INTRODUCTION
The TRV10RFM is a battery-powered, mini-size thermostatic radiator valve (TRV)
controller using ZigBee wireless communication. Simply replace the existing,
passive head on the standard radiator valve with the TRV10RFM (referred to
from now on as the unit). Use the unit with the VS10RF or VS20RF series of
wireless thermostats and a CO10RF wireless coordinator. The VS10RF or VS20RF
wireless thermostats are VS10BRF, VS10WRF, VS20BRF, and VS20WRF, where B
is the black model and W is the white model. You can optionally use the RX10RF
wireless boiler receiver and other iT600 wireless products.
Product Compliance
ThisproductisCEcompliantandmeetsthefollowingECDirectives:Electro-MagneticCompatibility
directive 2004/108/EC, R&TTE directive 1999/5/EC and ROHS2 directive 2011/65/EU.
Safety Information
Use in accordance with the regulations. The unit is to be used for the control of room temperature
inside the house.
Installation
This accessory must be tted by a competent person, and installation must comply with the
guidance, standards and regulations applicable to the country or state where the product is
installed. Failure to comply with the relevant standards could lead to prosecution.
VS10RF / VS20RF
Thermostat
(Required)
CO10RF
(Required)
RX10RF
(Optional)
SALUS Wiring Centre
KL08RF or KL10RF
TRV10RFM Instruction Manual 03

System Overview
To achieve the best control from the unit and thermostat, we recommend they
are used with the SALUS system receiver congured to RX1. The system receiver
will turn the boiler on or o when requested by the thermostat. See your boiler
receiver manual for more information about the RX1 conguration.
+
Up to three units can be connected to a VS10RF/VS20RF
The unit is modulating,
which means it opens
or closes partially
or 100% depending
on the relationship
between the actual
room temperature
and the required room
temperature measured
by the VS10/20RF.
04 TRV10RFM Instruction Manual

TRV10RFM Instruction Manual 05
Valve
1
32
Checking the compatibility of your heating system
The SALUS TRV10RFM is compatible with the majority of thermostatic radiator valves.
Before tting, please check your valve is suitable for use with the SALUS TRV.
Note: If all the measurements are as stated on this page then the TRV will
t directly to your valve. Also if your valve is not suitable please consider
changing your existing valves, contact your installer.
mm102030
mm102030
40
50
Remove the TRV head
Measure the thread
diameter (must measure
30mm)
Measure the pin length of the
valve when it is in the open
postilion. (must measure between
13-16mm)

06 TRV10RFM Instruction Manual
Checking the compatibility of your heating system
4
Our RA adapter also ts this valve.
Once tted the RA adapter should look like this.
If you can not see any thread on
the valve and it looks like this
picture, you may be able to use
the RA adapter supplied.

TRV10RFM Instruction Manual 07
1 2 3
4 5 6
Installing the Unit
Remove the battery door
on the side of the unit. Insert the batteries,
ensuring correct
orientation.
The LED on the unit ashes
green then flashes red
before changing to solid red.
When it is solid red, place
the unit over the radiator
valve using the mounting
ring if needed:
Screw the units nut
(finger tight) to the
radiator valve and check
that the LED is solid red.
The unit is now ready
for pairing to the SALUS
thermostat. You may now
start the pairing process
described on page 8.
Press any button on the
unit to adapt it to the
radiator valve. Once all
adaptation noise and LED
activity has stopped, the
unit is ready to pair with
your wireless thermostat.
See “LED Indications”
on page 12 if the LED
continues to ash.

08 TRV10RFM Instruction Manual
Preparing to Pair the Unit
1
Press and hold the button on the
CO10RF coordinator for ve seconds.
This puts the coordinator in pairing
mode. See your CO10RF Coordinator
manual for more information.
2
Ensure the wireless thermostat is powered up and ready for
pairing. See your thermostat manual for more information.
3
If you are using the optional RX10RF wireless boiler receiver
congured for remote boiler switching, ensure this has been
powered up and the red LED has gone from ashing to steady. See
your boiler receiver manual for more information.

TRV10RFM Instruction Manual 09
1
2
3
Pairing the Unit
Press and hold the pairing button for
10 seconds. You can pair up to three units with
one thermostat. Pair the units room by room.
Read page 38 to 40 of your wireless thermostat
manual when the red LED on the unit starts to
ash.
You have paired the unit to the thermostat when the unit LED goes o.
Once paired, the unit operates in automatic mode and receives room
temperatures from the thermostat.

10 TRV10RFM Instruction Manual
LED Indication
Pairing Button
Manual open/
status indication
Manual close/
status indication
Leaving the Network
Using the Unit
Once paired to a thermostat, press and
hold the pairing button on the unit for 10
seconds.
The red and green status LEDs come on
together for one second.
Note: After you have deleted the unit from
the wireless network, you must reinstall it
using the instructions from page 5.

TRV10RFM Instruction Manual 11
Using the Unit
Auto Lock Function
Auto lock function is disabled until you have gone through the pairing process.
After pairing, the TRV will auto lock after 5 minute if no buttons have been
pressed.
Unlocking the Buttons
To unlock the buttons, press the pairing and close buttons together for
3 seconds.
Opening the Valve Manually
Press the open button for 3 seconds. The LED ashes green once and the
valve opens.
Closing the Valve Manually
Press the close button for 3 seconds. The LED flashes red once and the
valve closes.
Entering Fail Safe Mode
In fail safe mode, the unit opens the valve 25% for water ow to maintain
room temperature.
To enter fail safe mode, press and hold the open and close buttons together
for 3 seconds.
To exit fail safe mode, press the:
• Pairing button to put the unit in automatic mode
• Open button for 3 seconds to open the valve
• Close button for 3 seconds to close the valve

12 TRV10RFM Instruction Manual
Using the Unit
Restoring Factory Default Settings
Press the pairing, open, and close buttons together for 10 seconds.
Protecting against Frost
When you have manually closed the valve, the unit automatically enables frost
protection. Frost protection starts only when the temperature in the room drops
below the frost temperature setpoint. The unit does all this automatically when
connected to a thermostat and you don’t have to do anything.
Detecting Open Windows
The unit checks the rate of temperature drop in the room in which it is located.
If the drop is rapid, it assumes a window in the room has been opened. This only
works if the unit is paired to the thermostat and is in automatic mode and the
battery in the unit is not low. The unit does all this automatically when connected
to a thermostat and you don’t have to do anything. It works between 0 and 40⁰C.
Protecting against Lime Scale
Do not leave a valve open for a long time because this could cause a build up
of lime scale. The unit has a lime-scale protection feature to prevent against
this. The valve motor automatically starts once a week if no valve movement
has been detected within a 14-day period. Lime-scale protection will continue
to operate in automatic, manual open, and manual close modes and you don’t
have to do anything.
Auto Adaptation
Once the batteries are inserted into the unit, the red light will appear. If no keys
are pressed it will auto adapt to the valve.

TRV10RFM Instruction Manual 13
Button Usage
To do this… Press the…
Leave the network Pairing button for 10 seconds
(when unit already in network)
Pair with thermostat Pairing button for 10 seconds
Put unit in automatic mode Short press Pairing button
Fully open the valve Open button for 3 seconds
Fully close the valve Close button for 3 seconds
Restore factory default settings Open, pairing, and close buttons together
for 3 seconds
Lock and unlock the buttons Pairing and close buttons together
for 3 seconds

14 TRV10RFM Instruction Manual
LED Indications
When... The LEDs... Valve
Power switched
on or after reset
Unit adapting
to valve
Unit has not
joined network
or has not paired
to thermostat
Unit paired to
thermostat and
in auto mode
Leaving network
Identifying the
network
Software Version
indication
Auto mode
Manual open
Manual close
A sequence of red and green
LEDs ashing displayed
indicates the software version
Red ashes then goes steady
Green ashes (or red ashes
on failure to adapt)
Green steady
Green and red ash (or red
ashes on failure to adapt)
Green and red ash alternately
after short press on open or
close button
Green ashes twice after short
press on open or close button
Red ashes twice after short
press on open or close button
No LED
Red and green on together for
25% open
100% open
0% open

TRV10RFM Instruction Manual 15
When... The LEDs... Valve
Wireless
link to thermostat
lost
Normal
operation
Battery low
Error installing
Auto mode
Manual open
Manual close
Auto mode
Auto mode
Manual open
Manual close
Window open
mode active
Green and red ash alternately
after short press on open or
close button
Green ashes twice after short
press on open or close button
Red ashes twice after short
press on open or close button
Green ashes once after short
press on open or close button
Red ashes once after short
press on open or close button
Green ashes twice after short
press on open or close button
Red ashes twice after short
press on open or close button
Green and red ash twice
every 10 seconds
Red ashes three times every
10 seconds (less if the battery
is low)
Green and red ash alternately
100% open
0% open
1 to
100% open
0% open
100% open
0% open
100% open
25% open
LED Indications

16 TRV10RFM Instruction Manual
Long press to
manually open LED ashes green once and then goes out.
To check status refer to previous page.
Long press to
manually close LED ashes red once and then goes out.
To check status refer to previous page.
Short press to return to Auto mode.
Red LED will ash once to conrm that
the unit is in AUTO.
Manual Override
To remove the unit from auto mode, follow the steps below. If the buttons
are locked, unlock them by pressing the pairing and close buttons together
for 3 seconds.

TRV10RFM Instruction Manual 17
Technical Detail
Model TRV10RFM
Type Hydraulic Radiator Valve
DC Motor
M30 x 1.5
Input Three push buttons:
LED Indicator Bi-Colour, Red/Green
Valve Adaptation Automatic
Power Source 2x AA Batteries
Battery Life 14 Months (low battery indication)
Control Method Modulating
Communication 2.4GHz ZigBee wireless
Operating Temperature 0 to 45ºC
Storage Temperature -20 to 60ºC
Operating Humidity 5 to 95”RH
Protection IP30
Size (mm) H 88.6, W 51
• Manual open/status indication
• Manual close/status indication
• Pairing

Notes
18 TRV10RFM Instruction Manual

SALUS Controls warrants that this product will be free from any defect in materials or
workmanship, and shall perform in accordance with its specication, for a period of ve
years from the date of installation. SALUS Controls sole liability for breach of this warranty
will be (at its option) to repair or replace the defective product.
Customer Name: .......................................................................................
Customer Address: ....................................................................................
....................................................... Post Code: ..........................................
Tel No: .......................................................................................................
Email: ........................................................................................................
Engineers Company: ..................................................................................
Tel No: .......................................................................................................
Email: ........................................................................................................
Instalation Date: ........................................................................................
Engineers Name: .......................................................................................
Engineers Signature: ..................................................................................
Warranty
TRV10RFM Instruction Manual 19

www.salusna.com
SALUS North America
850 Main Street
Redwood City
CA 94063
T: +1-650-360-1725
Maintaining a policy of continuous product development, SALUS Controls
plc reserves the right to change specication, design and materials of
products listed in this brochure without prior notice.
SALUS Controls is a member of the Computime Group
Issue Date: Dec 2014
00086/2
For PDF Instruction Manual go to
www.salus-controls.com
Other manuals for TRV10RFM
2
Table of contents
Other Salus Controllers manuals

Salus
Salus EP110 User manual

Salus
Salus PC11W User manual

Salus
Salus PCSol 201 User manual

Salus
Salus KL04NSB User manual

Salus
Salus SP220 User manual

Salus
Salus Multi-Mix Specification sheet

Salus
Salus RX10RF User manual

Salus
Salus AH2430 User manual

Salus
Salus RX10RF User manual

Salus
Salus AKL04P User manual
Popular Controllers manuals by other brands

MRC
MRC Railpower 1300 manual

Hubbell
Hubbell Electric Fire Pump Controllers LXi 1700 Specifications

IFM Electronic
IFM Electronic ecomat100 CR0033 installation instructions

National Instruments
National Instruments cRIO-9030 user manual

Controlli
Controlli DG501C user guide

Topmodel
Topmodel XPower XREG80HV user manual