Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory
operation of this product. Please retain these instructions for future reference.
Warning
Specification
Voltage: 240V 50Hz a.c.
Lamp: 0.6W LED Module (SMD 3014) Warm White - 25lm
IP rating: 65
Layout
Installation
Wiring
Existing fittings must be completely removed before
installation of a new product. Before removing the existing
fitting, carefully note the position of each set of wires.
• Determinethepositionofyourlightfittingtakinginto
account the entry position of the cable and make sure
there is sufficient cable coming out of the wall to
connect to the terminal block. Ensure that the mounting
surface is solid, preferably a brick or block wall and
ensure that there are no other cables or pipes beneath
the surface.
•Diagram A. Gently prise off the cover plate to reveal the
6 retaining screws on the sides of the unit.
•Diagram B.Removethese4xscrewsandretainfor
re-use.
•Diagram C. Bring the mains cable through the rubber
grommet in the wall plate and then use the wall plate as
a template and mark the fixings holes. Make sure the wall
plate is correctly aligned so that the top of it is horizontal.
Use appropriate fixings to secure the back plate to the
wall.
•Wire as detailed below.
• Planthedesiredlayoutofthisfittingcarefully,ensuring
the cables will reach the distance between the junction
box and the light fitting.
• Avoidlocatinganycablesinpositionsthatwouldcause
a hazard. Position cables and outdoor rated junction
boxes (not supplied) away from areas where they may
be at risk from being cut, trapped or damaged.
• WerecommendthatyouuseH05RN-Fspecification
cable which is an outdoor grade, rubber sheathed cable.
The mains supply cable must have a minimum cross
sectional area of 1.0mm²
• Cablesmustbeprotectedusingsuitableconduitor
plastic trunking.
This light fitting is Double Insulated and does
not require connection to an Earth circuit.
Please read these instructions carefully before
commencing any work.
This unit must be fitted by a competent and qualified
electrician.
Install in accordance with IEE Wiring regulations and
currentBuildingRegulations.
To prevent electrocution switch off at mains supply
before installing or maintaining this fitting. Ensure other
persons cannot restore the electrical supply without your
knowledge. If you are in any doubt, please consult a
qualified electrician.
This light fitting should be connected to a fused circuit.
If replacing an existing fitting, make a careful note of the
connections.
This system contains non-replaceable parts and cannot be
serviced. If damage occurs the part should be scrapped.
Waste electrical products should not be disposed of with
household waste. Please recycle where facilities exist.
Check with your local authority or retailer for recycling
advice.
This product is rated at IP65.
This product is not suitable for location in or near a
marine environment.
This product is not suitable for dimming.
Having correctly identified the wiring from your light fitting,
connect to the approved outdoor rated external terminal
block in the following way:
Check that...
• Youhavecorrectlyidentifiedthewires
• The connections are tight
• Noloosestrandshavebeenleftoutoftheconnection
block.
• Resealtheapprovedoutdoorratedexternalterminal
block.
e
Grommet
Securing
screws
Incoming
supply
Wall plate
Led housing unit
Lens housing
Diagram A.
Diagram B.
Diagram C
SUPPLY
NEUTRAL
LIGHT FITTING
BLUE(N)
BROWN(L)
SWITCHED LIVE