manual

Rebotec

Rebotec 181.10 User manual

Rebotec Brest User manual

Rebotec

Rebotec Brest User manual

Rebotec Fixi-YANO User manual

Rebotec

Rebotec Fixi-YANO User manual

Rebotec FIXI User manual

Rebotec

Rebotec FIXI User manual

Rebotec Arnold 150 User manual

Rebotec

Rebotec Arnold 150 User manual

Rebotec Hamburg User manual

Rebotec

Rebotec Hamburg User manual

Rebotec Arnold 150 User manual

Rebotec

Rebotec Arnold 150 User manual

Rebotec 153 Series User manual

Rebotec

Rebotec 153 Series User manual

Rebotec Polo-YANO User manual

Rebotec

Rebotec Polo-YANO User manual

Rebotec Arnold 125 User manual

Rebotec

Rebotec Arnold 125 User manual

Rebotec Polo Standard User manual

Rebotec

Rebotec Polo Standard User manual

Rebotec Verona User manual

Rebotec

Rebotec Verona User manual

Rebotec YANO Series User manual

Rebotec

Rebotec YANO Series User manual

Rebotec Polo-Yano S User manual

Rebotec

Rebotec Polo-Yano S User manual

Rebotec 340 Series User manual

Rebotec

Rebotec 340 Series User manual

Rebotec Fixi-YANO User manual

Rebotec

Rebotec Fixi-YANO User manual

Rebotec Big 250 User manual

Rebotec

Rebotec Big 250 User manual

Rebotec Walk-On XS User manual

Rebotec

Rebotec Walk-On XS User manual

Rebotec Arnold 150 User manual

Rebotec

Rebotec Arnold 150 User manual

Rebotec YANO-Walker User manual

Rebotec

Rebotec YANO-Walker User manual

Popular Mobility Aid manuals by other brands

Drive DeVilbiss GoLite 200 operating instructions

Drive DeVilbiss

Drive DeVilbiss GoLite 200 operating instructions

Invacare 8153-J user manual

Invacare

Invacare 8153-J user manual

Clearwell Mobility Brandon User instructions

Clearwell Mobility

Clearwell Mobility Brandon User instructions

Handicare 1100 user manual

Handicare

Handicare 1100 user manual

NRS Healthcare M11090 User instructions

NRS Healthcare

NRS Healthcare M11090 User instructions

Alber Scalamobil iQ operating instructions

Alber

Alber Scalamobil iQ operating instructions

Ferno CCT-PX user manual

Ferno

Ferno CCT-PX user manual

Medline MDS86835DSHEC User Instructions & Warranty

Medline

Medline MDS86835DSHEC User Instructions & Warranty

Guldmann Twin Turner II user manual

Guldmann

Guldmann Twin Turner II user manual

Ferno 35-ITA user manual

Ferno

Ferno 35-ITA user manual

Drive ROOMBA Operation manual

Drive

Drive ROOMBA Operation manual

Gate Balder operating instructions

Gate

Gate Balder operating instructions

Decon wheel TNS Notos Assembly instructions

Decon wheel

Decon wheel TNS Notos Assembly instructions

ExoAtlet ExoAtlet-II user manual

ExoAtlet

ExoAtlet ExoAtlet-II user manual

Invacare Storm Series parts catalog

Invacare

Invacare Storm Series parts catalog

Rhythm Healthcare B3800F manual

Rhythm Healthcare

Rhythm Healthcare B3800F manual

AMF-BRUNS PROTEKTOR installation manual

AMF-BRUNS

AMF-BRUNS PROTEKTOR installation manual

Drive DeVilbiss Healthcare OTTER Instructions for use

Drive DeVilbiss Healthcare

Drive DeVilbiss Healthcare OTTER Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

REBOTEC®Rehabilitationsmittel GmbH
DE-49610 Quakenbrück, Artlandstr. 57- 59
Telephone: +49 (0) 5431/9416-0
Fax: +49 (0) 5431/9416- 66
Web: www.rebotec.de
BA-Nr.: 02.01.001/2021-07-A01 Email: [email protected]
Read this User Manual before using the device for the first time and keep it at hand for the user as
well as for future use and subsequent sales.
EN
User Manual
Walking aids
1. Product description
1.1. Introduction
•The product described here is a medical device of risk class I ac-
cording to (EU) 2017/745 MDR.
•In this user manual, you will find information on the safe and proper
initial operation, use, maintenance and care of this product. Care-
fully read this user manual before using the device. Follow the safety
instructions and act accordingly.
2. Features
2.1. Intended purpose
•The product is used for support and relief in case of restrictions of
the lower extremities. It allows the user to pursue their desire for
mobility. There must be sufficient upper body musculature for safe
use. Persons with sensory impairments may not be able to use this
item. The article does not impose any special requirements on the
education of the user.
Specification:
a=Height adjustable / b=Continuous tube, can be shortened
c=Indoor & outdoor use
1=Standard clip / 2=Squeeze pressure / 3=Squeeze clip
4=Standard pressure
2.2. Conditions of use
•Temperature range: -10°C to +35°C; direct radiant heat on the prod-
uct must be avoided. Relative humidity: 40% to 85%. Outside of
these conditions, the product must only be used for a short time.
•The product is not suitable for use in swimming pools or saunas, as
surface discolouration and limitations of mechanical strength may
occur.
2.3. Storage & transport
•Temperature range: +5° C to+25° C; direct radiant heat on the prod-
uct must be avoided. Store the product in dry rooms with a humidity
of up to 65%.
2.4. Disposal
•Disposal and recycling of used products and packaging must be car-
ried out in accordance with currently valid regulations. Please con-
tact a disposal company for further information. The Infection Pro-
tection Act must be observed. Please observe any labels and infor-
mation on packaging material and act accordingly.
3. Symbols & nameplates
Symbol
Meaning
Symbol
Meaning
Read the man-
ual!
Year of manufacture
Device
Article number
Manufacturer
Language
Maximum user
weight in kg
Important infor-
mation!
Product complies
with (EU) 2017/745
MDR
4. Warranty
•For this product the manufacturer grants a warranty of 12 months.
Compliance with the general terms and conditions(www.rebo-
tec.de/agbs), as well as the intended use, are a basic prerequi-
site. The statutory warranty provisions shall apply.
•Unauthorised modifications to this product will void the product’s
conformity and the warranty.
4.1. Complaint
•Please contact us before returning the product. To reduce transport
damage, use the original packaging if possible.
•The Infection Protection Act must be complied with.
Please make sure that the product does not pose a risk of infec-
tion when returned. Enclose an information sheet on safety with
the product. Costs may incur for returns that are not marked non-
objectionable.
5. Safety instructions
Please observe the following safety instructions:
•Before using the device for the first time, the User
Manual must be read completely in order to avoid damage
caused by fault operation or hazards. Before each use, check the
device for visible damage or deficiencies. In case of malfunctions or
damage of any kind, the device must not be used. Regularly check
the suction foot for damage and wear; replace if necessary.
•The walking aid must be placed on the floor as vertically as possible
when walking. Therefore, never position the walking aid too far away
from the body or forward in the walking direction. Grasp the handle
completely and firmly with one hand. If possible, have an assistant
accompany and support you so that they can catch you if you fall.
•The walking aid must not be used for any other purpose. Therefore,
only use them to support your ability to walk and not, for example,
as a stand-up aid, for levering, moving furniture or other objects. Do
not attach any objects (bag, pouch, etc.) to the walking aid.
•After a long period of disuse: Have the walking aid checked by qual-
ified personnel or a specialist dealer. Do not perform any unauthor-
ised mechanical modifications (product liability!). Do not expose the
Designation
100.20…
ECO 100
1
100kg
c
a
100.22…
ECO 120
4
120kg
c
a
101…
Magic-Twin
1
130kg
c
a
102…
Magic-Twin
2
130kg
c
a
103…
Magic-Twin
3
130kg
c
a
104…
Magic-Twin, extended
length
3
130kg
c
a
105…
Magic-Soft
2
130kg
c
a
105...10
Magic-Soft, extended
length
3
130kg
c
a
106.10
Big 150
-
150kg
c
b
106.30
Big 130 Soft-Anatom
-
130kg
c
b
107…
Magic-Soft-Anatom
2
130kg
c
a
109…
Combi-Soft
2
130kg
c
a
110…
Comfort-Soft
3
130kg
c
a
112…
Comfort
3
130kg
c
a
115…
Combi
3
130kg
c
a
116…
Safe-In
3
130kg
c
a
116…20
Safe-In, extended length
3
130kg
c
a
117…
Safe-In-Soft
3
130kg
c
a
118…
Safe-In-Anatom-Soft
3
130kg
c
a
119…
Safe-In-Anatom
3
130kg
c
a
120…
Light-Line
3
100kg
c
a
122…
Fun-Kids
3
100kg
c
a
EN
REBOTEC / BA-Nr.: 02.01.001/2021-07-A01
EN
walking aid to sunlight for a longer period of time (at the window, at
the heater, in the car). Heat can lead to changes in material proper-
ties and durability.
•Attention, danger of slipping: Never walk with the walking aid on
snow or ice-covered ground without the anti-skid device (ice claw).
Be careful when walking over damp tiles, floors or crossing loose
carpeting. Never clean handles or suction caps with substances
containing oil. Be careful with unevenness, holes in the ground and
loose subsoil, because the walking aid can slip away unexpectedly
or sink in.
•There is a risk of injury with surface temperatures > 40°C. Do not
expose theproduct to hightemperatures (e.g.sunlight, radiators, hot
water). Allow the product to cool before use.
If the product is used by patients with insensitive skin (no
temperature perception or skin damage), a heat check
(e.g. touching with the back of the hand) must be carried
out by the nursing staff.
6. Incident reporting
•Serious incidents in connection with the product must be re-
ported immediately to the manufacturer ([email protected] ) and
BfArM (www.bfarm.de/DE).Use the BfArM reporting functions and
provided forms.
7. Reuse, lifetime
•The product is suitable for reuse. How often the product can be re-
used depends on the frequency and nature of use. Before reuse, the
product must be reprocessed and the technical and functional safety
and reliability of the product must be checked and restored if neces-
sary. For more information, please see the reprocessing instructions
(01.12.154). The reprocessing instructions and the present oper-
ating instructions are available for download from www.rebo-
tec.de/downloads.
•If the product is used as intended, its lifetime is 2years. The effective
lifetime may vary depending on the frequency and intensity of use
and the general condition.
8. Setting up for use
•The product has been carefully inspected in the factory for freedom
from defects and completeness. Please check the product for any
possible transport damage and the completeness of the scope of
delivery upon receipt.
8.1. Adjustment to body height
•Have the product adjustedto your body height by the competent
qualified personnel. The height is adjusted by means of a tele-
scopic aluminium tube with aclip (2) or push button (1). If the product
has a screw connection, this must be loosened by turning to the left
before adjustment. After adjustment, the fitting must be tightened
again. Items with a continuous tube
must be cut to fit.
•The armrest adjustment can
be modified by the same principle as
the push button height adjustment.
9. Product data
•We reserve the right to make technical developments and im-
provements with respect to the design shown in this user man-
ual.
10. Cleaning and care
•The device can be cleaned using a mild conventional cleaning
and disinfecting agent. After cleaning, wipe the device w
11. Maintenance
•Have your walking aid checked by your specialist dealer at least
1x every six months. Worn suction feet (wearing part) must be
replaced immediately. Pay attention to the diameter (see 9). Pull
the suction foot off the end of the tube. Push on the new suction
foot as far as it will go and check that it is firmly seated.
Spare parts & accessories:
A / mm
B / mm
C /
mm
α
100.20…
215
735- 960
17
22°
100.22…
215
745- 970
19
22°
101…
225
725- 950
19
25°
102…
225
725- 950
19
25°
103…
225
725- 950
19
25°
104…
225
825- 1050
19
25°
105…
225
730- 955
19
25°
105...10
225
830- 1055
19
25°
106.10
225- 250
up to 1075
22
20°
106.30
225- 250
up to 1080
19
27°
107…
225
730- 955
19
25°
109…
225- 250
745- 970
19
23°
110…
225- 250
745- 970
19
23°
112…
225- 250
745- 970
19
23°
115…
225- 250
745- 970
19
23°
116…
225- 250
745- 970
19
23°
116…20
225- 250
845- 1070
19
23°
117…
225- 250
745- 970
19
23°
118…
225- 250
745- 970
19
23°
119…
225- 250
745- 970
19
23°
120…
160- 210
735- 960
17
23°
122…
160- 210
500- 725
17
23°
Art. no.
Designation
200…10
Suction foot 17mm
200…00
Suction foot 19mm
200…20
Suction foot 22mm
201…00
Adjustment clip 22
201…20
Adjustment clip 20
251.00.00
Push button with spring
01.01.001
User Manual
01.12.154
Reprocessing Instructions
160.02.02
Arm rest padding, Standard
160.02.03
Arm rest padding, Big
160.01.01
Handle padding, Mini
160.01.02
Handle padding, Standard
160.01.03
Handle padding, Big
160.01.04
Handle padding, Anatom
1
2