4. Warning Light (Included in some models, refers to the actual package)
The BLACK wire of the warning light should be connected into the “Light DC24V-” terminal (#27).
The RED wire of the warning light should be connected into the “Light DC+24V” terminal (#26).
5. Battery (optional)
The “24V+” of the battery should be wired to the “+24V BATT” terminal (#15), “24V-” should be wired to
“24V BATT-” terminal (#16). If the battery has been used with solar panel, please connect the batteries and
the solar panel &solar controller following the chapter of “Connection of the Power Supply”.
6. Photocell Beam System (PBS) (Included in some models, refers to the actual package)
Use a 2-core cable to connect the “- ~” terminal of the photocell’s emitter to the “COM” terminal (#8), the “+
~” terminal to the “+12V” terminal (#9). Also the “- ~” and “+ ~” terminals of the photocell’s receiver should
be connected to the “COM” terminal (#8) and “+12V” terminal (#9) in parallel.
Use another 2-core cable to connect the “NC” terminal of the receiver to the “INFR” terminal (#2), the “COM”
terminal to the “COM” terminal (#1).
7. Reflection Photocell Sensor (optional)
The “AC10-25V/DC12-30V” terminals of the reflection photocell sensor should be connected into the “COM”
terminal (#8) and “+12V” terminal (#9), no matter the polarity.
The “NC” terminal should be connected into the “INFR” terminal (#2).
The “COM” terminal should be connected into the “COM” terminal (#1).
8. Push Button (optional)
The push button should be wired into the “ONE” terminal (#4) and “COM” terminal (#1). No matter the
polarity. The gate operator works alternately by pressing the button (open-stop-close-stop-open).
The push button can be wired into the “STOP” terminal (#3) and “COM” terminal (#1). No matter the polarity.
The gate opener will only stop by pressing the button.
The push button can be wired into the “CLOSE” terminal (#5) and “COM” terminal (#1). No matter the
polarity. The gate opener will only close by pressing the button.
The push button can be wired into the “OPEN” terminal (#6) and “COM” terminal (#1). No matter the polarity.
The gate opener will only open by pressing the button.
9. Exit Wand (optional)
The BLACK wire of the exit wand should be connected into the “COM” terminal (#8).
The BLUE wire of the exit wand should be connected into the “LOOP” terminal (#7).
The RED wire of the exit wand should be connected into the “+12V” terminal (#9).
The GREEN wire of the exit wand should be connected into the “COM” terminal (#8).
The sensitivity adjustment board should be wired to the GREEN wire and the YELLOW wire of the wand. No
matter the polarity.
10. External Receiver (optional)
The BROWN wire of the external receiver should be connected into the “ONE” terminal (#4).
The BLACK wire of the external receiver should be connected into the “COM” terminal (#8).
The RED wire of the external receiver should be connected into the “+12V” terminal (#9).
11. Wired Keypad (24VDC) (optional)
The RED wire of the wired keypad should be connected into the “+12V” terminal (#9).