Rear Panel
Press and hold for 5 seconds while powered
On to clear network settings. Status LED will
blink rapidly when reset is complete.
8-pin RJ-45 female.
10/100 Base-T auto-negotiating port with
Link/Activity LEDs:
See items C and D for LED functionality.
Supports Power over Ethernet using PoE
IEEE 802.3af
Off: Ethernet link is not established.
Green: Ethernet link is established.
Green Blinking: Ethernet activity is occurring.
Off: 10 Mbps data rate
Green: 100 Mbps data rate
8-pin RJ-45 female.
Used to transmit and receive serial binary
data to and from serial controllable devices.
Ports 1-4 RS-232 /RS-422
CTS/RTS handshaking.
Ports 5-8 RS-232/RS-422/RS-485
CTS/RTS handshaking.
CTS/RTS Handshaking availability based on
component profile.
See RS-232/422/485 Wiring for pinouts.
6-pin Screw Down Plug-in Connector.
Used to send IR signals to control devices
with an IR input or IR receiver via an IR
flasher (5V tolerant only). See IR Wiring for
important precautions regarding IR
functionality before making any connections.
9-pin Screw Down Plug-in Connector.
See Relay Wiring for pinouts.
Normally Open (NO) Normally Closed (NC)
to control devices requiring basic on/off
operation. DC Voltage Max: 30V DC 1A.
9-pin Screw Down Plug-in Connector.
See GPIO Wiring for pinouts.
GPIO Input: When configured as an input,
the processor will look for a low (<0.8V DC)
or a high (>2.4V DC ) state.
Minimum 0V DC / Maximum 12V DC
GPIO Output: When configured as an
output, the port provides a binary output of
0-12V DC 150mA max.
Ground Connector - used to connect to a
suitable ground reference when using Power
over Ethernet (PoE).
12V DC 1.25A - Connect to power supply
when not using PoE.
Wiring and Connections
RS-232/422/485 Wiring
When making connections, label the cables with the source and
destination. This will make modifications and troubleshooting easier.
RS-232 Pinouts
Note: CTS/RTS Handshaking availability based on component profile.
RS-422/RS-485 Pinouts
RJ-45 to DB9 Adapters
Savant offers RJ-45 to DB9 adapters in a variety of configurations
that can be used for RS-232/422/485 control.
Refer to the RS-232 Conversion to DB9 and RS-422/485 Pinout
Application Note located on the Savant Customer Community for
more information on RJ-45 to DB9 adapters.
IMPORTANT!
If you are using RJ-45 to DB9 adapters not supplied by Savant:
•Ensure that any wires required for communication/control are
terminated within the adapter.
•Ensure that all wires NOT required for communication/control
are NOT terminated in the connector.
•Ensure that the unused wires in the connector are cut to prevent
them shorting out, as they are still terminated in the RJ-45
connector on the controller side.
SSC-P025-11 | 009-1259-02 | 151023
SSC-P025-11 | 009-1259-02 | 151023
45 Perseverance Way, Hyannis, MA 02601
Copyright © 2015 Savant Systems, LLC
savant.com | 508.683.2500