manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Viavi
  6. •
  7. Test Equipment
  8. •
  9. Viavi OneAdvisor 1000 User manual

Viavi OneAdvisor 1000 User manual

VIAVI//Public
OneAdvisor 1000 High-Speed Network Testing Platform
OneAdvisor 1000 High-Speed Network Testing Platform
QUICK CARD
DS3 Bit Error Rate Testing (BERT)
This quick card describes how to configure and run a DS3 Bit Error Rate Test to a hard
loop, or another similarly configured VIAVI Test Instrument.
•OneAdvisor 1000 equipped with the following:
o100G Transport Module
oBERT software release V30.1.0 or greater
oC5DS3STS1 test option: DS3/STS-1 Electrical
oC5DUALPORT test option
•Two (2) mini-BNC to BNC adapters (CB-MINITOBNCQTY1)
•One of the following DS3 cable sets to connect the
T-BERD 5800 DS3 Port(s) to the line under test:
oTwo (2) BNC to BNC cables (CB-30662)
oTwo (2) BNC to WECO 440Acables (CB-015837) Figure 1: Equipment Requirements
LAUNCH TEST
1. Press the Power button to turn on the
OneAdvisor.
2. Press the 100G Module Test icon
at the top of the screen.
3. Tap the Power button and click
to launch the 100G Module.
4. Using the Select Test menu, Quick Launch
menu, or Job Manager, launch the
DS1/DS3►DS3►DS3 BERT►Terminate
test.
Figure 2: Launch 100G Module
Figure 3: Launch Test
VIAVI//Public
OneAdvisor 1000 High-Speed Network Testing Platform
OneAdvisor 1000 High-Speed Network Testing Platform
QUICK CARD
2
•The following Information is needed to
configure the test:
•DS3 Framing (C-BIT or M13)
•Clock Source (Internal or Recovered)
•Test Patterns(s)
•BER Pass/Fail Threshold
1. Tap to open the Tools Panel and
select .
2. Press to continue.
3. Press the Setup soft key on the top right
side of the screen.
4. Select the indicated folders and configure
your test as follows. Leave all other values at
default, unless specified in the work order.
5. Press the Results soft key to view the
Test Results screen.
Figure 4: Work Order
CONFIGURE TEST
Folder
Option
Value(s)
Interface
Rx Input
Term
Clock Source
If unknown,
select “Internal”
Clock Offset
0 ppm
LBO
0 dB
Framing
Framing
If unknown,
select “C
-BIT”
Pattern
Pattern Mode
ANSI
Pattern
2^23
-1 ANSI
Figure 5: Reset Test to Defaults
Figure 8: Setup, Pattern
Figure 7: Setup, Framing
Figure 6: Setup, Interface
VIAVI//Public
OneAdvisor 1000 High-Speed Network Testing Platform
OneAdvisor 1000 High-Speed Network Testing Platform
QUICK CARD
3
RUN TEST
1. Using drop-down menus , select
“Interface/Signal” for the right results display.
2. Press the Restart soft key .
3. Verify the following:
►Summary LED is green.
►Signal Present LED is green.
If the LED is red, check your cables.
Tx and Rx may be reversed.
►Frame Sync LED is green.
►RX Frequency (Hz)
= 44736000 +/- 895 Hz.
4. Using drop-down menus , select
“Payload/BERT” for the right results display.
5. Allow the test to run for desired duration and
verify the following:
►Pattern Sync LED is green.
►Bit/TSE Error Rate result does not
exceed your required threshold.
(0.00E+00 if pass/fail threshold unknown)
Figure 10: Results, Interface/Signal
Figure 9: Mini-BNC Connectors
CONNECT TO LINE UNDER TEST
•The OneAdvisor 100G Transport
Module has mini-BNC ports for
DS3 testing.
•CB-MINITOBNCQTY1 adapters
are required to adapt to a
standard BNC connector.
•You may use BNC to BNC or
BNC to WECO cables to connect
the adapter to the line under test.
Figure 11: Results, Payload BERT
VIAVI//Public
OneAdvisor 1000 High-Speed Network Testing Platform
OneAdvisor 1000 High-Speed Network Testing Platform
QUICK CARD
© 2022 VIAVI Solutions, Inc,
Product specifications and descriptions in this
document are subject to change without notice.
Patented as described at viavisolutions.com/patents
Contact Us
To reach the VIAVI office nearest you,
visit viavisolutions.com/contact
+1 844 GO VIAVI
(+1 844 468-4284)
CREATE REPORT
6. In the OneAdvisor’s Quick Config menu,
change “Pattern” to the next value in the test
plan.
7. Press the Restart soft key to reset results.
8. Allow test to run for desired duration and verify
the following:
►Pattern Sync LED is green.
►Bit/TSE Error Rate does not exceed
your required threshold.
(0.00E+00 if pass/fail threshold unknown)
9. Repeat steps 6 through 8 for all Patterns in the
test plan. Patterns may include:
►Delay: Measures Round Trip Delay (RTD)
instead of Bit Errors (RTD values are shown
instead of BER in the “Payload/BERT”
results display)
►Others
Figure 12: Results, Quick Config
Figure 13: Results, Delay
1. Tap to open the Reports Panel and
select . .
2. Tap .
3. A report will be saved to the OneAdvisor 1000
100G Module’s /bert/reports folder.
Figure 14: Create Report

Other Viavi Test Equipment manuals

Viavi T-BERD MTS 5800 Parts list manual

Viavi

Viavi T-BERD MTS 5800 Parts list manual

Viavi 7200 Series Owner's manual

Viavi

Viavi 7200 Series Owner's manual

Viavi T-BERD/MTS 5800 User manual

Viavi

Viavi T-BERD/MTS 5800 User manual

Viavi OneExpert ONX CATV 620 User manual

Viavi

Viavi OneExpert ONX CATV 620 User manual

Viavi FCOMP/-PRO T-BERD/MTS-2000V2 User manual

Viavi

Viavi FCOMP/-PRO T-BERD/MTS-2000V2 User manual

Viavi 8000 V2 Platform User manual

Viavi

Viavi 8000 V2 Platform User manual

Viavi HST-3000 User manual

Viavi

Viavi HST-3000 User manual

Viavi HST-3000 Parts list manual

Viavi

Viavi HST-3000 Parts list manual

Viavi T-BERD/MTS-2000 Parts list manual

Viavi

Viavi T-BERD/MTS-2000 Parts list manual

Viavi AVX-10K User manual

Viavi

Viavi AVX-10K User manual

Viavi T-BERD/MTS-580 Installation guide

Viavi

Viavi T-BERD/MTS-580 Installation guide

Viavi OSA-4100 User manual

Viavi

Viavi OSA-4100 User manual

Viavi OneExpert DSL ONX-580 User manual

Viavi

Viavi OneExpert DSL ONX-580 User manual

Viavi T-BERD/MTS 4000 V2 Parts list manual

Viavi

Viavi T-BERD/MTS 4000 V2 Parts list manual

Viavi ComXpert CX100 User manual

Viavi

Viavi ComXpert CX100 User manual

Viavi 3900 Series Owner's manual

Viavi

Viavi 3900 Series Owner's manual

Viavi SmartClass Fiber OLS-85 User manual

Viavi

Viavi SmartClass Fiber OLS-85 User manual

Viavi SmartPocket OLP-39G User manual

Viavi

Viavi SmartPocket OLP-39G User manual

Viavi CT-X User manual

Viavi

Viavi CT-X User manual

Viavi OLA-54 User manual

Viavi

Viavi OLA-54 User manual

Viavi T-BERD MTS 5800 User manual

Viavi

Viavi T-BERD MTS 5800 User manual

Viavi SmartOTDR Parts list manual

Viavi

Viavi SmartOTDR Parts list manual

Viavi MTS 2000 Parts list manual

Viavi

Viavi MTS 2000 Parts list manual

Viavi IFR 6015 User manual

Viavi

Viavi IFR 6015 User manual

Popular Test Equipment manuals by other brands

Ambit P.F. Series instruction manual

Ambit

Ambit P.F. Series instruction manual

Megger BMM500 Series user guide

Megger

Megger BMM500 Series user guide

RJG Lynx Sensor Tester operating instructions

RJG

RJG Lynx Sensor Tester operating instructions

Mark-10 TT02 Series user guide

Mark-10

Mark-10 TT02 Series user guide

Martel 3001 Operator's manual

Martel

Martel 3001 Operator's manual

ElproSys DiagProg4 instruction manual

ElproSys

ElproSys DiagProg4 instruction manual

Redtech TRAILERteck T05 user manual

Redtech

Redtech TRAILERteck T05 user manual

Venmar AVS Constructo 1.0 HRV user guide

Venmar

Venmar AVS Constructo 1.0 HRV user guide

Test Instrument Solutions SafetyPAT operating manual

Test Instrument Solutions

Test Instrument Solutions SafetyPAT operating manual

Hanna Instruments HI 38078 instruction manual

Hanna Instruments

Hanna Instruments HI 38078 instruction manual

Kistler 5495C Series instruction manual

Kistler

Kistler 5495C Series instruction manual

Waygate Technologies DM5E Basic quick start guide

Waygate Technologies

Waygate Technologies DM5E Basic quick start guide

StoneL DeviceNet CK464002A manual

StoneL

StoneL DeviceNet CK464002A manual

Seica RAPID 220 Site preparation guide

Seica

Seica RAPID 220 Site preparation guide

Kingfisher KI7400 Series Training manual

Kingfisher

Kingfisher KI7400 Series Training manual

Kurth Electronic CCTS-03 operating manual

Kurth Electronic

Kurth Electronic CCTS-03 operating manual

SMART KANAAD SBT XTREME 3G Series user manual

SMART

SMART KANAAD SBT XTREME 3G Series user manual

Agilent Technologies BERT Serial Getting started

Agilent Technologies

Agilent Technologies BERT Serial Getting started

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.