Thank you for purchasing our smoke alarm!
Please read these instrucons carefully and store them in a safe place during
the enre lifeme of the product.
Product descripon and intended use
This is a smoke alarm (delivered with baery) with an opcal sensor for
installaon in residenal buildings, apartments and rooms with residenal-
like use. Smoke alarms are designed to provide an early warning of fire smoke
and fires to persons present, so that these persons can react appropriately to
the hazardous event. Always consult local regulaons for smoke alarms.
Product specificaons
Detecon method: O pcal
Power supply : Sealed baery (3 V DC)
Baery lifeme : 10 years
Alarm volume : > 85 dB (A) at 3 meters
Alarm sensivity : 0,094 - 0,149 dB/m
Monitored area : max. 40 m²
Operang temperature : 0 °C - 40 °C
Operang humidity : < 93 %
Date of replacement : See product label
Individual alarm indicator : Yes
Alarm silence facility : Yes | Hush me: 5-15 minutes
Low baery warning : Yes
Low baery silence facility : Yes | Hush me : 10 hours
Installaon in leisure
accommodaon vehicles : Yes
Mounng locaon : Ceiling
Interconnectable : No
Warnings
•To prevent injury, this apparatus must be securely aached to the ceiling in
accordance with the installaon instrucons.
•Baeries should not be exposed to excessive heat such as sunshine, fire or
the like.
•Do not paint or cover the smoke alarm.
Where to install a smoke alarm
Smoke alarms must be installed in such a way that they can be reached
unhindered by the fire smoke so that fires can be reliably detected during the
development phase.
•Install at least in sleeping areas (especially children's rooms).
•Install at least in escape routes.
•In the middle of the ceiling of a room.
•At least 50 cm away from the wall and other objects.
•Maximum installaon height of 6 meter.
Where to install a smoke alarm in rooms
with special geometries
•Corridors with a maximum width of 3 m: Max. 15 m between 2 smoke
alarms. Max. 7,5 m to the front side of the gallery and smoke alarms
at edges/crossings of corridors.
•Rooms with sloping ceilings:
- If the ceiling inclinaon is > 20° to the horizontal: Smoke alarms must be
installed at least 0.5 m and at most 1 m from the ceiling top.
- Paral roof slopes: If the flat ceiling is ≤ 1 m wide, consider as ceiling
inclinaon is of > 20°. If the flat ceiling is >1 m wide,consider as flat
ceiling.
•Rooms with subdivided ceilings:
- Height of the subdivisions is ≤ 0.2 m: Beams without consideraon:
smoke alarm may be installed on the beams as well as on the ceiling.
- Height of subdivisions is > 0.2 m and if one of the ceiling panels > 36 m2:
a smoke alarm device should be installed in this ceiling panel and
addionally a smoke alarm device in the room, preferably in the middle
of the other ceiling panel
- Height of subdivisions > 0.2 m and area of ceiling panels ≤ 36 m²:
Individual ceiling panels are without consideraon. A smoke alarm must
be installed in a ceiling panel or on the joist, preferably in the middle of
the room.
Where not to install a smoke alarm
•In an environment with a high risk of draught (e.g. close to air condioning,
fans and venlaon outlets). The movement of air can impair the
penetraon of fire smoke into the smoke alarm.
•Areas where combusons regularly occurs, such as kitchens.
•Areas with high humidity such as bathrooms, or close to devices such as
dish washers or washing machines.
Acvaon
Before commissioning the smoke alarm, it is important to acvate it and test
it for correct operaon.
•Place the mounng plate on the smoke alarm and secure it by turning it
clockwise. When it’s properly ghtened, the smoke alarm is acvated by
the acvaon switch and generates a loud beep.
•Test the correct acvaon of your smoke alarm by pressing the test buon.
If no sound is generated, the smoke alarm is not acvated properly and
should not be used!
For a reliable test, press test buon for around 10 seconds, unl two
sequences of 3 beeps are generated, and release.
•It is recommended to write the replacement date (10 years) on the label, in
a calendar or in an easily verifiable place.
Mounng
•Remove the mounng plate from the smoke alarm.
•Place the mounng plate on the desired installaon locaon and mark
where the holes should be drilled.
•Drill two holes with a diameter of 5 millimetres.
•Push the plasc plugs into the holes.
•Insert the screws into the mounng plate, and ghten them firmly into the
plugs.
•Place the smoke alarm on the mounng bracket and secure it by turning it
clockwise.
•When it's properly ghtened, the smoke alarm generates a beep.
•Test the correct operaon of your smoke alarm by pressing the test buon.
If no sound is generated, the smoke alarm is not funconing properly and
should not be used!
Alarm silence facility
When the smoke alarm has detected smoke and turns into the alarm mode,
you can mute the alarm for a minimum of 5 minutes and a maximum 15
minutes by pressing the test buon. Aer that, the smoke alarm
automacally resets and returns into the normal operaon mode. If there are
sll parcles of combuson in the air, the smoke alarm will turn into the alarm
mode again. WARNING: Before using the alarm silence facility, always idenfy
the cause of the alarm and make sure that the circumstances are safe.
Ceiling
Mounng plateMounng plateMounng plate
Hobby room
Boiler room
Kitchen
Children’s roomBedroom
Ac
Escape
Escape
Escape
Livingroom
Opmal Restricted
Test buon
Sound output
LED indicator
Acvaon switchAcvaon switchAcvaon switch