82460 Page 2 of 2
Take the second white 1/4" tube from the filter kit, and run it from the
left side outlet of the filter head, to the chilled water product inlet.
Take the third length of 1/4" tubing and connect it to the pressure relief
valve drain outlet in the same manner as described earlier, using the
second small brass insert.
Run and connect the other end of this waste tube to an approved waste
point as per AS3500.
COMMISSION THE SYSTEM
Clip up the tubing in the cupboard. After the appliance is installed and
connected, turn 'ON' the water supply. Check all connections for leaks.
Repair any found.
The filter and tubing are full of air until purged, and some whitish
looking colouration of the water will occur when first used.
Flip up the operating lever on the appliance outlet tap for a minimum of
five minutes until all of the air has been purged from the system, and
the filter cartridge becomes fully saturated.
Every time the filter cartridge is replaced, repeat the procedure of a
five-minute flush to purge the new cartridge properly.
Dispose of all packaging wisely.
PRECAUTIONS
The kit connects between the incoming cold water supply and the Zip
chilling water unit.
When properly installed and maintained, it is rated to filter out particles
of five micron and larger in size, to International Standard NSF 42.
For safe operation, thoroughly flush the water through after nonuse
periods longer than 12 hours. The filter cartridge should be replaced at
least every 6-9 months, or sooner if you notice: A. a persistent
reduction in water pressure from the product, or; B. an unpleasant taste
or odour in the water.
Not changing cartridges when required may cause the water to
become biologically unsafe.
All plumbing connections must be made in accordance with AS3500
and local Water Authority by-laws. This appliance incorporates backflow
protection complying with AS3500.1. No further backflow protection is
required for connection to the water supply. Operating pressures are
175 kPa minimum and 860 kPa maximum.
Take care, when bending rigid plastic tubing, to prevent it from kinking
or crushing around a bend. As it is plastic tubing containing water
under mains pressure, be careful not to nick, scratch, cut or damage it
during installation.
Installation Instructions
Filtration System
Sub-Micron Filter Kit 82341
Five-Micron Filter Kit 81251
Filter Cartridge Insertion and removal.
Align the tabs of the cartridge with the filter housing and insert it up
into the socket.
Turn the cartridge a quarter turn to the right until it locks into
position.
Reverse this procedure for removal.
Rotate
screw
90° to
operate.
on
off
The Restrictaflow also acts as a service valve to
isolate the supply for servicing and filter
changing. Orient the Restrictaflow so that the
adjustable screw always remains visible and
accessible.
Contact:
Zip Heaters (Aust) Pty. Ltd.
67 Allingham Street, Condell Park NSW 2200
Postal: Locked Bag 80, Bankstown 1885
Website: www.zipheaters.com
Facsimile: (02) 9796 3858
Telephone: (02) 9796 3100
Free Call: 1 800 638 633