Product Specifications
Sensor Range: 12” to 60” (adjustable)
Battery Type : AA Duracell Alkaline – Model MN-1500
Battery Life: 3 years at 4,000 flushes per month
Flush Volume: ZR-6000 – 4.5 gallons per flush
ZR-6000-WS – 3.5 gallons per flush
ZR-6000-WS1 – 1.6 gallons per flush
ZR-6001 – 3.0 gallons per flush
ZR-6003-WS – 1.5 gallons per flush
ZR-6003-WS1 – 1.0 gallons per flush
Voltage: 6 VDC
Operating Water
Pressure: 45 psi min running; 80 psi max static.
Note: Installations with running pressure below
recommended value may void warranty.
Automatic Flush: Flush 24 hours after the last use (switchable)
Maintenance
Override: Magnetic flush triggering or inhibiting switch (see
page 2)
Indicator Light: Range Adjustment (first ten minutes)
Low Battery Indication (see page 2)
Reflective surface in view for greater than 30 minutes
(see page 2)
Reset Button: To restart ten-minute range adjustment cycle
To enter option changes in the electronics after
repositioning switches (see page 2)
Operating
Temperature: 35°F to 104°F (2°C to 40°C)
Outside Case
and Cover: Chrome-Plated Die Casting
Operation
1. Invisible light rays are continually emitted from the RetroFlush sensor.
2. When the user comes into range of the sensor’s detection zone (range
12 to 60 inches), the beam is reflected back to the sensor’s receiver
and converted to a low voltage electrical signal that activates an
eight-second time delay circuit. This time delay prevents the unit from
incidental activation in the restroom. Once this circuit is completed, the
output circuit is signaled and continues in a “hold” mode for as long as
the user remains within range of the sensor. User must be in sensor
range for at least 10 seconds.
3.Aftertheuser moves awayfrom thesensor,theabsenceof reflectedlight
starts an electrical “one-time” signal that operates the solenoid operator
(6 VDC) and activates the flushing cycle to flush the fixture. The circuit
then automatically resets for the next user.
IMPORTANT NOTE: The Zurn AquaVantage is engineered for quiet
operation. Excessive water flow creates noise, while too little water
flow may not satisfy the needs of the fixture. Proper adjustment of stop
valve is made when:
1.The plumbingfixture iscleansed after eachflush withoutsplashingwater
out from the lip.
2.Aquiet flushing cycle is achieved.After adjustment of the stop adjusting
screw: replace the Zurn stop cap screw cover.
Care and Cleaning Instructions
DO NOT use abrasive or chemical cleaners to clean flush valve as they
will dull the luster and attack the chrome or special decorative finishes.
Use only mild soap and water, then wipe dry with a clean cloth or towel.
While cleaning the bathroom tile and floor, the flush valve and electronics
should be protected from splattering of water, cleaner, acids and cleaning
fluids that can damage the sensor flush valve.
Problem Cause Solution
Valve will not operate Water supply shut off Turn on water supply, check control stop and supply
Sensor range adjustment set too short Increase sensor range adjustment
Expired batteries Replace batteries
Difficulty with electronic control module Check batteries. If problem continues, consult factory.
Solenoid problem Replace solenoid
Red light flashes when
user is not present Obstruction in front of the sensor Remove the obstruction
Sensor range set too long
Sensor is detecting opposite wall Shorten sensor range
Red light flashes when
user comes into view Batteries about to expire Replace batteries
Unit is in start-up mode Light will stop in 10 minutes
Range adjustment reset button was
pressed. Light will stop in 10 minutes
Valve does not shut off Dirt in diaphragm bypass hole Clean bypass hole
Dirt or debris at valve seat or sealing area Clean valve seat and clean diaphragm kit
Riser tube filter plugged Clean filtered riser tub
Solenoid problem Replace solenoid
Not enough water to
fixture Wrong RetroFlush unit installed Check fixture requirements. Install proper RetroFlush
unit.
Control stop improperly adjusted Adjust control stop
Diaphragm damaged Replace diaphragm
Low running pressure Adjust water supply to ensure 45 psi running pressure
at each valve. Move switch #1 to the off position and
press the RESET button for more water per flush.
Solenoid problem Replace solenoid
Too much water for
fixture Wrong RetroFlush unit installed Check fixture requirements. Install proper RetroFlush
unit.
Control stop improperly adjusted Adjust control stop
Dirt in diaphragm bypass hole Clean bypass hole
Customer wishes to realize maximum water
savings Change out yellow volume control to red volume
control included with kit.
Water drips from
chrome cap The plastic cover has been cracked by
freezing or abuse Replace plastic cover
The chrome cap is not tight Tighten chrome cap