FV486 Rev. D 7/16/18
Page 2
Zurn EcoVantage Dual Flush System Features
• Full Flush
The sensor will provide a full ush after a user is in range for 60 or
more seconds. The rst eight-seconds is a delay to prevent actuation
of the ush valve by a person walking past the sensor.
• Automatic 24-Hour Flush
The sensor will provide an automatic ush 24 hours after the last
ush. The automatic ush feature can be manually switched on or off
in the eld, depending on owner preference. The option is controlled
by switch number one. It is shipped from the factory in the off position.
• Maintenance Override
One may initiate an immediate flush by placing a magnet in
front of the sensor window for one-half to three seconds. This
feature is typically used by the cleaning staff who do not wish
to stand in front of the sensor to cause actuation.
One may prevent operation of the ush valve by placing a mag-
net in front of the sensor window for longer than three seconds.
This feature is typically used by maintenance or cleaning staff
who wish to prevent automatic actuation of the valve. This
feature is automatically defeated after ten minutes.
If one wishes to defeat the feature prior to the ten-minute time out,
simply place a magnet in front of the sensor window for one-half to
three seconds.
• Indicator Light
The sensor unit includes a red indicator light having three
functions:
1. Range Adjustment: For the rst ten minutes of operation, the
red light will ash when an object is detected. See page 4.
2. Low Battery Indication: When the batteries have reached the
caution level, the red light will ash when an object is detected.
When batteries reach a lower voltage level, a double blink every 3
seconds will occur constantly.
3. Abnormal Reection Indicator: When a reective surface
is present for longer than 30 minutes, the red light will ash
indicating that an object is being continuously detected.
• Adjustable Range
The detection distance is eld adjustable from 12 to 60 inches.
Slowly rotate the range adjustment clockwise to increase range
and counterclockwise to decrease range. The range adjustment will
stop at minimum and maximum settings. Do not turn beyond these
stops. For ten minutes after battery installation, a blinking red light
in the sensor window will appear when an object is in view. For an
additional ten minutes of blinking, push the reset button. Stand in front
of the sensor and move forward and backward to determine range.
• Selectable Flush Volume
For those installations that have ideal conditions for increasing
the water conservation of both the high and low volume ush-
es, a second (red) water saving volume control is included with
the unit and can be installed at the owner’s option. The red
volume control is stored inside the housing beside the sensor.
See step 10 for the recommended evacuation test.
The new Dual Flush ZRK RetroFit Kit is the latest edition to Zurn’s EcoVantage breakthrough product offering. The ZRK-DF incorporates the
Zurn Dual Flush sensor technology which provides the utmost in water savings while ensuring a high level of sanitation and xture performance.
Zurn Dual Flush sensor technology is designed to create a higher level of water conservation by distinguishing between liquid waste or solid waste
in the bowl then supplying the appropriate ush volume to satisfy a proper evacuation of the xture.
ZRK-DF retrot kits are supplied in the ush volume set of 1.6/1.1 gallons per ush. The higher ush volume is xture compatible to evacuation
solid waste while the lower ush volume presents the opportunity of an approximate 30% water savings when evacuating liquid waste.
The determination of a high or low ush volume is based on the amount of time the user is present in front of the sensor. If the user remains in
front of the sensor for less than one minute it is assumed the user deposited liquid waste into the bowl and a low volume ush is delivered. If the
user remains in front of the sensor for longer than a minute it is assumed the user deposited solid waste in the bowl and the higher volume ush is
delivered. (One must be in the sensor’s range for at least 8 seconds to initiate the start of the timing for either the high or low ush volume.) The 8
second requirement also prevents actuation of the ush valve by a person walking by. Note: Excessive amounts of toilet paper and/or seat cover
may not evacuate during water saving liquid ush. If paper or seat cover remains in the bowl, the user will need to press the water saving green
button on the side of the unit to clear the bowl.
The ZRK-DF RetroFit Kit is also equipped with color coded manual override buttons. The black button is for the higher ush volume and the green
button is for the lower ush volume.
Zurn EcoVantage Dual Flush
The Zurn ZR DF ush valve is a water savings device. When coupled with 1.6 water conserving toilet and a proper water supply, it will provide
years of trouble free performance. When considering the Zurn ZR DF ush valve, it is important to recognize that building layout and pipe sizing
for water supplies vary signicantly from location to location. These variations can alter the end performance of a closet system dramatically.
To achieve proper performance, a minimum of 45 psi running water pressure is recommended within the one inch supply line directly behind
the ush valve and control stop. Note: Installations with running pressure below recommended value may void warranty. Please refer to our
website, www.zurn.com (search “Z6000AV-WS1-DF),for a list of recommended bowls that have been tested and proven to perform in our
laboratory environment with the ZR DF ush valve.
Optional Version Included:
Certain installations have ideal conditions where additional water savings may be achievable. A red volume control device is provided with
each ZR DF ush valve. This red volume control should be installed as outlined on page 7 of this document to achieve optimal water savings in
conformance with ASSE 1037-90 and CSA B125.3-05. Please consult our website www.zurn.com (search “Z6000AV-WS1-DF) for the most up
to date list of qualied bowls for the dual ush application. The particular bowls listed have qualied as those that provide both good evacuation
and good bowl rinse characteristics per ASME A112.19.14-2006 requirements. We continue to test bowls as they become available on the
market.
Suggested Applications: