manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Savant
  6. •
  7. Controllers
  8. •
  9. Savant SmartControl 25 User manual

Savant SmartControl 25 User manual

Other Savant Controllers manuals

Savant Director HST-DIRECTOR User manual

Savant

Savant Director HST-DIRECTOR User manual

Savant S2 Quick reference guide

Savant

Savant S2 Quick reference guide

Savant LCB-DMX1 Quick reference guide

Savant

Savant LCB-DMX1 Quick reference guide

Savant SSC-0012 Quick reference guide

Savant

Savant SSC-0012 Quick reference guide

Savant SmartControl 3 User manual

Savant

Savant SmartControl 3 User manual

Savant Savant SmartLighting 2 User manual

Savant

Savant Savant SmartLighting 2 User manual

Savant QO PBC-1000-10 Quick reference guide

Savant

Savant QO PBC-1000-10 Quick reference guide

Savant WIF S104 Series User manual

Savant

Savant WIF S104 Series User manual

Savant SmartControl 3 User manual

Savant

Savant SmartControl 3 User manual

Savant SmartControl 3 User manual

Savant

Savant SmartControl 3 User manual

Savant WIF 104 Series User manual

Savant

Savant WIF 104 Series User manual

Savant SmartControl 12 User manual

Savant

Savant SmartControl 12 User manual

Savant Super Pro Host v2 SVR-7100S Quick reference guide

Savant

Savant Super Pro Host v2 SVR-7100S Quick reference guide

Savant S2 User manual

Savant

Savant S2 User manual

Savant HST-4001 User manual

Savant

Savant HST-4001 User manual

Savant SmartMediaPro 6 Quick reference guide

Savant

Savant SmartMediaPro 6 Quick reference guide

Savant SmartControl 2 Quick reference guide

Savant

Savant SmartControl 2 Quick reference guide

Savant LCB-DMX1 Quick reference guide

Savant

Savant LCB-DMX1 Quick reference guide

Savant SmartControl 3 Quick reference guide

Savant

Savant SmartControl 3 Quick reference guide

Savant SmartControl 3 User manual

Savant

Savant SmartControl 3 User manual

Savant SmartControl RS232 User manual

Savant

Savant SmartControl RS232 User manual

Savant SmartControl SSC-W002G User manual

Savant

Savant SmartControl SSC-W002G User manual

Savant SmartControl 12 User manual

Savant

Savant SmartControl 12 User manual

Savant Pro Host User manual

Savant

Savant Pro Host User manual

Popular Controllers manuals by other brands

Sunricher SR-ZV9003T3-RGBW-US Installation

Sunricher

Sunricher SR-ZV9003T3-RGBW-US Installation

Ksenia intro Installation and configuration manual

Ksenia

Ksenia intro Installation and configuration manual

Inovance CAN200 Series manual

Inovance

Inovance CAN200 Series manual

Gauzy LC6 FLEX Controller Installation and operation guide

Gauzy

Gauzy LC6 FLEX Controller Installation and operation guide

Viking SLP-1 Technical practice

Viking

Viking SLP-1 Technical practice

CKD KBX-30E-U Series instruction manual

CKD

CKD KBX-30E-U Series instruction manual

Sharp Energy Sun Flux User manual & installation guide

Sharp Energy

Sharp Energy Sun Flux User manual & installation guide

Yamaha RCX40 user manual

Yamaha

Yamaha RCX40 user manual

AB Quality PowerFlex 400 Frames D-H Service bulletin

AB Quality

AB Quality PowerFlex 400 Frames D-H Service bulletin

Yamaha MJC8 owner's manual

Yamaha

Yamaha MJC8 owner's manual

AL-KO ATC operating instructions

AL-KO

AL-KO ATC operating instructions

GameSir T3S user manual

GameSir

GameSir T3S user manual

Kostal inveor operating manual

Kostal

Kostal inveor operating manual

Emerson Yarway 20-55 Operating and safety instructions

Emerson

Emerson Yarway 20-55 Operating and safety instructions

CoCo ACM-LV24 Quick installation guide

CoCo

CoCo ACM-LV24 Quick installation guide

Brooks SLA5810/20 Installation and operation manual

Brooks

Brooks SLA5810/20 Installation and operation manual

SIGMA TEK SR 011 Technical manual

SIGMA TEK

SIGMA TEK SR 011 Technical manual

Aprilaire 76 installation instructions

Aprilaire

Aprilaire 76 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Box Contents
(1) SmartControl 25 (SSC-P025-11)
(1) Installation Kit: (075-0141-xx)
(2) 9-pin Screw Down Plug-in Connectors (028-9353-xx)
(2) 6-pin Screw Down Plug-in Connectors (028-9352-xx)
(1) 12V DC 1.25A Power Supply (025-0163-xx)
(1) 6 ft Power Cord (014-0035-xx)
(1) Quick Reference Guide (this document)
Specifications
Environmental
Environmental
Temperature
32° to 104° F (0° to 40° C)
Humidity
10% to 80% RH (non-condensing)
Cooling
3 cubic feet per minute (CFM)
recommended
Maximum BTU
51 BTU/hour
Dimensions and Weight
Dimensions and Weight
Height
1.52 in (3.86 cm)
Width
7.99 in (20.29 cm)
Depth
7.60 in (19.30 cm)
Weight
6 lb (2.72 kg)
Rack Space
1U
Power
Power
Power over Ethernet
(PoE)
IEEE 802.3af
Power Supply
(When not using PoE)
12V DC 1.25A
120-240V AC 50/60 Hz
Maximum Power
15 Watts
Compliance
Compliance
Safety and Emissions
FCC Part 15 | CE Mark | C -Tick
RoHS
Compliant
Minimum Supported Release
Minimum Supported Release
Savant OS
da Vinci 4.3.3
Front Panel
Power LED
Green: SSC-P025 has adequate power and is
operating normally.
Off: SSC-P025 is not receiving power.
Status LED
Green: Controller is operating normally.
Green Flashing: Controller has a DHCP or static IP
Address. Connecting to host.
Off: Unit is rebooting
Red: Firmware update has failed and unit will be
rebooted.
Red Flashing: No IP Address/Connecting to
Network.
Amber: Firmware update in process.
Amber Flashing: Controller has a link-local IP
Address and is connecting to the host. This
applies to controllers that are not connected to
an active router and may be connected directly to
a host.
Hardware Failure
Status LED indication will be interrupted every 3
seconds with a solid Red indication. For example,
if the LED is flashing Green when a hardware
failure occurs, the LED will flash Green, solid Red,
etc., in 3 second intervals.
RS-232 LED
Green: RS-232/422/485 serial port activity.
Off: No RS-232/422/485 serial port activity.
GPIO LED
Green: GPIO port activity.
Off: No GPIO port activity.
Link LED
Green: Ethernet port activity.
Off: No Ethernet port activity.
IR LED
Green: IR port signal activity.
Off: No IR port activity.
Relay LED
Green: Relay port activity.
Off: No Relay port activity.
SSC-P025-11 | 009-1259-02 | 151023
SSC-P025-11 | 009-1259-02 | 151023
45 Perseverance Way, Hyannis, MA 02601
Copyright © 2015 Savant Systems, LLC
1
of
4
savant.com | 508.683.2500
SmartControl 25 Controller
Quick Reference Guide
For Product Info
Rear Panel
Reset Button
Press and hold for 5 seconds while powered
On to clear network settings. Status LED will
blink rapidly when reset is complete.
PoE/Ethernet
8-pin RJ-45 female.
10/100 Base-T auto-negotiating port with
Link/Activity LEDs:
See items C and D for LED functionality.
Supports Power over Ethernet using PoE
IEEE 802.3af
Link LED
Off: Ethernet link is not established.
Green: Ethernet link is established.
Green Blinking: Ethernet activity is occurring.
Data Rate
LED
Off: 10 Mbps data rate
Green: 100 Mbps data rate
RS-232/
RS-422/
RS-485
8-pin RJ-45 female.
Used to transmit and receive serial binary
data to and from serial controllable devices.
Ports 1-4 RS-232 /RS-422
CTS/RTS handshaking.
Ports 5-8 RS-232/RS-422/RS-485
CTS/RTS handshaking.
CTS/RTS Handshaking availability based on
component profile.
See RS-232/422/485 Wiring for pinouts.
IR
6-pin Screw Down Plug-in Connector.
Used to send IR signals to control devices
with an IR input or IR receiver via an IR
flasher (5V tolerant only). See IR Wiring for
important precautions regarding IR
functionality before making any connections.
Relay
9-pin Screw Down Plug-in Connector.
See Relay Wiring for pinouts.
Normally Open (NO) Normally Closed (NC)
to control devices requiring basic on/off
operation. DC Voltage Max: 30V DC 1A.
GPIO
9-pin Screw Down Plug-in Connector.
See GPIO Wiring for pinouts.
GPIO Input: When configured as an input,
the processor will look for a low (<0.8V DC)
or a high (>2.4V DC ) state.
Minimum 0V DC / Maximum 12V DC
GPIO Output: When configured as an
output, the port provides a binary output of
0-12V DC 150mA max.
Ground Connector - used to connect to a
suitable ground reference when using Power
over Ethernet (PoE).
Power Input
12V DC 1.25A - Connect to power supply
when not using PoE.
Wiring and Connections
RS-232/422/485 Wiring
When making connections, label the cables with the source and
destination. This will make modifications and troubleshooting easier.
RS-232 Pinouts
Note: CTS/RTS Handshaking availability based on component profile.
RS-422/RS-485 Pinouts
RJ-45 to DB9 Adapters
Savant offers RJ-45 to DB9 adapters in a variety of configurations
that can be used for RS-232/422/485 control.
Refer to the RS-232 Conversion to DB9 and RS-422/485 Pinout
Application Note located on the Savant Customer Community for
more information on RJ-45 to DB9 adapters.
IMPORTANT!
If you are using RJ-45 to DB9 adapters not supplied by Savant:
•Ensure that any wires required for communication/control are
terminated within the adapter.
•Ensure that all wires NOT required for communication/control
are NOT terminated in the connector.
•Ensure that the unused wires in the connector are cut to prevent
them shorting out, as they are still terminated in the RJ-45
connector on the controller side.
SSC-P025-11 | 009-1259-02 | 151023
SSC-P025-11 | 009-1259-02 | 151023
45 Perseverance Way, Hyannis, MA 02601
Copyright © 2015 Savant Systems, LLC
2
of
4
savant.com | 508.683.2500
IR Wiring
IR connections are made using 6-pin Screw Down Plug-in
Connectors supplied with controller. The wire slips into the hole and
locks with the screw located at the top of the connector.
IMPORTANT! IR Wiring Precautions
•Ensure that all IR emitters are within 15 feet (4.6 meters) from
the controllers location.
•Use of 3rd party flashing IR emitters with Talk Back is not
recommended. These types of emitters can draw voltage away
from the IR signal that can degrade IR performance.
IR Pinout
Note:
While not shown in the diagram above, IR connections 4 to 6 follow
the same wiring as 1 to 3.
GPIO Wiring
General Purpose Input/Outputs (GPIO) are binary I/O ports used on
Savant controllers to trigger an action within the system. Events
can control a device, such as turning on an amplifier (output) or
detecting a state change for a device (input) to perform a workflow.
Pins 2-8 are used for input or output depending on configuration.
GPIO Pinout
Relay Wiring
Relay ports are used when a device is controlled via a normally
open (NO) or normally closed (NC) relay.
Relay Pinout
Installation
The SSC-P025 can be placed on a 1U rack shelf, wall mounted using
the side-mounting brackets SMB-1000-xx or rack mounted using
the rack mount brackets RMB-0025-xx.
Wall Mounting (SMB-1000-xx)
Use the supplied screws to install the brackets to the SSC-P025 as
shown.
Rack Mounting Bracket (RMB-0025-xx)
Use the supplied screws to install the faceplate to the SSC-P025 as
shown.
SSC-P025-11 | 009-1259-02 | 151023
SSC-P025-11 | 009-1259-02 | 151023
45 Perseverance Way, Hyannis, MA 02601
Copyright © 2015 Savant Systems, LLC
3
of
4
savant.com | 508.683.2500
Network Requirements
Savant requires the use of business class/commercial grade network
equipment throughout the network to ensure the reliability of
communication between devices. These higher quality components
also allow for more accurate troubleshooting when needed.
Device Network Connections
Connect all Savant devices to the same local area network (LAN) or
subnet as the host. Savant recommends not implementing any type
of traffic or packet shaping in your network topology for the Savant
devices as this may interfere with performance.
Managing IP Addresses
To ensure that the IP Address will not change due to a power
outage, a static IP Address or DHCP reservation should be
configured. Savant recommends using DHCP reservation within the
router. By using this method, static IP Addresses for all devices can
be managed from a single UI avoiding the need to access devices
individually.
Setting a Static IP Address
Refer to the Retrieving and Setting IP Addresses for Savant
Devices - Application Note located on the Savant Customer
Community.
Setting DHCP Reservation
Setting DHCP reservation varies from router to router. Refer to the
documentation for the router to configure DHCP reservation.
Network Changes
Savant recommends performing one of the following steps to
refresh the IP connection after connecting to a new network,
changing routers, or if the IP Address range is changed in the
current router. This will reset any IP connection and ensure that the
host is communicating with the network correctly.
•Cycle Power
1. Disconnect the controller from the DC power source
2. Wait 15 seconds and then reconnect.
•Hot Plug the Ethernet (LAN) Connection
1. Disconnect the Ethernet (LAN) connection from the
controller.
2. Wait 15 seconds and then reconnect.
Additional Information
Refer to the following documents located on the Savant Customer
Community for additional information.
•SmartControl 25 (SSC-0025/SSC-P025) Deployment Guide
SSC-P025-11 | 009-1259-02 | 151023
SSC-P025-11 | 009-1259-02 | 151023
45 Perseverance Way, Hyannis, MA 02601
Copyright © 2015 Savant Systems, LLC
4
of
4
savant.com | 508.683.2500