Soyal AR-363-E User manual

SOYAL
ACCESS CONTROL SYSTEM
®AR-363-E
V230322
- 1 -
x1
F.
1
CN4 CN5 CN7
CN6 CN3 CN8 CN11
※
f.
A1.
F.
E.
2
4
5
e.
123
456
789
0
3
CN4
CN5
CN7
CN8
CN6
CN3
CN9
CN11
68.3
84
10
25
6.9
10
6.1
6.1
R3.1
R1
R
3.
1
118.3
30
Contents
AR-363-E
1Products 2Terminal Cables 3Tools 3Optional
Use a screwdriver to screw the base F onto the wall.
Attach the water proof gasket to the base F, and pull the cables from
the square hole of the base F, and connect to the body A1.
Assemble the body A1 with the base F.
Screw A1 and F tight with the Allen key and screws (accessories
supplied).
Turn on the power and LED will light and beep will sound.
※ Optional wafer cables for additional purchase for TTL
integration with peripheral devices or oor control.
CN11
Wire Application Wire Color Description
Anti-Tamper
Switch
1Red N.C.
2Orange COM
3Yellow N.O.
CN3Cable:
Wire Application Wire Color Description
Lock Relay 1Blue White (N.O.)DC24V1Amp
2
Purple White
(N.C.)DC24V1Amp
Common-COM-Point
3White (COM)DC24V1Amp
Door Sensor 4Orange Negative Trigger Input
Exit Switch 5Purple Negative Trigger Input
Alarm Relay 6Gray Transistor Output Max. 12V/100mA
(Open Collector Active Low)
Power 7Thick Red DC 12V
8Thick Black DC 0V
CN4Cable:
Connector Table
Notice
1. Tubing: The communication wires and power line should NOT be bound in the same conduit or tubing.
2. Cable selection: Use AWG 22-24 Shielded Twist Pair to avoid star wiring. Use CAT5 for TCP/IP connection.
3. Power supply: Don’t equip reader and lock with the same power supply. The power for reader may be unstable when the lock is activating, that may make the
reader malfunction. The standard installation: Door relay and lock use the same power supply, and reader use independent power supply.
Front View Side view
Flat Head Hex Socket
Screw: M3x8
Ethernet Module Only
Installation Dimension(mm)

SOYAL
ACCESS CONTROL SYSTEM
®AR-363-E
V230322
- 2 -
EXIT
E
12V
GND
P.T.Exit
12V
GND
12V
GND
N.O.
GND
N.O.
COM
PB
12V
GND
CN4
3
4
5
6
7
8
2
1
EXIT
N.C.
COM
PB
12V
GND
N.O.
N.O.
COM
N.C.
V+
V-
CN5
CN5
WG Port
WG Port
Main Port
Main Port CN4
Door Sensor
PB
12V
GND
CN4
3
4
5
6
7
8
2
1
N.O.
COM
PB
12V
GND
CN4
3
2
1
EXIT
N.C.
N.O.
CTL
12V
12V
GND
12V
GND
12V
GND
12V
GND
12V
GND
12V
GND
N.O.
GND
N.C.
COM
4
5
6
7
8
CN5
CN5
WG Port
WG Port
Main Port Main Port
AR-725-E
Wire Application Wire Color Description
Power 1 Red DC 12V Output
Security trigger signal
2Purple Security trigger signal Output
Arming 3 Red White Arming Output
WG mode: WG1 Output
Duress 4 Yellow White Duress Output
WG mode: WG0 Output
CN8Cable:
Wire Application Wire Color Description
1 --- ---
2 --- ---
TCP/IP Output
3
Orange White
Net - TX+
4Orange Net - TX-
5Green White Net - RX+
6Green Net - RX-
7 --- ---
CN7Cable:
Wire Application Wire Color Description
RS-485 for Lift
Controller
1Thick Green RS-485(B-)
2Thick Blue RS-485(A+)
CN6Cable:
Wire Application Wire Color Description
Beeper 1Pink Beeper Output 5V/100mA, Low
LED 2Yellow Red LED Output 5V/20mA, Max
3Brown Green LED Output 5V/20mA, Max
Door Output 4Blue White Transistor Output Max. 12V/100mA
(Open Collector Active Low)
Wiegand 5Thin Green Wiegand DAT: 0 Input
6Thin Blue Wiegand DAT: 1 Input
WG Door Sensor
7Orange Negative Trigger Input
WG Exit Switch 8Purple Negative Trigger Input
CN5Cable:
Wire Application Wire Color Description
TTL Port 1Black DC 0V
2Yellow TX
3White TE
4Orange RX
5Red DC 5V
6 --- ---
Cable: CN11 Optional:
(Request to purchase AR-725L485 additionally)
CN9
※ The Wiring of Enable "Share Door Relay" ( Set up via the parameters
setting Window of 701ServerSQL)
※ The Wiring of Enable "Share Door Relay" ( Set up via the parameters
setting Window of 701ServerSQL)
Controller
POWER
12VDC
POWER
12VDC
Alarm
Relay Outpot Module
Door
Sensor
RTE
POWER
12VDC
POWER
12VDC
Electric
Strike
Connect to Electric Strike Connect to Door Sensor
Connect to Electric Bolt Connect to Magnet Lock
Wiring Diagram
Electric Bolt
AR-1207
Controller Controller
RTE RTE
POWER
12VDC POWER
12VDC
POWER
12VDC POWER
12VDC
Magnet Lock
※The Wiring of Enable "Share Door Relay" ( Set up via the parameters setting Window of 701ServerSQL)

V230322
- 3 -
N.C.
N.O.
COM
CTL
12V
E
12V
GND
P.T.Exit
12V
GND
CN5
CN4
BZ
RLED
GLED
Door Output
WG 0
WG 1
WG-DS
WG-PB
N.C.
EXIT
RTE
1
2
3
5
6
7
8
4
BZ
RLED
GLED
WG 0
WG 1
12V
GND
WG Port
Main Port
E
EXIT
12V
GND
12V
GND
N.O.
12V
GND
CN4
N.C.
N.O.
COM
CTL
12V
GND
PB
AR-721RB
12V
GND
DDR
CN8
3
4
5
6
7
8
2
1
4
1 2 3
1
2
3
4
5
6
7
8
EL
AC
PT
N.O.
COM
PB
V+
V-(GND)
N.C.
N.O.
COM
CTL
V+
EL
AC
PT
N.O.
COM
PB
V+
V-(GND)
N.C.
N.O.
COM
CTL
V+
12V
GND
CN4CN4
CN8
CN5
CN5
BZ
RLED
GLED
Door Output
WG 0
WG 1
DSS
PB
DSS
PB
Duress
ARM
PB
V+
V-(GND)
V+
V-(GND)
1
2
AR-363-EAR-363-E
33 44 55 66 77 88 22 11
11
22
33
44
55
66
77
88
3
4
Illuminated Touch-panel
Access controller
Traditional Electronic Door Lock wiring diagram
adopted with controller power supply
Traditional Electronic Door Lock wiring diagram
adopted with interphone power supply
POWER
DC12~24V
POWER
DC12~24V
POWER
AC18V
AR-821RB AR-821RB
Controller
Traditional
Electronic
Door Lock
Traditional
Electronic
Door Lock
Controller
(Controller power supply) (Controller power supply) (Interphone power supply)
※ This wiring diagram function is required to setup Door Relay Time in 1 sec, please refer to 02 TTT command.
※Using Rule :
Finger : Both 363-E Master mode and 363-E
WG mode must store all the same FP data and
real or visual card number.
Card : Can pass WG message to controller.
1. AR-363-E can be set up as WG26/WG34/
WG64 while the Controller is in WG Mode.
These Controller can also be paired with the
Controller that has WG input function.
2. Networking Setting: Select E Series Controller
Parameter Edit in 701Server,tick up the function
“Ev5 WG out/Hv3 Lift out”
3. Please restart the controller after pressing
“Write to Controller”.
POWER
12VDC
WG Mode Controller Mode
701ServerSQL Parameter Setting701ServerSQL Parameter Setting
Strengthen security with AR-721RB Connect to Reader
,AR-725-E become WG mode
(28 000 )
WG Mode / Controller Mode Setting Method
Controller
Reader
POWER
12VDC
POWER
12VDC
Door
Sensor
Electric Bolt Electric Bolt
※ The Wiring of Disable "Share Door Relay" ( Set up via the parameters
setting Window of 701ServerSQL
RTE
POWER
12VDC
POWER
12VDC
※This wiring method is not eligible for "Share Door Relay" function (set up via parameter
setting of 701ServerSQL). If there is external wiring to Wiegand reader, WG Port must
enabled Digital Relay Output to enable "Share Door Relay" function.
Controller
Electric Bolt
AR-1207

SOYAL
ACCESS CONTROL SYSTEM
®AR-363-E
V230322
- 4 -
[Add 50 consecutive tags] Add 50 new tags with consecutive card number following user address 00050-00150:
Enter program mode → 19 00050 001001 →Successfully added tags of user 50-150
Adding and Deleting Tag
Add New Tags
Add by Presenting Tags (apply to Single Tag or a Batch of Tags)
[Add single tag] Add a new tag for selected user address 100:
Enter program mode → 19 00100 00001 → Present the tag → Successfully added tag of user 100
Add Non-consecutive Tags:
Add Consecutive Tags:
[Add 2 additional tags] Add new tags to the following user address 101-102:
Enter program mode → 19 00101 00001 → Present (User 101) card → Present (User 102) card
→ Successfully added tags of user 101-102
[Add 10 additional tags] Add new tags to the following user address 103-112
Enter program mode → 19 00103 00001 → Present (User 103) card → Present (User 104) card → Present (...) card
→Present (User 111) card →Present (User 112) card →Successfully added tags of user 103-112
※Important Notice: Please remember the last user address being added to make sure the old user data is not being over written
with the new card in the future.
Delete All Tags
Input 123456 (or Master Code) → 29 29
Delete Single Tag or a Batch of Tags (by User Address)
Input 123456 (or Master Code) → 10 SSSSS EEEEE
[e.g.] Delete User Address: 00058
Enter program mode → 10 00058 00058
[e.g.] Delete User Address: 00058~00063
Enter program mode → 10 00058 00063
9
9
9
Tag Information
(125kHz) ※ For Mifare tags, the separator between Site Code & Card Code is comma ",".
SITE CODE
CARD CODE
SITE CODE
CARD CODE
Delete Tags
Changing the Master Code
Access programming mode → 09 PPPPPPRRRRRR [Input the 6-digit new master code twice.]
[e.g.] If want to changing the Master Code= 876112, input 123456 → 09 876112876112
Exiting
Input
Programming
A. Entering and Exiting Programming Mode
Entering
Input 123456 or PPPPPP
[e.g.] The Default Value= 123456, if already changed the Master Code= 876112, input 876112 → Access programming mode
Access programming mode → 00 NNN MMM AAA
[NNN= Node ID: 000~254; MMM=AR-725-E Door NO.:1~255; AAA=WG Reader Door NO.:1~255
B. Changing the Node ID of Reader

SOYAL
ACCESS CONTROL SYSTEM
®AR-363-E
V230322
- 5 -
Enable device
Access programming mode → 20 0 or 1 ??? 0 or 1= Enable target unit
(0=Main Controller Parameter Setting,1=WG Input Port Parameter Setting)
[e.g.] If the AR-363-E set to exit reader, WG Reader set to access reader.
Access programming mode → 20 0 128 → 20 1 192 [Please refer to Compound Command Function List for details.]
Enable/Disable auto open zone
Access programming mode → 20 0 or 1 ??? 0 or 1= Enable target unit
(0=Main Controller Parameter Setting,1=WG Input Port Parameter Setting)
[e.g.] If the AR-363-E set to Enable aut open zone.
Access programming mode → 20 0 004 [Please refer to Compound Command Function List for details.]
[e.g.] User address from 00152 to 00684 enable the anti-pass-back function: 26 00152 00684 0
Enable card user
Access programming mode → 26 SSSSS EEEEE P SSSSS= starting user address; EEEEE= ending user address [P=0 Enable/ P=1 Disable/ P=2 Reset]
Usually, anti-pass-back is commonly applied to parking areas in order to prevent from multi-entry with one card at a time, or somewhere wants to
monitor not only the access but also exit condition.
Door will remain open after ashing one valid card. When the reader is stand-alone, supporting only 16 sets of auto-open zone by device setting.
Auto-open zone can extend up to unlimited sets by Networking. Please refer to paragraph Compound Command Function List below to ensure
command
20 0 or 1 ??? / 24 0 or 1 ??? will not reset the functions that already had been changed.
E. Anti-pass-back
F. Auto Open Access (uncontrolled) Time Zone – Automatically Release Door Lock
C.Setting up the control mode (M4/M8)
D. Setting up the password
Access programming mode → 04 N [N=4/8]
Individual PWD (M4/M8)
Card or PIN: Access programming mode → 12 UUUUU PPPP [e.g. User address: 00001 and PWD: 1234. Input 12 00001 1234 ]
Card and PIN: Access programming mode → 13 UUUUU PPPP [e.g. User address: 00001 and PWD: 1234. Input 13 00001 1234 ]
Mode Support
Networking/
Stand-Alone
Networking/
Stand-Alone
User
Capacity Access Mode
M4
M8
V
V
V
V
V
V
64
64
unlimited
unlimited
32,000
32,000
16,000
(0~15,999)
16,000
(0~15,999)
Event
Capacity
120
Holidays Duress Time
Zone
Lift
Control
Anti-pass-
back
1.Card only
2.Card and PIN (4-8 digit PIN Can be set)
3.Card or User address (5-digit) + Individual PIN
(4-8 digit individual PIN Can be set )
1.Card only
2.Card and PIN (4-8 digit individual PIN Can be set)
3.Card or PIN (4-8 digit individual PIN Can be set)
E. PIN & UID Length setting
Access programming mode → 42 m n 【m=PIN code Length 4~8 Digit;n=UID Length 2~8 Digit】(4 is default value)
Example:42 8 4 【PIN code Length 8 Digit;UID Length 4 Digit】
[e.g.] If the WG Reader set to Enable aut open door without presenting card.
Access programming mode → 24 1 128 [Please refer to Compound Command Function List for details.]
Enable/Disable auto open door without presenting one valid card and Automatically release door lock when auto open time is up
Access programming mode → 24 0 or 1 ??? 0 or 1= Enable target unit(0=Main Controller Parameter Setting,1=WG Input Port Parameter
Setting) [Please refer to Compound Command Function List for details.]
(Note : The modication of controller mode between M4/M8(networking) and M6(standalone) will reset the data, user data will be required to rebuild.)

V230322
- 6 -
Illuminated Touch-panel
Access controller
G. Lift control
Single oor
[e.g.] User address NO. 45 only can reach the elevator to the 24th oor: 27 00045 24
Access programming mode → 27 UUUUU LL
UUUU=User Address LL=Floor number (01~64 oor)
Connect with AR-401-IO-0016R to control oors which the user will be able to access. [BAUD9600]
Set
(G)
Floor
L
8
16
24
32
40
48
56
64
0
1
2
3
4
5
6
7
L
6
14
22
30
38
46
54
62
L
7
15
23
31
39
47
55
63
L
5
13
21
29
37
45
53
61
L
4
12
20
28
36
44
52
60
L
3
11
19
27
35
43
51
59
L
2
10
18
26
34
42
50
58
L
1
9
17
25
33
41
49
57
[e.g.] User address NO. 168 can reach only the 6th and 20th oor:
Access programming mode → 21 00168 0 00100000
→ 21 00168 2 00001000
Multi oors
Access programming mode → 21 UUUUU G LLLLLLLL
[UUUUU=User address G: 8 sets of lift control (Input: 0~7) LLLLLLLL: 8 oors setting (L=0=Disable, L=1=Enable)
H. Setting Up the Arming
[e.g.]AR-725-E (without WG reader), to set second time zone which could be passed only at 9:30am to 4:20pm on Mon, Wed and Fri.
Access programming mode → 08 10 01 09301620 01010100 → setting is completed
Set up auto-open time zone
Access programming mode → 08 MW NN HHMMhhmm 7123456H [M=AR-725-E; W=Reader(0=disable,1=enable); NN: 16 sets of
auto-open zone (NN=00~15); HHMMhhmm=Starting time to ending time; 7123456H= 7 days of week + Holiday (F= 0: disable; 1: enable)]
Arming ModeDisarming Mode
TriggeringAlarm
Condition:
TriggeringAlarm
Condition:
VS abnormaldoor
position
dooropentoo
long
doorisforced
openg
doorisforced
openg
In the security management of access control system, the controller or reader status is divided into Standby Mode or Disarming Mode and Arming
Mode. The conditions for triggering the alarm in these two modes is dierent, as shown in the following comparison:
Alarm conditions:
1. Door is forced open
Application:
1. Door open too long: Door is open longer than door relay time plus door close time.
2. Force open (Opened without a valid user card): Access by force or illegal procedure.
3. Door position abnormal: Arming is enabled and the power is suddenly o then on.
1.Normal Opening
Arming Setting and Alarm Trigger Procedure :
Door Relay TMArming Delay TMEnable Arming Alarm Relay TMDoor Close TM Alarm Delay TM
Enable
Arming Status
Alarm Trigger
Door open
Green Led Flash Quickly Red Led Flash Quickly
Alarm trigger
Green Led Flash
Standby Mode
(Arming is not enable)

SOYAL
ACCESS CONTROL SYSTEM
®AR-363-E
V230322
- 7 -
24
5
3
1
Firmware Upgrade
Get the upgrade software from SOYAL or our distributor and run “UdpUpdater” software
Update the rmware
[Please login the SOYAL web to download the new ISP Firmware.]
1. Input the Target Address and Port
2. [Load F/W] open the documents that have the new ISP Firmware
3. Click the new ISP Firmware and [Open] it
4. Click [Update Device] to start the rmware update
5. Till the screen shown [Firmware Update is Complete]
Execute the software
The software is Login the SOYAL web to downloads
※More Details: Software Manual - UDP UPDATER
Restoring Factory Settings
Reset all device parameters and user card data
Reset User Data &Controller Parameter :
Access programming mode → 29 20
Reset User Data &Controller Parameter (incl. Master Code)
& Reset Parameter Setting- SOR :
Access programming mode → 29 21
Reset IP Setting:
Access programming mode →Press “IP Resent Button” of main board for few seconds. (Reference to picture)
Reset User Data :
Access programming mode → 29 29
Enable all devices: Access programming mode → Enable particular device: Access programming mode →
0 or 1
Disable Arming status:
Standby Mode
Standby Mode
Enter Program Mode
Card only
Card only
Card or Passcode
Card or Passcode
Card and Passcode
Card and Passcode
※ Factory default armingcode is: 1234. 0 or 1=Reader unit (0=Main Controller Parameter Setting,1=WG Input Port Parameter Setting ).
Enable all devices
Induct valid card → Input 4 digit
arming code →
Enable particular device
Induct valid card →Input 4 digit
arming code →0 or 1 or
Disable particular device
Induct valid card →Input 4 digit
arming code →0 or 1 or
Input 5 digit user address → Input 4
digit pass code → → Input 4 digits
arming code → or
0 or 1
Induct valid card →Input 4 digit pass
code →→Input 4 digits arming
code →or
0 or 1
Disable all devices
Induct valid card → Input 4 digit
arming code → 9
Input 5 digit user address → Input 4
digit pass code → → Input 4 digits
arming code → or 0 or 1
9
Induct valid card →Input 4 digit pass
code →→Input 4 digits arming
code →or 0 or 1
9
※ After operation as above, you will hear the long reminder sound,and wait until the
sound disappear then reset the power of the controller,the device will restore factory setting.
2.Abnormal Opening
Enable
Arming Status Alarm Trigger
Green Led Flash Quickly Red Led Flash Quickly
Green Led Flash
Arming Delay TMEnable Arming
Standby Mode
(Arming is not enable)
Alarm Relay TM
Alarm Delay TM
Alarm trigger
Enable Arming status:

V230322
- 8 -
Illuminated Touch-panel
Access controller
IP Setting
Log-in User Password
When you choose the "Networking Setting" or "User Password" at rst.
Log-in window will pop out and please input
※ At the Factory Default
User name: SuperAdm
Password: 721568
Open your Web Browser and input factory default IP
address: ht tp://192.168.1.127
Networking Setting
You will nd initial IP Address 192.168.1.127 and check
MAC Address is the same as sticker on Ethernet Module
device. Please revise IP address you want, and then click
“Update” button. After updating the IP, please re-connect
the Web Browser by new IP address.
User Password
The password composes of 10 characters at most, it can be
either A~Z or 0~9.
Change the log-in password to lock the IP setting of
Ethernet Module.
If the IP address of AR-363-E has
changed We must enter the new
IP address.
Page menu
Current State
Online Status is able to monitor and show which computer is linking on
Ethernet Module
IP Setting
Monitor the on-line computer
Change the Log-in information
IP Setting
Show which computer is linking
on Ethernet Module.
Current IP address of the AR-363-E
Page menu
User Name is different from old and new version, password can be modify via [User Password]
setting on the list but will not be change from updating new version. If you forgot the password,
the solution is pressing Reset Button to reset it as default value.
NOTE :
Firmware Version User name Password (changeable)
After 2020/01/21 SuperAdm Default Password : 721568 or self-denition
Before 2020/01/21 admin Default Password : admin/ password not required or self-denition

SOYAL
ACCESS CONTROL SYSTEM
®AR-363-E
V230322
- 9 -
Command List
Function Command Exposition
Entering programming mode PPPPPP PPPPPP: Master Code, (Default value: 123456)
Exiting programming mode
Exiting programming mode and enabling all device
into arming status. Including AR-363-E, WG Reader
Enabling each device into arming status. U U=Enable target unit (0=AR-725-E , 1=WG Reader)
Node ID setting 00 NNN MMM AAA
NNN=Node ID,(001~254)
MMM=AR-363-E Door Number,(001~255)
AAA=WG Reader Door Number,(001~255)
IP Address assign (Must power reset)
01 0 CCCCCCCCCCCC
default value = 192 .16 8.1.127
CCCCCCCCCCCC = 192168001127
If set to 000.000.000.000 will enable DHCP otherwise
will disable DHCP
01 1 255255255000 Netmask
01 2 192168001254 Gateway assign
Door relay time setting 02 U TTT
U=Enable target unit (0=AR-363-E , 1=WG Reader)
TTT=Door relay time;000 (Output constantly)
001~600=1-600 Sec.;601~609=0.1~0.9Sec.
Alarm relay time setting 03 TTT TTT
=Alarm relay time;000 (Output constantly)
001~600=1~600 Sec.
Mode setting 04 M M=4 (Mode 4);M=8 (Mode 8)
Arming delay time setting 05 TTT Base on second, range: 001~255
Alarm delay time setting 06 TTT Base on second, range: 001~255
Master card setting 07 SSSSS EEEEE SSSSS-EEEEE=00000~15999
SSSSS= starting user address; EEEEE= ending user address
Auto-open zone setting 08 MW NN HHMMhhmm
7123456H
M=AR-363-E; W=WG Reader (0=disable; 1=enable)
NN=16 sets of auto-open zone (Range: 00~15)
HHMMhhmm=staring time to ending time
(e.g.: 08301200=08:30 to 12:00)
7123456: 7 days of week -Sun/Mon/Tue/Wed/Thu/Fri/Sat
(Input value: 0=disable; 1=enable)
H: Holiday (Input value: 0=disable; 1=enable)
Master code settings 09 PPPPPPRRRRRR PPPPPP= New master code
RRRRRR= Repeat the new master code
Suspend or delete tags Suspend:10 SSSSS EEEEE :Suspend :Delete
SSSSS= starting user address; EEEEE= ending user address
Delete: 10 SSSSS EEEEE
Recover tag 11 SSSSS EEEEE SSSSS= starting user address; EEEEE= ending user address
Setting up Card or PIN mode by user addressModify the
user's access PIN according to the user's address, and
change the control mode to "Card or PIN"
12 UUUUU PPPP~PPPPPPPP
UUUUU= user address;
PPPP~PPPPPPPP=4digit (default)~8-digit individual PWD
(Access mode: Card or PIN)
Setting up Card and PIN mode by user address 13 UUUUU PPPP~PPPPPPPP
Arming output setting 14 TTT Base on 1ms, range:1~255, default value=10,
Input 0= Timeless
Duress code setting 15 PPPP
PPPP=4-digit PWD (0001-9999) ; Default value:0000
※The Duress Code 0000 means that disable Duress Function
and the default value is set as 0000 already.
Card number modication 16 UUUUU SSSSSCCCCCC UUUUU=user address
SSSSS=5 digit site code ; CCCCC=5 digit card code
Arming PWD setting 17 PPPP PPPP=4-digit PWD (0001-9999)
Default value:1234
Enabling or Disabling into arming status Card+NNNN NNNN
:Arming PWD
U=Enable target unit (0=AR-363-E , 1=WG Reader)
Enabling or Disabling each device into arming status. Card+NNNN U
Enabling all device into arming status. Card+NNNN
Disabling all device into arming status. Card+NNNN
Door open waiting time 18 U TTT U=Enable target unit (0=AR-363-E , 1=WG Reader)
TTT=Door open waiting time:001~600;default value:15 sec.
Add card by presenting 19 UUUUU QQQQQ UUUUU=user address
QQQQQ=Card quantity(00001=Continuously inducting)
Reader additional setting 20 U DDD U=Enable target unit (0=AR-363-E , 1=WG Reader)
DDD=Function default value
9
9
9

V230322
- 10 -
Illuminated Touch-panel
Access controller
Command List
Function Command Exposition
Lift control setting: multi-doors 21 UUUUU G LLLLLLLL UUUUU=user address;G=4 sets of lift control(0~3);
LLLLLLLL=8 assigned oor (F=0: Disable, 1: Enable)
Add/Delete tag by presenting (M6 only) 22 N N=0(Delete tag); N=1(Add tag)
AR-401RO16/ AR-401RO16B relay time setting 23 MMM TTT MMM=Node ID of lift controller
TTT= relay time: 000~600=1~600 sec.
Factory setting 24 0 or 1 ???
0 or 1=Enable target unit (0=Main Controller Parameter
Setting , 1=WG Input Port Parameter Setting)
???
:Function default value
Real time clock setting 25 YYMMDDHHMMSS YYMMDDHHmmSS: Year/Month/Day/Hour/Min./Sec.
Anti-pass-back (Enable user) 26 SSSSS EEEEE P SSSSS= starting user address; EEEEE= ending user address
P=0=Enable; P=1=Disable; P=2=Initial
Lift control setting: single door 27 UUUUU LL UUUUU=user address;LL:Floor number(01~64 oor)
Duress Function and Arming output setting 28 ??? Arming output and Duress function: ???= 008 (default value)
Delete all tag 29 29
Same tag reading interval time 31 TTTT Base on 10ms, range from 10 to 6000
Auto ring the clock alarm schedule 32 SS HHMMTT 7123456H
SS= 16 sets auto alarm schedule, range 0~15
HHMM= HH:MM (ex. 0830: Ring bell at 08:30)
TT=Period of time to ring bell
(Base on second, range 01~99 sec.)
7123456: 7 days of week -Sun/Mon/Tue/Wed/Thu/Fri/Sat
(Input value: 0=disable; 1=enable)
H: Holiday (Input value: 0=disable; 1=enable)
Holiday Setting 35 MMDD F
MM= Month of year (01=Jan...10=Oct.)
DD= Date of month (01=1st day of month)
F= 0:Delete ; 1: Add
Enabling or Disabling into Full Access status 36 MW M=AR-363-E; W=WG Reader (0=disable; 1=enable)
RS485 port function setting
(Needs to be restarted after setting) 37 AB
A=0:AR401RO B=0: 9600(default value)
1:Host (default value) 1: 19200
2:LED Panel 2: 38400
3:Printer 3: 57600
TTL port BAUD setting 38 DDD DDD : 001=4800 bps DDD : 065=9600 bps
DDD : 129=19200 bps
Change WG bits output format 41 n n:0=WG26 ;n:1=WG34
PIN & UID Length setting 42 m n m=PIN code Length 4~8 Digit / n=UID Length 2~8 Digit
Compound Command Function List
20 0 ??? (Main Controller Parameter Setting)
20 1 ??? (WG Input Port Parameter Setting) ※Default Value
Function Option Value Bit Application
Entry and Exit Access is recorded on Duty Report ※0: Yes 1: No 001 0Networking
Activate close door automatically lock (Auto-Relock) ※0: Disable 1: Enable 002 1Networking/Stand-Alone
Auto Open ※0: Disable 1: Enable 004 2Networking/Stand-Alone
When Access Mode is "Card and PIN", Readers can skip pressing PIN code ※0: Disable 1: Enable 008 3Networking/Stand-Alone
Exit by Push Button 0: Disable ※1: Enable 016 4Networking/Stand-Alone
Enable force Open trigger alarm ※0: Disable 1: Enable 032 5Networking
Entry/Exit Reader ※0: Exit 1: Entry 064 6Networking
Anti-pass-back ※0: Disable 1: Enable 128 7Networking
Weighted Value Manual :
"Selection" of the function that you need is either
have 0 or 1 value.
Substract the "Value" of each Option with Selection.
Function = [0(deactive)*Value] ; [1(activate)*Value]
Add up all of the Function per Compound Command
(20 , 24 ,etc)
Step 1:
Select the "Function" that you need for each
Compound Command category (20 , 24 , etc)
Step 2:
Step 3: Step 4:

SOYAL
ACCESS CONTROL SYSTEM
®AR-363-E
V230322
- 11 -
34 ???
Function Option Value Bit Application
※Default Value
※0
:
Disable
※0
:
Disable
※0
:
Disable
※0
:
Disable
※0
:
Disable
Networking/Stand-Alone
Networking/Stand-Alone
Networking/Stand-Alone
Networking/Stand-Alone
Networking/Stand-Alone
001
002
004
008
016
1
:
Enable
1
:
Enable
1
:
Enable
1
:
Enable
1
:
Enable
0
1
2
3
4
Turn o buzzer function
Any error trigger alarm (ex: swipe invalid card)
Reserved
Turn o 13.56MHz reading function
Turn o 125kHz reading function
44 ???
Function Option Value Bit Application
※Default Value
※0
:
Disable
※0
:
Disable
※0
:
Disable
※0
:
Disable
※0
:
Disable
Networking/Stand-Alone
Networking/Stand-Alone
Networking/Stand-Alone
Networking/Stand-Alone
Networking/Stand-Alone
001
002
004
008
016
1
:
Enable
1
:
Enable
1
:
Enable
1
:
Enable
1
:
Enable
0
1
2
3
4
Access valid door relay remain locked
Master/Slave interlocking (Master open, Slave
could not open door)
Reserved
Stop card access (access only by PIN or PC
remote open door)
Reserved
※More Details:Introduction of New Function Commands for Enterprise E Controller and Home H Controller
28 ??? ※Default Value
Function Option Value Bit Application
Expiry User Access Trigger Alarm ※0: Disable 1: Enable 001 0Networking/Stand-Alone
Reset Anti-Passback on Timezone 61 ※0: Disable 1: Enable 002 1Networking/Stand-Alone
--- ---- ---- 004 2----
Duress and Arming Output function 0: Wiegand Output 1: Arming and Duress Output 008 3Networking/Stand-Alone
RS-485
Lift Control: 0 000
4-5 Networking/Stand-Alone
Host: 1 016
LED Board: 1 032
Printer: 1 048
---- ---- ---- 032 6----
---- ---- ---- 064 7----
24 0 ??? (Main Controller Parameter Setting)
24 1 ??? (WG Input Port Parameter Setting) ※Default Value
Function Option Value Bit Application
Enable Egress Beep Sounds 0: Disable ※1: Enable 001 0Networking/Stand-Alone
---- ---- ---- 002 1----
---- ---- ---- 004 2----
Arm/Disarm Zone(Zone: 62) ※0: Enable 1: Disable 008 3Networking/Stand-Alone
Reader and controller share the same door relay
(only for WG reader)
0: Disable ※1: Enable 016 4Networking/Stand-Alone
◎Enable swipe any tags to release door open ※0: Disable 1: Enable 032 5Networking/Stand-Alone
Stop alarm by pressing push button or closing the door ※0: Disable (must swipe valid card) 1: Enable 064 6Networking/Stand-Alone
Enter auto open time zone without presenting valid card ※0: Disable (must present valid card rst) 1: Enable 128 7 Networking/Stand-Alone
◎Add value 032 means to activate, deduct value of 032 means to disactivate the function of swipe any tags to release door open
Table of contents
Other Soyal IP Access Controllers manuals

Soyal
Soyal AR-331-E User manual

Soyal
Soyal AR-327H User manual

Soyal
Soyal AR-723 User manual

Soyal
Soyal AR-327-E User manual

Soyal
Soyal AR-888-PBI-S User manual

Soyal
Soyal AR-725E User manual

Soyal
Soyal AR-837-EA-T User manual

Soyal
Soyal AR-888U User manual

Soyal
Soyal AR-321H User manual

Soyal
Soyal AR-888H User manual

Soyal
Soyal AR-721K User manual

Soyal
Soyal AR-721U User manual

Soyal
Soyal AR-327-E User manual

Soyal
Soyal AR-721K User manual

Soyal
Soyal AR-837-E User manual

Soyal
Soyal AR-723-H User manual

Soyal
Soyal AR-327-E User manual

Soyal
Soyal AR-821EF User manual

Soyal
Soyal AR-721KP User manual

Soyal
Soyal AR-837-E User manual