STEP Connect ModBus
RS
Part numbers:
EM-CF-GA,
EM-CF-GA,
EM-CF-GA,
EM-CF-GA
NOTE: The ModBus connector should NOT be on the Modbus cable when it is pushed through the rubberized gland. This
gland will not self-seal if the connector is pushed through the rubberized gland and the NEMA rating will be lost.
. Using the supplied ModBus connector gently press the connector into place (see Figure ).
. Push the external ModBus cable through the rubberized gland at the back of the charger (this will self-seal). Attach
the external wires to the internal wire connector.
. Gently tuck the wiring into the space and secure the back of the charger.
Security Note: The ModBus RTU is an open protocol, and it is the responsibility of the installer to ensure the security of the
wiring of these connections to prevent tampering.
STEP A ModBus Connection
Part Numbers
EM-CF-BA,
EM-CF-BA
NOTE: The ModBus connector should NOT be on the Modbus cable when it is pushed through the rubberized gland. This
gland will not self-seal if the connector is pushed through the rubberized gland and the NEMA rating will be lost.
. Push ModBus cable through rubberized gland. The rubberized gland will self-seal around the cable.
. Snake cable up to the ModBus connector.
. Remove the ModBus plug that is in place and connect to the cable.
. Reinsert the ModBus plug into the ModBus connector.
STEP B Set ModBus
Termination Switch
Part numbers:
EM-CF-GA,
EM-CF-GA,
EM-CF-GA,
EM-CF-GA
SW- (left side) labelled A RS is the Termination switch. This switch should be in the ON position for the Parent unit or
in the OFF position for a Child unit, unless that Child is the last Child in the daisy chain, then it must be ON.
STEP C Set ModBus
Termination Switch
Applicable to Child
units ONLY with the
following part
numbers:
EM-CF-GA,
EM-CF-GA
SW- (right side) labelled M RS Term is the Termination switch. For the child units the Termination switch must be set
to OFF, unless the unit is the last one in the daisy chain, then the switch must be set to ON.
STEP Connect External
Remote Control
Interface – (Optional).
Part numbers:
EM-CF-FA,
EM-CF-FA,
EM-CF-GA,
EM-CF-GA,
EM-CF-GA,
EM-CF-GA
The Siemens VersiCharge has a Remote Control Interface that allows charging to be controlled by an external device.
Examples include demand response switches, building automation systems, digital sensors, etc.
• To wire a digital input into the dry contact in the connection area located inside of the VersiCharge, please refer to the
complete VersiCharge AC Series Installation and Operation Manual at www.usa.siemens.com/versicharge for more
detail.
• When the external contact is closed, the alternate input will control the VersiCharge, preventing it from entering the
‘Charging’ state.
• The status output is a switch that indicates charging status. When the contacts are closed, the unit is in charging state.
Pin # Label Description
7 Utility_1 Utility lockout (dry contact input; locked when closed)
9 Utility_2
STEP Check the System Turn the power on; the white Power Available light should illuminate. If it does not, verify that the outlet or wire is putting
out or V using the voltmeter.
With the Power Available light on, plug the Electric Vehicle Supply Equipment (EVSE) cable into the car. If you have any fault
lights, please see the HMI figures in the beginning of this manual.
Siemens VersiCharge Mobile App: Download the VersiCharge mobile app to your smartphone to get started using your
charger. Find these applications at either Google Play (https://play.google.com/store), or iOS stores (https://www.apple.com/
ios/app-store/).