
MODEL:F56A/F56B/F56C/N56D/F56E/F56F/F56AC/F56EC
7
1.5. Installation
A. Installation
Before installation, read all those instructions completely. Then obtain
all materials and tools needed for installation
The installation of product, pipes, should be accomplished by
professional to ensure the product can operate normally.
Perform installation according to the relative pipeline regulations and
the specification of Water Inlet, Water Outlet, Drain Outlet.
B. Device location
①The filter should be located close to drain.
②Ensure the unit is installed in enough space for operating and
maintenance.
③The unit should be kept away the heater, and not be exposed outdoor.
Sunshine or rain will cause the system damage.
④Do not install the filter or softener, drain pipeline in circumstance which
temperature may drop below 5℃, or above 50℃.
⑤One place is recommended to install the system which cause the
minimum loss in case of water leaking.
C. Pipeline installation(Taking F56A for example)
①Install control valve
a. As the Figure 1-1 shows, select the riser pipe with 26.7mm OD, glue
the riser pipe to the bottom strainer and put it into the mineral tank, cut off
the exceeding tube out of tank top opening. Plug the riser tube in case of
mineral entering.
b. Fill the filter material to the tank, and the height is accordance with the
design code.
c. Remove the tap covering on the central tube and check if the riser tube
is on the central of tank.
d. Install the top distributor to the valve and insert the riser tube into
control valve and screw tight control valve