V110810
Keypad
Programming
C. Add a User Code to the system
B. Set up user number corresponding to door relay
D. Set the door relay-1 release time
E. Set time out value
F. Set keypad lock of continuous error operation
Enable a (range of) User(s) Code to the system
Press 123456 (or Master Code) → 11 SSS EEE → Done (A green light and beep means that the user code(s) was enabled. )
[e.g.] Enable User code 58 to the system
:
Access programming mode → 11 058 058 → Done
[e.g.] Enable User code 1 to 10 to the system
:
Access programming mode → 11 001 010 → Done
[e.g.] Set user code 123 to user 001
:
Access programming mode → 12 001 123 → Done
Access programming mode → 12 UUU PPPPPP
UUU(User address)
:
001~254
;
PPPPPP(User Code)
:
The user code must be 3 to 6 digits in length and the key # cannot be used in a code.
[e.g.] Set user code 123456 to user 002
:
Access programming mode → 12 002 123456 → Done
Access programming mode → 01 UUUU UUUU=User address (Default value = 0250)
[User number 0000~0249 operates Relay_A; User number 0250~0499 operates Relay_B.]
Access programming mode → 04 TT TT = 00~09 (0~0.9) seconds; TT = 10~49 (1~4.9) seconds
Access programming mode → 06 PPP PPP = 000 (Disable) / PPP = 001 (Enable) [If use two access groups, places set disable.]
G. Set Door bell ( + Door Ring)
Access programming mode → 05 T T = 3~9 (times); T = 0 (Close this Function)
[e.g.] Set three incorrect user code are entered
:
Access programming mode → 05 3 → Done
A. Entering and Exiting Programming Mode
Changing the Master Code
Access programming mode → 09 PPPPPPRRRRRR [Input the 6-digit new master code twice.]
[e.g.] If want to changing the Master Code= 876112, input 123456 → 09 876112876112
Exiting
Input
Entering
Input 123456 or PPPPPP
[e.g.] The Default Value= 123456, if already changed the Master Code= 876112, input 876112 → Access programming mode
Access programming mode → 02 TTT
Set door relay_B, enter 03.
TTT = 000 Latch(Toggle) / TTT = 001~600 (001~600) seconds.
TTT =601~609 (0.1~0.9) seconds.
Command List
Function Command Exposition
Entering programming mode PPPPPP PPPPPP: Master Code, (Default value: 123456)
Exiting programming mode
User number corresponding to door relay 01 UUUU UUUU=User address, (Default value: 0250); User before the
250th is the rst group, the other is the second group.
Relay_A time setting 02 TTT TTT
=Door relay time;000 (Output constantly)
001~600=1-600 Sec.;601~609=0.1~0.9 Sec.
Relay_B time setting 03 TTT TTT
=Door relay time;000 (Output constantly)
001~600=1-600 Sec.;601~609=0.1~0.9 Sec.
Set time out value 04 TT TT
=Keypad operate during time
Range
:00 ~ 09 (0 - 0.9) Sec.;10 ~ 49 (1 - 4.9) Sec.
Set keypad lock of continuous error operation 05 T T
=Continuous error times
:3 ~ 9 (Times)
;T
=0 (Disable)
Door bell 06 PPP PPP=000 ( Disable ) / PPP=001 ( Enable )
Master code settings 09 PPPPPPRRRRRR PPPPPP= New master code
RRRRRR= Repeat the new master code
Suspend or delete user code 10 SSS EEE SSS= starting user address ; EEE= ending user address
Recover user code 11 SSS EEE SSS= starting user address ; EEE= ending user address
Add a User Code to the system 12 UUU PPPPPP UUU=User address
PPPPPP=3 to 6 digits
Delete (Remove) a User Code 14 UUU UUU=User address
Delete (Remove) all Users Codes 29 29
Factory Reset by its commands
If the master code is forgotten it can be restored to the factory default. Remove the AR-721KP from the mounting plate. Press and hold the reset switch
5 seconds. LED light green during 2.5 seconds and ve beep sounds mean that master code have restored to the factory default 123456.
Delete (suspend) a (range of) User(s) Code from the system
Press 123456 (or Master Code) → 10 SSS EEE →Done (A green light and beep means that the user code(s) was disabled. )
[e.g.] Delete (suspend) User code 58
:
Access programming mode → 10 058 058 → Done
[e.g.] Delete (suspend) User code 1 to 10
:
Access programming mode → 10 001 010 → Done