Connected Home Radiator Valve Actuator ZigBee, wireless
SSA911.02ZB
Wireless radiator valve actuator, works with SIEMENS Connected Home
●RF-controlled actuator communication based on ZigBee protocol (2.4 GHz,
bidirectional)
●Connects and operates with Connected Home hub and receiver
●Battery-operated with commercially available 1.5 V AA batteries
●Valve thread connection M30x1.5 mm
●Nominal stroke 5 mm
●Valve positioning force 90 N
●Adapts automatically to valve
●Integrated temperature sensor and PI controller
●Set temperature on device or via app
A6V13722083_de--_a
Smart Infrastructure
2022-12-12
2
Siemens
A6V13722083_de--_a
Smart Infrastructure
2022-12-12
Application
●The SSA911.02ZB wireless radiator valve actuator is designed to work on radiator
valves from different manufacturers in HVAC applications using M30x1.5 thread. It
operates the valve to control water flow and room temperature.
●The valve actuator works in combination with Connected Home Hub GTW100ZB and
wireless repeater RCR110.2ZB (as an option)
●One Connected Home Hub GTW100ZB can pair with up to 32 radiator valve actuators in
parallel. Wireless repeaters RCR110.2ZB extend the range of the network.
Siemens Connected Home
(App)
GTW100ZB
SSA911.02ZB
RCR110.2ZB
Basic functions
Functions
Description
Communication
The communication protocol is ZigBee.
ZigBee is a low-power wireless mesh networking protocol and enables device-to-device and
device-to-cloud communications. ZigBee is based on IEEE 802.15.4 radio standard.
Parallel operation
A single Connected Home Hub GTW100ZB can pair up to 32 actuators.
Pairing
The Connected Home app pairs the devices.
Calibration
The actuator automatically detects the end positions of the radiator valve.
Temperature
setting
Push buttons on the device set the setpoint temperature
Type summary
Type
Article number
Description
SSA911.02ZB
S55181-A105
Radiator valve actuator
3
Siemens
A6V13722083_de--_a
Smart Infrastructure
2022-12-12
Scope of delivery
●Radiator valve actuator SSA911.02ZB
●2 AA alkaline batteries (LR6)
●Quick guide (A5W00205935A)
●Third-party valve adapter for Danfoss (RA, RAV, RAVL)
●Screw and nut for adapter
Equipment combinations
Siemens valves
The SSA911.02ZB is suited for the following Siemens radiator valve types:
Type
kVS
[m3/h]
V

[l/h]
PN
Data sheet
VDN1.., VEN1..
Radiator valves
0.63…1.41
-
10
N2105
VDN2.., VEN2.., VUN2..
N2106
VD1..CLC..
1.9…2.6
N2103
VD1.., VE1.. *
Radiator valves
0.25…3.4
-
N2145
VD2.., VE2.., VU2.. *
N2146
VPD/VPE/VPU..
Radiator PICV
-
20…135
10
A6V13599366
kVS
=
Flow nominal value for cold water (5. 30 °C) through a fully opened valve (H100), at differential pressure
of 100kPa (1 bar)
V

=
Volume flow
*
No longer available
Third-party valves without adapter
The SSA911.02ZB can operate third-party radiator valves without adapter, provided they
have a M30x1.5 mm connecting thread and meet the following requirements:
Force
90 N nominal
Fully closed
x > 9,0 mm
Fully open
y ≤ 14,5 mm
Valve pre-adjustment / kV-limitation
For valve pre-adjustments, refer to the relevant technical documentation on the valves.
Ensure a minimum valve stroke of > 0.5 mm.
4
Siemens
A6V13722083_de--_a
Smart Infrastructure
2022-12-12
Accessories
Adapters for SSA911.02ZB for use with third-party valves
Type
Article number
For use with...
Adapter thread
AV52
BPZ:AV52
Comap
M28x1,5
AV56
BPZ:AV56
Giacomini
-
AV57
BPZ:AV57
Herz
M28x1,5
AV58
BPZ:AV58
Oventrop < 2002
M30x1
AV59
BPZ:AV59
Vaillant
-
AV60
BPZ:AV60
TA < 2002
M28x1,5
AV61
BPZ:AV561
MMA Markaryd
M28x1.5
Contact your local office or branch for information on adapters for other radiator valve types
and manufacturers.
5
Siemens
A6V13722083_de--_a
Smart Infrastructure
2022-12-12
Third-party valve adapter
Adapters for Danfoss RA/RAV/RAVL valves included in delivery.
•Remove connects on the
plastic adapter before using
one of the included adapters.
•Use supplied screw and nut.
•Insert pin on valve stem.
6
Siemens
A6V13722083_de--_a
Smart Infrastructure
2022-12-12
Product documentation
Title
Contents
Document ID
Connected Home Radiator Actuator
ZigBee SSA911.02ZB
Data sheet: Product description
A6V13722083
Quick guide Connected Home
Radiator Actuator ZigBee
SSA911.02ZB
Quick guide for mounting, commissioning, and
operation SSA911.02ZB
A5W00293080A
Connected Home Hub GTW100ZB
Data sheet: Product description
A6V12640776
Quick guide Connected Home Hub
GTW100ZB
Quick guide for mounting, commissioning, and
operation SSA911.02ZB
A6V12694180
Connected Home Receiver
RCR110.2ZB
Data sheet: Product description
A6V12680327
Quick guide Connected Home
Receiver RCR110.2ZB
Quick guide for mounting, commissioning, and
operation RCR110.2ZB
A6V11562443
Related documents such as environmental declarations, CE declarations, etc., can also be
downloaded at:
www.siemens.com/bt/download
Notes
Safety
CAUTION
National safety regulations
Failure to comply with national safety regulations may result in personal injury and property
damage.
●Observe national provisions and comply with the appropriate safety regulations.
WARNUNG
Burns from hot surface
The screw nut that fastens the actuator to the radiator valve can become hot. Risk of burns
from touching the screw nut.
When servicing the actuator:
●Switch off the radiator and allow it to cool down.
7
Siemens
A6V13722083_de--_a
Smart Infrastructure
2022-12-12
WARNUNG
Explosion due to fire or short circuit, even with empty batteries
Risk of injury due to flying parts
●Do not expose batteries to water.
●Do not recharge batteries.
●Do not damage or disassemble batteries.
●Do not expose batteries to temperatures over 85 °C.
WARNUNG
Leakage of electrolyte
Severe burns
●Wear protective gloves to handle damaged batteries.
●In case of contact with electrolyte, rinse eyes immediately with plenty of water. Consult
a doctor.
Observe the following:
●Correct polarity (+/-).
●Use new batteries and inspect for damage.
●Do not mix old and new batteries.
Store, transport and dispose of the batteries in compliance with local requirements,
regulations, and laws. Also observe the instructions of the battery manufacturer.
Switching off the device or loss of communication to the radiator valve actuator may result
in an “undefined state” and quickly drain the batteries.
Do not switch off Connected Home Hub and use a repeater as need to ensure proper
communications.
Mounting SSA911.02ZB is mounted on the radiator valve. There are no preferred mounting positions;
actuator SSA911.02ZB can be operated in all mounting positions. The display must be
clearly visible and the buttons easy to access.
WARNUNG
Falling objects
Overhead installation may result in injury from falling objects.
●Do not install the actuator more than 2 m above ground
●Firmly hand tighten the screw nut clockwise to attach the actuator to the valve or
adapter.
8
Siemens
A6V13722083_de--_a
Smart Infrastructure
2022-12-12
Removal
●Delete the device from the Siemens Connected Home App.
●Press the Reset button in the battery compartment for ca. 10 seconds.
●The LCD displays “PA” and counts up to 10.
●Release the Reset button after 10 seconds.
➔The LCD display turns off and the valve stem goes to the mounting position.
●Turn the screw nut counterclockwise and remove from the radiator valve actuator.
Commissioning
●Install the Connect Home mobile app.
–The app provides step-by-step commissioning instructions.
●Install and commission the Connected Home Hub GTW100ZB (see quick guide
A6V12694180).
●Optional: Install and commission the Connected Home Receiver Hub CR110.02ZB (see
quick guide A6V11562443).
●Install and commission the Connected Home Radiator valve actuator SSA911.02ZB (see
quick guide A5W00293080A).
9
Siemens
A6V13722083_de--_a
Smart Infrastructure
2022-12-12
Operation
HMI
The interface consists of an LCD display and two touch
elements.
Lower temperature
Increase temperature
Buttons
Press once
Lower room temperature by 0.5 ℃.
Press and hold
Immediately lowers room temperature by 0.5 ℃,
followed by another 0.5 ℃every 0.5 s the button
is held or until the lowest temperature is reached.
If the settings is less than 8 °C, the LCD displays
“—” and control is switched off.
Press once
Increases room temperature by 0.5 ℃.
Press and hold
Immediately increases room temperature by 0.5
℃, followed by another 0.5 ℃every 0.5 s the
button is held or until the highest temperature is
reached.
When a temperature higher than 28 °C is set,
"ON" appears on the LCD display. The boost
mode is activated for 5 min.
and
Press and hold together for 3 s
Lock or unlock buttons.
If “Ad”, press together and hold for
3 s
Starts adaptation
Reset button
Battery compartment
Press Reset button in battery
compartment and hold for 10 s
Delete the device list from the Connected Home
app to reset to factory settings.
Reset can be performed after 10 s (LCD indicates
how long to press as of 5 s).
Press and hold for 5 s
The device is deleted from the network.
Press and hold for 3 s
Displays the discovered network (Zigbee Node
ID).
10
Siemens
A6V13722083_de--_a
Smart Infrastructure
2022-12-12
LCD indication
Informs about wireless connection and pairing.
On: Connected to gateway.
Off: Not connected to gateway.
Pairing (inclusion) is active.
●Do not operate the actuators in pairing mode over longer periods; this
quickly drains the batteries.
Perform a factory reset if pairing fails after multiple attempts and then try
again per the documentation.
Remove mode (exclusion) active.
Start adaptation.
On during adaptation.
On if button lock is enabled/disabled.
On if battery capacity drops below 15%.
Change operating mode
Operating mode
OFF mode
Press touch element and hold until the LCD displays “--” and the radiator valve
actuator switches off.
Heating mode
The two touch elements and set the temperature between 8 and 28°C.
If the device is not in heating mode, use the touch elements to change the temperature
between 8 and 28 degrees.
Boost mode
To change the device to boost mode, press and hold touch element until the LCD
displays "ON".
Boost mode switches off automatically after 5 minutes.
Window open
mode
“Window open” activates if the temperature suddenly drops. SSA911.02ZB switches to
OFF mode for 15 minutes.
The Window open function switches off after 15 minutes and the device returns to the
last active mode.
Error codes
Error codes
An error code displays on the SSA911.02ZB in the event of a malfunction or communication
error with Connected Home Hub.
Press the plus or minus button to clear error codes.
11
Siemens
A6V13722083_de--_a
Smart Infrastructure
2022-12-12
Maintenance The SSA911.02ZB is maintenance-free.
Disposal
The device is considered an electronic device for disposal in terms of the
European Directive and may not be disposed of as domestic waste.
●Use only designated channels for disposing the devices.
●Comply with all local and currently applicable laws and regulations.
●Dispose of empty batteries in designated collection points.
Warranty Technical data on specific applications are valid only together with Siemens products listed
under "Equipment combinations". Siemens rejects any and all warranties in the event that
third-party products are used.
Code
Error
Cause / measures
Not connecting
●The device does not pair with Siemens Connected Hub
For example, the device is out of range or the gateway is
switched off.
Pairing failed
●Device is not in pairing mode.
●Device is out of range.
●Do not leave the actuator in “Er” mode over
longer periods; this quickly empty the batteries.
●If error cannot be solved immediately, remove
batteries and re-insert only when starting the
pairing process again.
●Perform a factory reset if pairing fails after
multiple attempts and then try again per the
documentation.
No valve detected
●Is the valve correctly mounted on the radiator.
●Use the correct adapter.
Closing point not
recognized
Valve cannot move
●Check that the valve stem is not stuck.
12
Siemens
A6V13722083_de--_a
Smart Infrastructure
2022-12-12
Directive on Radio Equipment
The device uses a harmonized frequency in Europe and also meets the requirements under
the Directive on Radio Equipment (2014/ 53/EU, previously 1999/5/EG).
Cyber security disclaimer
Siemens provides a portfolio of products, solutions, systems and services that includes
security functions that support the secure operation of plants, systems, machines and
networks. In the field of Building Technologies, this includes building automation and control,
fire safety, security management as well as physical security systems.
In order to protect plants, systems, machines and networks against cyber threats, it is
necessary to implement –and continuously maintain –a holistic, state-of-the-art security
concept. Siemens’ portfolio only forms one element of such a concept.
You are responsible for preventing unauthorized access to your plants, systems, machines
and networks. which should only be connected to an enterprise network or the Internet if and
to the extent such a connection is necessary and only when appropriate security measures
(e.g. firewalls and/or network segmentation) are in place. In addition, Siemens’ guidance on
appropriate security measures should be taken into account. For additional information,
please contact your Siemens sales representative or visit
https://www.siemens.com/global/de/home/unternehmen/themenfelder/zukunft-der-
industrie/industrial-security.html.
Siemens’ portfolio undergoes continuous development to make it more secure. Siemens
strongly recommends that updates are applied as soon as they are available and that the
latest versions are used. Use of versions that are no longer supported, and failure to apply
the latest updates may increase your exposure to cyber threats. Siemens strongly
recommends complying with security advisories on the latest security threats, patches and
other related measures, published, among others, under
https://www.siemens.com/cert/de/cert-security-advisories.htm
Technical data
Power supply
Battery type
2 x alkaline batteries LR6 (AA); 1.5 V.
Battery life
ca. 2 years
Radio communication
Frequency range
2.4…2.4385 GHz
Transmitter power
<8 dBm
Area
≤ 30 m, depending on application and building
Protocol
ZigBee
13
Siemens
A6V13722083_de--_a
Smart Infrastructure
2022-12-12
Actuator
Stroke
5 mm
Positioning force
Typical
90 N
Noise level
EN ISO 3741
< 30 dBA
Integrated temperature sensor
Measuring range
0…50 °C
internal controller
Type
PI
Adjustable temperature range
8…28 °C
Degree of protection
Protection class
Class III per IEC 60730-1
Housing type
IP 20 1) per IEC 60529
Degree of pollution
Class 2 per IEC 60730
Environmental conditions
Operation
Temperature
-1…54 °C
Humidity (non-condensing)
5…85% r.h. ± 20 %
Transportation
Temperature
-25...70 °C
Humidity
95 % r.H. ± 20 %
Storage
Temperature
-5...50 °C
Humidity
5…95% r.h. ± 20 %
Permissible temperature of medium in the connected
valve
1…70 °C
Directives and standards
Product standard
IEC 60730-1
Electromagnetic compatibility
For residential, commercial, and industrial environments
EU conformity (CE)
A5W00090263A 2)
UKCA
A5W00206069A
EAC compliance
Eurasian conformity for SSA911.02ZB
14
Siemens
A6V13722083_de--_a
Smart Infrastructure
2022-12-12
Environmental compatibility
Environmental Declaration A5W00285172A 2) contains data on environmental-compatible product design and
assessment (RoHS compliance, compositions, packaging, environmental benefits and disposal).
Material and dimensions
Display
LCD
Housing
Material
Plastic, light ASA+PC
Color
White NCS S 052-G
Thread
M30x1,5
W x H x D
See Dimensions [▶15]
Weight
1)
Fully mounted
2)
Documents available at http://www.siemens.com/bt/download
15
Siemens
A6V13722083_de--_a
Smart Infrastructure
2022-12-12
Dimensions
Dimensions in mm
[kg]
Including batteries
0.16
Revision numbers
Type
Valid from rev. no.
SSA911.02ZB
SS5181-A105
..01
Published by
Siemens Switzerland Ltd
Building Technologies Division
International Headquarters
Theilerstrasse 1a
CH-6300 Zug
+41 58 724 2424
www.siemens.com/buildingtechnologies
© Siemens Switzerland Ltd, 2021
Subject to change
Document ID
A6V13722083_de--_a
Edition
2022-12-12

Other Siemens Controllers manuals

Siemens SIMATIC S5 User manual

Siemens

Siemens SIMATIC S5 User manual

Siemens SIMATIC 500 User manual

Siemens

Siemens SIMATIC 500 User manual

Siemens Simatic S7-1500 User guide

Siemens

Siemens Simatic S7-1500 User guide

Siemens GMA 9E Series User manual

Siemens

Siemens GMA 9E Series User manual

Siemens Powermite 599 MT Series Owner's manual

Siemens

Siemens Powermite 599 MT Series Owner's manual

Siemens SIPART DR21 User manual

Siemens

Siemens SIPART DR21 User manual

Siemens SIMOTION C230-2 User manual

Siemens

Siemens SIMOTION C230-2 User manual

Siemens OpenAir GDB181.1E/KN User manual

Siemens

Siemens OpenAir GDB181.1E/KN User manual

Siemens 7SR224 Operating and installation instructions

Siemens

Siemens 7SR224 Operating and installation instructions

Siemens SIMATIC S5-100U User guide

Siemens

Siemens SIMATIC S5-100U User guide

Siemens Simatic S7-300 User manual

Siemens

Siemens Simatic S7-300 User manual

Siemens Simatic S7-1500 User manual

Siemens

Siemens Simatic S7-1500 User manual

Siemens GEB 1 Series User manual

Siemens

Siemens GEB 1 Series User manual

Siemens SSC31 User manual

Siemens

Siemens SSC31 User manual

Siemens SQL36E65 User manual

Siemens

Siemens SQL36E65 User manual

Siemens Albatros2 RVA78.690 User manual

Siemens

Siemens Albatros2 RVA78.690 User manual

Siemens SIMATIC S5-115U User manual

Siemens

Siemens SIMATIC S5-115U User manual

Siemens Simatic S7-300 User manual

Siemens

Siemens Simatic S7-300 User manual

Siemens SINUMERIK 840D sl User manual

Siemens

Siemens SINUMERIK 840D sl User manual

Siemens RDF20U Owner's manual

Siemens

Siemens RDF20U Owner's manual

Siemens Simatic S7-300 User manual

Siemens

Siemens Simatic S7-300 User manual

Siemens instabus JB520C23 User manual

Siemens

Siemens instabus JB520C23 User manual

Siemens SIRIUS MCU 3RK4353-3.R58-0BA0 User manual

Siemens

Siemens SIRIUS MCU 3RK4353-3.R58-0BA0 User manual

Siemens Stratos Outstation User manual

Siemens

Siemens Stratos Outstation User manual

Popular Controllers manuals by other brands

Eaton CAAE-01/01 Instruction leaflet

Eaton

Eaton CAAE-01/01 Instruction leaflet

iNels SA3-02M Quick start manual

iNels

iNels SA3-02M Quick start manual

Allen-Bradley Studio 5000 Logix Emulate Programming manual

Allen-Bradley

Allen-Bradley Studio 5000 Logix Emulate Programming manual

Omron NJ501-1300 user manual

Omron

Omron NJ501-1300 user manual

Beta Layout Reflow instruction manual

Beta Layout

Beta Layout Reflow instruction manual

Concoa 601 Series Installation and operation instructions

Concoa

Concoa 601 Series Installation and operation instructions

Skene Design Photon Blaster Installation and instruction manual

Skene Design

Skene Design Photon Blaster Installation and instruction manual

Mitel MiVOICE BUSINESS Installation and administration guide

Mitel

Mitel MiVOICE BUSINESS Installation and administration guide

MicroStep Start Shaphon SH-HC31 manual

MicroStep

MicroStep Start Shaphon SH-HC31 manual

Weil-McLain BCP-3 Installation & operating instructions

Weil-McLain

Weil-McLain BCP-3 Installation & operating instructions

schmersal AES 1135 Operating	 instruction

schmersal

schmersal AES 1135 Operating instruction

Linear Technology Analog Devices LTM4676A Demo Manual

Linear Technology

Linear Technology Analog Devices LTM4676A Demo Manual

Linear ANALOG DEVICES LTC7106 Demo Manual

Linear

Linear ANALOG DEVICES LTC7106 Demo Manual

Sealey SGA40 instructions

Sealey

Sealey SGA40 instructions

Prolon C1000 Series Hardware guide

Prolon

Prolon C1000 Series Hardware guide

Midi Solutions Breath Controller operating instructions

Midi Solutions

Midi Solutions Breath Controller operating instructions

MICRO-AIR EasyStart 364 installation manual

MICRO-AIR

MICRO-AIR EasyStart 364 installation manual

Syntec S08-SMD-33B Series installation instructions

Syntec

Syntec S08-SMD-33B Series installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.