Visionis VIS-3024 User manual

Fingerprint Reader for
Access Control for Single Door
User Manual
VIS-3024
www.visionistech.com

1
1. Introduction
2. Feature
The VIS-3024 is a new generation of multi-functional standalone access control. It
adopts new ARM core 32-bit microprocessor design, which is powerful, stable and
reliable. It contains reader mode and standalone access control mode etc..
It’s widely applied to different occasions, such as office, residential communities,
villa etc..
- Read 125KHz EM Card and HID Card
- Operate by infrared remote
- Contain reader mode, the transmission format could be adjusted by user.
- Support multi access ways: Card+Fingerprint, multi cards or multi fingerprint
- Support admin add card / admin add fingerprint & admin delete card / admin delete
fingerprint
- 10,000 card users and 600 fingerprint users.
- Unlock signal : Relay NO/NC/COM output
3. Technical Specifications
Feature
Operating Voltage
Standby Current ≤ 35mA
Operating Current ≤100mA
Operating Temperature -20°C ~ 60°C (-4°F ~ 140°F)
Operating Humidity
Electric lock signal relay contact current
0%~95%
≤1A
Alarm signal MOS tube output ≤1A
Unlocking time 0~300s adjustable
DC 12-24V
Description

5. Wiring
4. Installation
No. Color Function Description
1 Green D0 Wiegand input (Wiegand output as reader mode)
2 White D1 Wiegand input (Wiegand output as reader mode)
3 Yellow OPEN/ BEEP Exit button input end (Beeper input as reader mode)
4 Red +12V Positive power supply
5 Black GND Negative power supply
6 Blue NO Relay NO end
7 Purple COM Relay COM end
8 Orange NC Relay NC end
- Remove the back cover from the keypad using the supplied special screw driver
- Drill 2 holes on the wall for the self-tapping screws and hole for the cable
- Put the supplied rubber bungs to into the two holes
- Fix the back cover firmly on the wall with 2 self tapping screws
- Thread the cable through the cable hole
- Attach the keypad to the back cover. (as following illustration)
2

6. Connection Diagram
3
6.1. Common Power Supply
Note: The door contact and alarm function are optional
Note: The door contact and alarm function
are optional
6.2. Special Power Supply

4
6.3. Reader Mode
6.4. Connection for Lock and Button
Power
Supply
Electromagnetic Lock
Exit Button
COM
NO
(COM)
PURPLE WIRE
(NC)
ORANGE WIRE
(OPEN)
YELLOW WIRE
FROM KEYPAD/READER
FROM KEYPAD/READER
FROM KEYPAD/READER
Fingerprint/
Card Reader

5
6.5. Connection for Lock, Button and PIR
6.6. Connection for Lock, Button, and Receiver
Power Supply
Electromagnetic Lock
Exit
Button
Power Supply
COM
NO
NC
PIR
COM
YELLOW
WIRE
ORANGE WIRE
PURPLE WIRE
FROM KEYPAD/
READER
Power Supply
Electromagnetic Lock
Exit
Button
Power
Supply
COM
COM
NO
NO
NC
YELLOW WIRE FROM KEYPAD/READER
Receiver
ORANGE WIRE FROM
KEYPAD/READER
PURPLE WIRE FROM
KEYPAD/READER
Fingerprint/
Card Reader
Fingerprint/
Card Reader

6.7. Connection to Access Control Panel
W1
W0
12V
GND
7. Sound and Light Indication
Operation Status
Stand by
Operation successful
Operation failed
Admin card enter programming
Admin card exit programming
Press digital key
Press * key
Read card under fingerprint + code mode
On process of reading multi user card
Enter programming mode
Enter setting status
Unlocking
Buzzer alarm
Beep-Beep-Beep
Beep-Beep
Beep—
Beep
Beep—
Alarm
Green
Red indicator flash
slowly
Red indicator flash
slowly
Red indicator flash
slowly
Red indicator flash
slowly
Green
Orange
Red
Beep—
BuzzerLED Indicator
6

7
8. Admin Menu
8.1 Standalone Mode Settings
Device Management
Add Users
Enter
programming
Menu Operation steps Description Default
value
Press * Admin code #
(Default admin code
is "999999")
New admin code #
new admin code # Change admin code 999999
10001# Read card
/ Press a fingerprint twice *
Set add card or add
fingerprint
10002# Read card
/ Input a fingerprint twice *
Set delete card or delete
fingerprint
10001# * Delete add card or add
fingerprint
10002# * Delete delete card or
delete fingerprint
11 #
Standalone access control
mode
12 #
Relay toggle mode
13 #
Reader mode
( 26-58 ) #
Wiegand output:26-58 bits
8 #
WIFI matching
Optional
8
3
2
1
0
11
Enter
programming Menu Operation steps Description Default
value
1
Read card / Input a
fingerprint twice... *
Press 8 or 10 digits card
number # … *
Press ID number # read
card / Input a fingerprint
twice … *
Press ID number #
press 8 or 10 digits card
number # … *
Add card users by card
number
Add card users or fingerprint
users by specific ID number
Add card users by specific
ID number and card number
Add card users or fingerprint
users continuously “…”
means
repeating
the
previous
operation,
Press *
key to exit.
Press *
Admin
code #
(Default
admin code
is "999999")

8
Access Ways
Enter
programming Menu Operation steps Description Default
value
Press * Admin
code #
(Default admin
code is
"999999")
3
Delete Users
Enter
programming Menu Operation steps Description Default
value
2
Read card / Input a
fingerprint once... *
Press 8 or 10 digits card
number # … *
Press ID number # … *
0000#
0#
1#
( 2-10 ) #
Entry by card or fingerprint
Entry by card + fingerprint
Entry by multi-card /
multi-fingerprint
Delete card users by card
number
Delete users by ID number
Delete ALL users
Delete card users by reading
card / Delete fingerprint
users by inputting fingerprint “…” means
repeating
the
previous
operation,
Press *
key to exit.
Press *
Admin
code #
(Default
admin code
is "999999")
0
Advanced Settings
Enter
programming Menu Operation steps Description Default
value
Press * Admin
code #
(Default admin
code is
"999999")
4
5
(0-300) #
(0-99) #
Read user card, input
the first fingerprint
twice, input the second
fingerprint twice...*
Press ID number #
press 8 or 10 digits
card number # input
card quantity #
0#
Door opening time range:
0-300S 0 equals to 50mS
Alarming time range: 0-99 min.
Match fingerprints to a card
( Maximum 2 fingerprints )
Add conductive number card
Normal working mode
5
6
7
8
0
0

9
Advanced Settings
Enter
programming Menu Operation steps Description Default
value
Press * Admin
code #
(Default admin
code is
"999999")
81#
2#
3#
4#
5#
6#
The external alarm and built-in
buzzer will work if wrong
operations are over 5 times.
The device will be locked out
for 10 min if wrong operations
are over 5 times.
Disable light indicator
Enable light indicator
Disable buzzer
Enable buzzer
5
0
4
6
8.2 Reader Mode Settings
Enter
programming Menu Operation steps Description Default
value
0New admin code #
Repeat new admin
code #
10001# Read card / Input
a fingerprint twice *
10002# Read card / Input
a fingerprint twice *
10001# *
Set admin add card or admin
add fingerprint
Set admin delete card or
admin delete fingerprint
Delete admin add card or
admin add fingerprint
10002# * Delete admin delete card or
admin delete fingerprint
Input a fingerprint
twice... *
Add fingerprint user
continuously
Press ID number # Input
a fingerprint twice … *
Add fingerprint users by
specific ID number
Input a fingerprint
once... *
Delete fingerprint user
0000 # Delete ALL users
( 26-58 ) # Wiegand output: 26-58 bits
(0-99) # Alarming time range: 0-99 min.
( 0-255 ) # Device number
Change admin code 999999
Press *
Admin code
#
(Default
admin code
is "999999")
1
2
1
“…”
means
repeating
the
previous
operation,
Press *
key to
exit.
2
3
5
90
0
26

10
10.1 Remove Alarm
10. Other Operation
9. Admin Card / Admin Code Operation
9.1 Add Users
Read admin add card / Input admin add fingerprint , Read the 1st user card / Input the first
fingerprint twice Read the 2nd user card / Input the 2nd fingerprint twice …,Read admin
add card / Input admin add fingerprint
Note: The admin add card / admin add fingerprint is used for adding card / fingerprint
users continuously and quickly. When you read the admin add card / input the add
fingerprint at the first time, you will hear short "BEEP" sounds twice and the indicator
light turns orange, it means you have entered into add user programming, when you
read the admin add card / input the add fingerprint at the second time, you will hear
long "BEEP" sound once and the indicator light turns red, it means you have exited
the add user programming.
Note: The admin delete card / admin delete fingerprint is used for deleting card /
fingerprint users continuously and quickly. When you read the admin delete card /
admin delete fingerprint at the first time, you will hear short "BEEP" sounds twice
and the indicator light turns orange, it means you have entered into delete user
programming, when you read the admin delete card / admin delete fingerprint at the
second time, you will hear long "BEEP" sound once, the indicator light turns red, it
means you have exited the delete user programming.
Note: When the alarm is activated, user can remove the alarm by reading a valid
card or inputting valid fingerprint or pressing valid admin code.
10.2 Reset to Factory Default
Users can reset to the factory default when the admin code is forgotten, or the default
settings have been modified disorderedly, operations as below:
Power off, press and hold the exit button continuously, power on, release the exit button
until hearing beep sound twice, the admin code has been reset to 999999, factory default
settings are successful.
Note: Registered user data won’t be deleted when reset to factory default.
9.2 Delete Card
Read admin delete card / Input admin delete fingerprint , Read the 1st user card / Input
the 1st fingerprint once Read the 2nd user card / input the 2nd fingerprint once… , Read
admin delete card
Read valid card or or Press admin code #
Input valid fingerprint
Table of contents
Other Visionis IP Access Controllers manuals

Visionis
Visionis VIS-7101 User manual

Visionis
Visionis VIS-3103 User manual

Visionis
Visionis VIS-3013 User manual

Visionis
Visionis VS-AXESS-4D-ETL-PCB User manual

Visionis
Visionis VS-AXESS-4DLX User manual

Visionis
Visionis VS-AXESS-2D-ETL-PCB User manual

Visionis
Visionis VIS-3100 User manual

Visionis
Visionis VIS-3003 User manual

Visionis
Visionis VS-AXESS-1ETL User manual

Visionis
Visionis VIS-3009 User manual