Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory
operation of this product. Please retain these instructions for future reference.
Warning
This is a Class 1 product and must be earthed.
Please read these instructions carefully before
commencing any work.
This unit must be fitted by a competent and qualified
electrician.
Install in accordance with IEE Wiring regulations and
current Building Regulations.
To prevent electrocution switch off at mains supply
before installing or maintaining this fitting. Ensure other
persons cannot restore the electrical supply without
your knowledge. If you are in any doubt, please consult a
qualified electrician.
TThis light fitting should be connected to a circuit with a
30mA RCD fitted.
If replacing an existing fitting, make a careful note of the
connections.
Always use the correct type and wattage bulb. Never
exceed the wattage stated.
When changing a bulb, always switch off at the mains and
allow the old bulb to cool down before handling. Dispose
of used bulbs carefully and responsibly.
Waste electrical products should not be disposed of with
household waste. Please recycle where facilities exist.
Check with your local authority or retailer for recycling
advice.
This product is rated at IP44.
This product is not suitable for location in or near a
marine environment.
The entire unit gets hot whilst on for a period of time.
Unlike many PIR fittings these do not come on once fist
commissioned. They will only activate for the first time
once the ambient light level drops below 10 Lux
Specification
Voltage: 240V 50Hz a.c.
Lamp: 1 x Max 60W E27 (ES)
IP rating: 44
Layout
Installation
conduit or plastic trunking.
cable (not supplied) which is an outdoor grade, rubber
sheathed cable. The mains supply cable must have a
minimum cross sectional area of 1.0mm
of moisture and is IP44 rated.
Existing fittings must be completely removed before
installation of a new product. Before removing the existing
fitting, carefully note the position of each set of wires.
dome nuts (C) and washers (D). Carefully pierce a
small hole in the rubber gasket in the centre of the
mounting box to allow the cable to pass through.
hole is at the base of the mounting box.
and plugs supplied (B). Ensure the wall is capable of
holding the weight of the product. Take care to avoid
damaging any concealed wiring and pipes. The correct
fixings should be used for brick or cavity walls.
fitting.
You have correctly identified
the wires
The connections are tight
No loose strands have been
left out of the connection block.
SUPPLY
NEUTRAL
LIGHT FITTING
BLUE (N)
EARTH (GREEN/YELLOW) GREEN/YELLOW
BROWN (L)
SWITCHED LIVE
Having correctly identified the wiring from your existing light
fitting, pull the wire through the hole and connect to the
connection block inside the product in the following way:
Wiring
Check that...
Commissioning
the IP rating of the product.
washers (D) and dome nuts (C), tighten dome nuts to
secure.
is now ready for use.
PIR Adjustment
1.8m above the ground.
distance to be altered to suit the location. The detection
angle is set at 110 degrees. The duration that the
lamp stays on can also be altered from 5 seconds - 5
minutes. Use a small screwdriver to adjust the ‘TIME’ and
‘SENS’ screws. When adjusting the sensitivity (detection
distance) in daylight it will be necessary to cover the
sensor to simulate night time.
A
B
C
D
Gasket
Drain hole Front view of
mounting box