manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Siemens
  6. •
  7. Controllers
  8. •
  9. Siemens REA23M User manual

Siemens REA23M User manual

Commissioning and quick start
1. Remove controller from its base and open
cover of the battery compartment.
2. Remove the black battery transit tab.
The controller will switch itself on.
3. Close the battery compartment and replace
the controller.
4. Switch on the boiler.
Selecting the operating mode
The operating mode selector enables you
to select 5 different operating modes:
•Automatic operation with a maximum of
3 heating periods
•Continuously comfort mode
•Continuously economy mode
•Continuously frost protection mode
•24-hour mode with current comfort setpoint
Changing temporarily the current
setpoint temperature
° C
The change is
maintained until
the next switching
point is reached!
1.When pressing the or button for
the first time, the currently valid setpoint
temperature will be displayed. It can be
readjusted in increments of 0.2 °C
(max. +/-4 °C).
2. After 3 seconds, the initial display will
automatically appear again.
Changing temporarily the
temperature setpoint (savings tip)
In operating modes and ,
this button can be pressed to make a
manual change from comfort to
economy mode, or vice versa.
The change will automatically be
canceled when reaching the next
switching point or when selecting
another operating mode.
Symbols Burner active Economy setpoint 1 heating
period
“Time” menu Error message Setpoint frost
protection 2 heating
periods
T“Temperature”
menu Automatic
operation Setpoint re-mote
operation 3 heating
periods
“Heating
periods” menu Continuously
comfort mode Absence setpoint Current weekday
“Absence”
menu
Continuously
economy
mode Actual room-
temperature Workingday group
Battery change Frost
protection Actual outside
temperature (*) Weekend group
Remote
operation 24-hour mode Hot water temp.
setpoint (*) Entire week
Absence Comfort
setpoint
Actual boiler water
temp. (*)
Relative modu-
lation level in % (*)
Time schedule
(*) Display only possible if these values are provided by the boiler.
Functions of
the ESC-button the setting knob and the OK-button
ESC-button
ESC
Press the ESC-button to return
to the menu level previously
activated or to leave the menu
level in a number of steps until
you reach the initial display
(the settings currently
displayed will be accepted).
+
ESC OK
OK-button:
OK
•You access the menu level
•You activate the menu
•You save the inputs
•You switch to the next
menu item
•You accept the menu item
Setting knob:
•Setting knob is operative in menu levels only !
•You go from one menu to the next
•You change the setting variables (temperature in increments of
0.2 °C, time in increments of hours and minutes)
•You select predefined functions
Setting the time of day and the weekday
OK
OK h
OK hOK
ESC
If no button is pressed for 20 seconds, the setting
displayed will be accepted and the initial display
will appear again.
1. OK-button: You access the menu level;
the clock flashes.
2. OK-button: You accept the menu;
the hours flash.
3. Setting knob: Set the current hour.
4. OK-button: You save the input;
the minutes flash.
5. Setting knob: Set the current minute.
6. OK-button: You save the input;
the weekday flashes.
7. Setting knob: Select the current weekday.
8. Press the ESC-button to return to the menu
level: the T menu flashes
(Change not necessarily required; press the
ESC-button again to return to the initial display).
Changing temperatures long-term
OK
OK
OK ° C
OK
OK ° C
OK
OK
° C OK
OK
° C
ESC
ESC
If no button is pressed for 20 seconds, the setting
displayed will be accepted and the initial display
will appear again.
1. OK-button: You access the menu level the
clock flashes.
2. Setting knob: Clockwise to the T menu.
3. OK-button: You accept the menu;
symbol flashes.
4. OK-button: You accept ;
the setpoint flashes.
5. Setting knob: Set the comfort temperature
6. OK-button: You save the input;
symbol
flashes.
7. OK-button: You accept ;
the setpoint flashes.
8. Setting knob: Set the economy temperature.
9. OK-button: You save the input;
symbol
flashes.
10. OK-button: You accept ;
the setpoint flashes.
11. Setting knob: Set the frost protection
temperature.
12. OK-button: You save the input;
symbol flashes.
13. OK-button: You accept ;
the setpoint flashes.
14. Setting knob: Set the temperature setpoint
while remote operation is active.
15. Press the ESC-button to return to the menu
level: The heating periods
menu flashes
(Change not necessarily required; press the ESC-
button again to return to the initial display.)
Siemens / Building Technologies / HVAC Products B2217en 26.03.2007
en
Operating Instruction
REA23M
Settings for automatic operation with 2 heating periods
OK
OK
OK
OK
OK
h
OK h
OK ° C
OK
OK h
OK h
OK ° C
ESC
ESC
/ESC ESC
If no button is pressed for 20 seconds, the setting
displayed will be accepted and the initial display will
appear again.
1.OK-button: You access the menu level;
the clock flashes.
2.Setting knob: Clockwise to menu,
flashes.
3.OK-button: You accept the menu;
the day selection symbol
flashes.
4.Setting knob: Select the days, the working
days, the weekend or the week.
5.OK-button: You save the selection made;
heating period flashes.
6.Setting knob: Counterclockwise to
7.OK-button: Accept ;
heating period 1 flashes.
7.OK-button: You accept heating period 1;
start time of heating period 1
flashes.
9.Setting knob: Set the start time of
comfort period 1.
10.OK-button: You save the input; end time of
heating period 1 flashes.
11.Setting knob: Set the end time of
comfort period 1.
12.OK-button: You save the input; setpoint of
heating period 1 flashes.
13.Setting knob: Set the setpoint of
comfort period 1.
14.OK-button: You save the input;
heating period 2 flashes.
15.OK-button: You accept heating period 2; start
time of heating period 2 flashes.
16.Setting knob: Set the start time of
comfort period 2.
17.OK-button: You save the input; end time of
heating period 2 flashes.
18.Setting knob: Set the end time of
comfort period 2.
19.OK-button: You save the input; setpoint
of heating period 2 flashes.
20.Setting knob: Set the setpoint of
heating period 2.
21.Press the ESC-button to return to the comfort
periods menu: Menu item comfort
periods flashes.
22.Setting knob: To menu item or
heating periods
(Change not necessarily required; press the ESC-
button several times to leave the menu level in
several steps, thus returning to the initial display.)
Settings for automatic operation with 1 or 3 heating periods
The procedure to be followed is the same as that for automatic operation with 2 heating periods. The only
difference being that, in addition, a setpoint for heating periods 3 can be entered (standard setting 21 °C)
Absence / holidays
OK
OK
OK
OK
° C
ESC
ESC
If no button is pressed for 20 seconds, the setting
displayed will be accepted and the initial display will
appear again.
1.OK-button: You access the menu level;
the clock flashes.
2.Setting knob: To , menu flashes.
3.OK-button: Accept ;
symbol flashes.
4.Setting knob: Set the start (weekday) of your
absence.
5.OK-button: You save the input; the number of
days flash.
6.Setting knob: Set the duration of your absence;
number of days (max. 99 days)
7.OK-button: You save the input;
setpoint flashes.
8.Setting knob: Set the temperature.
9.Press the ESC-button to return to the menu level;
the clock flashes.
(Change not necessarily required; press the
ESC-button again to return to the initial display.)
Siemens / Building Technologies / HVAC Products B2217en 26.03.2007
24-hour operation
24-hour operation with only one heating period
(the heating period will automatically be
generated from the current 24-hour program).
Start of the first heating period, end of the last
heating period, plus the currently adjusted
comfort temperature setpoint.
Retrieving the default values
Press the button behind the small opening for at
least one second, thus resetting the user-specific
and the “Permanent-self-learning operating mode”
as well as display of flow temperature, outside
temperature and d.h.w. setpoint to their default
values (the heating engineer settings will not be
changed).
The clock starts at 12:00.
When making a reset, all display fields will light up.
Caution: If the controller is removed from its base
for more than 60 seconds, an error
message will appear on the display.
When sliding the controller back to its
base, the error message must
disappear after 2 minutes at the latest.
Without inserted batteries, reset
functions correctly for a maximum
of 15 seconds only after removing
REA23M from its base.
Default values
Factory settings for heating
Operating mode
Start of continuous operation 00:00 00:00 00:00
End of continuous operations 24:00 24:00 24:00
Setpoint of comfort mode 19 °C
Setpoint of economy mode 16 °C
Setpoint frost protection 5 °C
Setpoint
remote operation 10 °C
Setpoint absence 12 °C
Operating mode
Selected periods
Start of period 1 07:00 06:00 06:00
End of period 1 23:00 08:00 08:00
Start of period 2 17:00 11:00
End of period 2 22:00 13:00
Start of period 3 17:00
End of period 3 22:00
Setpoint of period 1 19 °C 19 °C 19 °C
Setpoint of period 2 20 °C 20 °C
Setpoint of period 3 21 °C
Setpoints and see above
Changing the batteries
2 Alkaline batteries type AA 1.5 V
When this symbol appears, the batteries must
be replaced within 3 months.
1. Remove controller from its base.
2. Open battery compartment at the rear and
replace the batteries.
3. Close battery compartment and replace the
controller.
Note:
When changing the batteries, the current data are
maintained for a maximum of one minute.

Other Siemens Controllers manuals

Siemens RVP540 Operator's manual

Siemens

Siemens RVP540 Operator's manual

Siemens SIRIUS 3RW30 User manual

Siemens

Siemens SIRIUS 3RW30 User manual

Siemens sinamics dcp User manual

Siemens

Siemens sinamics dcp User manual

Siemens Powermite 599 Series Owner's manual

Siemens

Siemens Powermite 599 Series Owner's manual

Siemens ACR12.3 1 Series User manual

Siemens

Siemens ACR12.3 1 Series User manual

Siemens SIMATIC ET 200SP User manual

Siemens

Siemens SIMATIC ET 200SP User manual

Siemens SIMOTION P350-3 User manual

Siemens

Siemens SIMOTION P350-3 User manual

Siemens SIMATIC SIS compact User manual

Siemens

Siemens SIMATIC SIS compact User manual

Siemens Acvatix SAX61 MO Series Operator's manual

Siemens

Siemens Acvatix SAX61 MO Series Operator's manual

Siemens SIMATIC S7 User manual

Siemens

Siemens SIMATIC S7 User manual

Siemens SQM5 Series Owner's manual

Siemens

Siemens SQM5 Series Owner's manual

Siemens Ertec 400 User manual

Siemens

Siemens Ertec 400 User manual

Siemens SIMATIC NET SCALANCE WLC711 User manual

Siemens

Siemens SIMATIC NET SCALANCE WLC711 User manual

Siemens SKP Series Owner's manual

Siemens

Siemens SKP Series Owner's manual

Siemens SITRANS LUT400 User manual

Siemens

Siemens SITRANS LUT400 User manual

Siemens SIMATIC S5-100U User manual

Siemens

Siemens SIMATIC S5-100U User manual

Siemens 3VL971 Series User manual

Siemens

Siemens 3VL971 Series User manual

Siemens Flowrite 599 Series Owner's manual

Siemens

Siemens Flowrite 599 Series Owner's manual

Siemens RLU2 Series User manual

Siemens

Siemens RLU2 Series User manual

Siemens ATC5300 User manual

Siemens

Siemens ATC5300 User manual

Siemens SINAMICS S120 Quick start guide

Siemens

Siemens SINAMICS S120 Quick start guide

Siemens N350E Service manual

Siemens

Siemens N350E Service manual

Siemens 5WG1 513-1AB11 User manual

Siemens

Siemens 5WG1 513-1AB11 User manual

Siemens SIPART DR19 User manual

Siemens

Siemens SIPART DR19 User manual

Popular Controllers manuals by other brands

Norac UC4+ installation manual

Norac

Norac UC4+ installation manual

Woodward GCP-30 Series manual

Woodward

Woodward GCP-30 Series manual

Trox VFC series operating manual

Trox

Trox VFC series operating manual

Honeywell MN7220 Product data

Honeywell

Honeywell MN7220 Product data

Binks 84-346 Service manual

Binks

Binks 84-346 Service manual

Solar Redarc SRPA0120 manual

Solar

Solar Redarc SRPA0120 manual

Triconex Trident Planning and installation guide

Triconex

Triconex Trident Planning and installation guide

LEGRAND Wattstopper WRC-15 Series installation instructions

LEGRAND

LEGRAND Wattstopper WRC-15 Series installation instructions

Hitachi PC-ARFG2-M Installation & maintenance manual

Hitachi

Hitachi PC-ARFG2-M Installation & maintenance manual

Contrec 500 Series Operation manual

Contrec

Contrec 500 Series Operation manual

TREND IQ4E installation instructions

TREND

TREND IQ4E installation instructions

ICT Protege SE installation manual

ICT

ICT Protege SE installation manual

Graco 217314 Instructions-parts list

Graco

Graco 217314 Instructions-parts list

Power Electronics VS65 Series Programming and Software Manual

Power Electronics

Power Electronics VS65 Series Programming and Software Manual

SKYDANCE VP quick start guide

SKYDANCE

SKYDANCE VP quick start guide

YASKAWA SI-P3V installation manual

YASKAWA

YASKAWA SI-P3V installation manual

Artistic Licence matisse Light-Switch II user guide

Artistic Licence

Artistic Licence matisse Light-Switch II user guide

Shinko BCS2R Series manual

Shinko

Shinko BCS2R Series manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.