Table of contents
SIRIUS 3RW5 PROFIBUS communication module
Equipment Manual, 02/2020, A5E35633549002A/RS-AC/003 5
8 Maintenance and service .................................................................................................................... 103
8.1 Firmware update ...................................................................................................................103
8.1.1 Performing firmware update with micro SD card (3RW5 HMI High Feature) .......................105
8.2 Replacing the 3RW5 communication module.......................................................................106
8.3 Restoring factory settings .....................................................................................................108
9 Technical data .................................................................................................................................... 111
9.1 Technical data in Siemens Industry Online Support.............................................................111
10 Dimension drawings............................................................................................................................ 113
10.1 CAx data ...............................................................................................................................113
10.2 Drilling patterns for 3RW5 communication module on the 3RW50 soft starter ....................114
11 Circuit diagrams .................................................................................................................................. 117
11.1 CAx data ...............................................................................................................................117
A Appendix............................................................................................................................................. 119
A.1 Process data and process images........................................................................................119
A.2 Data formats .........................................................................................................................123
A.2.1 Current values as percentages.............................................................................................123
A.2.2 Statistic data .........................................................................................................................124
A.2.3 Maximum pointer ..................................................................................................................124
A.3 Data sets ...............................................................................................................................125
A.3.1 Byte arrangement .................................................................................................................126
A.3.2 Specifications........................................................................................................................126
A.3.3 Commands............................................................................................................................127
A.3.3.1 Data set 93: Commands .......................................................................................................127
A.3.4 3RW5 communication module (slot 1)..................................................................................129
A.3.4.1 Data set 131: Parameter communication (slot 1) .................................................................129
A.3.5 3RW5 soft starter (slot 2) ......................................................................................................130
A.3.5.1 Data set 68: Process image output (PIQ) .............................................................................130
A.3.5.2 Data set 69: Process image input (PII) .................................................................................133
A.3.5.3 Data set 92: Soft starter diagnostics (slot 2).........................................................................135
A.3.5.4 Data set 94: Measured values ..............................................................................................140
A.3.5.5 Data set 95: Statistic data.....................................................................................................141
A.3.5.6 Data set 96: Maximum pointer..............................................................................................143
A.3.5.7 Data sets 131, 141, and 151: Parameter basic functions - Set 1, 2, and 3 ..........................145
A.3.5.8 Data sets 132, 142, and 152: Parameter extended functions 1 - Set 1, 2, and 3 ................157
A.3.5.9 Data set 133: Parameter extended functions 2 ....................................................................160
A.3.5.10 Data set 134: Parameter Maintenance .................................................................................162
A.3.5.11 Data set 135: Parameter cyclic process image ....................................................................
163
A.3.6 3RW5 HMI High Feature (slot 3) ..........................................................................................164
A.3.6.1 Data set 92: HMI diagnostics (slot 3)....................................................................................164
A.3.6.2 Data set 131: HMI parameter (slot 3) ...................................................................................166
A.3.7 I&M data................................................................................................................................170
A.3.7.1 Data set 231: I&M0 - Device identification............................................................................171
A.3.7.2 Data set 232: I&M1 - Equipment identifier............................................................................172
A.3.7.3 Data set 233: I&M2 - Installation...........................................................................................173
A.3.7.4 Data set 234: I&M3 - Description..........................................................................................174