Soyal AR-721U User manual

Soyal AR721U661U721K hardware operation guide
Revision: V1
Date released: 1 Nov 2006
UM_Soyal721KP721U661UV1
SOYAL
Access Control System
1
Table of Contents
1. Main Feature ------------------------------------------ 2
2. AR-721U Installation ------------------------------------------3
2.1Steps
2.2Installation Notice
2.3Terminal Cable ------------------------------------------4
2.4 PCB board ------------------------------------------5
2.4.1 No waterproof
2.4.2 Waterproof
2.5 Installation diagram -------------------------------------------6
2.5.1 AR-721U & AR-721H
2.5.2 AR-721U & AR-727H -----------------------------------------7
2.5.3 AR-721U & AR-821EF ---------------------------------------- 8
2.5.4 AR-721U & AR-829E -----------------------------------------9
3. AR-721K Installation ---------------------------------------10
3.1Steps
3.2Installation Notice
3.3Terminal Cable ------------------------------------------11
3.4PCB board
3.5Installation diagram ----------------------------------------12
3.5.1 AR-721K & AR-721H
3.5.2 AR-721K & AR-727H -----------------------------------------13
3.5.3 AR-721K & AR-821EF ----------------------------------------14
3.5.4 AR-721K & AR-829E ---------------------------------------- 15
4. AR-661U Installation --------------------------------------- 16
4.1Installation Notice
4.2Terminal Cable
4.3Installation diagram ----------------------------------------17
4.3.1 AR-661U & AR-721H
4.3.2 AR-661U & AR-727H ----------------------------------------18
4.3.3 AR-661U & AR-821EF ----------------------------------------19
4.3.4 AR-661U & AR-829E -----------------------------------------20
4.4The standalone controller do anti-pass-back with 2 pcs of AR-661U ---------21
4.5Testing table of AR-661U Reading Range depends on tags --------
23
5 Troubleshooting ----------------------------------------24
6 Return of Products / Warranty
2
1. Main Features
Easily integrated with soyal or other access control systems.
Programmable various outputs formats Wiegand , magstripe or serial.
Built-in watchdog to prevent the system from halting
A bi-color LED indicator and a beep sound.
Item AR-721U AR-721K AR-661U
RF Frequency 125KHz 125KHz / 13.56MHz
125KHz
Power
Requirement 9-16VDC 12-18VDC
125KHz 80mAPower
Consumption 50mA 13.56MHz
0.72W 350 mA
Communication
Interface WG 26 / 34, ABA-II, ASYNC, OMRON
Baud Rate 9600 bps (N, 8, 1)
Environment -20°C to +75°C
Proximity
Reading Range 3-8cm 10-18cm (125K) /
3-8cm (13.56M) 33-60cm
Indicator A bi-color LED and a
beeper A bi-color LED and
a beeper Three LED and a
beeper
Keypad - Yes -
Waterproof Option - Yes
Color Dark Pearl Gray / Silver Dark Pearl Gray
Dimensions
(mm) 81(H)*43(W)*18(D) 111(H)*77(W)*26(D)
228(H)*228(W)*38(D)
Weight (g) 40±5 90±10 1,000±50
Housing
Material ABS
3
2. AR-721U Installation
2.1 Steps
1.Use the screwdriver to screw the mounting plate on the wall.
2.Pull cable ends through the access hole in the mounting plate.AR-721U must be
connected before power is applied to the single door controller.
3.Attach the AR-721U to the mounting plate.
4.Apply power. The red LED will flash once and the beeper will sound.
2.2 Installation Notice
1. AR-721U is narrow enough to mount to most mullions and door frames.
2. Single door controller locate inside the secure area for use as an exit controller, the
auxiliary reader locate exterior wall for use as an entrance reader, but not directly
behind single door controller. For best reading distance, offset the single door
controller and auxiliary reader by about 50 cm above and 12 m below (suggestion
value).
3. Normally, AR-721U will read a Card / Key Tag at up to 8 cm. However, when
AR-721U reader is mounted directly on a metal surface, the reading distance
decreases slightly. To reduce this effect, install wood or plastic between the
mounting surface and mounting plate, this will restore most of the reading distance.

4
2.3 Terminal Cable
Table 1 - Color Coding
Wire Application Wire Color Description
1 Red DC Power 12VPower
2 Black DC Power 0V
3 Yellow LED Red Input ( Low Bright)LED
4 Brown LED Green Input ( Low Bright)
5 Blue Wiegand DAT:1Wiegand
6 Green Wiegand DAT:0
Beeper 7 Purple Beeper Input ( Low Sound )
8 White Card Present
Beeper 9 Gray Beeper Output
Output Selection
Output WG26 WG34 RS-232 Magnetic ( ABA )
34/26 Open Close Open Close
ABA Open Open Close Close
AR-721U RS-232 Format: ( 9600,N, 8, 1 SOYAL Format )
DAT:0: TTL Inverted Serial Output.
( Can connect to PC comm port )
DAT:1:TTL Serial Output.
( connect to PC comm. port through RS-232 invert driver )
5
2.4 PCB board
2.4.1 No waterproof
2.4.2 Waterproof
ABA 34126
Buzzer
721U PCB
Output Format
WG 26
WG 34
ABA
II
RS-232
ABA 34126
34126ABA
34126ABA
34126ABA
(Default)
Output Format
AR-721U
Buzzer
Cut for WG26 bit
Connect for WG34 bit (Default)
6
2.5 Installation diagram
2.5.1 AR-721U & AR-721H
BA
CN4
CN2
P2
7AC2
Red
CN2
1
DAT:11
Blue Blue
AR-721U
Color
Pin
A
Function
Pin
B
Green
Pink
Brown
Yellow
5
3
2
4
DAT:0
Beeper input
Red LED
Green LED
Purple
Green
Brown
Yellow
-GND
+ 12VDC
SOYAL
12VDC 500mA
Power Supply
RELAY
CN1
P1
CN1
Black
Red
721H5DS
The installation of 721H and auxiliary reader 721U
CN3
Black
7
2.5.2 AR-721U & AR-727H
Green
Blue
Yellow
Purple
Brown
The installation of 727H and auxiliary readers
721U
12VDC 2A
Power Supply
Red(+ 12VDC)
Black
Red
1
721K
Red
Black
CN1
1
~
Yellow
Brown
CN2
Green
Pink
Blue
661U
Black(-GND)
Brown
Yellow
Green
Pink
Blue
727H
CN3
CN1

8
2.5.3 AR-721U & AR-821EF
CN2
P2
A
Red(+ 12VDC)
Black(-GND)
Red(+ 12VDC)
Black(-GND)
1
B
TP1
821EF
Red LED
Yellow
7
Yellow
CN7
Black(-GND)
P1
CN1
CN3 CN2
Red(+ 12VDC)
3
Pin
A
5
4
6
Blue Blue
Color
B
Pin
Pink
Green
Brown Purple
Green
Brown
CN1
+ 3V
DAT:1
Function
DAT:0
Beeper Input
Green LED
~
reader 721U
Power Supply
12VDC 2A
The installation of 821EF and auxiliary
9
2.5.4 AR-721U & AR-829E
Yellow
Purple
Brown
Blue
Green
The installation of 829E and auxiliary readers
721U
12VDC 2A
Power Supply
Red(+ 12VDC)
Black
Red
1
721K
Red
Black
CN1
1
~
Yellow
Brown
CN2
Green
Pink
Blue
661U
Black(-GND)
Brown
Yellow
Green
Pink
Blue
829E
CN1
CN2
10
3. AR-721K Installation
3.1 Steps
1.Use the screwdriver to screw the mounting plate on the wall.
2.Pull cable ends through the access hole in the mounting plate.
AR-721K must be connected before power is applied to the single door controller.
3.Connect plug P1 to socket CN1 on the AR-721K circuit board.
Connect plug P2 to socket CN2 on theAR-721K circuit board.
Connect plug P3 to socket CN3 on theAR-721K circuit board.
4.Attach the AR-721K to the mounting plate and install screw
(supplied) into the hole at the bottom with theAllen wrench (supplied).
5.Apply power. The red LED will flash once and the beeper will sound. Refer to
beginning of this manual for programming.
3.2 Installation Notice
1.Single door controller locate inside the secure area for use as an exit controller, the
auxiliary reader locate exterior wall for use as an entrance reader, but not directly
behind single door controller. For best reading distance, offset the single door
controller and auxiliary reader by about 50 cm above and 12 m below (suggestion
value).
2.Normally, single door controller will read a Card / Key Tag at up to 15 cm. However,
when single door controller or optional auxiliary reader is mounted directly on a metal
surface, the reading distance decreases slightly. To reduce this effect, install wood or
plastic between the mounting surface and mounting plate, this will restore most of the
reading distance.
AR-721K can cover standard electrical boxes.
11
3.3 Terminal Cable
3.4 PCB board
Table 2 - Connector P2 Color Coding (Wiegand Read Head )
Wire Application Wire Color Description
1 Thin Blue Wiegand DAT:1 Input
ABA Format:Clock
2 Thin Green Wiegand DAT:0 Input
ABA Format:Data
Wiegand
ABA
3 Orange ABA Format Card Present
4 No Connection
Beeper 5 Pink Beeper Input ( Low Sound )
6 Brown LED Green Input ( Low Bright)
LED 7 Yellow LED Red Input ( Low Bright)
Table 1 - Connector P1 Color Coding
Wire Application Wire Color Description
1 Thick Red DC Power 12VPower
2 Thick Black DC Power 0V
Table 3 - Connector P3 Color Coding (Tamper Switch )
Wire Application Wire Color Description
1 Red N.C.
2 Orange COM
Tamper Switch
3 Yellow N.O.
SOYAL Format
EM Format
BIT(26/34)
ABA 10
WG 34
Output Format
Buzzer
1FF9
721K
WG 34
WG 26
WG J2
J3
J2
WG
J3
(Default)
(Default)
J2
J2
WG
WG RST
RST
RST
RST
J2
J1 J3WG

12
Mifare Terminal Cable
Table 1 - Connector P1 Color Coding
Wire Application Wire Color Description
1 Blue Whithe NO Connection
2 Purple White
NO Connection
3 White NO Connection
4 Orange SET2Output Format 5 Purple SET1
6 Grey NO
7 Thick Red DC 12VPower 8 Thick Black DC 0V
Table 2 - Connector P2 Color Coding
Wire Application Wire Color Description
1 Thin Blue Wiegand DAT : 1 OutputWiegand 2 Thin Green Wiegand DAT : 0 Output
Beeper 3 Pink Beeper Input (Input Low)
4 Brown LED Green Input (Input Low)LED 5 Yellow LED Red Input (Input Low)
Table 3 - Connector P3 Color Coding
Wire Application Wire Color Description
1 Red N.C.
2 Orange COM
Tamper Switch
3 Yellow N.O.
Table5- Output Selection
Output SET1 SET2 Note
WG-26 Open Open Hex
WG-34 Open Close Hex
ABA-10 Close Open BCD 10
ABA-5-5 Close Close BCD 5:5
Table 4 - Connector P4 Color Coding
Wire Application Wire Color Description
1 Thick Blue RS-485(B-)Networking
Module 2 Thick Green
RS-485(A+)
13
3.5 Installation diagram
3.5.1 AR-721K & AR-721H
CN1
CN1
P 1
Gray
Black
Red
-GND
+ 12VDC
+ 12VDC
-GND
12VDC 2A
Power Supply
1
12VDC 500mA
Power Supply
7AC2
CN4CN2
721K
CN3
SOYAL
-GND
+ 12VDC
CN1
P 1
CN1
P 2
CN2
Black
Red
BlueWhite
(N.O)
White(
COM)
CN4CN2
721H5DS
7AC2
+ 12VDC
CN3
COM
N.O
ALM
N.C
SOYAL
+ 12VDC
-GND
RELAY
Yellow(LED)
Brown(LED)
Green(DAT:0)
Blue(DAT:1)
Pink (ALM)
The installation of 721H and auxiliary reader 721K
P 2
~
CN2
14
3.5.2 AR-721K & AR-727H
Green
Blue
Yellow
Purple
Brown
The installation of 727H and auxiliary readers
721U
12VDC 2A
Power Supply
Red(+ 12VDC)
Black
Red
1
721K
Red
Black
CN1
1
~
Yellow
Brown
CN2
Green
Pink
Blue
661U
Black(-GND)
Brown
Yellow
Green
Pink
Blue
727H
CN3
CN1
15
3.5.3 AR-721K & AR-821EF
Black(-GND)
Red(+ 12VDC)
CN1
P1
CN2
P2
A
Black(-GND)
Red(+ 12VDC)
P2
CN2
~
821EF
1
~
CN2 CN4
B
27BF
721K
1
+ 3V
DAT:024
Green
3
CN1
CN3
CN7
CN2
Color
Blue
Pin
1
B
Function
DAT:1
6
5
7
Beeper Input
Green LED
Brown
Pink
Yellow
6
5
7Red LED
CN3
The installation of 821EF and auxiliary
TP1
APin
Red(+ 12VDC)
reader 721K
Black(-GND)
Power Supply
12VDC 2A
CN1
CN1
P1
SOYAL

16
3.5.4 AR-721K & AR-829E
Yellow
Purple
Brown
Blue
Green
The installation of 829E and auxiliary readers
721U
12VDC 2A
Power Supply
Red(+ 12VDC)
Black
Red
1
721K
Red
Black
CN1
1
~
Yellow
Brown
CN2
Green
Pink
Blue
661U
Black(-GND)
Brown
Yellow
Green
Pink
Blue
829E
CN1
CN2
17
3.5.5 721K
1356
& AR-721H
18
4. AR-661U Installation
4.1 Installation Notice
Minimum distance betweenAR-661U & other proximity Reader ( 200cm )
4.2 Terminal Cable
Table - Color Coding
Wire Application Wire Color Description Remark
1 Red 12-18VDC regulatedPower
2 Black Power Ground
3 Blue Wiegand DAT:1 Open collectedWiegand
4 Green Wiegand DAT:0 Open collected
5 White Card Present
Beeper 6 Purple Beeper Output
7 Yellow SEL1Output Selection
8 Brown SEL2
Output Selection
Output WG26 WG34 RS-232 WG34 + 4
SEL1 Open Close to GND Open Close to GND
SEL2 Open Open Close to GND Close to GND
Note:
WG34+4: Follow 0101 after WG34 data stream for reader identification.
See Also:AR-721H do anti-pass-back with 2 pcs of AR-661U.
R>200CM
5
2
8
0
1
7
*
4
3
9
#
6
19
4.3 Installation diagram
4.3.1 AR-661U & AR-721H
4.2.1 AR-661U & AR-727H
Color
Green
1
Blue
A
Pin
2 DAT:0
DAT:1
Function
Blue
Pin
B
Green
721H5DS
7AC2
The installation of 721H and auxiliary reader 661U
P2
CN2
A
B
CN4
~
Red
Black
-GND
1
CN2
SOYAL
CN3
P1
CN1
RELAY
CN1
Black
12VDC 500mA
Power Supply
+ 12VDC Red

20
4.3.2 AR-661U & AR-727H
Green
Blue
Yellow
Purple
Brown
The installation of 727H and auxiliary readers
721U
12VDC 2A
Power Supply
Red(+ 12VDC)
Black
Red
1
721K
Red
Black
CN1
1
~
Yellow
Brown
CN2
Green
Pink
Blue
661U
Black(-GND)
Brown
Yellow
Green
Pink
Blue
727H
CN3
CN1
21
4.3.3 AR-661U & AR-821EF
Function
DAT:1
Blue
3
Blue
Black(-GND)
Red(+ 12VDC)
CN1
P1
12VDC 2A
CN2
A
1
821EF
CN2
+ 3V
~
B
reader 661U
12VDC 2A
Power Supply
Black(-GND)
Red(+ 12VDC)
A
CN3 CN1
CN7
B
Color
Pin Pin
GreenGreen
4 DAT:0
Power Supply
The installation of 821EF and auxiliary
P2
TP1
22
4.3.4 AR-661U & AR-829E
Yellow
Purple
Brown
Blue
Green
The installation of 829E and auxiliary readers
721U
12VDC 2A
Power Supply
Red(+ 12VDC)
Black
Red
1
721K
Red
Black
CN1
1
~
Yellow
Brown
CN2
Green
Pink
Blue
661U
Black(-GND)
Brown
Yellow
Green
Pink
Blue
829E
CN1
CN2
23
4.4 The standalone controller do anti-pass-back with 2 pcs of
AR-661U
Standalone controller includes AR-721H, AR-727H and AR-829E.
And here is AR-721H & 2 pcs AR-661U diagram.
Blue
Green
Yellow
White
Purple
Green
Bule
Black
Red
Output Selection
AR-721H do anti-pass-back with 2 pcs of AR-661U
Black
Red
Black
Bule
Green
Purple
White
Yellow
Red

24
When the distance between 2 pcs 661U is less than 6 meter (suggestion
value), we can use the following ways to solve in order to avoid interference
with each other to result in reading distance decrease.
SYNLGND RF
SYNLGND RF
Output
Slaver
GND
Cable
SYNLRF
AR-661U Partial drawing Master
Two AR-661U Reader WIRING (RF switching)
Single Reader (RF always ON)
25
4.5 Testing table of AR-661U Reading Range depends on tags
Testing circumstances: Voltage 12V/500mA, No other jamming in 5 meters.
Item no. Name Sample
S/N
Testing
Distance
(cm)
Maximum
(cm)
Minimum
(cm)
Average
(cm)
1 35
2 37
AR-701KPC
RW-2
Key-chain
(R/W) 3 38
38 35 36.5
1 56
2 55
AR-2561
TRW
Thick Card
(R/W) 3 60
60 55 57.5
1 40AR-8972 ISO
RW ISO Card 2 42 42 40 41
1 66
2 65
AR-2563 TRL
Long
distance
Card
(Read Only)
3 56
66 56 61
26
5. Troubleshooting
Questions Answer
No appearance 1.Check power, if it is 9 – 18 VDC adaptor?
2.Check if the polarity is correct?
3.The unit should make a beep sound when any key on
the keypad is depressed (AR-721K).
6. Return of Products
If you think that you have a defective unit, please contact the distributor who sold you the
unit. All service and repairs must be done through an authorized distributor.
7. Warranty
SOYAL warrants that the product(s) shall be free from manufacturing defects in
materials and workmanship for a period of fifteen (15) month from the date of delivery
provided that the product was properly installed and used. The foregoing warranty shall
not apply to defects resulting from abuse, misuse, accident, unauthorized alteration or
repair, neglect, acts of God (such as floods, fire, etc.). SOYAL shall, at its option, either
repair or replace product(s) which prove to be defective within the warranty period.
SOYAL will replace any product found to be defective within the first three months of
purchase provided said product was properly installed and used. Distributor agrees to
insure the product or assume the risk of loss or damage in transit to prepay shipping
charges and to use the original shipping container or equivalent. Customers shall seek
assistance from the distributor who sold you product(s). Repaired or replaced product(s)
are warranted for ninety (90) days from the date of repair or replacement, or for the
remainder of the original product’s warranty period, whichever is longer.
Note: Don’t tear a lable such as
AR-661UXXXX
0506-123456
on the PCB board, because it is
SOYAL warranty.
Other manuals for AR-721U
2
This manual suits for next models
2
Table of contents
Other Soyal IP Access Controllers manuals

Soyal
Soyal AR-837-E User manual

Soyal
Soyal AR-821EF User manual

Soyal
Soyal AR-721H User manual

Soyal
Soyal AR-888-PBI User manual

Soyal
Soyal AR-327H User manual

Soyal
Soyal AR-837-E User manual

Soyal
Soyal AR-331-EF User manual

Soyal
Soyal AR-721K User manual

Soyal
Soyal AR-837 E User manual

Soyal
Soyal AR-837-EA-T User manual

Soyal
Soyal AR-723 User manual

Soyal
Soyal AR-321H User manual

Soyal
Soyal AR-837-EL User manual

Soyal
Soyal AR-888U User manual

Soyal
Soyal AR-725E User manual

Soyal
Soyal AR-363-E User manual

Soyal
Soyal AR-723-H User manual

Soyal
Soyal AR-721KP User manual

Soyal
Soyal AR-327 User manual

Soyal
Soyal AR-723 H User manual