Salus EP210 User manual

Installation Manual
Model: EP210
Dual channel programmable controller

Introduction ................................................................................................................. 3
Product Compliance ............................................................................................... 4
Safety Information ................................................................................................... 4
Box content .................................................................................................................. 4
Features .......................................................................................................................... 5
Installation ..................................................................................................................... 5
Button functions ....................................................................................................... 7
LCD icons ....................................................................................................................... 8
Operations .................................................................................................................... 9
Functions ....................................................................................................................... 18
Factory Reset ............................................................................................................... 21
Technical Info .............................................................................................................. 22
Warranty ......................................................................................................................... 23
Contents
02 EP210 Installation Manual

Introduction
The EP210 dual channel programmable controller is a stylish wired timer that can be used for central heating
and also for the hot water. Each output will control one zone, meaning that you can create personalized
schedules for each channel.
The EP210 programmable controller will switch ON and OFF your central heating system and/or hot water in
your home as needed. It works by controlling the heating boiler according to a series of programmed settings
that take effect at different times of the day.
By using the EP210 controller you can manage the commands sent to your boiler, motorized valves used in
your system or to your thermostat. You can set the EP210 programmable controller to a 12 or 24 hour format,
the Daylight saving Time (DST) being automatically enabled. The program mode is also selectable between a
5-2 (Monday-Friday and Saturday-Sunday) or 24 hour format. For each of the programs you can create three
settings per day.
Being a complex programmable controller, the EP210 gives you the possibility to override your programs by
using the Boost function. This can be enabled for up to 9 hours.
For the periods when you are away you can use the Holiday function, which will turn off the relay. The Holiday
Mode can be set for a period of maximum 31 days.
When connected to a system with a non-programmable (digital) thermostat, it can turn the boiler ON or OFF
and control the heating and/or hot water in your system in a programmed manner.
The heating system and the hot water will be controlled with the EP210, meaning that this will send the
command of turning the relay on or off when needed, according to the programs created.
The EP210 programmable controller does not detect or adjust the temperature in your house, it is just sending
the commands to the boiler, motorized valve or the thermostat to turn ON or OFF the relay, depending on the
program settings.
The programs can be set individually for each channel, or, you can program them together if you want your
heating and hot water to be controlled in a coordinated manner.
EP210 Installation Manual 03

Product compliance
Safety Information
Box content
This product complies with the essential requirements and other relevant provisions of the following EU
Directives: 2014/30/EU, 2014/35/EU and 2011/65/EU. Please check www.saluslegal.com for the full information.
Use in accordance with the EU and national regulations. For indoor use only. Keep your device completely
dry. This product must be installed by a competent person and in accordance with all the EU and national
regulations.
Always isolate the AC Mains supply before installing or working on any components that
require 230 VAC 50Hz supply.
The box includes the EP210 controller, 2X screws and plugs and the Quick Guide installation manual.
Backlight/
Holiday
Mode
+1Hr
Down
Up
Select
Set
Reset
Installer Manual-Quick Guide
Always isolate the AC Mains supply before installing or working on any components
that require 230 VAC 50Hz supply.
Introduction
A programmable controller is used to switch the heating system and/or
the hot water in your home on and off as needed. It works by controlling
the central heating and/or the hot water with programmed settings that
take effect at different times of the day.
Go to www.salus-manuals.com for the full PDF version of the manual.
Product Compliance
EU Directives: 2014/30/EU, 2014/35/EU and 2011/65/EU. Please check
www.saluslegal.com for the full information.
Safety Information
Use in accordance with the EU and national regulations.
For indoor use only.
Keep your device completely dry.
This product must be installed by a competent person and in accordance
with all the EU and national regulations.
Difference between EP110/EP210/EP310
Installation Jumper Settings
First Power Up
Button Function
The EP line will offer you the possibility to customize your central heating system
and hot water system as desired.
EP110 is recommended for users that want to control only the Central Heating or
the Hot Water system.
EP210 is designed to give you a full control with only one device of both your
Central Heating and Hot Water system.
EP310 is the most versatile product of this line and lets you manage two different
Central Heating zones and the Hot Water with only one controller.
Model: EP110/EP210/EP310
Input: 230V, 50Hz
Output: 3A/ switch terminal
1
2
3
EP110 Volt Free application only
EP210 - 230V Application
EP310 - 230V Application
EP110 - 230V Application Only
Note: Please remove red link wire for this application.
Terminal Description Backplate
N Mains Neutral
L Mains Live
1 Not Used
2 Not Used
3 Volt Free Connection
4 Volt Free Connection
Earth Parking
(no electrical connection)
NL1234
NL123456
Terminal Description Backplate
N Mains Neutral
L Mains Live
1 NC (Output)
2 Not Used
3 Switch Live (Output)
4 230V Common (via Link)
Earth Parking
(no electrical connection)
NL1234
NL123456
Terminal Description Backplate
N Mains Neutral
L Mains Live
1 Hot Water O
2 Central Heating O
3 Hot Water On
4 Central Heating On
Earth Parking
(no electrical connection)
NL1234
NL123456
Terminal Description Backplate
N Mains Neutral
L Mains Live
1 Hot Water O
2 Central Heating O
3 Hot Water On
4 Central Heating 1 On
5 Central Heating 2 On
6 Central Heating 2 O
Earth Parking
(no electrical connection)
NL1234
NL123456
Changes to the jumpers settings should only be made by the Engineer carrying
out the installation or other qualified person. The installer should select the jumper
positions required if changes need to be made to the factory default settings.
These jumpers are found on the rear of the controller.
* P - Fully pumped system for independent Central Heating and Hot Water.
* G - Gravity Hot Water system with Pumped Central Heating.
EP110/ EP210/ EP310 Switching Bridges
Switch
Program 5-2 days programme or
24h programme
Fully pumped system(P*)
or gravity-fed hot water
system(G*)
Disable/enable the internal
backup battery
System
Feature EP110/310 Settings
Memory
Backup
5-2 24H 24H
5-2
NA NA
PG
OFF ON OFF ON
EP210 Settings
EP110/EP310 EP210
EP110 EP310
EP210
1. Turn on the LCD backlight
2. Press for 3 sec to activate Holiday mode
Select operating mode (ON, ONCE, AUTO, ADV, OFF)
Activate/deactivate Boost function
Decreases the selected setting
Increases the selected setting
Select a clock or programme setting
Sets a clock or programme setting
Reset to Factory settings
EP110
CH or HW
EP210
CH and HW
EP310
2x CH and 1x HW
MODE
SELECT
SET
+HR
2x screws and plugsEP210 Controller
Quick Guide Installation
04 EP210 Installation Manual

Installation
Wiring and terminal description
Terminal Description Backplate
N Mains Neutral
L Mains Live
1 Hot Water O
2 Central Heating O
3 Hot Water On
4 Central Heating On
Earth Parking
(no electrical connection)
NL1234
NL123456
Features
• Dual Channel Programmer for Central Heater or Hot Water
• 12 or 24 hour clock format
• 5+2 or 24 h individual programs with 3 settings per day
• Boost function
• Holiday function
• Advance function
• Memory backup
NL123 4
N L HW CH HW CH
(o) (o) (on) (on)
EP210 Installation Manual 05

Fix the backplate to the wall. Align the front housing
at the top edge.
Fit the front housing. Press lightly.
Wall mounting
Jumper settings
EP210 Switching Bridges
Switch Feature Setting Default
System Fully pumped
system(P*)or gravity-
fed hot water
system(G*)
P G Fully pumped and
controlled system
Program 5-2 days program or
24h program 5-2 24H 5-2 days program
Memory Backup Disable/enable the
internal backup
battery
OFF ON Internal backup
battery disabled
Note: Changes to the jumper setting should only be made by the engineer carrying out the installation or another
qualified person. The installer should select the jumper positions required if changes need to be made to the factory
default settings. These jumpers are found on the rear of the controller.
The jumpers are found on the rear of your controller and can be used to change the
settings for the: program type, system type (fully pumped and controlled or gravity-
fed) and internal backup memory battery. If you want to change the position of the
jumpers, please note that you will need to reset your device.
06 EP210 Installation Manual

Button functions
Key Function
Mode Press to select ON/ONCE/AUTO/ADV/OFF for hot water
Mode Press to select ON/ONCE/AUTO/ADV/OFF for heating
+Hr Press to enter/cancel Boost override function by setting
Boost hours.
Select Press to select the setting of clock/date/week day, etc.
Set Press to confirm the setting.
Up arrow Press to increase clock/day, press and hold to enter fast
advance.
Down arrow Press to decrease clock/day, press and hold to enter fast
advance.
Press to activate backlight.
Hardware reset
Press and hold button for 3 seconds to activate Holiday
mode.
Select + Set Press and hold buttons to enter clock setting mode.
MODE
MODE +Hr
+Hr
SELECT SET
<
<
EP210 Installation Manual 07

CH strip
HW strip
LCD icons
Clock
Heating zone
Boost hours for heating
Holiday Mode
Boost hours for hot water
AM/PM
1
2
3
4
5
6
7
Days of the week
12 3
4
5
6
7
891011121314
15
OFF Mode
ADV Mode On
AUTO Mode On
ONCE Mode On
On Mode
DST On/Off
8
9
10
11
12
13
14
Hot Water On
15 Program number
08 EP210 Installation Manual

Operations
Initial power up
After power up or after RESET is pressed, the programmer is reset to factory default settings. During system
reset, all LCD icons and segments are turned on for 2 seconds and all keys are blocked. After 2 seconds and all
keys are released, the programmer is initialized. First the software version is shown and after that the typical
reset display is shown. The time should be 12:00am.
Default settings
MODE
MODE +Hr
+Hr
SELECT SET
<
<
MODE
MODE +Hr
+Hr
SELECT SET
<
<
MODE
MODE +Hr
+Hr
SELECT SET
<
<
Function Status after Reset
Operation Mode Normal mode
Clock 12:00 AM
AM/PM indicator AM
Date January 1, 2016
Daylight Saving Time(DST) On
Program Factory default 5+2
Program Number indicator Off
SET indicator Off
PROG indicator Off
Mode indicator(s) “Off“
Output Relay Off
CH/HW indicator(s) Off
EP210 Installation Manual 09

MODE
MODE +Hr
+Hr
SELECT SET
<
<
MODE
MODE +Hr
+Hr
SELECT SET
<
<
MODE
MODE +Hr
+Hr
SELECT SET
<
<
MODE
MODE +Hr
+Hr
SELECT SET
<
<
MODE
MODE +Hr
+Hr
SELECT SET
<
<
Setting time and date
3 sec
Choose your clock format
Press Up/Down arrow for
12/24 hr format.
Press Up or Down to
set the hour.
Press Up or Down to
set the minutes.
Press and hold the indicated
buttons together for 3 sec.
The first thing you will have to do is to set the time and date on your controller. First you will need to set up
the time and then the date. To enter clock setting mode, press and hold Select and Set buttons for 3 seconds.
Please follow the instructions below.
Press Select to confirm.
MODE
MODE +Hr
+Hr
SELECT SET
<
<
MODE
MODE +Hr
+Hr
SELECT SET
<
<
Press Select to confirm.
MODE
MODE +Hr
+Hr
SELECT SET
<
<
Press Select to confirm.
MODE
MODE +Hr
+Hr
SELECT SET
<
<
MODE
MODE +Hr
+Hr
SELECT SET
<
<
MODE
MODE +Hr
+Hr
SELECT SET
<
<
Press Up or Down to
set the year.
Press Select to confirm.
Press Up or Down
to set the month.
MODE
MODE +Hr
+Hr
SELECT SET
<
<
Press Select to confirm. Press Up or Down
to set the date.
10 EP210 Installation Manual

MODE
MODE +Hr
+Hr
SELECT SET
<
<
MODE
MODE +Hr
+Hr
SELECT SET
<
<
MODE
MODE +Hr
+Hr
SELECT SET
<
<
Press Select to confirm. Press Up or Down to
select DST on/off.
Press Set to confirm and
exit to normal mode.
EP210 can operate in 5 different modes, applicable to the CH, HW or CH+HW. The operation modes are the
same for CH and HW and can be set individually, or together. If you want to choose the mode for the CH, press
the Mode key. If you want to choose the mode for the HW, press the Mode Key.
Operation Mode Function
ON Continuously on
ONCE On for 1 period a day, from Program 1 ON to Program 3 OFF
AUTO Automatic program control
ADV
When device is in Auto or Once mode, press the MODE button for 3 sec for
selecting Advance (ADV). This will move the unit into the next program. When
the ADV function ends the device will return to normal program.
OFF Continuously off
Operating Modes
For activating the functions described above, press the MODE button. The operating mode is cycled in the
below sequence:
When Daylight saving time is enabled, the clock will automatically change from Greenwich Mean Time (GMT)
to British Summer Time (BST) on the last Sunday in March. The clock will automatically change back to GMT on
the last Sunday in October.
EP210 Installation Manual 11

MODE
MODE +Hr
+Hr
SELECT SET
<
<
MODE
MODE +Hr
+Hr
SELECT SET
<
<
MODE
MODE +Hr
+Hr
SELECT SET
<
<
ON Mode
Pressing the Mode key once activates the ON Mode. In ON mode, the controller gives the boiler the ON
command, so the heating or/and hot water will run continuously.
Pressing the Mode key twice activate the ONCE Mode. In ONCE mode, the controller gives the boiler the
command to run only for one period per day (from program 1 ON to program 3 OFF)
MODE
MODE +Hr
+Hr
SELECT SET
<
<
MODE
MODE +Hr
+Hr
SELECT SET
<
<
Press for CH mode. Press for HW mode.
MODE
MODE +Hr
+Hr
SELECT SET
<
<
Press for CH mode. Press for HW mode.
ONCE Mode
Auto Mode
Press for CH mode. Press for HW mode.
Pressing the Mode key 3 times activates the AUTO. In AUTO mode, the controller gives the boiler the ON/OFF
command depending on your schedule.
12 EP210 Installation Manual

OFF Mode
Pressing the Mode key 4 times activates the OFF Mode. In OFF mode, the controller gives the boiler the OFF
command, so the heating or the hot water will be turned off.
ADV Mode
Note: In ONCE or AUTO mode, by long pressing the MODE button, the controller will switch automatically to
ADV. You can cancel the ADV by long pressing the MODE key. The device will then return to ONCE or AUTO
mode. You can’t select ADV by pressing Mode key
When in Auto mode selecting ADV, the controller will simply toggle the current auto setting (ON or OFF). For
example, if the current program is set as:
08:00 ON 09:00 OFF 10:00 ON 11:00 OFF
Selecting ADV between 8:00 and 8:59 will change the output to OFF, from 9:00 onwards back to AUTO (which
is also OFF). Selecting ADV between 9:00 and 09:59 will change the output to ON, from 10:00 onwards back to
AUTO (which is also ON). If the ADV puts the relay ON then the boost would apply immediately at the next OFF
change, if the ADV put the relay OFF then the boost would apply immediately and turn the relay ON.
08:00 OFF 10:00 ON 12:00 OFF 14:00 ON
If ADV occurs at 08:30 and the relay is ON from 08:30 to 12:00. During this period, if at 08:45 +1Hr (Boost) is
pressed, the relay will be ON from 08:30 to 12:00. Boost is applied immediately ie. from 08:45 to 09:45 at the next
change, ie. 12:00. If ADV occurred at 10:30 the relay will be ON from 10:00, OFF from 10:30 (ADV) to 14:00 if no
+1Hr Override. During ADV, if at 10:45 +1Hr (Boost) is pressed, the relay will go ON again at 10:45 (boost starts),
OFF at 11:45 (Boost ends) until ends at 14:00, then ON again at 14:00.
MODE
MODE +Hr
+Hr
SELECT SET
<
<
MODE
MODE +Hr
+Hr
SELECT SET
<
<
Press for CH mode. Press for HW mode.
MODE
MODE +Hr
+Hr
SELECT SET
<
<
MODE
MODE +Hr
+Hr
SELECT SET
<
<
Press for CH mode. Press for HW mode..g
EP210 Installation Manual 13

5-2 Days Program Individual Days Program
Weekdays
3 sets of time/channel
Weekends
3 sets of time/channel
Total: 12 settings/week
1 Day
3 sets of time/channel
Total: 42 settings/week
Programming the EP210
2 types of programs can be set:
• 5+2 (Mon to Fri same and Sat, Sun same)
• Different programs for each 24h.
There are 3 different time sets for each day.
EP210 is a dual channel controller, that gives the possibility to control both Central Heating and Hot Water. You
can choose which one you would like to control, by simply pressing the Mode key for Central Heating,
or Mode key for hot Water, or you can use both. You can program the schedules for these outputs
individually or together. When you program them together, there will be the same program time for both
Heating and Hot Water. If you choose to program them individually, you can have different program times for
each.
5+2 Program
MODE
MODE +Hr
+Hr
SELECT SET
<
<
Press Set to enter
setting programs
MODE
MODE +Hr
+Hr
SELECT SET
<
<
The CH icon and Mon-Fr will
start flashing. Tap Select.
MODE
MODE +Hr
+Hr
SELECT SET
<
<
The CH icon will go steady, the
program number will appear
and you will need to select a
start time for the CH program.
Use up/down arrows.
Programing CH and HW individually
MODE
MODE +Hr
+Hr
SELECT SET
<
<
6
Press Select.
MODE
MODE +Hr
+Hr
SELECT SET
<
<
Use up/down arrows
to select minutes.
6MODE
MODE +Hr
+Hr
SELECT SET
<
<
6
Press Select.
12 3
4 5 6
66
14 EP210 Installation Manual

MODE
MODE +Hr
+Hr
SELECT SET
<
<
8
MODE
MODE +Hr
+Hr
SELECT SET
<
<
8
Press Select.
MODE
MODE +Hr
+Hr
SELECT SET
<
<
Use up/down arrows to
select minutes.
8
Controller will now
go to program nr 2.
MODE
MODE +Hr
+Hr
SELECT SET
<
<
8
Select an end time for
the first program.
MODE
MODE +Hr
+Hr
SELECT SET
<
<
8
Press Select.
Please continue by following the same
steps for program nr 2 and 3. After you
finish programming CH for weekdays,
the controller will ask you to do the
same thing for the Hot Water. You can
choose different or similar end/start
time. The LCD will look like step 12.
MODE
MODE +Hr
+Hr
SELECT SET
<
<
6
The sequences followed by the controller when programming CH
and HW individually goes at it follows:
Weekday CH (program 1-3) Weekday HW (program 1-3)
Weekend CH (program 1-3) Weekend HW (program 1-3) and all
over again.
Note: To save your settings and exist to home screen in normal mode, press Set at any time.
Programming CH and HW together
The programming principle is exactly the same, but you can only set the same Start/End time for the CH and
HW. The programming sequence goes as it follows: Weekday CH+HW Weekend CH+HW and all over
again. To program them together, follow the steps:
MODE
MODE +Hr
+Hr
SELECT SET
<
<
Press Set to enter
setting programs .
MODE
MODE +Hr
+Hr
SELECT SET
<
<
The CH icon and Mon-Fr
will start flashing. Press up
arrow 2 times.
MODE
MODE +Hr
+Hr
SELECT SET
<
<
Press Select to start entering a
start time for the program and
then follow the same steps as
above from 3-11.
6
6
1 2 3
45
6
EP210 Installation Manual 15

Setting dierent programs for each 24h
Note: Don’t forget to move the jumpers to 24h in order to have the individual program active.
After that please follow the same instructions as for the 5-2 days program.
MODE
MODE +Hr
+Hr
SELECT SET
<
<
Press Set to enter
setting programs
MODE
MODE +Hr
+Hr
SELECT SET
<
<
The CH icon and Mon will
start flashing. Tap Select.
MODE
MODE +Hr
+Hr
SELECT SET
<
<
The CH icon will go steady,
the program number will
appear and you will need to
select a start time for the CH
program. Use up/
down arrows.
Programming CH and HW individually
6
MODE
MODE +Hr
+Hr
SELECT SET
<
<
6
Press Select.
MODE
MODE +Hr
+Hr
SELECT SET
<
<
Use up/down arrows
to select minutes.
6MODE
MODE +Hr
+Hr
SELECT SET
<
<
6
Press Select.
6
MODE
MODE +Hr
+Hr
SELECT SET
<
<
8
Press Select.
MODE
MODE +Hr
+Hr
SELECT SET
<
<
Use up/down arrows
to select minutes.
8
MODE
MODE +Hr
+Hr
SELECT SET
<
<
8
Select an end time for
the first program.
1
4
7
2
5
8
3
6
9
16 EP210 Installation Manual

MODE
MODE +Hr
+Hr
SELECT SET
<
<
8
Controller will now
go to program nr 2
MODE
MODE +Hr
+Hr
SELECT SET
<
<
8
Press Select.
Please continue by following the
same steps for program nr 2 and 3.
After you finish programing CH for
Monday, the controller will ask you to
do the same thing for the Hot Water.
You can choose different or similar end/
start time. The LCD will look like step 12.
MODE
MODE +Hr
+Hr
SELECT SET
<
<
6
The sequences followed by the controller when programming CH
and HW individually goes at it follows:
Monday CH (program 1-3) Monday HW (program 1-3)
Tuesday CH (program 1-3) Tuesday HW (program 1-3)
Wednesday CH (program 1-3) Wednesday HW (program 1-3) etc
Note: To save your settings and exist to home screen in normal mode, press Set at any time.
Programming CH and HW together
MODE
MODE +Hr
+Hr
SELECT SET
<
<
Press Set to enter setting
programs .
MODE
MODE +Hr
+Hr
SELECT SET
<
<
The CH icon and Mon will start
flashing. Press up arrow 2 times.
MODE
MODE +Hr
+Hr
SELECT SET
<
<
Press Select to start entering
a start time for the program
and then follow the same
steps as above from 3-11.
6
6
The programming principle is exactly the same, but you can only set the same Start/End time for the CH and
HW. The programming sequence goes as it follows: Monday CH+HW Tuesday CH+HW Wednesday
CH+HW etc.
To program them together, follow the steps:
10
12
11
EP210 Installation Manual 17

Functions
Temporary Override
Boost Override (+1Hr override)
Boost Override (+1Hr override) is available in ONCE/AUTO/OFF modes. Boost mode can be activated even in
ADV mode. When boost mode is activated , ADV is canceled. Press +1Hr at current mode to activate the Boost
Override (+1Hr override) setting mode. Boost mode increases the time of the active program by 1-9 hours.
The new setting hour “+x” (x=last boost hour+1 hour) is displayed. Subsequent press of +1Hr will increase
the duration by 1 hour. Maximum duration is 9 hours. If the number rolls back to blank, this will disable
the Boost Override.
Press +1Hr to enter
Boost override.
The number of boost hours
will be displayed.
To exit boost override, press
mode button until number
+x disappears.
MODE
MODE +Hr
+Hr
SELECT SET
<
<
Boost Override (+1Hr override) for Heating
MODE
MODE +Hr
+Hr
SELECT SET
<
<
+1
MODE
MODE +Hr
+Hr
SELECT SET
<
<
Press +1Hr to enter
Boost override.
The number of boost hours
will be displayed.
To exit boost override, press
mode button until number
+x disappears.
MODE
MODE +Hr
+Hr
SELECT SET
<
<
MODE
MODE +Hr
+Hr
SELECT SET
<
<
MODE
MODE +Hr
+Hr
SELECT SET
<
<
Boost Override (+1Hr override) for Hot Water
+1
Boost Override (+1Hr override) can be available for CH and HW at the same time.
18 EP210 Installation Manual

MODE
MODE +Hr
+Hr
SELECT SET
<
<
ADV Override
ADV only works in AUTO or ONCE mode. During ADV, press MODE once to cancel ADV and go back to AUTO
/ONCE mode after LCD backlight is turned off.
+1Hr override and ADV cannot co-exist in same channel. During ADV mode, when +1Hr is pressed, override
mode will cancel ADV mode then change to Boost mode. If +1Hr override (Boost) is running, then ADV is
selected, ADV will be activated and the previous +1Hr override will be canceled.
Long press Mode while in Auto or
Once to enter ADV override Mode.
Short press Mode while in ADV to
exit mode back to auto or Once.
ADV Override for Heating
ADV Override for Hot Water
MODE
MODE +Hr
+Hr
SELECT SET
<
<
Long press Mode while in Auto or
Once to enter ADV override Mode. Short press Mode while in ADV to
exit mode back to auto or Once.
MODE
MODE +Hr
+Hr
SELECT SET
<
<
MODE
MODE +Hr
+Hr
SELECT SET
<
<
EP210 Installation Manual 19

MODE
MODE +Hr
+Hr
SELECT SET
<
<
MODE
MODE +Hr
+Hr
SELECT SET
<
<
Holiday Override
During the period of holiday override, relay should be always Off.
Press and hold at current mode for 3 seconds to activate the Holiday Override setting mode.
The plane icon will be displayed on the LCD and the user’s only option will be to set the number of holiday
days (up to 31). To exit Holiday Override and turn On the relay, long press the key.
Press Up/Down keys
to select days.
Enter Holiday Mode
Exit Holiday Mode
Press for 3 seconds.
Press for 3 seconds. Controller in current mode.
LCD Backlight
If AC is powered, LCD backlight is activated when or any key is pressed. The backlight will be turned off in
15 seconds after all keys are released.
3 sec
MODE
MODE +Hr
+Hr
SELECT SET
<
<
MODE
MODE +Hr
+Hr
SELECT SET
<
<
3 sec
20 EP210 Installation Manual
Table of contents
Other Salus Controllers manuals

Salus
Salus THB23030 User manual

Salus
Salus RX10RF User manual

Salus
Salus EP310 User manual

Salus
Salus PC12HW User manual

Salus
Salus PC11 User manual

Salus
Salus TRV10RFM-3 User manual

Salus
Salus PC11W User manual

Salus
Salus PCSol 150 User manual

Salus
Salus TRV10RFM User manual

Salus
Salus Multi-Mix Specification sheet