WIRING INSTRUCTIONS
RED -CONNECT TO CONSTANT +12 VOLTS VIA THE FUSE BOX AT THE POINT WHERE
THE INTERIOR LIGHT CIRCUIT IS POWERED. CURRENT (VOLTAGE) SENSING WILL
NOT WORK IF THIS PROCEDURE IS NOT FOLLOWED.
BLACK -CONNECT TO A SUITABLE EARTH ON THE CAR BODY
ORANGE
(x2)
-CONNECT TO THE LEFT AND RIGHT INDICATOR CIRCUITS
OF THE VEHICLE TO FLASH THE INDICATORS
YELLOW -CONNECT TO A +12 VOLTS IGNITION SWITCHED LEAD, WHICH DOES NOT FALL TO
0 VOLT WHEN THE ENGINE IS CRANKED
DARK BLUE -
-CONNECT TO PIN SWITCHES FOR BONNET
CONNECT TO PIN SWITCHES FOR BOOT (PLEASE NOTE: IT IS ADVISABLE TO WIRE
THE BOOT TO THE DOOR SWITCHES: THIS WILL PROVIDE “DOOR AJAR” WARNING
ON THE BOOT, AND ALSO SIGNAL THE AUTO RE-ARM FEATURE TO CANCEL IF
THE BOOT IS OPENED BY THE OWNER ON DISARMING THE SYSTEM.)
WHITE -CONNECT TO EXISTING DOOR SWITCHES.
(PLEASE NOTE: ONLY NEGATIVE SWITCHING DOORS, IF POSITIVE DOOR
SWITCHING - MUST USE RELAYS TO REVERSE TO NEGATIVE - SEE DIAGRAM)
GREEN (X2)
Inside main loom
-LOCATE THE POSITIVE FEED WIRE TO THE STARTER SOLENOID, CUT THAT WIRE
AND JOIN THE TWO GREEN WIRES TO EITHER END OF THE STARTER FEED WIRE
WHICH YOU HAVE JUST CUT WARNING: CUT OUT RELAYS HAVE 12A MAX
RATING. DISABLE ONLY STARTER SOLENOID, FUEL PUMP, OR IGNITION COIL IF
VEHICLE IS NOT EFI. UNDER NO CIRCUMSTANCES SHOULD YOU CUT THE
VEHICLE’S MAIN IGNITION SYSTEM.
GREEN (X2)
Outside main loom
-LOCATE THE POSITIVE FEED WIRE TO THE FUEL PUMP, CUT THAT WIRE AND JOIN
THE TWO GREEN WIRES TO EITHER END OF THE FUEL PUMP FEED WIRE WHICH
YOU HAVE JUST CUT WARNING: CUT OUT RELAYS HAVE 12A MAX RATING.
DISABLE ONLY STARTER SOLENOID, FUEL PUMP, OR IGNITION COIL IF VEHICLE IS
NOT EFI. UNDER NO CIRCUMSTANCES SHOULD YOU CUT THE VEHICLE’S MAIN
IGNITION SYSTEM.
YELLOW/ BLACK -THIS IS A SWITCHED NEGATIVE OUTPUT (-VE 150mA). CONNECT TO THE
NEGATIVE WIRE (USUALLY BLACK) ON ANY ACCESSORY USED ie. ULTRASONIC /
GLASS BREAKAGE / MICROWAVE DETECTORS OR ETC
LIGHT BLUE -THIS IS A NEGATIVE TRIGGER, AND SHOULD BE CONNECTED TO THE OUTPUT
CIRCUIT WIRE ON ANY ACCESSORY TO BE USED. (ie ULTRASONIC, MICROWAVE,
OR GLASS BREAK DETECTORS, ETC.)
BROWN -THIS IS THE NEGATIVE OUTPUT (150mA MAXIMUM) FOR THE BOOT RELEASE.
(Optional for use where electric boot release is to be connected)
VIOLET/BLACK -NEGATIVE TRIGGER ON ALARM TO BE USED TO INTERFACE TO PAGER OR
OPTIONAL SIREN (100mA MAXIMUM)
ORANGE/BLACK -NEGATIVE PULSE LOCK SIGNAL
PINK/YELLOW -NEGATIVE PULSE UNLOCK SIGNAL
PINK -CURRENT SENSING OVERRIDE. CONNECT TO POSITIVE POWER TO DISABLE
CURRENT SENSING. THIS CAN ALSO BE ACHIEVED VIA PROGRAMMING. SEE
BELOW
RED/WHITE -NEGATIVE TRIGGER TO SIREN. CONNECT TO THE GREEN WIRE OF AN SB41.
VIOLET/YELLOW -ALARM OVER RIDE. CONNECT TO THE WHITE WIRE ON AN SB41.
CURRENT SENSING