Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and
satisfactory operation of this product. Please retain these instructions for future reference.
Warning
This is a Class 1 product and must be earthed.
Please read these instructions carefully before
commencing any work.
This unit must be fitted by a competent and qualified
electrician.
Install in accordance with IEE Wiring regulations and
currentBuildingRegulations.
To prevent electrocution switch off at mains supply
before installing or maintaining this fitting. Ensure
other persons cannot restore the electrical supply
without your knowledge. If you are in any doubt,
please consult a qualified electrician.
This light fitting should be connected to a fused circuit.
If replacing an existing fitting, make a careful note of
the connections.
Always use the correct type and wattage bulb. Never
exceed the wattage stated.
When changing a bulb, always switch off at the mains
and allow the old bulb to cool down before handling.
Dispose of used bulbs carefully and responsibly.
Waste electrical products should not be disposed of
with household waste. Please recycle where facilities
exist. Check with your local authority or retailer for
recycling advice.
This product is rated at IP44.
The entire unit gets hot whilst on for a period of time.
Specification
Voltage: 240V 50Hz a.c.
Lamp: 1 x Max. 23W E27 PL
IP rating: 44
Layout
Installation
• Planthedesiredlayoutofthisfittingcarefully,
ensuring the cables will reach the distance between
the junction box and the light fitting
• Avoidlocatinganycablesinpositionsthatwould
cause a hazard. Position cables and junction boxes
(not supplied) away from areas where they may be
at risk from being cut, trapped or damaged
• Cablesinwallsmustbeprotectedusingsuitable
conduit or plastic trunking.
• WerecommendthatyouuseH05RN-Fspecification
cable (not supplied) which is an outdoor grade,
rubber sheathed cable. The mains supply cable must
have a minimum cross sectional area of 1.0mm²
• Thesefittingmustbemountedoneitheraconcrete
surface or a paving slab that has been concreted in
position.
Existing fittings must be completely removed before
installation of a new product. Before removing the
existing fitting, carefully note the position of each set
of wires.
• Usingthebaseplateasatemplate,markthefixing
holes onto the mounting surface.
• Drillholestothenecessarysizeanddepth-taking
care not to damage any concealed pipes or wiring
below the mounting surface.
• Thisproductcomescompletewithscrewand
rawl plugs (A & B) which are suitable for use on
most surfaces, however alternative fixings may be
required.
• Pushtherawlplugsintothemountingholes.
Wiring
Having correctly identified the wiring from your existing
light fitting, pull the wire through the hole and connect
to the connection block inside the product in the
following way:
• Pullterminalblock(C)frominsideoftube.
• Unscrewthe4screwswhichattachtheblackbox
to the spacing strip. Open the black box and pull out
the terminal block.
• ConnectLiveinputwiretobrownwireonproduct
(or terminal on terminal block marked ‘L’).
• ConnectNeutralinputwiretobluewireonproduct
(or terminal on terminal block marked ‘N’).
• ConnectInputEarthwire(Green/yellow)toEarth
wire on fitting,
• Checkthatyouhavecorrectlyidentifiedthesupply
wires, the connections are tight and that no loose
strands have been left out of the connection block.
• Pushterminalblockbackintotheblackbox.
Re-attachtheblackboxtothemountingbracket.