TECHNICAL DOCUMENT
INSTALL THE 15LSLANT-PROLATHE MANUAL 5CDRAWTUBE
Complete the following steps in the order listed:
Remove the Belt Guard Cover 3
Install the Drawtube 4
Re-Install the Belt Guard Cover 7
Remove the Belt Guard Cover
1. Power off the machine and the PathPilot controller.
a. Push in the Emergency Stop button on the operator box, which removes power to motion control.
b. From the PathPilot interface, select Exit.
c. Turn the Main Disconnect switch to OFF on the side of the electrical cabinet.
2. Identify the rotary encoder on the belt guard cover.
Figure 1: Rotary encoder on the belt guard cover.
3. Disconnect the power connector from the rotary encoder.
4. Identify the encoder cover below the rotary encoder.
5. Remove the encoder cover's three screws with a Phillips screwdriver, and set aside the encoder cover and
its screws
6. Identify the spindle bore cover above the rotary encoder.
Page 3
©Tormach® 2020
Specifications subject to change without notice.
tormach.com
TD10774: Installation Guide: 15L Slant-PRO Lathe Manual 5C Drawtube (0920A)