MATEC – ELECTRIC HEATING SYSTEMS
TEMPERATURE CONTROLLER RTS-01A
INSTRUCTION MANUAL
ZAMEL Sp. z o.o.
ul. Zielona 27, 43-200 Pszczyna, Poland
tel. +48 32 449 15 00, +48 32 210 46 65, fax +48 (32) 210 80 04
www.zamel.com, e-mail: [email protected]
VER. 002_17.06.2016
APPEARANCE
The device is designed for one-pha-
se installation and must be installed in
accordance with standards valid in a
particular country. The device should
be connected according to the details
included in this instruction manual. Installation,
connection and control should be carried out by a
qualied electrician staff, who acts in accordance
with the instruction manual and the device func-
tions. Disassembling of the device is equal with a
loss of guarantee and can cause electric shock. Be-
fore installation make sure the connection cables
are not under voltage. The cruciform head screw-
driver 2,5 mm should be used to install the device.
Improper transport, storage, and use of the device
inuence its wrong functioning. It is not advisable
to install the device in the following cases: if any
device’s part is missing or the device is damaged
or deformed. In case of improper functioning of the
device contact the producer.
The symbol stands for selective
collection of electrical and electronic
devices. Placing used devices with
other waste is not allowed
CAUTION
FEATURES
TECHNICAL DATADESCRIPTION
● LCD display showing current room tempe-
rature
● Economical or comfort mode operation
● Optional temperature display: Celsius or
Fahrenheit scales
● Temperature controlled by built-in (internal)
sensor, or external oor sensor
● Easy to use
The RTS-01A temperature controller is
a non-programmable controller used for oor
heating. The controller cooperates with electric
oor heatig system. The RTS-01A device can
control the temperature by means of built-in
(internal) or oor (external) sensor.
The temperature controller should be instal-
led:
●in a heating room (at surface mounting, or
in cable box Ø60), 120 cm high from the he-
ating zone
● in a place not exposed to direct sunlight
● in a place not exposed to strong wind blows
The temperature in the mounting place should
be from 5°C to +50°C
RTS-01A
Input terminals: L (5), N (6)
Input rated voltage: 100 ÷ 240 V~
Nominal frequency: 50 / 60 Hz
Rated power consumption: 0,35 W in STANDBY mode
Battery backup: no
NTC sensor terminals: RT+, RT-
Temperature sensor: NTC 100 k for 25 ºC
Room temperature adjustment range: +5 ÷ +30 °C
Floor temperature control range: +5 ÷ +40 °C
Temperature measurement accuracy: ±1 °C
Relay parameters: 16 A / 230 V
Number of terminal clamps: 6
Section of connecting cables: 0,5 ÷ 1,5 mm2
Ambient temperature range: -5 ÷ +50 oC
Casing mounting: surface
Casing protection degree: IP21
Protection level: II
Overvoltage category: II
Dimensions: 86 x 86 x 32 mm
Weight: 0,114 kg
Reference standards: EN 60730-1:2000+A2:2008,
EN 60730-2-9:2002+A2:2005,
EN 61000-3-2:2006,
EN 61000-3-3:2008,
EN 55014-2:1997+A1:2001+A2:2008,
EN 55014-1:2006+A1:2010
Main switch ON/OFF
Base mounting screw
LCD display
Adjustment knob
Temperature sensor terminals
Mode switch
Output relay terminals
Input terminals
heating mat
temperature cotroller
VER. 002_17.06.2016
MOUNTING
1. Disconnect the power supply from the mains
by: the phase fuse, circuit-breaker or switch
disconnector joined to the proper circuit,
2. By means of special equipment check if
there is no voltage on connection cables.
3. After unscrewing the screw, carefully remove
the upper cover.
4. Choose mounting place on the wall, make two
holes corresponding to mounting holes of the
temperature controller’s base.
5. Set wall plugs in the holes.
6. Pull Installation cables through holes in the
base.
7. Mount the base by means of screws, screw
them into the wall plugs.
8. Connect the cables with the terminals accor-
ding to the installing diagram.
9. Connect the external sensor to the RT2-, RT2+
terminals, if necessary.
10. Adjust controller’s operation parameters by
means of operation mode switch.
11. Place the upper cover on the base.
12. Screw the regulator’s base. Only ø3 mm
screws can be used and with maximum length
of 8 mm.
13. Switch on the power supply from the mains and
check the regulator’s operation.
CAUTION:
the cable with oor sensor must not
be shortened.
OPERATING
During standard operation the LCD display shows current room temperature. Current temperature ad-
justment is shown in pulsating form while turning the knob.
Temperature adjustment
Adjust required temperature by means of controller’s knob. Adjusted temperature will be shown in
pulsating form on the LCD display. After some time it will stop and show current room temperature.
Heating status: The ame symbol appears when the controller starts heating.
The controller is equipped with built-in (internal) temperature sensor and terminals marked as RT2-,
RT2+ used for external (oor) temperature sensor connection. If the external sensor is connected to
the terminals then the temperature is controlled by the external sensor. Otherwise the temperature
controller will use the built-in controller.
Error chart (Error symbol pulsates on the LCD display)
Symbol Description
„E1” pulsates Short-circuit of internal sensor. The temperature controller cuts off the output.
„E2” pulsates Room sensor damage. The temperature controller cuts off the output.
„E3” pulsates Short-circuit of external (oor) sensor. The temperature controller cuts off the output.
„E4” pulsates Floor sensor damage. The temperature controller cuts off the output.
In case of internal(oor) sensor breakdown, the temperature is controlled by (built-in) internal sensor.
If the room temperature is higher than 30ᵒC, than „HI“symbol appears on the display. Then in the
heating mode the controller’s output is cut off, whereas in the cooling mode cooling should start. If
the room temperature is lower than 5ᵒC than „LO“symbol appears on the display. In the heating mode
heating should start and in the cooling mode cooling should switch off.
GUARANTEE CARD
There is 24 months guarantee on the product
Salesman stamp and signature, date of sale
1. ZAMEL Sp. z o.o. assures 24 months guarantee for the product.
2. The manufacturer’s guarantee does not cover any of the following actions:
a) mechanical damage during transport, loading / unloading or under other circumstances,
b) damage caused by incorrect product mounting or misuse,
c) damage caused by unauthorised modications made by the PURCHASER or any third parties to the product or any other devices
needed for the product functioning,
d) damage caused by Act of God or any other incidents independent of the manufacturer - ZAMEL Sp z o.o.
e) power supply (batteries) to be equipped with a device in the moment of sale (if they appear);
3. The PURCHASER shall lay any claims in writing to the dealer or ZAMEL Sp. z o.o.
4. ZAMEL Sp. z o.o. is liable for processing any claim according to current Polish legislation.
5. ZAMEL Sp. z o.o. shall process the claim at its own discretion: product repair, replacement or money return.
6. The manufacturer’s guarantee is valid in the Republic of Poland.
7. The PURCHASER’s statutory rights in any applicable legislation whether against the retailer arising from the purchase contract or
otherwise are not affected by this warranty.
CONNECTING
Electric oor heating system
SWITCHES ADJUSTEMENT CONFIGURATION
Mode Description
mode switch set on:
the relay is switched on
the relay is switched off
1
°F °C
2
ROOM
3
FLOOR
4
10-16 A 3-8 A
1
°F °C
2
ROOM
3
FLOOR
4
10-16 A 3-8 A
ºF / ºC degree – temperature unit, ROOM, FLOOR
Temperature control from internal sensor
Temperature control from external sensor (at the oor)

Other Zamel Controllers manuals

Zamel SRP-03 User manual

Zamel

Zamel SRP-03 User manual

Zamel RTD-02 User manual

Zamel

Zamel RTD-02 User manual

Zamel RTM - 01 User manual

Zamel

Zamel RTM - 01 User manual

Zamel RNK-02 User manual

Zamel

Zamel RNK-02 User manual

Zamel Exta Life EFC-01 User manual

Zamel

Zamel Exta Life EFC-01 User manual

Zamel exta ZIM-12/25 User manual

Zamel

Zamel exta ZIM-12/25 User manual

Zamel Wi-Fi supla SLW-01 User manual

Zamel

Zamel Wi-Fi supla SLW-01 User manual

Zamel Extra Free ROB-01/12-24V User manual

Zamel

Zamel Extra Free ROB-01/12-24V User manual

Zamel exta SRP-05 User manual

Zamel

Zamel exta SRP-05 User manual

Zamel SRP-02 User manual

Zamel

Zamel SRP-02 User manual

Zamel RNK-02 User manual

Zamel

Zamel RNK-02 User manual

Zamel Wi-Fi supla ROW-02 User manual

Zamel

Zamel Wi-Fi supla ROW-02 User manual

Zamel exta MOM-02 User manual

Zamel

Zamel exta MOM-02 User manual

Zamel RNK-02 User manual

Zamel

Zamel RNK-02 User manual

Zamel exta ZCM-22 Series User manual

Zamel

Zamel exta ZCM-22 Series User manual

Zamel RZB-05 User manual

Zamel

Zamel RZB-05 User manual

Zamel exta SRM-11 User manual

Zamel

Zamel exta SRM-11 User manual

Zamel exta RTM-20 User manual

Zamel

Zamel exta RTM-20 User manual

Zamel RZB-04 User manual

Zamel

Zamel RZB-04 User manual

Zamel Extra Free RZB-02 User manual

Zamel

Zamel Extra Free RZB-02 User manual

Zamel ROW-01 User manual

Zamel

Zamel ROW-01 User manual

Zamel Cet Ledix SLR-01 User manual

Zamel

Zamel Cet Ledix SLR-01 User manual

Zamel exta SRP-01/M User manual

Zamel

Zamel exta SRP-01/M User manual

Zamel exta life ROB-21 User manual

Zamel

Zamel exta life ROB-21 User manual

Popular Controllers manuals by other brands

Tunze SmartController 7000.001 Instructions for use

Tunze

Tunze SmartController 7000.001 Instructions for use

CIRCLE Home Plus user guide

CIRCLE

CIRCLE Home Plus user guide

AVIRE Memco Panachrome+ installation guide

AVIRE

AVIRE Memco Panachrome+ installation guide

Metal Work REGTRONIC IO-Link user manual

Metal Work

Metal Work REGTRONIC IO-Link user manual

Danfoss erc 112 user manual

Danfoss

Danfoss erc 112 user manual

Full Gauge MT-512Ri LOG quick start guide

Full Gauge

Full Gauge MT-512Ri LOG quick start guide

Elko iNELS RFSTI-111B quick start guide

Elko

Elko iNELS RFSTI-111B quick start guide

Viconics VT8000 Series installation guide

Viconics

Viconics VT8000 Series installation guide

GCE MediVital E Instructions for use

GCE

GCE MediVital E Instructions for use

SABINE FBX SOLO 620 SL-620 operating guide

SABINE

SABINE FBX SOLO 620 SL-620 operating guide

GREAT PLANES ElectriFly Silver Series SS-60 manual

GREAT PLANES

GREAT PLANES ElectriFly Silver Series SS-60 manual

Pneumax AirPlus 1700 Series manual

Pneumax

Pneumax AirPlus 1700 Series manual

Motoman NX100 Function manual

Motoman

Motoman NX100 Function manual

Elitech ECS-2180neo manual

Elitech

Elitech ECS-2180neo manual

Domenor K72 user manual

Domenor

Domenor K72 user manual

Mitsubishi Electric Q172DCPU user manual

Mitsubishi Electric

Mitsubishi Electric Q172DCPU user manual

Wolf SWP-200 quick start guide

Wolf

Wolf SWP-200 quick start guide

microHAM micro2R u2R user guide

microHAM

microHAM micro2R u2R user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.