© Zennio Avance y Tecnología S.L. Edition 3 Futher information www.zennio.com Page 1/2
MINiBOX 25 v2
Multifunction actuator with 2 outputs and 5 inputs
ZIOMN25V2 TECHNICAL DOCUMENTATION
FEATURES
•2 different configurable outputs: shutter channel (up to 1) and individual
outputs (up to 2)
•Outputs suitable for capacitive loads, maximum 140 µF.
•5 analog/digital inputs.
•Manual output operation with push button and LED Status indicator.
•10 logic functions.
•Output timing.
•4 thermostats.
•Total data saving on KNX bus failure.
•Integrated KNX BCU.
•Dimensions 67 x 90 x 35 mm (2 DIN units).
•DIN rail mounting (EN 50022), with fixing clamp.
•Possibility of connecting different phases in adjacent outputs.
•Conformity with the CE directives (CE-mark on the right side).
1. Analog/Digital inputs
2. Outputs
3. Output status LED indicator
4. Output control button
5. Programming/test LED
6. Programming/test button
7. KNX Connector
A1 A2
M
N
L
A1 A2
N
L
L1 L2
CIN CIN
C I
CIN
A1 A2
NL1
L1 L2
L2
4
1
7
6
3
5
2
Figure 1: MINiBOX 25 v2
Programming/Test button: short press to set programming mode. If this button is held while plugging the device into the KNX bus, it enters the safe
mode. If this button is held for more than 3 seconds, the device enters the test mode.
Programming/Test LED: programming mode indicator (red). When the device enters the safe mode, it blinks (red) every half second. The manual mode
is indicated by the green color. During the start-up (reset or after KNX bus failure)and if the device is notin safe mode, itstarts a blue blinking sequence.
GENERAL SPECIFICATIONS
CONCEPT
DESCRIPTION
Type of device
Electric operation control device
KNX supply
Voltage (typical)
29VDC SELV
Voltage range
21..31VDC
Maximum
consumption
Voltage
mA
mW
29VDC (typical)
4.6
133.4
24VDC¹
10
240
Connection type
Typical TP1 bus connector for 0.80mm Ø rigid cable
External power supply
Not required
Operation temperature
0°C .. +55°C
Storage temperature
-20°C .. +55°C
Operation humidity
5 .. 95%
Storage humidity
5 .. 95%
Complementary characteristics
Class B
Protection class / Overvoltage category
II / III (4000V)
Operation type
Continuous operation
Device action type
Type 1
Electrical stress period
Long
Degree of protection / Pollution degree
IP20 / 2 (clean environment)
Installation
Independent device to be mounted inside electrical panels with DIN rail (EN
50022)
Minimum clearances
Not required
Response on KNX bus failure
Data saving according to parameterization
Response on KNX bus restart
Data recovery according to parameterization
Operation indicator
The programming LED indicates programming mode (red) and test mode
(green). Each output LED indicates its status
Weight
78g
PCB CTI index
175V
Housing material / Ball pressure test temperature
PC FR V0 halogen free / 75ºC (housing) - 125ºC (connectors)
¹ Maximum consumption in the worst-case scenario (KNX Fan-In model)
© Zennio Avance y Tecnología S.L. Edition 3 Futher information www.zennio.com Page 2/2
SAFETY INSTRUCTIONS
•Installation should only be performed by qualified professionals according to the laws and regulations applicable in each country.
•Do not connect the mains voltage nor any other external voltage to any point of the KNX bus; it would represent a risk for the entire
KNX system. The facility must have enough insulation between the mains (or auxiliary) voltage and the KNX bus or the wires of other
accessories, in case of being installed.
•Once the device is installed (in the panel or box), it must not be accessible from outside.
•Keep the device away from water (condensation over the device included) and do not cover it with clothes, paper or any other material
while in use.
•The WEEE logo means that this device contains electronic parts and it must be properly disposed of by following the instructions at
http://zennio.com/weee-regulation.
OUTPUTS SPECIFICATIONS AND CONNECTIONS
CONCEPT
DESCRIPTION
Number of outputs
2
Output type / Disconnection type
Potential-free outputs through bistable relays with
tungsten pre-contact / Micro-disconnection
Rated current per output
AC 16(6)A @ 250VAC (4000VA)
DC 7A @ 30VDC (210W)
Maximum load
per output
Resistive
4000W
Inductive
1500VA
Maximum inrush current
800A/200μs
165A/20ms
Connections in adjacent outputs
Possibility of connecting different phases. It is not
allowed to connect power supplies of different
order, SELV with NO SELV, in the same block
Total maximum current in device
20A
Short-circuit protection
NO
Overload protection
NO
Connection method
Screw terminal block
Cable cross-section
0.5-4mm² (IEC) / 20-12AWG (UL)
Outputs per common
1
Maximum response time
10ms
Mechanical lifetime (min. cycles)
3 000 000
Electrical lifetime (min. cycles)1
100000 @ 8A / 25000 @ 16A (VAC)
¹ Lifetime values could change depending on the load type.
INPUTS SPECIFICATIONS AND CONNECTIONS
CONCEPT
DESCRIPTION
Number of inputs
5
Inputs per common
1
Operation voltage
+3.3VDC in the common
Operation current
1mA @ 3.3VDC (per input)
Switching type
Dry voltage contacts between input and common
Connection method
Screw terminal block
Cable cross-section
0.5-2.5mm² (IEC) / 26-12AWG (UL)
Maximum cable length
30m
NTC probe length
1.5m (up to 30m)
NTC accuracy (@ 25°C) ²
±0.5°C
Temperature resolution
0.1°C
Maximum response time
10ms
² For Zennio temperature probes.
⚠In order to ensure the expected status of the
relays, please check that the device is connected to
the KNX bus before energizing the power circuit.
WIRINGDIAGRAMS
Figure 2: Wiring example (from left to
right, and up to down): 2 loads, 2 loads
connected to different phases and shutter
* In case of using ZN1IO-DETEC-P sensor, its micro switch number 2 must be in Type B position.
** Zennio temperature probe or any NTC with known resistance values at three points in the range [-55, 150ºC].
INPUTSCONNECTION
Any combination of the following accessories is allowed on the inputs:
Zennio temperature
probe.
Up to two motion sensors
can be plugged into the
same device input (parallel
wiring)
Screw terminal for
connecting Zennio motion
sensors*
Temperature Probe**
Motion Sensor
Switch/Sensor/
Push button
CIN CIN
C I
CIN
CIN CIN
C I
CIN
CIN CIN
C I
CIN
Attaching MINiBOX 25 v2 to DIN rail:
Removing MINiBOX 25 v2 from DIN rail:
A1 A2
M
N
L
A1 A2
N
L
L1 L2
CIN CIN
C I
CIN
A1 A2
NL1
L1 L2
L2
A1 A2
M
N
L
A1 A2
N
L
L1 L2
CIN CIN
C I
CIN
A1 A2
NL1
L1 L2
L2

This manual suits for next models

1

Other Zennio Controllers manuals

Zennio MAXinBOX 24 v2 Guide

Zennio

Zennio MAXinBOX 24 v2 Guide

Zennio MAXinBOX FC 0-10V FAN User manual

Zennio

Zennio MAXinBOX FC 0-10V FAN User manual

Zennio DIMinBOX 2CH ZDI-DB2C User manual

Zennio

Zennio DIMinBOX 2CH ZDI-DB2C User manual

Zennio MAXinBOX SHUTTER 8CH v3 Guide

Zennio

Zennio MAXinBOX SHUTTER 8CH v3 Guide

Zennio MAXinBOX 24 ZIO-MB24 User manual

Zennio

Zennio MAXinBOX 24 ZIO-MB24 User manual

Zennio ALLinBOX 1612 v2 User manual

Zennio

Zennio ALLinBOX 1612 v2 User manual

Zennio LUMENTO X4 Guide

Zennio

Zennio LUMENTO X4 Guide

Zennio MINiBOX 0-10V X3 User manual

Zennio

Zennio MINiBOX 0-10V X3 User manual

Zennio FANinBOX 110V 1CH Guide

Zennio

Zennio FANinBOX 110V 1CH Guide

Zennio MINiBOX 45v2 User manual

Zennio

Zennio MINiBOX 45v2 User manual

Zennio MAXinBOX 8 Plus Guide

Zennio

Zennio MAXinBOX 8 Plus Guide

Zennio ZCL-MCC User manual

Zennio

Zennio ZCL-MCC User manual

Zennio MINiBOX 25 Guide

Zennio

Zennio MINiBOX 25 Guide

Zennio MAXinBOX 16 Guide

Zennio

Zennio MAXinBOX 16 Guide

Zennio ZCL-FC010F Guide

Zennio

Zennio ZCL-FC010F Guide

Zennio FANinBOX 110V 1CH Guide

Zennio

Zennio FANinBOX 110V 1CH Guide

Zennio MAXinBOX Hospitality ZCL-HP126 User manual

Zennio

Zennio MAXinBOX Hospitality ZCL-HP126 User manual

Zennio MINiBOX 25 v3 Guide

Zennio

Zennio MINiBOX 25 v3 Guide

Zennio IRSC Plus User manual

Zennio

Zennio IRSC Plus User manual

Zennio AudioInRoom User manual

Zennio

Zennio AudioInRoom User manual

Zennio HeatingBOX 230V 4X Guide

Zennio

Zennio HeatingBOX 230V 4X Guide

Zennio MAXinBOX66 Guide

Zennio

Zennio MAXinBOX66 Guide

Zennio Tecla 55 User manual

Zennio

Zennio Tecla 55 User manual

Zennio MAXinBOX FC 0-10V FAN Guide

Zennio

Zennio MAXinBOX FC 0-10V FAN Guide

Popular Controllers manuals by other brands

Oriental motor DGII Series operating manual

Oriental motor

Oriental motor DGII Series operating manual

MegaLite MEMO CORE CONTROL user manual

MegaLite

MegaLite MEMO CORE CONTROL user manual

WarmlyYours SCW-120-15A installation manual

WarmlyYours

WarmlyYours SCW-120-15A installation manual

Kimex HM-SP108E Assembly guide

Kimex

Kimex HM-SP108E Assembly guide

z21 XL BOOSTER quick start guide

z21

z21 XL BOOSTER quick start guide

OJ ETV-P Series instructions

OJ

OJ ETV-P Series instructions

Carel pRack pR300T user manual

Carel

Carel pRack pR300T user manual

Sonance AF12 Features & specifications  manual

Sonance

Sonance AF12 Features & specifications manual

MAKELSAN MRG33 Series user manual

MAKELSAN

MAKELSAN MRG33 Series user manual

Azatrax SHS installation guide

Azatrax

Azatrax SHS installation guide

Timotion JP4 user manual

Timotion

Timotion JP4 user manual

ROBO Cylinder GRSS instruction manual

ROBO Cylinder

ROBO Cylinder GRSS instruction manual

Danfoss AK-SM 800 operating guide

Danfoss

Danfoss AK-SM 800 operating guide

Tecomat TC600 Series manual

Tecomat

Tecomat TC600 Series manual

ABB PSTX 30***105 Service manual

ABB

ABB PSTX 30***105 Service manual

SONIX SN8P1600 Series user manual

SONIX

SONIX SN8P1600 Series user manual

Omron CK3M Seres Hardware user manual

Omron

Omron CK3M Seres Hardware user manual

D-Link DSA-6100 user guide

D-Link

D-Link DSA-6100 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.