Sharp FU-S51A User manual

ENGLISH
FU-S51E
FU-S51A
AIR PURIFIER
OPERATION MANUAL
R
Free Standing
*Plasmacluster is a trademark of
Sharp Corporation.
*Plasmacluster是聲寶公司的商標

Please read before operating your new Air Purifier
The air purifier draws in room air from its air intake, lets the air pass through a
Active Carbon Filter (deodorization filter) and a HEPA Filter (dust collection
filter) inside of the unit, then discharges the air from its air outlet. The air
purifier unit repeats this process by moving its internal fan.
As air passes through, a new HEPA Filter can remove 99.97% of dust parti-
cles, of as small as 0.3 microns. The Active Carbon Filter gradually absorbs
odour elements as they repeatedly pass through the filter. (Odour elements
are absorbed by HEPA Filter as well.)
Some odour ingredients absorbed by the filters may become separated and
may be discharged through the air outlet and result in additional odour. De-
pending on the usage environment, especially when the product is used in a
condition significantly more severe than household use, this odour may be-
come strong in a shorter period than expected.
If the odour persists, then the filters are fully expended and it is necessary to
purchase the optional replacement filter.
NOTE
•The air purifier is designed to remove air-suspended dust and odour, but not harmful gases (for
example, carbon monoxide contained in cigarette smoke). If the odour sources still exist, it cannot
completely remove the odour. (for example, odours from construction materials and pet odours).
• It is suggested to open the window a bit when you are smoking in order to facilitate ventilation.

ENGLISH
FEATURES
ION SHOWER
E-1
ENGLISH
Thank you for purchasing the SHARP Air Puri-
fier. Please read this manual carefully for the cor-
rect usage information. Before using this prod-
uct, be sure to read the section: “Important Safety
Instructions.”
After reading this manual, retain it in a conven-
ient location for future reference.
IMPORTANT SAFETY INSTRUCTIONS ....
E-2
•WARNING ....................................................E-2
•CAUTIONS CONCERNING OPERATION ...E-3
•INSTALLATION GUIDELINES ..................... E-3
•FILTER GUIDELINES ..................................E-3
PART NAMES .......................................... E-4
•MAIN UNIT DISPLAY ...................................E-4
•ILLUSTRATIVE DIAGRAM .......................... E-4
• BACK ...........................................................E-5
• INCLUDED ...................................................E-5
PREPARATION........................................ E-6
•FILTER INSTALLATION ...............................E-6
OPERATION ............................................ E-8
•MAIN UNIT OPERATION ............................. E-8
CARE AND MAINTENANCE ................. E-10
•MAIN UNIT ................................................ E-10
• FILTER ...................................................... E-10
• SENSORS ................................................ E-10
•
WASHABLE ACTIVE CARBON FILTER CARE ....
E-11
•FILTER REPLACEMENT
GUIDELINES ............................................ E-12
SPECIFICATIONS ................................. E-12
TROUBLESHOOTING........................... E-13
CONTENTS
New ION SHOWER Operation Mode
releases the concentrated Plasmacluster
Ions, and effectively removes the pollen
and mold, and also controls the activity of
airborne virus, mold, and allergen.
Plasmacluster Ion Control
Your new air purifier will control the ratio
of negative ions and positive ions de-
pending on the condition of the room.
•Clean Mode
Approximately the same numbers of
positive and negative ions are dis-
charged.
•AUTO Plasmacluster Ion
Mode
The unit will switch between Clean Mode
and Ion Control Mode* automatically
depending on the amount of impurities
in the air detected by the odour and dust
sensors.
*Ion Control Mode
Negative ions will be released in an
increased rate and controls the ion
balance.
•Filters
1) Washable Active Carbon Filter
Absorbs odour elements.
Washable to maintain optimum
deodorization performance.
2) HEPA (High Efficiency
Particulate Air) Filter with
Microbial Control
High-efficiency particle collection in-
cluding pollen and dust.

E-2
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions should be followed, including the
following:
WARNING - To reduce the risk of electrical shock, fire or injury to persons:
•Read all instructions before using the air purifier.
•Use only a 220 volt outlet with a polarized receptacle.
•Do not use the air purifier if the power cord or plug is damaged or the connection to the wall
outlet is loosened.
•Periodically remove dust from the power plug.
•Do not insert fingers or foreign objects into the intake or air outlet.
•When removing the power plug, always hold the plug and never pull the cord.
Electrical shock and/or fire from short circuit may occur as a result.
• Do not remove the plug when your hands are wet.
•Do not use this air purifier near gas appliances or fireplaces.
•Remove the power plug from the wall outlet before cleaning the unit and when not using the
unit.
Electrical shock from bad insulation and/or fire from short circuit may occur as a result.
•If the power cord is damaged, it must be replaced by the manufacturer, its service agent,
Sharp authorized Service Centre or similarly qualified person in order to avoid a hazard.
•Do not operate when using aerosol insecticides or in rooms where there is oily residue, incense,
sparks from lit cigarettes, chemical fumes in the air or in very high humidity condition, such as a
bathroom.
•Be cautious when cleaning the air purifier. Strong corrosive cleansers may damage the exterior.
•Only Sharp Authorized Service Centre should service this air purifier. Contact the nearest Service
Centre for any problems, adjustments, or repairs.
NOTE - Radio or TV Interference
If this air purifier should cause interference to radio or television reception, try to correct the interference
by one or more of the following measures:
•Reorient or relocate the receiving antenna.
• Increase the separation distance between the air purifier and radio/TV receiver.
•Connect the equipment into an outlet on a circuit different from that to which the receiver is con-
nected.
•Consult the dealer or an experienced radio/TV technician for help.

ENGLISH
E-3
CAUTIONS CONCERNING OPERATION
• Do not block the intake and air outlet.
•Do not use the unit near or on hot objects, such as stoves or heaters or where it may come into
contact with steam.
•Do not lay the unit down when using.
• Always hold the handle on the back of the unit when moving it.
Holding the front panel when carrying may cause it to detach, thus dropping the unit and resulting in
bodily injury.
•Do not operate the unit without the filter.
•Do not wash and reuse HEPA filter .
It not only does not improve filter performance, it may cause electric shock or malfunction.
•Clean the exterior with a soft cloth only.
The unit surface may be damaged or cracked.
In addition, the sensors may malfunction as a result.
IMPORTANT SAFETY INSTRUCTIONS
INSTALLATION GUIDELINES
•During the operation of the product, please place the unit at least 2m away from equipments
which involve electric wave such as televisions, radios or wave clocks, in case electrical
interference occurs to such equipment.
•Avoid a location where the sensor is exposed to direct wind.
The unit may not operate properly.
•Avoid locations where curtains, etc., come into contact with the intake or air outlet.
Curtains, etc., may become dirty or a malfunction may occur.
•Avoid locations where the unit is exposed to condensation, due to drastic temperature changes.
(Use under appropriate conditions between 0 and 35˚C in the room.)
•Place on a stable surface with sufficient air circulation.
When placing the unit on a heavily carpeted area, it may cause the unit to vibrate slightly.
• Do not install when there is generation of lampblack, such as in a kitchen, etc.
The unit surface may crack or the sensor may malfunction as a result.
•Leave about 60cm of space from the wall.
The wall behind the air outlet may become dirty as time passes. When using the unit for extended
period of time in the same location, use a vinyl sheet, etc., to prevent the wall from becoming dirty. In
addition, periodically clean the wall.
FILTER GUIDELINES
•Follow the instructions in this manual for correct care and maintenance of the filters.

E-4
PART NAMES
MAIN UNIT DISPLAY
ILLUSTRATIVE DIAGRAM
Odour SensorDate Label
Main Unit
HEPA Filter
(blue / white)
Filter Support
Front Panel
Washable Active
Carbon Filter
AUTO Operation Indicator Light
Pollen Mode Indicator Light
Fan Speed Indicator Lights
Plasmacluster Ion Mode
Indicator Lights
Plasmacluster Ion Mode
Selection Button
Mode Selection Button
ION SHOWER Indicator Light
ION SHOWER Mode Button
POWE

ENGLISH
E-5
INCLUDED
•Operation manual
BACK
Blue light
When the Plasmacluster ion operation is in Clean Mode, or in AUTO Plasmaclus-
ter Ion Mode and the air in the room is impure, the light will be activated and the
unit will operate in Clean Mode.
Green light
When the Plasmacluster ion operation is in the Ion Control Mode during AUTO
Plasmacluster Ion Mode and the air in the room is clean, this light will be activated
and the unit will operate in Ion Control Mode.
Cycles of blue and green
When the Plasmacluster ion operation is in the ION SHOWER Mode ,
Plasmacluster Indicator Light will repeat its colour cycles between blue and green.
The colour changes according to
the air condition.
ABOUT THE CLEAN-SIGN
•The condition of the CLEAN-SIGN depends on the room air condition detected
by the Dust and Odour Sensors when the plug is inserted into the wall outlet.
•It is possible to have a green CLEAN-SIGN with impurities in the air at the time
that the air purifier was just introduced to the room environment. After a while,
however, the base impurity rate will be adjusted to detect room air condition
correctly.
DETERMINING THE BASE IMPURITY RATE
For the first 30 seconds after the power plug is inserted into the wall outlet, the
unit will check the conditions of the air. If operation is set to ON during this time,
the CLEAN-SIGN LIGHT will alternately flash in green, yellow and red.
Plasmacluster Indicator Light
(Please refer page E-9)
CLEAN - SIGN Light
POWER ON/OFF Button
ENGLISH
Green
Clean Slightly Impure Very Impure
Yellow Red
Air Outlet
Air Inlet
Rating Label
Power Cord
Power Plug
Handle
Dust Sensor

PREPARATION
To maintain the quality of the filters, they are installed in the main unit and packed in
plastic bags. Be sure to remove the filters from the plastic bags before using the unit.
Remove the filters
Remove the Front Panel.
E-6
Be sure to remove the power plug from the wall outlet.
FILTER INSTALLATION
Remove the Filter Support.
Pull the Front Panel on the
lower sides, and lift up.
4
2
1
3
Front Panel
(At open)
1
5
Push in the hooks on top, then pull the Filter Support.
Remove the HEPA Filter.
Remove the HEPA Filter from the
plastic bag.
Remove the Active Carbon Filter from
the carton box, and also remove from
the plastic bag.
Filter Support
HEPA Filter
HEPA Filter
Active Carbon Filter

ENGLISH
Ta b
(blue)
E-7
2
1
3
4
5
)
2
Install the filters
Place the HEPA Filter into the
main unit.
Do not install the filter backwards or the
unit will not operate properly.
Place the Filter Support
through the bands (2 places)
located at the corners of the
Active Carbon Filter.
Replace the Filter Support and Active
Carbon Filter back to the main unit.
Fill in the usage start date on the
Date Label.
Use the date as a guide for the Filter
Replacement schedule.
Replace the Front Panel.
Date Label
HEPA Filter
Filter Support
Band(blue)
Active Carbon Filter
Filter Support
Front Panel
Place the Front Panel from the obliquely upward,
then mount the hooks at the bottom.
Please make sure that the HEPA
Filter(blue) and the tab is placed in
proper direction.

OPERATION
MAIN UNIT OPERATION
E-8
Power ON/OFF Button
• Used to start operation (short beep) and stop operation (long beep)
•Plasmacluster Indicator Light and Fan Speed Indicator Light turn on/off.
•Unless unplug the power cord, the operation starts in the previous mode the
unit was operated in.
•When stop operation during ION SHOWER Operation, the unit will back to the
prior operation of ION SHOWER Operation.
MODE Selection Button
•The operation mode can be switched.
AUTO operation
The fan speed is automatically switched
(HIGH*, MEDIUM, SILENT) depending
on the amount of impurities in the air. The
sensors detect the impurities for efficient
air purification.
POLLEN mode operation
The unit will operate at HIGH* fan speed
for 10 minutes, then will alternate be-
tween MEDIUM and HIGH* for 20 min-
utes.
10 minutes: HIGH fan speed
20 minutes:
MEDIUM fan speed
20 minutes: HIGH fan speed
SILENT operation
The unit will operate quietly
using minimal air intake.
MEDIUM operation
The unit will operate at a fan
speed of MEDIUM.
MAX operation
The unit will operate at a fan
speed of MAX.
*HIGH fan speed is an intermediate speed
between MEDIUM and MAX.
Plasmacluster Ion Mode
Selection Button
Mode Selection Button

ENGLISH
AUTO
E-9
ION SHOWER Mode Button
Plasmacluster Ion Mode Selection Button
The Plasmacluster Ion mode can be switched.
The generation of ions will stop and the Plasmacluster Indicator Light
will go out.
LIGHTS ON/OFF Button
Switches the Plasmacluster Indicator Light and CLEAN-SIGN Light ei-
ther ON or OFF.
(Please press the Plasmacluster Ion Mode Selection Button for 3 seconds.)
CLEAN
The unit will constantly operate in the Clean Mode, in which the same
numbers of positive and negative ions are discharged. The
Plasmacluster Indicator Light is blue.
When pushing the ION SHOWER Mode button, the ION SHOWER
operation will be activated. (Direct start is available even when the unit is
not turned on.)
The concentrated Plasmacluster Ions (ION SHOWER) will be generated
in the room like a shower for 15 minutes, repeating the airflow cycles
between strong and gentle. (The Plasmacluster Indicator Light repeats
its colour cycles between blue and green.), and effectively controls the
airborne dust, pollen, mold, and allergen.
•When the operation finishes, the unit will return to the prior operation.
•When pushing the ION SHOWER button while the ION SHOWER
operation mode is working, the unit will return to the prior operation.
Plasmacluster Indicator Light
CLEAN - SIGN Light
ION SHOWER Mode Button
POWER ON/OFF Button
*Ion Control Mode
Negative ions will be
released in an
increased rate and
controls the ion
balance.
The unit will switch between Clean Mode and the Ion Control Mode*
automatically depending on the amount of impurities in the air as
detected by the dust and odour sensors. Clean Mode will operate for
10 minutes when the Auto function is selected.
OFF

E-10
CARE AND MAINTENANCE
To prevent dirt or stains on the main unit, clean as often as necessary. If stains are allowed to
remain, they may become hard to clean.
Wipe with a dry, soft cloth
For stubborn stains or dirt, use a soft cloth dampened with warm water.
Do not use volatile fluids
Benzene, paint thinner, polishing powder, etc., may damage the surface.
Do not use detergents
Detergent ingredients may damage the unit.
Keep the unit away from water
MAIN UNIT
FILTER
Washable Active Carbon Filter
SENSORS (DUST SENSOR, ODOUR SENSOR)
Sensor Cover
Hole of Odour Sensor
Clean the top surface of the Washable Active
Carbon Filter lightly with a vacuum cleaner.
Remove dust from the surface of the hole of the
sensors using a vacuum cleaner.
SENSOR FILTER CARE
(The sensor Filter is in the sensor cover.)
Detach the sensor filter and tap it lightly with your
hand to remove the dust.
If it is very dirty, wash it with water and then allow
it to dry thoroughly.
Sensor Cover
Care Cycle 1 month
Care Cycle 2 months
Care Cycle 2 months
Sensor Filter
It does not have a front and
a back.
To maintain optimum performance of this air purifier, please clean the unit including the sensor
and filters periodically.
When cleaning the unit, be sure to unplug the power cord, and never handle the plug with wet
hands. Electrical shock and/or bodily injury may occur as a result.

ENGLISH
E-11
WASHABLE ACTIVE CARBON FILTER CARE
HAND WASH ONLY!
DO NOT TUMBLE DRY!
Fill a large container with
lukewarm water, add a mild
kitchen detergent
and stir.
1
2
3
4
5
6
Care Cycle 2 months
Washable Active
Carbon Filter
Dilute as indicated
on the detergent
container.
Allow the filter to soak approxi-
mately 10 minutes before wash-
ing.
If the filter surface is
very dirty, scrub with
an old toothbrush.
Rinse thoroughly with clean
water.
If rinsing in a container,
be sure to rinse 3 to 4
times so that the odour
is rinsed thoroughly from
the filter.
Remove excess water.
CAUTION
The filter will be saturated with water
after rinsing. To decrease drying time,
wrap the filter in an old thick towel so
that excess water can be removed.
CAUTION
Some carbon may adhere to the towel, but it
is harmless.
Dry the filter outdoors if possi-
ble in a well ventilated area.
CAUTION
•The wet filter is heavy. Fix it securely for
drying to make sure it does not fall down.
•The filter takes longer time to dry in win-
ter, on rainy days. Wash it on a day when
the weather is good and dry it in the sun.
Move it indoors at night to prevent freez-
ing.
•Dry the filter outdoors in a well ventilated
area. If dried indoors, the water dripping
off the filter may soil your floor.
•Make sure that the activated carbon has
not shifted to one side of the filter. If it has,
distribute it evenly with your fingers.
•Let the filter dry thoroughly.
If used while the filter is still moist, then
the air that is exhausted from the main unit
will have an odour. It may take 1 or 2 days
to dry.
Reinstalling the Filters.
Reinstall the filters as shown on Page
E-6,7

E-12
CARE AND MAINTENANCE
FILTER REPLACEMENT GUIDELINES
The replacement period differs depending on the room environment, the usage hours
and location of the Air Purifier.
If dust or odours persists, replace the filters.
(Refer to “Please read before operating your new Air Purifier”)
HEPA Filter / Washable Active Carbon Filter
Guide for filter replacement timing
•Filter life can be greatly reduced in poor environment.
The presence of cigarette smoke, pet dander and other concentrations of airborne particles
will cause filters to become clogged in less time. Please check filters regularly and replace
as needed.
Up to 5 years after opening
Replacement Filters Model • HEPA Filter : 1 unit
FZ-S51SEF • Washable Active Carbon Filter : 1 unit
REPLACING THE FILTERS
1. See page E-6,7 for directions on how to install the filters when replacing.
2. Fill in the usage start date of the filters on the Date Label.
Disposal of Filters
Please dispose of replaced filters according to the local disposal laws and regulations.
HEPA Filter Materials:
• Filter: Polypropylene • Frame: Polyester
Active Carbon Filter Materials:
• Deodorizer: Activated charcoal • Net: Polypropylene 60%, Polyester 40%
SPECIFICATIONS
Model
Power supply
Fan Speed Adjustment
Rated Power
Air Flow Volume (m3/hour)
Applicable Floor Surface
Cord Length
Dimensions
Weight
Fan
Speed
Operation
~38m2*1
2.0m
338mm(W)x207mm(D)x620mm(H)
6.5kg
MAX
46 W
306
MED
8.6W
138
SILENT
3.7 W
30
*1
FU-S51A
220V 50Hz
•The applicable floor surface area is appropriate for operating the unit at maximum fan speed.
•Applicable floor surface area indicates the space where a certain amount of dust particles can be
removed in 30 minutes.
Standby Power In order to operate the electrical circuits while the power plug is inserted in
the wall outlet, this product consumes about 0.7W of standby power.
For energy conservation, unplug the power cord when the unit is not in use.

ENGLISH
E-13
Before calling for repair, please review the list below, since the problem may not be a unit malfunction.
SYMPTOM REMEDY (not a malfunction)
Odours and smoke are not
removed.
•Clean or replace the filters if they appear to be heavily soiled.
(Refer to E-11, E-12)
The CLEAN-SIGN Light lights
green even when the air is
impure.
•The air could be impure at the time the unit was plugged in.
(Refer to E-5) Pull out the plug from the electrical outlet, and
insert the plug one minute later.
The CLEAN-SIGN Light lights
yellow or red even when the air
is clean.
•The sensitivity of the sensors become unstable when the
opening of the odour sensor or dust sensor is dirty or is clogged.
Clean the dust around the sensor opening using a vacuum
cleaner. (Refer to E-10)
The Plasmacluster Indicator
Light remains green (or blue)
and does not change.
•When in Ion Control Mode (or Clean Mode), the Plasmaclus-
ter Indicator Light colour will not change.
•Clicking sound is emitted when the unit is in the Ion Control
Mode, and ticking sound is emitted when the unit is generating
ions.
If the sound is irritating, set the unit away from you.
A clicking or ticking sound is
heard from the unit.
TROUBLESHOOTING
ERROR DISPLAY
LAMP INDICATION REMEDY
The “Silent” Fan Speed Indica-
tor Light blinks.
Fan motor disconnected or abnormal.
Operation stops.
•Pressing the POWER ON/OFF button will reset the error
display, but if error occurs again, contact the Sharp Service
Centre.
The discharged air has an aroma
or odour.
•Check to see if the filters are heavily soiled.
Replace the filters.
•Plasmacluster Air Purifiers emit small traces of ozone which
may produce an odour. These ozone emissions are well below
safety levels .
The unit does not operate when
cigarette smoke is in the air.
•Is the unit installed in a location that is difficult for the sensor
to detect cigarette smoke?
• Are the dust or odour sensor openings blocked or clogged?
(In this case, clean the openings.) (Refer to E-10)
The Plasmacluster Indicator
Light or the CLEAN-SIGN Light
will not activate.
•Check to see if the Lights OFF Mode is selected. If so, then
press the Plasmacluster Ion Mode Selection Button for 3
seconds to activate the indicator lights.
(Refer to E-9)
Plasmacluster Indicator Light
(repeats colour cycles between
blue and green ) •The ION SHOWER operation is working.

注意
•本空氣清新機用於去除空氣中懸浮的灰塵和異味,而不能去除有害氣體(如:香煙煙霧中的一氧化碳)。
如果異味的源頭依然存在,異味將不能徹底去除(如:來自建築材料或寵物身上的異味)。
•建議吸煙時將窗戶稍微打開,以便空氣流通。
聲寶空氣清新機操作原理
空氣清新機經吸氣口吸入室內空氣,使其通過機內的活性碳過濾網
(除臭過濾網)和HEPA過濾網(集塵過濾網),然後從吹出口排出。空氣
清新機通過其內部風扇的運行不斷重複此過程。
當空氣通過時,HEPA過濾網能夠除去灰塵粒子達百份之99.97(過濾
0.3微米之微塵粒子時)。當異味成分多次經過活性碳過濾網時,便逐
步被吸收。(異味成分也被HEPA過濾網吸收)
有些已被過濾網吸收的異味成分可能會離開過濾網並經吹出口被排
出,因而產生額外的異味。根據不同的使用環境,尤其是這產品應用
於比家居使用環境嚴重的情況下,這些異味可能在比預期更短的時間
內變得強烈。如異味持續,表示過濾網已完全耗盡,請選購過濾網更
換配件。

中文
特點
C-1
中文
多謝您購買聲寶空氣清新機。請仔細閱讀此說
明書,以瞭解正確使用資訊。使用本產品之
前,請務必閱讀“重要安全事項”這一節。
閱讀後請妥善保管此說明書以便日後查閱。
目錄
強力離子簇除菌
新的強力離子簇除菌操作模式會放出高
密度的離子簇,並且有效除去花粉和霉
菌,控制空氣中的病毒、霉菌和過敏原
的活動。
離子簇控制
您的新空氣清新機根據室內空氣狀況控
制負離子和正離子的比例。
• 淨化模式
釋放出大約同等數量的正離子和負離
子。
• 自動離子簇模式
本機將根據灰塵和異味感應器感測空氣
的污濁程度,從而自動轉換為淨化模式
或離子控制模式*。
* 離子控制模式
負離子會以增加的比率釋放並控制離
子的平衡。
• 過濾網
1) 可清洗的活性碳過濾網
吸收異味成份。
清洗本過濾網可維持其最佳的除臭效
能。
2) 配備微生物控制的HEPA(高效能微塵)
過濾網
過濾網可高效吸附微粒,包括花粉和
灰塵。
重要安全事項 ........................... C-2
•警告 ................................. C-2
•操作注意事項 ......................... C-3
•安裝指南 .............................C-3
•過濾網指南 ........................... C-3
各部份名稱 ......................... C-4
•主機部份 .............................C-4
•分解圖 ............................... C-4
•背部 ................................. C-5
•附件 ................................. C-5
準備工作 ........................... C-6
•安裝過濾網 ........................... C-6
操作 ............................... C-8
•主機操作 .............................C-8
保養與清潔. ....................... C-10
•主機 ............................... C-10
•過濾網 ............................. C-10
•感應器 ............................. C-10
•保養可清洗的活性碳過濾網 ........... C-11
•過濾網更換指南 ..................... C-12
規格 .............................. C-12
維修前的檢查事項 .................. C-13

C-2
重要安全事項
使用電器時,必須遵守基本安全預防措施,包括以下各方面:
警告- -
- -
- 為了減少電擊、火災或受傷等危險:
•在使用空氣清新機之前請閱讀所有注意事項。
•只能使用220V插座。
•如果電源線或插頭已經損壞,或者牆上的電源插座已鬆脫,請勿使用空氣清新機。
•定期清除電源插頭上的灰塵。
•請勿將手指或異物插入吸氣或吹出口。
•當拔掉電源插頭時,必須緊握插頭而不要拉扯電線。
否則可能導致電擊或因短路引起火災。
•手濕時請勿拔掉電源插頭。
•在氣體設備或壁爐附近請勿使用空氣清新機。
•清潔本機或不使用本機時,請將插頭從牆上的電源插座上拔掉。
否則可能導致因絕緣不良而引起電擊或因短路而引起火災。
•如果電源線損壞,必須由製造商或其代理、聲寶公司特約維修機構或具有同等資格的人員負責更
換,以免發生危險。
•當使用噴霧殺蟲劑時請勿使用本機,或房間內有油渣、焚香時的煙、點煙時的火苗、空氣中有化學
氣味或浴室等濕氣很重的地方也不要使用本機。
•清潔空氣清新機時請加以小心。具強力腐蝕性的清潔劑會損壞本機表面。
•只有聲寶特約維修人員方可維修本空氣清新機,當需要調校、修理或出現問題時,請聯絡就近的維
修機構。
注意- -
- -
- 收音機或電視干擾
如果本空氣清新機對收音機或電視接收造成干擾,請嘗試以下列其中一項或多項措施修正干擾:
•重新調整或重新放置接收天線。
•增加空氣清新機和收音機/電視接收器的距離。
•將本設備的電源與接收器的電源連接到不同的插座。
•如需協助,請聯絡經銷商或專業的收音機/電視技術人員。

中文
C-3
重要安全事項
操作的注意事項
•請勿堵塞吸氣口和吹出口。
•不要靠近或在熱源物體上(如爐灶或暖爐式可能接觸到蒸汽的場所)使用本機。
•使用時請勿平放本機。
•移動本機時,須一直緊握主機後邊的手柄。
移動時若握住前面板可能導致前面板脫落,致使主機墜落,造成人身傷害。
•請勿在沒有過濾網的情況下操作本機。
•請勿清洗和再用HEPA過濾網。
•只能使用軟布清潔本機表面。
否則本機可能會損壞或破裂。
此外,還可能導致感應器故障。
安裝指南
•操作本機時,請將本機置於帶有電波的設備(如電視機、收音機或時鐘)至少2米以外。以防產生電
波干擾。
•請勿安裝在感應器直接對住風口的地方。
否則可能會影響本機正常工作。
•請勿安裝在窗簾等物件可能會接觸到吸氣口或吹出口的地方。
否則該物件可能會被污染或導致本機故障。
•請勿安裝在由於溫度劇烈變化而導致本機直接暴露於冷凝環境的地方。
(在5至35度室溫的適當情況下使用。)
•安裝必須穩固,且通風良好。
把本機放置在鋪有厚地毯的地方時,可能導致本機微微震動。
•請勿安裝在會產生黑煙的地方(如廚房等)。
否則可能會導致本機表面破裂或感應器故障。
•遠離牆壁大約60厘米。
排氣口後邊的牆壁可能會隨著時間變髒,當在同一位置長時間使用本機時,請在牆上貼一張軟膠
墊,以免牆壁變髒。此外,請可以定期清潔牆壁。
過濾網指南
•遵照說明書指示,了解正確保養和清潔過濾網的方法。

C-4
各部份名稱
主機部份
分解圖
異味感應器
主機
HEPA過濾網
(藍色/白色)
可清洗的活性碳過濾網
日期標籤
過濾網框架
前面板
離子簇模式選擇按鈕
強力離子簇除菌模式按鈕
強力離子簇除菌指示燈
模式選擇按鈕
離子簇模式指示燈
風速指示燈
花粉模式指示燈
自動操作指示燈
Table of contents
Other Sharp Air Cleaner manuals

Sharp
Sharp FZ-80SEF User manual

Sharp
Sharp FP-H50A User manual

Sharp
Sharp KC-D41R User manual

Sharp
Sharp FU-D40A User manual

Sharp
Sharp FU-S25E User manual

Sharp
Sharp FU-P60S User manual

Sharp
Sharp KI-L60TA User manual

Sharp
Sharp FZ-6400SF User manual

Sharp
Sharp Plasmacluster FP-A28C User manual

Sharp
Sharp KI-L80 User manual

Sharp
Sharp Plasmacluster KC-830U User manual

Sharp
Sharp FP-F40A User manual

Sharp
Sharp Plasmacluster IG-CL15U Setup guide

Sharp
Sharp FU-A80TA User manual

Sharp
Sharp FP-F40E User manual

Sharp
Sharp UA-KIL80E User manual

Sharp
Sharp FP-FM40E User manual

Sharp
Sharp QNET FP-E50E User manual

Sharp
Sharp FP-F50U-W User manual

Sharp
Sharp Plasmacluster KC-30TX1 User manual