Vitek VT-1892 B User manual

1
VT-1892 B/R
3
7
11
16
20
Vacuum cleaner
Пылесос
VT-1892.indd 1 03.12.2015 17:47:49

VT-1892.indd 2 03.12.2015 17:47:49

3
E N G L I S H
VACUUM CLEANER VT-1892 B/R
This unit is intended for room cleaning.
DESCRIPTION
1. Floor/carpet brush
2. «Carpet/floor» switch
3. Telescopic pipe clamp
4. Telescopic extension pipe
5. Flexible hose handle
6. Flexible hose
7. Outlet filter grid
8. Outlet filter grid lock
9. ON/OFF button
10. Suction power control
11. Power cord winding button
12. Outlet HEPA filter
13. Full dustbag indicator
14. Flexible hose ending
15. Flexible hose ending clamps
16. Dustbag compartment lid
17. Dustbag compartment lid clamp
18. Carrying handle
19. Brush storage
20. Inlet filter holders
21. Inlet filter
22. Dustbag clamps
23. Dustbag holder
24. Combined brush
25. Air inlet
26. Dustbag
RECOMMENDATIONS
ON SAFETY MEASURES
Read this instruction manual carefully before
using the unit and keep it for the whole operation
period. Use the unit for intended purposes only,
as specified in this manual. Mishandling the unit
can lead to its breakage and cause harm to the
user or damage to his/her property.
ATTENTION!
For additional protection you can install a residual
current device with nominal operation current not
exceeding 30 mA into the mains; contact a spe-
cialist for installation.
WARNING
To avoid the risk of fire, electric shock and to
prevent injury, observe the following safety mea-
sures.
•Before connecting the unit to the mains, make
sure that the voltage specified on the unit cor-
responds to your home mains voltage.
•To avoid fire, do not use adapters for connect-
ing the unit to the mains.
•Do not leave the plugged in vacuum cleaner
unattended. Always unplug the vacuum
cleaner if it is not being used, before chang-
ing attachments or before maintenance.
•To prevent the risk of electric shock, do not
use the vacuum cleaner outdoors, do not use
it for collecting water or other liquids (do not
use the vacuum cleaner on wet surfaces).
•Carry the vacuum cleaner holding it by the
carrying handle only.
•Do not use the power cord for carrying the
vacuum cleaner, do not close the door if the
power cord runs through the doorway, do not
let the power cord come in contact with sharp
corners or edges of furniture, and with hot sur-
faces. Do not run over the power cord with the
vacuum cleaner while room cleaning as this
can damage it. Always first switch the vacuum
cleaner off with the ON/OFF button and only
after that take the power plug out of the mains
socket.
•When unplugging the unit, pull the plug but
not cord.
•Do not touch the plug or the body of the vac-
uum cleaner with wet hands.
•Hold the winding cord with hand to avoid the
plug hitting against the floor.
•Do not cover the unit outlet with any objects.
•Do not switch the unit on if any of its openings
are blocked.
•Keep hair, free hanging clothes, fingers and
other parts of your body away from the vac-
uum cleaner air inlets.
•Be especially cautious while cleaning the stair
landings.
•Do not use the vacuum cleaner for collect-
ing such highly inflammable liquids as gaso-
line and solvents, do not use the unit in places
where such liquids are stored.
•Do not use the vacuum cleaner for collecting
water and other liquids, burning or smoking cig-
arettes, matches, cinders as well as fine dust,
for example, of plaster, concrete, flour or ashes.
•Do not use the vacuum cleaner if:
– the dustbag is not installed or installed
improperly;
– the inlet and outlet filters are not installed.
•Do not immerse the unit body into water or
other liquids.
•Use only the accessories and attachments
supplied.
VT-1892.indd 3 03.12.2015 17:47:49

4
ENGLISH
•Clean the vacuum cleaner regularly.
•Keep the vacuum cleaner in a dry cool place.
•Do not use the vacuum cleaner to clean pets.
•Close supervision is necessary when children
under 8 years of age or disabled persons are
near the operating unit.
•This unit is not intended for usage by children
under 8 years of age. Place the unit out of
reach of children under 8 years of age during
the operation and cooling down.
•This unit is not intended for usage by people
(including children over 8) with physical, neural
and mental disorders or with insufficient expe-
rience or knowledge. Such persons may use
the unit only if they are under supervision of a
person who is responsible for their safety and
if they are given all the necessary and under-
standable instructions concerning the safe
usage of the unit and information about dan-
ger that can be caused by its improper usage.
•Do not leave children unattended to prevent
using the unit as a toy.
•For children safety reasons do not leave poly-
ethylene bags, used as packaging, unat-
tended.
Attention! Do not allow children to play with
polyethylene bags or packaging film. Danger of
suffocation!
•Transport the unit in the original package only.
•Regularly check the power plug and power
cord integrity for damages.
•Never use the unit if the power cord or the power
plug is damaged, if the unit works improperly,
after it was dropped or in case of leakage.
•Do not attempt to repair the unit. Do not disas-
semble the unit by yourself, if any malfunction
is detected or after it was dropped, unplug
the unit and apply to any authorized service
center from the contact address list given in
the warranty certificate and on the website
www.vitek.ru .
•Keep the unit out of reach of children and dis-
abled persons.
THE UNIT IS INTENDED FOR HOUSEHOLD
USAGE ONLY
Safety measures
•Do not use the vacuum cleaner near hot sur-
faces, ashtrays and in places where inflam-
mable liquids are stored.
•Take sharp objects away from the floor before
cleaning to prevent unit damage.
•If the suction power of the vacuum cleaner
decreases rapidly while cleaning, switch the
vacuum cleaner off immediately and check
the telescopic pipe and the flexible hose for
obstruction. Switch the vacuum cleaner off,
then unplug it, remove the obstruction and
only after that continue cleaning.
ASSEMBLING THE VACUUM CLEANER
After unit transportation or storage at low
temperature keep it for at least three hours
at room temperature before switching on.
– Unpack the unit completely and remove any
stickers that can prevent unit operation.
– Check the unit for damages; do not use it in
case of damages.
– Before switching the unit on, make sure that
your home mains voltage corresponds to the
unit operating voltage.
Note: Always switch the vacuum cleaner off and
take the power plug out of the socket before
replacing the brush attachments and before
replacing the dustbag (26).
Attaching and removing the flexible hose
•Insert the flexible hose ending (14) into the
air inlet (25).
•Insert the hose until click indicating proper
connection.
•To remove the flexible hose press the clamps
(15) and detach the hose.
Attaching the telescopic pipe
and the brush-attachments
•Attach the telescopic extension pipe (4) to the
handle of the flexible hose (5).
•Extend the lower part of the telescopic exten-
sion pipe to the required length, having pre-
liminary pressed the clamp (3).
•Choose the necessary attachment – floor/
carpet brush (1) or combined brush (24) –
and attach it to the telescopic extension pipe
(4).
USING OF THE BRUSH ATTACHMENTS
Floor/carpet brush (1)
Set the switch (2) on the brush (1) to the required
position (depending on the type of the surface
being cleaned).
Combined brush (24)
The brush (24) is intended not only for cleaning
radiators, crevices, corners or space between
VT-1892.indd 4 03.12.2015 17:47:49

5
E N G L I S H
cushions, but for collecting dust from furniture
surface as well, the pile on the brush (24) pre-
vents damage of polished furniture surface.
Using the dustbag
1 cloth dustbag and 3 paper dustbags are sup-
plied with the unit.
•Open the dustbag compartment lid (16) by
pressing the clamp (17).
•Take the dustbag holder (23) and pull it
to remove dustbag holder (23) from the
clamps (22).
•To install the dustbag (26) back to its place,
insert the dustbag holder (23) into the
clamps (22).
•Close the dustbag compartment lid (16).
Note: Always make sure that the dustbag (26)
is installed properly before closing the lid (16).
USING THE VACUUM CLEANER
Safety measures
•Do not use the vacuum cleaner near hot
surfaces, ashtrays and in the places where
inflammable liquids are stored.
•If the suction power of the vacuum cleaner
decreases rapidly while cleaning, switch it
off immediately and check the telescopic
pipe and the flexible hose for obstruction.
Switch the vacuum cleaner off, then unplug
it, remove the obstruction and only after that
continue cleaning.
USING THE VACUUM CLEANER
Attention! Always switch the vacuum cleaner
on only with the dustbag (26) and inlet (21)
and outlet (12) filters installed. Always make
sure that the filters are installed properly.
•Before using the unit, unwind the power cord
to the required length and insert the power
plug into the mains socket.
•The yellow mark on the power cord indicates
the maximum cord length. Do not unwind the
power cord further than the red mark.
•Press the ON/OFF button (9) to switch the
vacuum cleaner on.
•During the operation you can control the suc-
tion power using the suction power control (10).
•After room cleaning switch the vacuum
cleaner off by pressing the ON/OFF button
(9) and unplug the unit.
•To wind the cord press the cord winding but-
ton (11), hold the winding cord with hand to
avoid its whipping and damage.
CLEANING AND CARE
•If full dustbag indicator (13) turns «red» during
operation, replace the paper dustbag or clean
up the cloth dustbag.
•Before cleaning or replacing the dustbag (26)
switch the vacuum cleaner off and unplug it.
•Provide that the inlet filter (21) and the outlet
HEPA filter (12) are always clean, because the
overall performance of the vacuum cleaner
depends on it; clean the filters no less than
3-4 times a year, and more often at severe
obstruction.
Cleaning the inlet filter (21)
•Switch the vacuum cleaner off and unplug it.
•Open the dustbag compartment lid (16) by
pressing the clamp (17). Remove the dust-
bag (26).
•Take the inlet filter (21) and remove it from the
holders (20) pulling it upwards.
•Wash the inlet filter (21) with warm water, dry
thoroughly and install it into the filter hold-
ers (20).
•Install the dustbag (26) back to its place.
•Close the dustbag compartment lid (16).
Cleaning the outlet HEPA filter (12)
•Switch the vacuum cleaner off and unplug it.
•Remove the outlet filter grid (7) by press-
ing the clamp (8) and remove the HEPA fil-
ter (12).
•Wash the HEPA Filter (12) under slightly warm
water jet. Do not wash the HEPA filter (12) in a
dishwashing machine.
•Dry the HEPA filter. Do not dry the HEPA filter
with a hairdryer.
•Install the HEPA filter (12) back to its place.
•Install the outlet filter grid (7) back to its place.
Notes:
– Before installing the filters (12, 21) make sure
that they are dry.
– Do not dry the filters (12, 21) with a hairdryer.
Vacuum cleaner body
– Wipe the vacuum cleaner body with a soft,
slightly damp cloth and then wipe it dry.
– Do not immerse the body of the vacuum
cleaner, the power cord and the power plug
of the unit into water or other liquids. Provide
that no liquid gets inside the vacuum cleaner
body.
– Never use solvents or abrasives to clean the
surface of the vacuum cleaner.
VT-1892.indd 5 03.12.2015 17:47:49
This manual suits for next models
1
Table of contents
Languages:
Other Vitek Vacuum Cleaner manuals

Vitek
Vitek VT-8140 User manual

Vitek
Vitek VT-1833 PR User manual

Vitek
Vitek Tornado VT-1824 SR User manual

Vitek
Vitek VT-8110 SR User manual

Vitek
Vitek VT-8109 User manual

Vitek
Vitek VT-1806 OG User manual

Vitek
Vitek VT-1827 B User manual

Vitek
Vitek VT-1829 User manual

Vitek
Vitek VT-8120 User manual

Vitek
Vitek VT-1825 B/R User manual

Vitek
Vitek VT-1805 R User manual

Vitek
Vitek VT1843 B User manual

Vitek
Vitek Storm VT-1825 B User manual

Vitek
Vitek VT-1802 User manual

Vitek
Vitek VT-1834 B User manual

Vitek
Vitek VT-1807 User manual

Vitek
Vitek VT-8114 GD User manual

Vitek
Vitek VT-1860 User manual

Vitek
Vitek VT-8128 User manual

Vitek
Vitek VT-1886 B User manual