Rev. 15.10.2018 Rev. 15.10.2018
10 11
EN
PRINCIPLE OF OPERATION
Any damage resulting from a non-conform use of the device is payable by the user!
1. airow volume adjustment knob / switch between hot and
cold air
2. airow volume indicator
3. memory buttons (saving entered parameters)
4. SMD rework gun cable
5. SMD rework gun switch on / off
6. soldering iron switch on /off
7. soldering iron smoke absorber switch on / off
8. smoke absorber pipe
9. soldering iron connection socket
10. SMD rework gun working indicator
11. SMD rework gun temperature decreasing button
12. SMD rework gun temperature increasing button
13. SMD rework working mode (AUTO / MANUAL)
14. soldering iron temperature increasing button
15. soldering iron temperature decreasing button
16. soldering iron sleep time indicator
17. SMD rework gun temperature unit (Fahrenheit or
Celsius)
18. soldering iron temperature unit (Fahrenheit or Cel-
sius)
19. soldering iron working indicator
20. soldering iron temperature display
21. SMD rework gun temperature display
BEFORE FIRST USE
Upon receipt of the goods, check the packaging for integrity and open it. If the packaging is damaged, please contact your
transport company and distributor within 3 days, and document the damages as detailed as possible. Do not turn the package
upside down! When transporting the package, please ensure that it is kept horizontal and stable. Please keep all packaging
materials (cardboard, plastic tapes and styrofoam), so that in case of a problem, the device can be sent back to the service
centre in accurate condition.
Disposing of packaging
The various items used for packaging (cardboard, plastic straps, polyurethane foam) should be conserved, so that the device
can be sent back to the service center in best conditions in case of problem!
INSTALLING THE APPLIANCE
Appliance location
The work surface where the device will be located must be suitable for the size of the appliance, please refer to the
measurements. The work surface must be levelled, dry, heat-resistant and at a tting height from the ground to enable a
proper use of the device.
The power cord connected to the appliance must be properly grounded and correspond to the technical details.
EN
OPERATION – SOLDERING STATION ONLY
1. Device must be placed on stable work table, soldering iron must be placed into the holder.
2. Fix the appropriate soldering tip and connect the device to the power source.
3. Turn on the device with the main switch placed at the back of the device, turn on the soldering iron with switch (6),
it will start to heat.
4. Temperature setting: set the desired temperature using buttons (14) and (15). Working (heating) indicator (19) will
glow. When the soldering iron reaches the set temperature, indicator will ash quickly. When the temperature drops,
the indicator turns off.
5. Soldering iron sleep time setting, „SLEEP” is blinking: simultaneously press buttons (14) and (15) for about 3 seconds,
then using these buttons set the desired sleep time (16). When the soldering iron is on, and not used (placed in the
holder), then after a set time, soldering iron will enter into sleep mode – display will show “SLP”. If the iron will be
picked up from the holder, the device will exit from the sleep mode and enter into working mode – iron will warms
up to a previously set temperature.
6. Soldering fumes absorption: soldering iron is equipped with soldering fumes absorption pipe. Absorption can be
turned on with switch (7), smoke suction power can be controlled by the knob (1). It is recommended to carry
out regular inspection and replacement of the smoke absorber lter, which is located on the front panel under the
smoke absorber tube nut (8). The absorber is designed for solder fume extraction only and may not be uses for other
purposes.
7. The device can optionally be equipped with vacuum suction pen (with air hose and suction tips) designed for
displacement of the SMD elements when soldering. In order to use this vacuum suction pen, air hose must be
connected to the smoke absorber socket (8). Suction power can be adjusted by knob (1).
8. After work, the soldering iron should be placed into the holder. Turn off the soldering station by switch (6).
9. If the device is not used for a long time, it should be completely disconnected from the power source.
OPERATION – SMD REWORK STATION ONLY
1. Device must be placed on stable work table, SMD rework gun must be placed into the holder.
2. Fix the appropriate nozzle and connect the device to the power source.
3. Turn on the device with the main switch placed at the back of the device, turn on the SMD rework gun with switch
(5), gun is ready to work.
4. Temperature setting: set the desired temperature using buttons (11) and (12). Working (heating) indicator (10) will
glow. When the SMD rework gun reaches the set temperature, indicator will ash quickly. When the temperature
drops, the indicator turns off.
5. Airow volume adjustment: set the desired airow volume with knob (1). The volume will be visible on the indicator (2).
6. Setting the automatic (AUTO) or manual (MANUAL) SMD rework gun working mode: switching between modes:
press buttons (11) and (12) simultaneously for about 3 seconds – „AUTO” or „MANUAL” ashes, set the desired
working mode by pressing buttons (11) and (12), device will enter into chosen mode after a few seconds. In manual
mode, SMD rework gun working continuously. In automatic mode, SMD rework gun turns off when placed into the
holder. Chosen “AUTO” or “MANUAL” mode will be shown on the display.
7. Cold airow setting: during normal work of the device, press the knob-button (1) to enter into cold airow mode.
Display will show “COL” and device starts cooling the SMD rework gun.
8. After work, the SMD rework gun should be placed into the holder. Turn off the SMD rework by switch (5).
9. If the device is not used for a long time, it should be completely disconnected from the power source.
CHANGING THE TEMPERATURE UNIT (CELSIUS / FAHRENHEIT):
Press buttons (12) and (14) simultaneously for about 3 seconds, the ⁰C or ⁰F will be ashing on the display. Set the desired
unit using buttons (12) and (14). Chosen unit will be shown on the display.
MEMORY BUTTONS CH1, CH2, CH3.
Device is equipped with memory buttons for saving entered data CH1, CH2, CH3.
Each button can save any conguration of all working parameters of the device: soldering iron temperature, SMD reworks
gun temperature, working mode of the SMD rework gun (AUTO or MANUAL), airow volume, soldering iron sleep time,
temperature unit. When all needed parameters are entered, press the button CH1 or CH2 or CH3 for approx. 3 seconds.
After this time, the parameters will be stored under the button which was pressed. Later, pressing this button will cause
immediately operation of the device with these stored parameters.
21 20 19 18 17
16
15
14
13
12
11
10
1
2
3