SEH utnserver Pro User manual

USB Deviceserver
utnserver Pro
Quick Installation Guide
MHAB-QI-utnPro
Version: 1.0 | 2020-10

Overview
This 'Quick Installation Guide' describes the hardware installation and initial
setup of the utnserver Pro.
Table of contents 1.
Do you need assistance? Contact us!
Customers from the United States of America and Canada please contact the
North American support.
Überblick
Dieser 'Quick Installation Guide' beschreibt die Hardware-Installation und
Inbetriebnahme des utnserver Pro.
Inhaltsverzeichnis 15.
Benötigen Sie Hilfe? Kontaktieren Sie uns!
Monday to Thursday
Friday 8:00 a.m. to 4:45 p.m. and
8:00 a.m. to 3:15 p.m. (CET)
+49 (0)521 94226-44
support@seh.de
www.seh-technology.com
Monday to Friday 9:00 a.m. to 5:00 p.m. (EST/EDT)
+1-610-943-3226
support@sehtechnology.com
www.seh-technology.com
Montag–Donnerstag
Freitag 8:00–16:45 Uhr
8:00–15:15Uhr
+49 (0)521 94226-44
support@seh.de
www.seh.de

Quick Installation Guide [en] 1
Contents
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Purpose .....................................................................................................................................2
Scope of Supply .....................................................................................................................2
Technical Data.........................................................................................................................3
LED Display..............................................................................................................................4
Type Plate.................................................................................................................................4
Safety Regulations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Hardware Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Software Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
SEH Product Manager..........................................................................................................7
SEH UTN Manager .................................................................................................................8
Getting Started: SEH UTN Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Starting the SEH UTN Manager ......................................................................................10
Finding the UTN Server and Assigning an IP Address............................................11
Adding the UTN Server to the Selection List.............................................................12
Connecting the USB Device to the Client...................................................................13
Configuring the UTN Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Regulatory Compliance Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Open Source Software License Disclaimer and License Texts . . . . . . . . . . . .32

2 [en] Quick Installation Guide
General Information
Purpose
The USB Deviceserver 'utnserver Pro’ makes non-network-ready USB devices
accessible via TCP/IP network.
For this purpose, the USB devices (e.g. hard disks, etc.) will be connected to the
USB ports of the utnserver Pro. Then the UTN (UTN = USB to Network)
functionality and the corresponding software tool 'SEH UTN Manager' establish
a virtual USB connection between USB device and client. The USB device can be
used as if it were connected locally.
Scope of Supply
Check the package content before getting started:
UTN server Deviceserver 'utnserver Pro'
Quick
Installation
Guide
The Quick Installation Guide provides a brief
description of the installation of the utnserver
Pro.
(This document)
Power pack External power pack

Quick Installation Guide [en] 3
Technical Data
Properties Values
Network connectorlogical:
physical: IEEE 802.3 (1000BaseT, 100BaseTX and 10BaseT)
1 × RJ-45 (STP, category 5 or better)
Device connection • 2 × USB 3.0 SuperSpeed (USB ports 1–2)
Current input • approx. 500 mA at 5 V direct current without load
• approx. 2500 mA at 5 V direct current with full
load on the USB ports
Power consumption • approx. 3 W without load
• approx. 14 W with full load on the USB ports
• approx. 26–123 kWh/year, depending on
utilization
Operating environment ambient temperature: 5–40 °C
relative humidity: 20–80 %
Dimensions width: 120 mm
height: 30 mm
depth: 84 mm
weight: 125 g (without power supply unit)
USB ports 1-2
with LED for the USB port
2
1
network connector
(RJ-45)
(at the rear side)
power supply
connector
(at the rear side)
status LED
(RGB)
activity LED
(yellow) link LED
(green)

4 [en] Quick Installation Guide
LED Display
The LEDs of the UTN server provide information about its status.
Type Plate
The type plate gives important product information, such as hardware and
certification information as well as the serial number. The serial number
contains the production date: nnn YYYY MM nnnnn.
This information helps you e.g. during maintenance and is needed for support
requests.
LED Action Color Description
Link and
Activity permanently off – There is no connection to the network.
Link permanently on green There is a connection to the network.
Activity blinks at
irregular
intervals
yellow Indicates the exchange of UTN
packets.
Status blinks 3 times
blinks 2 times
blinks 2 times
green
green
purple
Indicates the assignment of a Zeroconf
IP address.
Indicates the assignment of an IP
address that is not from the Zeroconf
range.
utnserver Pro operates with
elementary secure settings.
(HTTPs, no SNMPv1, restricted Control
Center access, encrypted USB
communication)
USB port
1–2 permanently off
permanently on
permanently on
–
green
orange
No USB device is connected to the
respective port.
A USB device is connected to the
respective port.
The connection to the respective port
and the attached USB device is
activated.
Important:
When the device starts up, the behavior of the LEDs
differs from this description.

Quick Installation Guide [en] 5
Safety Regulations
UTN servers are network devices for use in office environments. The utnserver
Pro is designed for the integration of USB device into TCP/IP networks.
• Read the documentation and make sure that your system meets the require-
ments listed therein.
• Avoid contact with humidity or liquids.
• The device must only be connected and operated if it is in perfect condition.
• Make sure that no-one steps on or stumbles over the cables.
• If the supplied power cord cannot be used in your country, acquire an appro-
priate power cord that suits national provisions. For more information, con-
sult your retailer.
• Do not connect a telephone cable to the RJ-45 connector. The RJ-45 connec-
tor may only be connected to SELV voltages. For the connection to the RJ-45
connector only STP cabling (category 5 or better) may be used. The shielding
must fit flushly to the connector.
• Do not open the housing. Unauthorized modifications to the device can af-
fect the product certification and are forbidden.
• The device must not be directly connected to outdoor lines.
• The device must only be operated using the power pack included in the
package.
• Only use a certified USB cable (< 3 m) listed at www.usb.org.
• Electrostatic discharges (ESD) may impair device performance.
• An interruption of the supply voltage may impair device performance or
cause malfunctions.
Important:
Before starting the installation and the initial setup
procedure as well during the operation of the UTN
server, note the following safety regulations. Their
purpose is to protect yourself and others from personal
injuries, and to avoid damage to the equipment.

6 [en] Quick Installation Guide
Hardware Installation
You can directly connect up to 2 USB devices to the utnserver Pro.
1. Connect the USB device to a USB port of the UTN server.
2. Repeat step 1 if you want to connect more than one USB device.
3. Connect the network cable (RJ-45) to the UTN server.
4. Connect the power cord to the UTN server.
The UTN server boots and then is ready for use.
Important:
USB device and UTN server can be connected via a USB
cable, if required.
Only use USB cables shorter than 3 meters.
USB devices
UTN
connection
clients with software tool
'SEH UTN Manager'
UTN deviceserver
USB 3.0
USB 3.0
network

Quick Installation Guide [en] 7
Software Installation
SEH Product Manager
The 'SEH Product Manager' is a software tool developed by SEH
Computertechnik GmbH for the administration and management of SEH
Computertechnik GmbH devices on the network.
The software is installed on all clients from which SEH Computertechnik GmbH
devices are to be administrated and managed on the network.
First, you have to download the installation file for the SEH Product Manager
from the website of SEH Computertechnik GmbH:
http://www.seh-technology.com/services/downloads/
download-deviceserver/utnserver-pro.html
System requirements:
– Windows 10, Windows Server 2012 or later
macOS 10.12.x or later
– The installation can only be carried out by users with administrative rights.
1. Start the SEH Product Manager installer.
2. Follow the installation routine.
The SEH Product Manager is installed on your client.
You can recognize the SEH Product Manager by its icon: . The program is
started with the usual methods of your operating system.
The program automatically searches for SEH Computertechnik devices on the
network after starting. For more information see the 'SEH Product
Manager Online Help'

8 [en] Quick Installation Guide
SEH UTN Manager
The 'SEH UTN Manager' is a software tool developed by SEH Computertechnik
GmbH. The SEH UTN Manager is used to establish and manage connections to
the USB devices connected to UTN servers.
The SEH UTN Manager is available in two versions:
• complete version:
has a graphical user interface and offers additional features
• minimal version:
command-line interface only
A detailed description can be found in the USB Deviceserver User Manual.
The SEH UTN Manager has to be installed on all clients that are intended to
access a USB device via the network. Different installation files are available,
depending on the operating system.
First, you have to download the installation file for the SEH UTN Manager from
the website of SEH Computertechnik GmbH:
http://www.seh-technology.com/services/downloads/
download-deviceserver/utnserver-pro.html
System requirements:
– Windows 10, Windows Server 2012 or later
OS X respectively macOS 10.9 or later
– The installation can only be carried out by users with administrative rights.
1. Start the installation file.
2. Install the complete version of the SEH UTN Manager (including graphical
user interface). To do so, follow the installation routine.
The SEH UTN Manager is installed on your client.
Important:
The SEH UTN Manager is also available for selected
Linux systems.
All information necessary for installing and using the
SEH UTN Manager in Linux environments can be found
in the USB Deviceserver User Manual Linux. The
documentation is available via the link given above.
Table of contents
Languages:
Other SEH Server manuals

SEH
SEH ProMAX User manual

SEH
SEH INU-100 Manual

SEH
SEH myUTN utnserver Pro User manual

SEH
SEH myUTN-80 User manual

SEH
SEH INU-100 User manual

SEH
SEH myUTN-52 User manual

SEH
SEH Dongleserver myUTN-800 User manual

SEH
SEH Dongleserver myUTN-800 User manual

SEH
SEH myUTN-50a User manual

SEH
SEH myUTN-120 User manual































