12
34
56
78
90
最佳感應區
- 1 -
Contents
1Product
Security Torx Wrenches
Security Torx: M3x10
Flat Head Cap Philips
Tapping Screw: 4x20
Installation
Peel o screw hole rubbers and frame rubber from rubber pad
Put screw rubbers on the back side of the mounting plate and pull
the cables from the square hole of the mounting plate.
Put a frame rubber on the frame groove of body
Connect the terminal cables to the body and attach the body to the
mounting plate.
Assemble the covers with the Allen key and screws (accessories supplied).
Turn on the power and LED will light and beep will sound.
4Accessories
2Terminal Cables 3Tools
Front Panel & Indicator
While power on the device,
hands off the touch panel
for 10 sec. to make sure
a successful activation.
Peel
off
screw
rubber
Peel
off frame
rubber
4
5
1
4
2
3
5
6
7
Screws
Rubber
Frame
Rubber
Put on/Take off together
5Option
Arming / Blue LED
Input (Active High)
Yellow LED Input
(Active High)
Left LED Descrption Descrption
Yellow
Blue Power-on/Stand-by
/OK
Error/Alarm
Right LED
Green
Red
Rubber Pad TCP/IP
Module
158 mm
55 mm
30 mm
27.5 mm
19 mm 87 mm 22 mm
16.5 mm
27.5 mm
34 mm
14
(Front View) (Side view)
INSTALLATION

V221226
AR-321H
EXIT
E
12V
GND
12V
GND
12V
GND
N.O.
GND
N.O.
COM
PB
12V
GND
3
4
5
6
7
8
2
1
CN1
EXIT
N.C.
COM
PB
12V
GND
N.O.
N.O.
COM
N.C.
V+
V-
Main Port
Main Port CN2
1
2
3
5
6
7
8
4
9
WG Port
5
CN2
1
2
3
5
6
7
8
4
9
WG Port
5
P.T.Exit
- 2 -
8
89
CN1CN4
CN2 CN6
CN11
CN9
CN3
CN5
Fingerprint
Biometrics Device Access controller
Wire Application Wire Color Description
Lock Relay 1Blue White (N.O.)DC24V1Amp
2
Purple White
(N.C.)DC24V1Amp
Common-COM-Point
3White (COM)DC24V1Amp
Door Sensor 4Orange Negative Trigger Input
Exit Switch 5Purple Negative Trigger Input
Alarm Relay 6Gray Transistor Output Max. 12V/100mA
(Open Collector Active Low)
Power 7Thick Red DC 12V
8Thick Black DC 0V
CN1Cable:
Wire Application Wire Color Description
Beeper 2Pink Beeper Output 5V/100mA, Low
LED 3Yellow Red LED Output 5V/20mA, Max
4Brown Green LED Output 5V/20mA, Max
Door Output 5Blue White Transistor Output Max. 12V/100mA
(Open Collector Active Low)
Wiegand 6Thin Green Wiegand DAT: 0 Input
7Thin Blue Wiegand DAT: 1 Input
WG Door Sensor
8Orange Negative Trigger Input
WG Exit Switch 9Purple Negative Trigger Input
CN2Cable:
1White
DI1 Reserved
Wire Application Wire Color Description
Anti-Tamper
Switch
1Red N.C.
2Orange COM
3Yellow N.O.
CN5Cable:
Wire Application Wire Color Description
Power 1 Red DC 12V Output
Security trigger signal
2Purple Security trigger signal Output
Arming 3Red White Arming Output
Duress 4 Yellow White Duress Output
CN6Cable:
Wire Application Wire Color Description
1 --- ---
2 --- ---
TCP/IP Output
3Yellow Net - TX+
4Green Net - TX-
5Red Net - RX+
6Black Net - RX-
7 --- ---
CN3Cable:
Wire Application Wire Color Description
TTL Output
1Blue CLK
2 Red DC 5V
3
Orange
RX
4White TE
5Yellow TX
6Black DC 0V
CN9Cable:
Wire Application Wire Color Description
RS-485 for Lift
Controller
1Thick Green RS-485(B-)
2Thick Blue RS-485(A+)
CN4Cable:
Connector Table
Connect to Electric Bolt Connect to Magnet Lock
Wiring Diagram
Electric Bolt
AR-1207
Controller Controller
RTE RTE
POWER
12VDC
POWER
12VDC
POWER
12VDC
POWER
12VDC
Magnet Lock

V221226
AR-331-E/EF
SOYAL
ACCESS CONTROL SYSTEM
N.C.
N.O.
CTL
12V
Door
Sensor
ALM
12V
GND
12V
GND
12V
GND
12V
GND
N.C.
CN1
CN1
N.O.
COM
PB
12V
GND
3
2
1
EXIT
12V
GND
12V
GND
12V
GND
N.O.
GND
4
5
6
7
8
1
2
3
4
5
6
7
8
COM
N.C.
N.O.
COM
CTL
12V
E
12V
GND
12V
GND
CN2
CN1
BZ
RLED
GLED
Door Output
WG 0
WG 1
WG-DS
WG-PB
N.C.
1
2
3
4
5
6
7
8
1
2
3
5
6
7
8
4
BZ
RLED
GLED
WG 0
WG 1
12V
GND
9
RTE
EXIT
E
WG Port
Main Port
Main Port
Main Port
5
CN2
1
2
3
5
6
7
8
4
9
WG Port
5
CN2
1
2
3
5
6
7
8
4
9
WG Port
5
P.T.Exit
EXIT
12V
GND
12V
GND
N.O.
12V
GND
CN4
N.C.
N.O.
COM
CTL
12V
GND
PB
12V
GND
DDR
CN8
3
4
5
6
7
8
2
1
4
1 2 3
- 3 -
Controller
Controller
Controller
Reader
Controller
RTE
RTE
POWER
12VDC
POWER
12VDC
POWER
12VDC
POWER
12VDC
POWER
12VDC
POWER
12VDC
POWER
12VDC
POWER
12VDC
Connect to Electric Strike
Electric Strike Alarm
Relay Output Module
Door Sensor
Connect to Door Sensor
Strengthen security with Digital Relay Board
Electric Bolt
Connect to Reader
Digital Relay Board
※ The Wiring of Enable "Share Door Relay" ( Set up via the parameters setting Window of 701ServerSQL)
※ The Wiring of Disable "Share Door Relay" ( Set up via the parameters
setting Window of 701ServerSQL
Electric Bolt
AR-1207
Electric Bolt
AR-1207
※ This wiring method is not eligible for "Share Door Relay" function (set up
via parameter setting of 701ServerSQL). If there is external wiring to Wiegand
reader, WG Port must enabled Digital Relay Output to enable "Share Door
Relay" function.
,AR-331-E/EF become WG mode
(28 000 )
※Using Rule :
Finger : Both AR-331-EF Master mode and AR-331-EF WG mode must
store all the same FP data and real or visual card number.
Card : Can pass WG message to controller.
WG Mode / Controller Mode Setting Method
1. AR-331-E/EF can be set up as WG26/WG34/WG64 while the
Controller is in WG Mode. These Controller can also be paired
with the Controller that has WG input function.
2. AR-331-E/EFsupport Anti-pass-back by nger or card.
3. Networking Setting: Select E Series Controller Parameter Edit
in 701Server,tick up the function“Ev5 WG out/Hv3 Lift out”
4. Please restart the controller after pressing“Write to Controller”.
12V
GND
CN4 CN4
CN8
CN5
CN5
BZ
RLED
GLED
Door Output
WG 0
WG 1
DSS
PB
DSS
PB
Duress
ARM
PB
12V
GND
12V
GND
3
4
5
6
7
8
3
4
5
6
7
8
1
2
3
5
6
7
8
1
2
3
5
6
7
8
1
21
2
4
4
1
2
3
4
331-E/EF331-E/EF
WG Mode Controller Mode
701ServerSQL Parameter Setting
701ServerSQL Parameter Setting
POWER
12VDC

V221226
- 4 -
Fingerprint
Biometrics Device Access controller
Adding and Deleting Tag
Changing the Master Code
Access programming mode → 09 PPPPPPRRRRRR [Input the 6-digit new master code twice.]
[e.g.] If want to changing the Master Code= 876112, input 123456 → 0 9 876112876112
Exiting
Input
Access programming mode → 00 NNN MMM AAA
[NNN= Node ID: 000~254; MMM=AR-331-E/EF Door NO.:1~255; AAA=WG Reader Door NO.:1~255
B. Changing the Node ID of Reader
Programming
A. Entering and Exiting Programming Mode
Entering
Input 123456 or PPPPPP
[e.g.] The Default Value= 123456, if already changed the Master Code= 876112, input 876112 → Access programming mode
Add New Tags
Add by Presenting Tags (apply to Single Tag or a Batch of Tags)
[Add single tag] Add a new tag for selected user address 100:
Enter program mode → 19 00100 00001 → Present the tag → Successfully added tag of user 100
[Add 2 additional tags] Add new tags to the following user address 101-102:
Enter program mode → 19 00101 00001 → Present (User 101) card → Present (User 102) card
→ Successfully added tags of user 101-102
[Add 10 additional tags] Add new tags to the following user address 103-112
Enter program mode → 19 00103 00001 → Present (User 103) card → Present (User 104) card → Present (...) card
→Present (User 111) card →Present (User 112) card →Successfully added tags of user 103-112
※Important Notice: Please remember the last user address being added to make sure the old user data is not being over written
with the new card in the future.
Delete All Tags
Input 123456 (or Master Code) → 29 29
Delete Single Tag or a Batch of Tags (by User Address)
Input 123456 (or Master Code) → 10 SSSSS EEEEE
[e.g.] Delete User Address: 00058
Enter program mode → 10 00058 00058
[e.g.] Delete User Address: 00058~00063
Enter program mode → 10 00058 00063
9
9
9
Tag Information
(125kHz) ※ For Mifare tags, the separator between Site Code & Card Code is comma ",".
SITE CODE
CARD CODE
SITE CODE
CARD CODE
Delete Tags
Mode Support User
Capacity Access Mode Event
Capacity
120
Holidays Duress Time
Zone
Lift
Control
Anti-pass-
back
M4
Networking/
Stand-Alone
16,000
(0~15,999)
1.Card only
2.Card and PIN (4-8 digit PIN Can be set)
3.Card or User address (5-digit) + Individual PIN
(4-8 digit individual PIN Can be set ) 32,000 V V unlimited 64 V
M8
1.Card only
2.Card and PIN (4-8 digit individual PIN Can be set)
3.Card or PIN (4-8 digit individual PIN Can be set)
C.Setting up the control mode (M4/M8)
Access programming mode → 04 N [N=4/8]
[Add 50 consecutive tags] Add 50 new tags with consecutive card number following user address 00050-00150:
Enter program mode → 19 00050 001001 →Successfully added tags of user 50-150
Add Non-consecutive Tags:
Add Consecutive Tags:

V221226
AR-331-E/EF
SOYAL
ACCESS CONTROL SYSTEM
- 5 -
Enable device
Access programming mode → 20 0 or 1 ??? 0 or 1= Enable target unit
(
0=Main Controller Parameter Setting,1=WG Input Port Parameter Setting)
[Please refer to Compound Command Function List for details.]
[e.g.] If the AR-331-E/EFset to exit reader, WG Reader set to access reader.
Access programming mode → 20 0 128 → 20 1 192 [Please refer to fCompound Command Function List for details.]
Enable/Disable auto open zone
Access programming mode → 20 0 or 1 ??? 0 or 1= Enable target unit
(
0=Main Controller Parameter Setting,1=WG Input Port Parameter Setting)
[Please refer to Compound Command Function List for details.]
[e.g.] If the AR-AR-331-E/EFset to Enable aut open zone.
Access programming mode → 20 0 004 [Please refer to function default value for details.]
[e.g.] If the WG Reader set to Enable aut open door without presenting card.
Access programming mode → 24 1 128 [Please refer to function default value for details.]
Enable/Disable auto open door without presenting one valid card
Access programming mode → 24 0 or 1 ??? 0 or 1= Enable target unit(0=Main Controller Parameter Setting,1=WG Input Port Parameter
Setting) [Please refer to Compound Command Function List for details.]
[e.g.] User address from 00152 to 00684 enable the anti-pass-back function: 26 00152 00684 0
Enable card user
Access programming mode → 26 SSSSS EEEEE P SSSSS= starting user address; EEEEE= ending user address [P=0 Enable/ P=1 Disable/ P=2 Reset]
[e.g.] AR-331-E/EF(without WG reader), to set second time zone which could be passed only at 9:30am to 4:20pm on Mon, Wed and Fri.
Access programming mode → 08 10 02 09301620 01010100 → setting is completed
Setting up access time
Access programming mode → 08 MW NN HHMMhhmm 7123456H [M=AR-331-E/EF; W=Reader(0=disable,1=enable); NN: 16 sets of
auto-open zone (NN=00~15); HHMMhhmm=Starting time to ending time; 7123456H= 7 days of week + Holiday (F= 0: disable; 1: enable)]
Usually, anti-pass-back is commonly applied to parking areas in order to prevent from multi-entry with one card at a time, or somewhere wants to
monitor not only the access but also exit condition.
Door will remain open after ashing one valid card. When the reader is stand-alone, supporting only 16 sets of auto-open zone by device setting.
Auto-open zone can extend up to unlimited sets by Networking.
Please refer to paragraph Compound Command Function List below to ensure command 20 0 or 1 ??? / 24 0 or 1 ??? will not
reset the functions that already had been changed.
F. Anti-pass-back
G. Auto Open Access (uncontrolled) Time Zone – Automatically Release
H. Lift control
Single oor
[e.g.] User address NO. 45 only can reach the elevator to the 24th oor: 27 00045 24
Access programming mode → 27 UUUUU LL
UUUU=User Address LL=Floor number (01~64 oor)
Connect with AR-401-IO-0016R to control oors which the user will be able to access. [BAUD9600]
D. Setting up the password
E. PIN & UID Length setting
Individual PWD (M4/M8)
Card or PIN: Access programming mode → 12 UUUUU PPPP [e.g. User address: 00001 and PWD: 1234. Input 12 00001 1234 ]
Card and PIN: Access programming mode → 13 UUUUU PPPP [e.g. User address: 00001 and PWD: 1234. Input 13 00001 1234 ]
Access programming mode → 42 m n 【m=PIN code Length 4~8 Digit;n=UID Length 2~8 Digit】(4 is default value)
Example:42 8 4 【PIN code Length 8 Digit;UID Length 4 Digit】

V221226
- 6 -
Fingerprint
Biometrics Device Access controller
I. Setting Up the Arming
Arming ModeDisarming Mode
TriggeringAlarm
Condition:
TriggeringAlarm
Condition:
VS abnormaldoor
position
dooropentoo
long
doorisforced
openg
doorisforced
openg
In the security management of access control system, the controller or reader status is divided into Standby Mode or Disarming Mode and Arming
Mode. The conditions for triggering the alarm in these two modes is dierent, as shown in the following comparison:
Alarm conditions:
1. Door is forced open
Application:
1. Door open too long: Door is open longer than door relay time plus door close time.
2. Force open (Opened without a valid user card): Access by force or illegal procedure.
3. Door position abnormal: Arming is enabled and the power is suddenly o then on.
1.Normal Opening
Arming Setting and Alarm Trigger Procedure :
Door Relay TMArming Delay TMEnable Arming Alarm Relay TMDoor Close TM Alarm Delay TM
Enable
Arming Status
Alarm Trigger
Door open
Green Led Flash Quickly Red Led Flash Quickly
Alarm trigger
Green Led Flash
Standby Mode
(Arming is not enable)
2.Abnormal Opening
Enable
Arming Status Alarm Trigger
Green Led Flash Quickly Red Led Flash Quickly
Green Led Flash
Arming Delay TMEnable Arming
Standby Mode
(Arming is not enable)
Alarm Relay TM
Alarm Delay TM
Alarm trigger
Set
(G)
Floor
L
8
16
24
32
40
48
56
64
0
1
2
3
4
5
6
7
L
6
14
22
30
38
46
54
62
L
7
15
23
31
39
47
55
63
L
5
13
21
29
37
45
53
61
L
4
12
20
28
36
44
52
60
L
3
11
19
27
35
43
51
59
L
2
10
18
26
34
42
50
58
L
1
9
17
25
33
41
49
57
Please refer to below oor chart
[e.g.] User address NO. 168 can reach only the 6th and 20th oor:
Access programming mode → 21 00168 0 00100000
→ 21 00168 2 00001000 → OK (Please refer to oor chart as right.)
Multi oors
Access programming mode → 21 UUUUU G LLLLLLLL
[UUUUU=User address G: 8 sets of lift control (Input: 0~7) LLLLLLLL:
8 oors setting (L=0=Disable, L=1=Enable)
Enable all devices: Access programming mode → Enable particular device: Access programming mode →
0 or 1
Disable Arming status:
Standby Mode
Standby Mode
Enter Program Mode
Card only
Card only
Card or Passcode
Card or Passcode
Card and Passcode
Card and Passcode
※ Factory default armingcode is: 1234. 0 or 1=Reader unit (0=Main Controller Parameter Setting,1=WG Input Port Parameter Setting ).
Enable all devices
Induct valid card → Input 4 digit
arming code →
Enable particular device
Induct valid card →Input 4 digit
arming code →0 or 1 or
Disable particular device
Induct valid card →Input 4 digit
arming code →0 or 1 or
Input 5 digit user address → Input 4
digit pass code → → Input 4 digits
arming code → or
0 or 1
Induct valid card →Input 4 digit pass
code →→ Input 4 digits arming
code →or
0 or 1
Disable all devices
Induct valid card → Input 4 digit
arming code → 9
Input 5 digit user address → Input 4
digit pass code → → Input 4 digits
arming code → or 0 or 1
9
Induct valid card →Input 4 digit pass
code →→ Input 4 digits arming
code →or 0 or 1
9
Enable Arming status:

V221226
AR-331-E/EF
SOYAL
ACCESS CONTROL SYSTEM
J. Adding / Deleting Fingerprint
K. Enable/Disable Skip Finger/Tag
Adding
How to add a nger data:
Access programming mode → Place your nger on the sensor
[F=1= Adding 1 Finger data; F=2= Adding 2 Finger data; UUUUU= User address]
FUUUUU
93
Deleting
UUUUU= User address
Access programming mode → 0UUUUU
93
Deleting All
Access programming mode → 999999
93
※Adding 2nd/3rd Fingerprint → Repeat 1st nger process
※If you hear continuous "beep..." sounds when you place nger on the sensor, please release your nger from the sensor.
(Please consult detail command on page 8.)
Command Setting Software Setting Access Mode Way
40 1 NNNNN EEEEE
40 3 NNNNN EEEEE Just ngerprint
Just card control
FP rst and then Tag First Then
40 0 NNNNN EEEEE
40 2 NNNNN EEEEE Just ngerprint
Just card control
FP only or Tag only
Access programming mode →
NNNNN=starting user address
EEEEE= ending user address
F=1+3(Default Value)
FNNNNN EEEEE
04
or
L. Adding / Deleting Fingerprint
1. For dual-ngerprint sensor module version, capactive sensor module is the only enabled way for enrolling FP.
2. For dual-ngerprint sensor module version, user just can select one of ngerprint sensor for identication and can't put two ngerprints to dierent sensor at the same time.
3. Extra WG keypad panel is needed for adding card or downloading data connected to PC.
4. Each nger need to be collected 1 times enrolling for AR-331-E/EF.
M. The process of FP identication
1. While attached a nger on biometric sensor, there is a beep sound for starting the scanner. Then, please don't move your nger until the AR-331-EF makes
another beep sound.
2. If there is a 8-beep sound after user gets access by FP, the FP data shall be reset by command 39*9*99999# under the programming mode.
Cautions: Before reset the FP, please backup the data from source FP rst.
Adding 1
Fingerprint
( After Bi sound, please remove the the nger
from unit. Each nger shall collect for 3 times ) (OK)
Put 1st
Finger Bi Long Bi
Restoring Factory Settings
Reset all device parameters and user card data
Reset User Data &Controller Parameter :
Access programming mode → 29 20
Reset User Data &Controller Parameter (incl. Master Code)
& Reset Parameter Setting- SOR :
Access programming mode → 29 21
Reset IP Setting:
Access programming mode →Press “IP Resent Button” of main board for few seconds. (Reference to picture)
Reset User Data :
Access programming mode → 29 29
※ After operation as above, you will hear the long reminder sound,and wait until the
sound disappear then reset the power of the controller,the device will restore factory setting.

V221226
3
4
5
7
8
1
2
6
- 7 -
24
5
3
1
Fingerprint
Biometrics Device Access controller
Firmware Upgrade
EnrollTool Setting
Get the upgrade software from SOYAL or our distributor and run “UdpUpdater” software
Update the rmware
[Please login the SOYAL web to download the new ISP Firmware.]
1. Input the Target Address and Port
2. [Load F/W] open the documents that have the new ISP Firmware
3. Click the new ISP Firmware and [Open] it
4. Click [Update Device] to start the rmware update
5. Till the screen shown [Firmware Update is Complete]
Execute the software
The software is Login the SOYAL web to downloads
Transfer ngerprint format V9 -> V5
7. Click "SIF→FP5 " ,select old AR-331EF FP le format. SIF , the
system will automatically generate new single FP le format. FP5
into 701Server folder.FP5 into 701Server folder.
Deleting ngerprint database on the device
8. Click"Delete All" , all Fingerprint data from device will be deleted
completely.
1. Select correct "COM Port".
2. Select "Node ID" of the device. Input "User Address".
3.
Select the numberof enrolled ngers in assigned path ( 1FP or 2FP per User).
4. Select the device type
"
AR-331-EF
".
5. Select “Save Path” in which will save ngerprint data.
6.
Click “Enroll”, follow pop-up picture and Status bar to enroll FP as below:
Connect to Controller
—》
Place 1st nger 1st time to Finger sensor
—》
remove nger
—》
Place 1st nger 2nd time
—》
remove nge
—》
Place
2nd nger 1st time
—》
remove nger
—》
Place 2nd nger 1st time
—》
Save FP data to File
—》
Registration Completed.

V221226
AR-331-E/EF
SOYAL
ACCESS CONTROL SYSTEM
- 8 -
IP Setting
Log-in User Password
When you choose the "Networking Setting" or "User Password" at rst.
Log-in window will pop out and please input
※ At the Factory Default
User name: SuperAdm
Password: 721568
Open your Web Browser and input factory default IP
address: http://192.168.1.127
Networking Setting
You will nd initial IP Address 192.168.1.127 and check
MAC Address is the same as sticker on Ethernet Module
device. Please revise IP address you want, and then click
“Update” button. After updating the IP, please re-connect
the Web Browser by new IP address.
User Password
The password composes of 10 characters at most, it can be
either A~Z or 0~9.
Change the log-in password to lock the IP setting of
Ethernet Module.
If the IP address of AR-331-E/EF has
changed We must enter the new IP
address.
Current IP address of the AR-331-E/EF
Page menu
Current State
Online Status is able to monitor and show which computer is linking on
Ethernet Module
IP Setting
Monitor the on-line computer
Change the Log-in information
User Name is different from old and new version, password can be modify via [User Password]
setting on the list but will not be change from updating new version. If you forgot the password,
the solution is pressing Reset Button to reset it as default value.
NOTE :
Firmware Version User name Password (changeable)
After 2020/01/21 SuperAdm Default Password : 721568 or self-denition
Before 2020/01/21 admin Default Password : admin/ password not required or self-denition

V221226
- 9 -
Fingerprint
Biometrics Device Access controller
Command List (By WG Keyboard)
Function Command Exposition
Entering programming mode PPPPPP PPPPPP: Master Code, (Default value: 123456)
Exiting programming mode
Exiting programming mode and enabling all device
into arming status.
Including AR-331-EF, WG Reader
Enabling each device into arming status. U U=Enable target unit (0=AR-331-EF , 1=WG Reader)
Node ID setting 00 NNN MMM AAA
NNN=Node ID,(001~254)
MMM=AR-331-EF Door Number,(001~255)
AAA=WG Reader Door Number,(001~255)
IP Address assign (Must power reset)
01 0 CCCCCCCCCCCC
default value = 192.16 8.1.127
CCCCCCCCCCCC = 192168001127
If set to 000.000.000.000 will enable DHCP otherwise
will disable DHCP
01 1 255255255000 Netmask
01 2 192168001254 Gateway assign
Door relay time setting 02 U TTT
U=Enable target unit (0=AR-331-EF , 1=WG Reader)
TTT=Door relay time
000 (Output constantly)
001~600=1-600 Sec.;601~609=0.1~0.9Sec.
Alarm relay time setting 03 TTT TTT
=Alarm relay time;000 (Output constantly)
001~600=1~600 Sec.
Arming delay time setting 05 TTT Base on second, range: 001~255
Alarm delay time setting 06 TTT Base on second, range: 001~255
Master card setting 07 SSSSS EEEEE SSSSS-EEEEE=00000~15999
SSSSS= starting user address; EEEEE= ending user address
Auto-open zone setting 08 MW NN HHMMhhmm
7123456H
M=AR-331-EF; W=WG Reader (0=disable; 1=enable)
NN=16 sets of auto-open zone (Range: 00~15)
HHMMhhmm=staring time to ending time
(e.g.: 08301200=08:30 to 12:00)
7123456: 7 days of week -Sun/Mon/Tue/Wed/Thu/Fri/Sat
(Input value: 0=disable; 1=enable)
H: Holiday (Input value: 0=disable; 1=enable)
Master code settings 09 PPPPPPRRRRRR PPPPPP= New master code
RRRRRR= Repeat the new master code
Suspend or delete tags Suspend:10 SSSSS EEEEE :Suspend :Delete
SSSSS= starting user address; EEEEE= ending user address
Delete: 10 SSSSS EEEEE
Recover tag or change access mode from "Card
and PIN" into "Card only"
11 SSSSS EEEEE SSSSS= starting user address; EEEEE= ending user address
Modify the user's access PIN according to the
user's address, and change the control mode to
"Card or PIN"
12 UUUUU PPPP~PPPPPPPP
UUUUU= user address;
PPPP~PPPPPPPP=4digit (default)~8-digit individual PWD
(Access mode: Card or PIN)
Arming output setting 14 TTT Base on 1ms, range:1~255, default value=10,
Input 0= Timeless
Duress code setting 15 PPPP
PPPP=4-digit PWD (0001-9999) Default value:4321
※The Duress Code 0000 means that disable Duress Function
and the default value is set as 0000 already.
Arming PWD setting 17 PPPP PPPP=4-digit PWD (0001-9999) Default value:1234
Enabling or Disabling into arming status Card+NNNN NNNN
:Arming PWD
U=Enable target unit (0=AR-331-E/EF, 1=WG Reader)
Enabling or Disabling each device into arming status. Card+NNNN U
Enabling all device into arming status. Card+NNNN
Disabling all device into arming status. Card+NNNN
Door open waiting time 18 U TTT U=Enable target unit (0=AR-331-EF , 1=WG Reader)
TTT=Door open waiting time:001~600;default value:15 sec.
Add card by presenting 19 UUUUU QQQQQ
Reader additional setting 20 0 or 1 ??? 0 or 1=Enable target unit
(0=AR-331-E/EF, 1=WG Reader)
???=Function default value
Lift control setting: multi-doors 21 UUUUU G LLLLLLLL UUUUU=user address;G=4 sets of lift control(0~3);
LLLLLLLL=8 assigned oor (F=0: Disable, 1: Enable)
Add/Delete tag by presenting (M6 only) 22 N N=0(Delete tag); N=1(Add tag)
AR-401RO16/ AR-401RO16B relay time setting 23 MMM TTT MMM=Node ID of lift controller
TTT= relay time: 000~600=1~600 sec.
Factory setting 24 0 or 1 ??? 0 or 1=Enable target unit
(0=AR-331-E/EF, 1=WG Reader)
???
:Function default value
9
9
9
QQQQQ=Card quantity(00001=Continuously inducting)
UUUUU=user address

V221226
AR-331-E/EF
SOYAL
ACCESS CONTROL SYSTEM
- 10 -
Command List (By WG Keyboard)
Function Command Exposition
Real time clock setting 25 YYMMDDHHMMSS YYMMDDHHMMSS = Year/Month/Day/Hour/Min./Sec.
Anti-pass-back (Enable user) 26 SSSSS EEEEE P SSSSS= starting user address; EEEEE= ending user address
P=0=Enable; P=1=Disable; P=2=Initial
Lift control setting: single door 27 UUUUU LL UUUUU=user address;LL:Floor number(01~64 oor)
Duress Function and Arming output setting 28 ??? Arming output and Duress function: ???= 008 (default value)
Delete all tag/Delete all tag + parameters setting 29 29 / 29 299
Same tag reading interval time 31 TTTT Base on 10ms, range from 10 to 6000
Auto ring the clock alarm schedule 32 SS HHMMTT 7123456H
SS= 16 sets auto alarm schedule, range 0~15
HHMM= HH:MM (ex. 0830: Ring bell at 08:30)
TT=Period of time to ring bell
(Base on second, range 01~99 sec.)
7123456: 7 days of week -Sun/Mon/Tue/Wed/Thu/Fri/Sat
(Input value: 0=disable; 1=enable)
H: Holiday (Input value: 0=disable; 1=enable)
Holiday Setting 35 MMDD F
MM= Month of year (01=Jan...10=Oct.)
DD= Date of month (01=1st day of month)
F= 0:Delete ; 1: Add
Enabling or Disabling into Full Access status 36 MW M=AR-331-EF ; W=WG Reader (0=disable; 1=enable)
RS485 port function setting
(Needs to be restarted after setting) 37 AB
A=0:AR401RO B=0: 9600(default value)
1:Host (default value) 1: 19200
2:LED Panel 2: 38400
3:Printer 3: 57600
Adding / Deleting Fingerprint 39 F UUUUU F=1: Adding one nger data / 2: Adding two nger data
3:Adding three nger data / 0: Delete
UUUUU=user address
Deleting All Fingerprint 39 9 99999
En/Disable Skip Finger/Tag 40 F NNNNN EEEEE
First 40*1*NNNNN*EEEEE#
Then 40*3*NNNNN*EEEEE#
Change WG bits output format 41 n n:0=WG26 ;n:1=WG34
PIN & UID Length setting 42 m n m=PIN code Length 4~8 Digit
n=UID Length 4~8 Digitn=UID Length 2~8 Digit
Compound Command Function List
Access mode: FP rst and then Tag (Default Value)
setting a pair of command
setting a pair of command
Access mode: FP only or Tag only
First 40*0*NNNNN*EEEEE#
Then 40*2*NNNNN*EEEEE#
NNNNN= starting user address;EEEEE= ending user address
20 0 ??? (Main Controller Parameter Setting)
20 1 ??? (WG Input Port Parameter Setting) ※Default Value
Function Option Value Bit Application
Entry and Exit Access is recorded on Duty Report ※0: Yes 1: No 001 0Networking
Activate close door automatically lock (Auto-Relock) ※0: Disable 1: Enable 002 1Networking/Stand-Alone
Auto Open ※0: Disable 1: Enable 004 2Networking/Stand-Alone
When Access Mode is "Card and PIN", Readers can skip pressing PIN code ※0: Disable 1: Enable 008 3Networking/Stand-Alone
Exit by Push Button 0: Disable ※1: Enable 016 4Networking/Stand-Alone
Enable force Open trigger alarm ※0: Disable 1: Enable 032 5Networking
Entry/Exit Reader ※0: Exit 1: Entry 064 6Networking
Anti-pass-back ※0: Disable 1: Enable 128 7Networking
Weighted Value Manual :
"Selection" of the function that you need is either
have 0 or 1 value.
Substract the "Value" of each Option with Selection.
Function = [0(deactive)*Value] ; [1(activate)*Value]
Add up all of the Function per Compound Command
(20 , 24 ,etc)
Step 1:
Select the "Function" that you need for each
Compound Command category (20 , 24 , etc)
Step 2:
Step 3: Step 4:

V221226
- 11 -
Fingerprint
Biometrics Device Access controller
28 ??? ※Default Value
Function Option Value Bit Application
Expiry User Access Trigger Alarm ※0: Disable 1: Enable 001 0Networking/Stand-Alone
Reset Anti-Passback on Timezone 61 ※0: Disable 1: Enable 002 1Networking/Stand-Alone
--- ---- ---- 004 2----
Duress and Arming Output function 0: Wiegand Output 1: Arming and Duress Output 008 3Networking/Stand-Alone
RS-485
Lift Control: 0 000
4-5 Networking/Stand-Alone
Host: 1 016
LED Board: 1 032
Printer: 1 048
---- ---- ---- 032 6----
---- ---- ---- 064 7----
34 ???
44 ???
Function
Function
Option
Option
Value
Value
Bit
Bit
Application
Application
※Default Value
※Default Value
※0
:
Disable
※0
:
Disable
※0
:
Disable
※0
:
Disable
※0
:
Disable
※0
:
Disable
※0
:
Disable
※0
:
Disable
※0
:
Disable
※0
:
Disable
Networking/Stand-Alone
Networking/Stand-Alone
Networking/Stand-Alone
Networking/Stand-Alone
Networking/Stand-Alone
Networking/Stand-Alone
Networking/Stand-Alone
Networking/Stand-Alone
Networking/Stand-Alone
Networking/Stand-Alone
001
002
004
008
016
001
002
004
008
016
1
:
Enable
1
:
Enable
1
:
Enable
1
:
Enable
1
:
Enable
1
:
Enable
1
:
Enable
1
:
Enable
1
:
Enable
1
:
Enable
0
1
2
3
4
0
1
2
3
4
Turn o buzzer function
Any error trigger alarm (ex: swipe invalid card)
Reserved
Turn o 13.56MHz reading function
Turn o 125kHz reading function
Access valid door relay remain locked
Master/Slave interlocking (Master open, Slave
could not open door)
Reserved
Stop card access (access only by PIN or PC
remote open door)
Reserved
※More Details:Introduction of New Function Commands for Enterprise E Controller and Home H Controller
◎Add value 032 means to activate, deduct value of 032 means to disactivate the function of swipe any tags to release door open
24 0 ??? (Main Controller Parameter Setting)
24 1 ??? (WG Input Port Parameter Setting) ※Default Value
Function Option Value Bit Application
Enable Egress Beep Sounds 0: Disable ※1: Enable 001 0Networking/Stand-Alone
---- ---- ---- 002 1----
---- ---- ---- 004 2----
Arm/Disarm Zone(Zone: 62) ※0: Enable 1: Disable 008 3Networking/Stand-Alone
Reader and controller share the same door relay
(only for WG reader)
0: Disable ※1: Enable 016 4Networking/Stand-Alone
◎Enable swipe any tags to release door open ※0: Disable 1: Enable 032 5Networking/Stand-Alone
Stop alarm by pressing push button or closing the door ※0: Disable (must swipe valid card) 1: Enable 064 6Networking/Stand-Alone
Enter auto open time zone without presenting valid card ※0: Disable (must present valid card rst) 1: Enable 128 7 Networking/Stand-Alone
This manual suits for next models
2
Other Soyal IP Access Controllers manuals

Soyal
Soyal AR-725E User manual

Soyal
Soyal AR-727iV3 User manual

Soyal
Soyal AR-721K User manual

Soyal
Soyal AR-327 User manual

Soyal
Soyal AR-363-E User manual

Soyal
Soyal AR-101-H User manual

Soyal
Soyal AR-327H User manual

Soyal
Soyal AR-725E User manual

Soyal
Soyal AR-327-E User manual

Soyal
Soyal AR-321H User manual

Soyal
Soyal AR-723-H User manual

Soyal
Soyal AR-721K User manual

Soyal
Soyal AR-888U User manual

Soyal
Soyal AR-888H User manual

Soyal
Soyal AR-888-PBI User manual

Soyal
Soyal AR-821EF User manual

Soyal
Soyal AR-723 H User manual

Soyal
Soyal AR-888-PBI-S User manual

Soyal
Soyal AR-837-EA-T User manual

Soyal
Soyal AR-721U User manual