PART B: Control System User Manual 15
Gate-moving Logic
(A) In gate-opening phase: The gates stop if the transmitter/push button/key selector is activated, and close when
the transmitter/push button/key selector is reactivated.
(B) In gate-closing phase: The gates stop if the transmitter/push button/key selector is activated, and open when
the transmitter/push button/key selector is reactivated.
(C) In gate-opening or gate-closing phase: For safety purpose, the gates stop if encountering obstacles.
Checking the Gate Movement
1). Release the gear with the release key and move the gate to the middle so that it can move in both
the gates reaches the limit
opening and closing directions; then lock the gear.
2). Operate the gate to opened and closed position several times, and make sure
switch at least 2~3 centimeters before the mechanical stop.
LED Indication
LLED2ED2 DKey/S KeyKey selector, or the push button is activated, LED2 will be on.
LLED4ED4 LED4
Ph1will be on when Ph1 are triggered.
LLED3ED3 LED3
Ph2will be on when Ph2 are triggered.
Antenna
Lit+ Lit- Lat+ Lat- M1+ M1- M2+ M2- Lmt3 Lmt4
Lmt2 SKey Ph1 PhVcc Ph2 PhVcc
5V S1 S2
ANT
GND
GND DKey GND
GND
GND Lmt1 GND
J5
RF1
K3
K2K1
J4 J3
J7
J8
CO
NC NO
CO
- +- +
CO
NONC
- +
CO
NONC
NC NO
CO
- +
11111111
1
2
1919191919191919
LED2 LED4 LED3
Function Of The LED Display
LED Display Programmable Functions LED Display Programmable Functions
When the gate is opening, the LED Display
show ‘OPN’ for 2s and then change to Amp
current indication
When the gate is stopped, the LED Display show
‘STP’ until next commend has been made, after
10s no further movement, the LED turns to OFF
When the gate is closing, the LED Display show
‘CLS’ for 2s and then change to Amp current
indication
LED display shows “S01” means the panel did not
detected the M1+/M1 and M2+/M2 both been
connected before the system learning procedure,
check for motor wire connection, for dual gate
system
The memory of the system is all deleted/cleaned
by press and hold the UP + SET+ DOWN button
together for 5s and the panel will be back to
default settings
LED display shows “S02” means the panel did not
detected the M1+/M1 but detected M2+/M2 been
connected, notice the installer to check the motor
wire connection, if this is single gate system,
motor wire should connect to M1+/M1 not on
M2+/M2
LED display show “S03” means same button on
the remote has been identified for more than 2
functions
[LEA] means motor into the system learning
mode, do not interrupt during this procedure.
[D-G] means motor completed the learning
procedure for dual gate installation.
[S-G] means motor completed the learning
procedure for single gate installation.
[N-L] means system learning failed.
4
3
5678910 11 12 13 14 15
16 17 18 20 212223242526