DocID027779 Rev 1 5/8
UM1889 Set up quick data exchange between two SP1ML modules
8
2 Set up quick data exchange between two SP1ML
modules
Settings
•Connect two dongles to the PC USB port.
•Open 2 HyperTerminal sessions on the PC and connect to each dongle with associated
COM port (115200 Baud rate, local echo, CR+LF for Tx/Rx)
•By default, the module is in operation mode. In order to move it in command mode, the
“+++” escape sequence must be used.
•Using the “AT/S” command will then provide the module setting list
•Please refer to the command list provided in the SP1ML datasheet.
Figure 5. HyperTerminal
As an example, you can keep the default setting for each module, except:
Dongle/Module1
•S15 should be set to 0x00 (using HyperTerminal write ATS15=0x00)
•S16 should be set to 0x01 (using HyperTerminal write ATS16=0x01)
•Then send AT/C to store settings and ATO to move into operation mode
Dongle/Module2
•S15 should be set to 0x01 (using HyperTerminal write ATS15=0x01)
•S16 should be set to 0x00 (using HyperTerminal write ATS16=0x00)
•Then send AT/C to store settings and ATO to move into operation mode