COOPERATION AND OPERATING RANGE
* 1-channel transmitters do not cooperate with roller blind controllers
CAUTION: The given range concerns open area - an ideal condition without any
natural or articial obstacles. If there are some obstacles between a transmitter
and a receiver, it is advisable to decrease the range according to: wood and plas-
ter: from 5 to 20 %, bricks: from 10 to 40 %, reinforced concrete: from 40 to 80 %,
metal: from 90 to 100%, glass: from 10 to 20 %, Over- and underground medium
and high electrical power lines, radio and television transmitters, GSM transmit-
ters set close to a device system have also a negative inuence on the range.
Symbol ROP-01 ROP-02 ROB-01 SRP-02 SRP-03 RWG-01 RWL-01 ROM-01 ROM-10 RDP-01 RTN-01
RNK-02 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m
RNK-04 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m
P-256/8 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m
P-257/4 (2) 180 m 200 m 200 m 200 m 200 m 250 m 180 m 250 m 250 m 180 m 250 m
RNM-10 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m
RNP-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m
RNP-02 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m
RNL-01 160 m 180 m 180 m
none* none*
200 m 160 m 200 m 200 m 160 m 200 m
RTN-01 200 m 200 m 200 m 200 m 200 m 250 m 200 m 250 m 250 m 200 m 250 m
RCR-01 160 m 180 m 180 m
none* none*
200 m 160 m 200 m 200 m 160 m 200 m
RTI-01 160 m 180 m 180 m 180 m 180 m 200 m 160 m 200 m 200 m 160 m 200 m
RXM-01 230 m 250 m 250 m 250 m 250 m 300 m 200 m 300 m 300 m 230 m 300 m
REMOTE CONTROLS DELETION
Press PROG push-button of RDP-01 device for a longer time. After 5 seconds LED
red diode switches on (signal pulsates) and then it switches off. Release the push-
button in RDP-01 - MEMORY IS DELETED.
TIME PROGRAMMING
Press PROG push-button of RDP-01 device for a longer time till LED red diode switches
on (constant signal). Next release PROG push-button. Wait (for about 5 seconds) till LED red
diode switches on (rst signal pulsates, next the signal is constant). Press PROG push-
button of RDP-01 device and then release it. LED red diode switches off and then switches on
(signal pulsates). Every LED diode pulse equals 1 second. After the adjusted time is nished
(the number of LED red diode ashes) press PROG push-button and then release it - TIME IS
ADDED.
Maximum time is 18 hours.
TIME mode (one push-button):
Press PROG push-button of RDP-01 device for a longer time till LED red diode
switches on (constant signal). Next release PROG push-button. Press and then re-
lease transmitter’s push-button.LED red diode switches on (rst signal pulsates, next
the signal is constant). Press and release the same transmitter’s push-button. LED
red diode switches on (signal pulsates) and then switches off - THE TRANSMITTER
IS ADDED.
CAUTION: Every transmitter can cooperate with RDP-01 in a different mode, de-
pending on how they were added to the device. One transmitter can be added
during one programming cycle. Full memory is signalled with pulsating LED red
diode.
WIRELESS CONTROL SET - LIGHTING WITH DIMMING FUNCTION
RZB-02
TECHNICAL DATA
RNK-02 RDP-01
Input (supply) terminals:
-L, N
Input rated voltage:
3 V DC (battery CR2032) 230 V AC
Battery life:
3 ÷ 5 years -
Input voltage tolerance:
- -15 ÷ +10 %
Nominal frequency:
- 50 / 60 Hz
Nominal power consumption:
-0,5 W
Number of operation modes:
- 5
Number of channels:
2 1
Transmission:
radio 868,32 MHz
Transmission way: unidirectional
Coding: addressing transmission
Maximum number of transmitters:
- 32
Range: up to 250 m in the open air up to 230 m in the open air
Time adjustment:
-
1 s ÷ 18 hours (every second)
Optical signalling: LED red diode
Receiver’s output clamps:
-, N
Maximum output load:
- 250 W
Number of terminal clamps:
- 4
Section of connecting cables:
-up to 2,5 mm2
Ambient temperature range:
-10 ÷ +55 oC
Operating position: free
Casing mounting: wall plugs, double-sided
adhesive tape
installation cable box Ø60
mm
Casing protection degree:
IP20 (EN 60529)
Protection level:
III II
Overvoltage category:
- II
Pollution degree:
2
Surge voltage:
- 1 kV (EN 61000-4-5)
Dimensions:
90 x 80 x 11,5 mm 47,5 x 47,5 x 20 mm
Weight:
0,038 kg 0,040 kg
Reference standard: PN-ETSI EN 300 220-1,
PN-ETSI EN 300 220-2
PN-EN 60669, PN-EN 60950,
PN-EN 61000
OPERATION, MOUNTING RNK-02
By pressing the button, the transmitter sends a signal with 868,32 MHz frequency
which controls EXTA FREE receivers. Device programming procedure (adding a
transmitter to a receiver’s memory) is described in particular EXTA FREE man-
ual instructions. The device range (up to 250 m depending on a receiver) can be
increased by means of a retransmitter or few RTN-01 retransmitters.
The device can be mounted in any place by means of double-sided adhesive tape or
wall plugs 5 x (3 x 30) mm.
Mounting by means of wall plugs:
Remove the button - to do it press the button on one side, and on the other side put
a screwdriver into a slot and lift up the button (Fig. 1)
OPERATION, MOUNTING RDP-01
Disconnect power supply by the phase fuse, the circuit-breaker or the switch-discon-
nector combined to the proper circuit.
Check if there is no voltage on connection cables by means of a special measure
equipment.
Connect the cables with the terminals in accordance with the installing diagram.
Install RDP-01 device in installation cable box.
Switch on the power supply from the mains.t
CONNECTION
RDP-01 can operate in ve modes:
COMFORT (Available only in cooperation with 4 push-button transmitter). In this mode
the following two functions are realised:
ONE PUSH-BUTTON Pressing the programmed push-button shortly (<0.8 sec.) caus-
es the dimmer to operate in the range of switch on/switch off (to the last adjustment of
lighting luminous density level), however pressing the programmed push-button longer
(>0.8 sec.) causes alternate lighting brightening - dimming.
TWO PUSH-BUTTONS SWITCH ON pushbutton: pressing the programmed push-
button shortly (<0.8 sec.) causes the lighting switches on according to the last adjust-
ment of lighting luminous density level, however pressing the programmed push-button
longer (>0.8 sec.) causes lighting brightening to the maximum level. SWITCH OFF
pushbutton: pressing the programmed push-button shortly (<0.8 sec.) causes the
lighting switches off, however pressing the programmed push-button longer (>0.8 sec.)
causes lighting dimming to the minimum level.
TIME The device after pressing the pushbutton switches on according to the adjusted
time (tp), then it switches off automatically. Another pressing of the push-button dur-
ing time countdown causes the lighting is switched off before adjusted time nishes.
Default settings - 15 seconds.
CAUTION! Adjusted time cannot be deleted.
COMFORT mode:
Press RNK-04 transmitter’s push-button for a longer time. Press PROG push-
button of RDP-01 device for a longer time until LED red diode switches on (constant
signal). Next release PROG push-button Release transmitter’s pushbutton. LED red
diode switches on (rst signal pulsates, next the signal is constant). Press the same
transmitter’s pushbutton and release it. LED red diode switches on (the signal pulsates)
and next it switches off - THE TRANSMITTER IS ADDED.
ONE PUSH-BUTTON mode:
Press PROG push-button of RDP-01 device for a longer time until LED red diode
switches on (constant signal). Next release PROG push-button. Press the transmit-
ter’s push-button for a longer time. LED red diode switches on (rst signal pulsates,
next the signal is constant). Release transmitter’s push-button. LED red diode switch-
es on (the signal pulsates), next the LED red diode switches off - it means the TRANS-
MITTER IS ADDED.
SWITCH ON/SWITCH OFF mode (two push-buttons):
Press PROG push-button of RDP-01 device for a longer time until LED red diode
switches on (constant signal). Next release PROG push-button. Press and release
transmitter’s rst push-button. LED red diode switches on (rst signal pulsates, next the
signal is constant). Press and release the second transmitter’s push-button. LED red
diode switches on (the signal pulsates) and next it switches off - THE TRANSMITTER
IS ADDED.
REMOTE CONTROLS PROGRAMMING
Find a place on the wall to mount the transmitter, make two holes corresponding
mounting holes from the transmitter’s base.
Set wall plugs in the holes.
Fix the base by means of screwing screws into wall plugs.
Place the button again.
BATTERY CHANGE
Battery discharge status is signalled by several LED red diode ashes during
transmission time.
Remove the button (Fig. 1).
By means of a screwdriver lever up the printedcircuit board releasing the bottom
latch (Fig. 2), and remove it from the base.
Remove the battery from the latch (Fig. 3).
Mount a new battery. Watch battery polarisation marked on the latch. Wrong battery
mounting may cause device damage.
Put the removed printed-circuit board back in the base.
Put the button back.
CAUTION: While changing the battery, it is suggested to press any of the but-
tons for about 5 seconds before putting it into a latch. Next press transmission
button several times to check its operation. If the transmitter does not work
properly repeat the battery change procedure.
Fig. 1
Fig. 2 Fig. 3

Other manuals for Extra Free RZB-02

2

This manual suits for next models

2

Other Zamel Controllers manuals

Zamel RZB-03 User manual

Zamel

Zamel RZB-03 User manual

Zamel Exta Life EFC-01 User manual

Zamel

Zamel Exta Life EFC-01 User manual

Zamel Extra Free ROB-01/12-24V User manual

Zamel

Zamel Extra Free ROB-01/12-24V User manual

Zamel Exta Free EFC-02 Mini User manual

Zamel

Zamel Exta Free EFC-02 Mini User manual

Zamel exta ZIM-12/25 User manual

Zamel

Zamel exta ZIM-12/25 User manual

Zamel Wi-Fi supla ROW-02 User manual

Zamel

Zamel Wi-Fi supla ROW-02 User manual

Zamel ledix SLR-11 User manual

Zamel

Zamel ledix SLR-11 User manual

Zamel RTD-02 User manual

Zamel

Zamel RTD-02 User manual

Zamel supla SRW-01 User manual

Zamel

Zamel supla SRW-01 User manual

Zamel RZB-04 User manual

Zamel

Zamel RZB-04 User manual

Zamel exta SRP-05 User manual

Zamel

Zamel exta SRP-05 User manual

Zamel Wi-Fi supla SLW-01 User manual

Zamel

Zamel Wi-Fi supla SLW-01 User manual

Zamel Extra Free ROB-01/12-24V User manual

Zamel

Zamel Extra Free ROB-01/12-24V User manual

Zamel RNK-02 User manual

Zamel

Zamel RNK-02 User manual

Zamel exta RTM-20 User manual

Zamel

Zamel exta RTM-20 User manual

Zamel GRM-10 User manual

Zamel

Zamel GRM-10 User manual

Zamel ledix SLR-13 User manual

Zamel

Zamel ledix SLR-13 User manual

Zamel RTM - 01 User manual

Zamel

Zamel RTM - 01 User manual

Zamel Cet LediX SLR-11P User manual

Zamel

Zamel Cet LediX SLR-11P User manual

Zamel exta ZCM-22 Series User manual

Zamel

Zamel exta ZCM-22 Series User manual

Zamel SRP-02 User manual

Zamel

Zamel SRP-02 User manual

Zamel RNK-02 User manual

Zamel

Zamel RNK-02 User manual

Zamel RTS-01A User manual

Zamel

Zamel RTS-01A User manual

Zamel exita ZIM-12/08 User manual

Zamel

Zamel exita ZIM-12/08 User manual

Popular Controllers manuals by other brands

ABB Contrac PME120AI Service instruction

ABB

ABB Contrac PME120AI Service instruction

UDLA Douglas Lighting Controls BT-PP20-A installation manual

UDLA

UDLA Douglas Lighting Controls BT-PP20-A installation manual

Lennox CLIMATIC series user manual

Lennox

Lennox CLIMATIC series user manual

ITOH DENKI CBM-103FN manual

ITOH DENKI

ITOH DENKI CBM-103FN manual

Desert Aire CM3550 Series Installation and operation manual

Desert Aire

Desert Aire CM3550 Series Installation and operation manual

Coilhose Pneumatics CH-119 Installation & service instructions

Coilhose Pneumatics

Coilhose Pneumatics CH-119 Installation & service instructions

Renishaw UCC T3 PLUS installation guide

Renishaw

Renishaw UCC T3 PLUS installation guide

t.a.c. Forta M700 manual

t.a.c.

t.a.c. Forta M700 manual

Johnson Controls VA7820-HG*-2 Series installation guide

Johnson Controls

Johnson Controls VA7820-HG*-2 Series installation guide

Adaptec 5805 Installation and user guide

Adaptec

Adaptec 5805 Installation and user guide

Endress+Hauser RA33 operating instructions

Endress+Hauser

Endress+Hauser RA33 operating instructions

Anolis ArcControl SU user manual

Anolis

Anolis ArcControl SU user manual

Genie 36448 A quick start guide

Genie

Genie 36448 A quick start guide

APAR AR653 user manual

APAR

APAR AR653 user manual

FFES Z Series instruction manual

FFES

FFES Z Series instruction manual

Pixsys DRR 245 user manual

Pixsys

Pixsys DRR 245 user manual

MicroMetl ECD-SRTCA-D2 install guide

MicroMetl

MicroMetl ECD-SRTCA-D2 install guide

Sunlight Supply TITAN CONTROLS KRONUS 2 instruction manual

Sunlight Supply

Sunlight Supply TITAN CONTROLS KRONUS 2 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.