Unit fixing position and plumbing layout
17
Outline drawing (Unit:mm〔inch〕)
Area of Floor Cutout
100 x 180〔3 7/8 x 7 1/8〕
Drainage Center
Product Center
Basin Side
【Procedures for Installing the Pipe Gasket】
①Make a cut in the pipe gasket at the pipe riser point.
②Peel off the adhesive sheet on the pipe gasket and set the gas ket
on the floor.
③Cut the gasket in a circle at the cut portion on the gasket al ong with
the pipe, and then caulk the area around the pipe.
Be sure to take the necessary precautions to prepare
for and prevent possible water leaks.
●Use waterproof flooring materials.
●If the floor has an opening, cover the opening when
completing the interior finishing (waterproofing).
●Install all pipe gaskets.
The floor surface requires the following strength:
- Wooden floor : Veneer board with 30 mm thickness or more
- Mortar floor : Mortar thickness of 50 mm or more
- Special floor (stone, etc.) : The base for which the above-stated
strength is ensured should be formed in the installation are a.
Floor Surface of Tile or Glass Finish
The tiles or glass of the floor surface will break when the
bolts are embedded during installation of the shampoo
unit. If this is the case, the installation area should be
finished with materials such as plywood or mortar.
①Peel off the inner tiles or glass along the outside lines of
the installation area of the floor. The work must be done
carefully; otherwise, the peeled portion may be obvious.
②Place composite panels in the peeled-off area.
The panel surface should be higher than the surrounding
tile or glass surface (within 2 or 3 mm).
:Show the floor installation surface.
Caution for Anchor Bolt Installation
Anchor bolts should be installed so that the
screws will protrude from the bolt head by 3
to 5 mm. If the protrusion exceeds 5 mm,
the bolt head may interfere with the cover.
2〜5㎜
90〔3 9/16〕
180〔7 1/8〕
45
〔1 3/4〕
45
〔1 3/4〕
100
〔8 7/8〕
40
〔1 9/16〕
37.5
〔1 1/2〕
(360)
〔14 1/8〕
268.5
〔10 5/8〕
418
〔16 7/16〕
338.5
〔13 3/8〕
167.5〔6 5/8〕
186〔7 3/8〕
335〔13 1/4〕
372〔14 3/4〕
Φ53
〔2〕
268.5
〔10 5/8〕
329.5
〔13〕
4.5
〔1/8〕
315.5
〔12 7/16〕
Bolt Anchor Point
Water Supply(1/2” 13m/m)
Rise : 60㎜
Rise : 140㎜
Htype
Hot Water Supply
(1/2” 13m/m)
Ltype
Drainage(VU40/VP40)
Bolt Anchor Point
Bolt Anchor Point
Bolt Anchor Point Bolt Anchor Point
Bolt Anchor Point
Htype
Ltype
Rise : 160㎜
Rise : 240㎜
Htype
Ltype
Exterior Line of Cover
①Set the dedicated paper template on the floor by aligning it w ith the
rise points for the water, hot water, and drainage pipes.
②Mark the bolt anchor position of the basin main unit.
③Drill holes at the bolt anchor position of the basin main unit.
④Remove the paper template.
Request measures to prevent water leakage
under the floor and downstairs
Pipe Gasket
(Sponge Side)
Make a cut. ※Install the pipe
gasket.
※Be sure to caulk
the pipe.
CAUTION
DO NOT install riser piping where bolts or
anchors are used for fastening.
Recommended minimum distance between drainage center and wall
(furniture, etc.) is 1540〔60 5/8〕(min.1390〔54 3/4〕for standing position)
*When chair in use, the space behaind it cannot be entered.
H:When operated from standing position
L
:When operated from seated position
〔5 1/2〕
〔2 3/8〕
〔9 7/16〕
〔6 1/4〕
Rise : 60㎜
Rise : 140㎜
〔5 1/2〕
〔2 3/8〕
Recommended minimum distance between product center and wall
(furniture, etc.) is 830〔32 5/8〕(applicable when passage is 500〔19 5/8〕wide)