Viavi OneAdvisor 800 400G Module User manual

VIAVI//Public
OneAdvisor High-Speed Network Testing Platforms
OneAdvisor High-Speed Network Testing Platforms
QUICK CARD
https://www.viavisolutions.com/en-us/product-family/oneadvisor
Ethernet Y.1564 Layer 2 Traffic
This quick card describes how to set up the OneAdvisor 800 400G Module or OneAdvisor 1000 400G
Module to run an ITU Y.1564 Layer 2 Traffic Test for Metro Ethernet service activation.
LAUNCH TEST
1. Press the Power button to turn on the
OneAdvisor.
2. Press the 400G Module icon
at the top of the screen.
3. Using the Select Test menu, Quick Launch
menu, or Job Manager, launch the Ethernet
Layer 2 Traffic test for the desired data rate on
the desired port (P1 or P2). For example:
Ethernet ►400GigE Optical
►Y.1564 SAMComplete ►Layer 2 Traffic
►P2 Terminate.
4. Tap the button next to “Start a New
Configuration (reset to defaults)”
Figure 2: Launch Test
Figure 3: Start a New Configuration
Figure 1: Equipment Requirements
•OneAdvisor 800 or OneAdvisor 1000 equipped with the following:
o400G Transport Module
oTransport software release V4.0.0 or greater
oSoftware option for data rate to be tested:
✓CA10M1GE test option for 10/100/1000M
Copper or 1 Gigabit Optical Ethernet
✓CA10GELAN test option for 10 Gigabit Ethernet
✓CA25GE test option for 25 Gigabit Ethernet
✓CA40GE test option for 40 Gigabit Ethernet
✓CA50GE test option for 50 Gigabit Ethernet
✓CA100GE test option for 100 Gigabit Ethernet
✓CA200GE test option for 200 Gigabit Ethernet
✓CA400GE test option for 400 Gigabit Ethernet
•Optical Transceiver supporting the Ethernet data rate
to be tested (SFP, QSFP, or OSFP)
•Cables to match the optical transceiver and the line under test
•Fiber optic inspection microscope (P5000i or FiberChek Probe)
•Fiber optic cleaning supplies
VIAVI//Public
OneAdvisor High-Speed Network Testing Platforms
OneAdvisor High-Speed Network Testing Platforms
QUICK CARD
2
►The following Information is needed to
configure the test:
•Frame Size
•VLAN ID, if VLAN tagging is used.
•Committed Information Rate (CIR)
•Pass/Fail Threshold for Frame Loss
Ratio, Delay, and Delay Variation (Jitter)
1. Tap the button to display the
Local Network Settings 1 screen.
►Select the Frame Size you wish to
generate.
2. Tap to display the
Local Network Settings 2 screen.
►If you are testing a VLAN, set
Encapsulation to VLAN and enter
the VLAN ID.
CONFIGURE TEST
Figure 4: Work Order
Figure 6: Local Network Settings 2
Figure 5: Local Network Settings 1
VIAVI//Public
OneAdvisor High-Speed Network Testing Platforms
OneAdvisor High-Speed Network Testing Platforms
QUICK CARD
3
4. Tap to display the SLA Throughput
screen.
►Enter the Committed Information Rate
(CIR).
►If the you are testing at full line rate or if
traffic is not being policed, uncheck the
Policing checkbox.
5. Tap the button twice to display the
SLA Performance screen.
►Enter the Frame Loss Ratio, Frame Delay,
and Delay Variation pass/fail criteria.
6. Tap the button 5 times to display the
J-QuickCheck screen. Figure 8: SLA Performance
Figure 9: J-QuickCheck
Figure 7: SLA Throughput
VIAVI//Public
OneAdvisor High-Speed Network Testing Platforms
OneAdvisor High-Speed Network Testing Platforms
QUICK CARD
4
►For Optical Interfaces:
1. Use the VIAVI P5000i or FiberChek Probe
microscope to inspect both sides of every
connection being used (SFP, attenuators,
patch cables, bulkheads)
oFocus the fiber on the screen.
oIf it appears dirty, clean the fiber end-face
and re-inspect.
oIf it appears clean, run the inspection test.
oIf it fails, clean the fiber and re-run
inspection test. Repeat until it passes.
2. Insert desired Optical Transceiver into the
Port 1 SFP or QSFP slot on the top of the
OneAdvisor.
3. If necessary, insert optical attenuators into
the SFP/QSFP TX and/or RX ports.
4. Connect the SFP/QSFP to the port under
test using a jumper cable compatible with
the line under test.
►For Copper 10/100/1000BASE-T interfaces:
1. Insert Copper SFP into the Port 1 SFP or
slot on the top of the OneAdvisor.
2. Connect the copper SFP to
the port under test using CAT 5E or better
cable.
►Verify that Local Port status UP and Full
Duplex (FD)
►Tap the button.
►Verify that the Remote Loop is recognized.
►Tap the button to display the
Run Y.1564 Tests screen.
Figure 11: Local Port status
Figure 10: Inspect Before You Connect
CONNECT TO LINE UNDER TEST AND LOOP BACK DEVICE
Figure 12: Run J-QuickCheck
VIAVI//Public
OneAdvisor High-Speed Network Testing Platforms
OneAdvisor High-Speed Network Testing Platforms
QUICK CARD
© 2023 VIAVI Solutions, Inc,
Product specifications and descriptions in this
document are subject to change without notice.
Patented as described at viavisolutions.com/patents
Contact Us
To reach the VIAVI office nearest you,
visit viavisolutions.com/contact
+1 844 GO VIAVI
(+1 844 468-4284)
1. Tap the button three times to
display the Report screen.
2. Tap .
3. Tap buttons three times to
close the report and exit the Y.1564 test.
RUN TEST
1. Tap the button.
2. Wait for the test to complete and verify that
all tests pass or complete as indicated by a
green or blue checkmark.
CREATE REPORT
Figure 13: Run Y.1564 Tests
Figure 14: Create Report
Figure 15: Exit

This manual suits for next models

1

Other Viavi Test Equipment manuals

Viavi ATC-5000NG User manual

Viavi

Viavi ATC-5000NG User manual

Viavi OneAdvisor-1000 User manual

Viavi

Viavi OneAdvisor-1000 User manual

Viavi 3900 Series User manual

Viavi

Viavi 3900 Series User manual

Viavi T-BERD/MTS 8000 Parts list manual

Viavi

Viavi T-BERD/MTS 8000 Parts list manual

Viavi OneAdvisor 1000 User manual

Viavi

Viavi OneAdvisor 1000 User manual

Viavi HST-3000 User manual

Viavi

Viavi HST-3000 User manual

Viavi OneAdvisor ONA-800 Technical manual

Viavi

Viavi OneAdvisor ONA-800 Technical manual

Viavi SmartClass Fiber MPOLx Parts list manual

Viavi

Viavi SmartClass Fiber MPOLx Parts list manual

Viavi T-BERD 6000A V2 Parts list manual

Viavi

Viavi T-BERD 6000A V2 Parts list manual

Viavi T-BERD/MTS-2000 Parts list manual

Viavi

Viavi T-BERD/MTS-2000 Parts list manual

Viavi T-BERD 5800 User manual

Viavi

Viavi T-BERD 5800 User manual

Viavi 3900 Series Owner's manual

Viavi

Viavi 3900 Series Owner's manual

Viavi HST-3000 Parts list manual

Viavi

Viavi HST-3000 Parts list manual

Viavi T-BERD/MTS 8000 User manual

Viavi

Viavi T-BERD/MTS 8000 User manual

Viavi IFR 6000 User manual

Viavi

Viavi IFR 6000 User manual

Viavi OSA-4100 User manual

Viavi

Viavi OSA-4100 User manual

Viavi 8000 V2 Platform Parts list manual

Viavi

Viavi 8000 V2 Platform Parts list manual

Viavi HST-3000 User manual

Viavi

Viavi HST-3000 User manual

Viavi OneAdvisor 1000 User manual

Viavi

Viavi OneAdvisor 1000 User manual

Viavi T-BERD 5800 Parts list manual

Viavi

Viavi T-BERD 5800 Parts list manual

Viavi T-BERD/MTS-5800 Parts list manual

Viavi

Viavi T-BERD/MTS-5800 Parts list manual

Viavi OneExpert DSL User manual

Viavi

Viavi OneExpert DSL User manual

Viavi 7200 Series User manual

Viavi

Viavi 7200 Series User manual

Viavi ALT-8000 Parts list manual

Viavi

Viavi ALT-8000 Parts list manual

Popular Test Equipment manuals by other brands

Astronics Trig-Tek 346B user manual

Astronics

Astronics Trig-Tek 346B user manual

Megger DELTA 4000 Reference manual

Megger

Megger DELTA 4000 Reference manual

NoiseKen LSS-720B2 instruction manual

NoiseKen

NoiseKen LSS-720B2 instruction manual

Psiber CableMaster 600 quick start guide

Psiber

Psiber CableMaster 600 quick start guide

T+M Time TT100 instruction manual

T+M

T+M Time TT100 instruction manual

Lutron Electronics RT-606 Operation manual

Lutron Electronics

Lutron Electronics RT-606 Operation manual

YATO YT-7300 quick guide

YATO

YATO YT-7300 quick guide

WHALETEQ CMRR 3.0E user manual

WHALETEQ

WHALETEQ CMRR 3.0E user manual

Hawkeye Mfg V3 user manual

Hawkeye Mfg

Hawkeye Mfg V3 user manual

3M FT-10 Guide to using

3M

3M FT-10 Guide to using

UIM UIM-90 user manual

UIM

UIM UIM-90 user manual

HOGERT HT8G430 user manual

HOGERT

HOGERT HT8G430 user manual

Keysight Technologies InfiniiVision 1000 X-Series Service guide

Keysight Technologies

Keysight Technologies InfiniiVision 1000 X-Series Service guide

STEP SYSTEMS pH Soil instruction manual

STEP SYSTEMS

STEP SYSTEMS pH Soil instruction manual

Teledyne T700 user manual

Teledyne

Teledyne T700 user manual

Inficon TC1000 operating manual

Inficon

Inficon TC1000 operating manual

Greenlee 6700 instruction manual

Greenlee

Greenlee 6700 instruction manual

Associated Research HYAMP 3240 Service manual

Associated Research

Associated Research HYAMP 3240 Service manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.