manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Saxby Lighting
  6. •
  7. Outdoor Light
  8. •
  9. Saxby Lighting Inova PIR Wall Manual

Saxby Lighting Inova PIR Wall Manual

Instruction leaflet
Inova PIR Wall
49945,49946
For your safety, always switch off the power supply before changing lightbulbs, or cleaning.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist.
Check with your Local Authority or retailer for recycling advice.
Recycling advice
Safety information
Do not use solvents or abrasive cleaners as these could
damage the finish.
In normal circumstances, stainless steel is very resistant to
corrosion. It does however require maintenance to preserve
the high quality appearance. Wash the product with warm
soapy water, removing all surface deposits. Rinse with clear
water and with a soft cloth, wipe dry.
In some cases, surface corrosion may arise after installation.
This is normally caused by tiny iron particles left behind
after the brushing process when finishing.
Wash and dry as detailed above. Then with a soft cloth
soaked with a protective oil, wipe all over.
However if the product is subject to extreme environmental
conditions such as marine locations, industrial pollution
and acid rain these maintenance procedures should be
carried out around four times a year. For severe corrosion,
non-abrasive cream cleaners or proprietary stainless steel
cleaners should be used to remove the corrosion. Wash and
dry as detailed above. Then with a soft cloth soaked with a
protective oil, wipe all over.
Shade - Remove and wash in warm water or just use a
damp cloth. Do not use abrasive materials as these will
damage the finish.
Do not clean the units with a pressure washer.
This bulb is protected by a shade. This part must be replaced immediately should the shade become
cracked or damaged. This fitting must not be used without the shade in place.
Replace Cracked Shade
When changing a bulb, always switch off at the mains and
allow the bulb to cool before handling. Dispose of used
bulbs carefully.
Do not exceed the wattage stated or use a different shape
bulb from that indicated on the fitting.
To access the bulb, remove the screws on top of the shade,
and lift off the top. Set aside.
Relocate the shade top over the screws and secure in place
with the screws.
Fitting/replacing bulb
Care and Cleaning
Detection range can be adjusted
by turning 'Sens' screw
Adjustable 1 - 8 metres
Duration the bulb stays on is
adjustable by turning 'Time' screw
Base of product
1.8 Meter s
4M2M 8M
Sens
Time
MAX. 60W E27 GLS
N.B: Unlike many PIR fittings these do
not come on once fist commissioned.
They will only activate for the first time
once the ambient light level drops below
10 Lux
V2 27/03/2020
BH17 7BY
Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory
operation of this product. Please retain these instructions for future reference.
Warning
This is a Class 1 product and must be earthed.
Please read these instructions carefully before
commencing any work.
This unit must be fitted by a competent and qualified
electrician.
Install in accordance with IEE Wiring regulations and
current Building Regulations.
To prevent electrocution switch off at mains supply
before installing or maintaining this fitting. Ensure other
persons cannot restore the electrical supply without
your knowledge. If you are in any doubt, please consult a
qualified electrician.
TThis light fitting should be connected to a circuit with a
30mA RCD fitted.
If replacing an existing fitting, make a careful note of the
connections.
Always use the correct type and wattage bulb. Never
exceed the wattage stated.
When changing a bulb, always switch off at the mains and
allow the old bulb to cool down before handling. Dispose
of used bulbs carefully and responsibly.
Waste electrical products should not be disposed of with
household waste. Please recycle where facilities exist.
Check with your local authority or retailer for recycling
advice.
This product is rated at IP44.
This product is not suitable for location in or near a
marine environment.
The entire unit gets hot whilst on for a period of time.
Unlike many PIR fittings these do not come on once fist
commissioned. They will only activate for the first time
once the ambient light level drops below 10 Lux
Specification
Voltage: 240V 50Hz a.c.
Lamp: 1 x Max 60W E27 (ES)
IP rating: 44
Layout
Installation
conduit or plastic trunking.
cable (not supplied) which is an outdoor grade, rubber
sheathed cable. The mains supply cable must have a
minimum cross sectional area of 1.0mm
of moisture and is IP44 rated.
Existing fittings must be completely removed before
installation of a new product. Before removing the existing
fitting, carefully note the position of each set of wires.
dome nuts (C) and washers (D). Carefully pierce a
small hole in the rubber gasket in the centre of the
mounting box to allow the cable to pass through.
hole is at the base of the mounting box.
and plugs supplied (B). Ensure the wall is capable of
holding the weight of the product. Take care to avoid
damaging any concealed wiring and pipes. The correct
fixings should be used for brick or cavity walls.
fitting.
You have correctly identified
the wires
The connections are tight
No loose strands have been
left out of the connection block.
SUPPLY
NEUTRAL
LIGHT FITTING
BLUE (N)
EARTH (GREEN/YELLOW) GREEN/YELLOW
BROWN (L)
SWITCHED LIVE
Having correctly identified the wiring from your existing light
fitting, pull the wire through the hole and connect to the
connection block inside the product in the following way:
Wiring
Check that...
Commissioning
the IP rating of the product.
washers (D) and dome nuts (C), tighten dome nuts to
secure.
is now ready for use.
PIR Adjustment
1.8m above the ground.
distance to be altered to suit the location. The detection
angle is set at 110 degrees. The duration that the
lamp stays on can also be altered from 5 seconds - 5
minutes. Use a small screwdriver to adjust the ‘TIME’ and
‘SENS’ screws. When adjusting the sensitivity (detection
distance) in daylight it will be necessary to cover the
sensor to simulate night time.
A
B
C
D
Gasket
Drain hole Front view of
mounting box

This manual suits for next models

2

Other Saxby Lighting Outdoor Light manuals

Saxby Lighting EL-40062 Manual

Saxby Lighting

Saxby Lighting EL-40062 Manual

Saxby Lighting 75434 User manual

Saxby Lighting

Saxby Lighting 75434 User manual

Saxby Lighting EL-40094 Manual

Saxby Lighting

Saxby Lighting EL-40094 Manual

Saxby Lighting ALBA User manual

Saxby Lighting

Saxby Lighting ALBA User manual

Saxby Lighting Louvre Outdoor Wall Fitting User manual

Saxby Lighting

Saxby Lighting Louvre Outdoor Wall Fitting User manual

Saxby Lighting BLISS 13799 User manual

Saxby Lighting

Saxby Lighting BLISS 13799 User manual

Saxby Lighting Picco 95205 User manual

Saxby Lighting

Saxby Lighting Picco 95205 User manual

Saxby Lighting Seina 52104 Manual

Saxby Lighting

Saxby Lighting Seina 52104 Manual

Saxby Lighting POLGU10 User manual

Saxby Lighting

Saxby Lighting POLGU10 User manual

Saxby Lighting Severus EL-40105 Manual

Saxby Lighting

Saxby Lighting Severus EL-40105 Manual

Saxby Lighting Ware Outdoor Wall Manual

Saxby Lighting

Saxby Lighting Ware Outdoor Wall Manual

Saxby Lighting Solaris 76925 Manual

Saxby Lighting

Saxby Lighting Solaris 76925 Manual

Saxby Lighting Atlantis Post Manual

Saxby Lighting

Saxby Lighting Atlantis Post Manual

Saxby Lighting Triton Spike User manual

Saxby Lighting

Saxby Lighting Triton Spike User manual

Saxby Lighting Hoxton 79195 User manual

Saxby Lighting

Saxby Lighting Hoxton 79195 User manual

Saxby Lighting Atlantis Post Manual

Saxby Lighting

Saxby Lighting Atlantis Post Manual

Saxby Lighting HOXTON RECESSED User manual

Saxby Lighting

Saxby Lighting HOXTON RECESSED User manual

Saxby Lighting Palin Spike Manual

Saxby Lighting

Saxby Lighting Palin Spike Manual

Saxby Lighting Bianco LED CCT PIR User manual

Saxby Lighting

Saxby Lighting Bianco LED CCT PIR User manual

Saxby Lighting 73716 User manual

Saxby Lighting

Saxby Lighting 73716 User manual

Saxby Lighting Ware Outdoor Wall Manual

Saxby Lighting

Saxby Lighting Ware Outdoor Wall Manual

Saxby Lighting 13889 User manual

Saxby Lighting

Saxby Lighting 13889 User manual

Saxby Lighting Pati User manual

Saxby Lighting

Saxby Lighting Pati User manual

Saxby Lighting 1818PIR Manual

Saxby Lighting

Saxby Lighting 1818PIR Manual

Popular Outdoor Light manuals by other brands

Kichler Lighting HELEN 37536 instructions

Kichler Lighting

Kichler Lighting HELEN 37536 instructions

Thorn OXANE L installation instructions

Thorn

Thorn OXANE L installation instructions

esotec Solar Globe Light multicolor 20 operating instructions

esotec

esotec Solar Globe Light multicolor 20 operating instructions

mitzi HL200201 ELLIS Assembly and mounting instructions

mitzi

mitzi HL200201 ELLIS Assembly and mounting instructions

HEPER TILA S AFX 3 Module Installation & maintenance instructions

HEPER

HEPER TILA S AFX 3 Module Installation & maintenance instructions

Designplan TRON 180 installation instructions

Designplan

Designplan TRON 180 installation instructions

Sealey LED37 instructions

Sealey

Sealey LED37 instructions

nordlux VEJERS Mounting instruction

nordlux

nordlux VEJERS Mounting instruction

SImx ELITE LED LHTC637 installation instructions

SImx

SImx ELITE LED LHTC637 installation instructions

GEV CAROLINE 10833 manual

GEV

GEV CAROLINE 10833 manual

WE-EF PFL540 LED Installation and maintenance instructions

WE-EF

WE-EF PFL540 LED Installation and maintenance instructions

HEPER DOGO Side LW6048.585-US Installation & maintenance instructions

HEPER

HEPER DOGO Side LW6048.585-US Installation & maintenance instructions

BEGA 84 253 Installation and technical information

BEGA

BEGA 84 253 Installation and technical information

HEPER LW8034.003-US Installation & maintenance instructions

HEPER

HEPER LW8034.003-US Installation & maintenance instructions

HEPER MINIMO Installation & maintenance instructions

HEPER

HEPER MINIMO Installation & maintenance instructions

LIGMAN BAMBOO 3 installation manual

LIGMAN

LIGMAN BAMBOO 3 installation manual

Maretti TUBE CUBE WALL 14.4998.04 quick start guide

Maretti

Maretti TUBE CUBE WALL 14.4998.04 quick start guide

Maxim Lighting Carriage House VX 40428WGOB installation instructions

Maxim Lighting

Maxim Lighting Carriage House VX 40428WGOB installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.