manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. 3One data
  6. •
  7. Switch
  8. •
  9. 3One data IES206G-2GS User manual

3One data IES206G-2GS User manual

IES206G-2GS
Unmanaged Industrial Ethernet
Switch Quick Installation Guide
3onedata Co., Ltd.
Address:
3/B, Zone 1, Baiwangxin High Technology
Industrial Park, Xili, Nanshan District,
Shenzhen
Website:
www.3onedata.com
Tel:
+86 0755-26702688
Fax:
+86 0755-26703485
【Package Checklist】
Please check whether the package and accessories are intact
while using the switch for the first time.
1.
Industrial Ethernet switch
2.
Certification
3.
Quick installation guide
4.
Warranty card
5.
DIN-Rail mounting attachment
If any of these items are damaged or lost, please contact our
company or dealers, we will solve it ASAP.
【Product Overview】
The product is full Gigabit unmanaged DIN-Rail industrial
Ethernet switch. Model as follows: IES206G-2GS (2 Gigabit
SFP + 4 Gigabit copper ports).
【Panel Design】
Rear view, Top view and Bottom view
Front view and Side view
1. DIN-Rail mounting kit
2. Grounding screw
3. Power input terminal block
4. Power input status indicator P1/P2
5. Ethernet port status indicator
6. 1000Base-SFP Gigabit Ethernet SFP slot
7. 10/100/1000Base-T(X) Ethernet port
【Mounting Dimension】
Unit: mm
Attention before mounting:
Don't place or install the device in area near water or
moist, keep the relative humidity of the device
surrounding between 5%~95% without condensation.
Before power on, first confirm the supported power
supply specification to avoid over-voltage damaging the
device.
The device surface temperature is high after running;
please don't directly contact to avoid scalding.
【DIN-Rail Mounting】
For convenient usage in industrial environments, the product
adopts 35mm DIN-Rail mounting, mounting steps as below:
Check whether the DIN-Rail mounting kit thatStep 1
comes with the device is installed firmly.
Insert the bottom of DIN-Rail mounting kit (one sideStep 2 with spring support) into DIN-Rail, and then insert
the top into DIN-Rail.
Tips:
Insert a little to the bottom, lift upward and then insert
to the top.
Check and confirm the product is firmly installed onStep 3 DIN-Rail, and then mounting ends.
【Disassembling DIN-Rail】
Power off the device.Step 1 After lift the device upward slightly, first shift out theStep 2 top of DIN-Rail mounting kit, and then shift out the
bottom of DIN-Rail, disassembling ends.
Attention before powering on:
Power ON operation: first connect power line to the
connection terminal of device power supply, and then
power on.
Power OFF operation: first unpin the power plug, and
then remove the power line, please note the operation
order above.
【Power Supply Connection】
DC power supply The device provides 4 pins power
supply input terminal blocks and
two independent DC power supply
systems of PWR1 and PWR2. The
power supply supports nonpolarity
and anti-reverse connection. It can normally operate after
reverse connection. Power supply range: 24VDC (12 ~
48VDC)
【Checking LED Indicator】
The function of each LED is described in the table as below:
LED
Status
Description
P1
ON
PWR1 is connected and running
normally
OFF
PWR1 is disconnected and running
abnormally.
P2
ON
PWR2 is connected and running
normally
OFF
PWR2 is disconnected and running
abnormally
Link/ACT
(G1-G2,
1-4)
ON
Ethernet port connection is active.
Blinking
Data transmitted
OFF
Ethernet port connection is inactive.
【Specification】
Panel
Gigabit SFP
1000Base-SFP, SFP slot
Gigabit copper port
10/100/1000Base-T(X)
self-adapting RJ45 port, full/half
duplex mode, support MDI/MDI-X
self-adaption
Indicator
Power indicator, interface
indicator
Exchange attributes
Backplane bandwidth
12G
Packet buffer size
1Mbit
MAC table size
1K
Power supply
Input power supply
24VDC (12~48VDC)
Support dual power supply
redundancy, nonpolarity and
anti-reverse connection
Access terminal
4 pins 7.62mm pitch terminal
blocks
Consumption
No-load
1.44W@24VDC
Full-load
4.34W@24VDC
Environmental
Limits
Working temperature
-40~75℃
Storage temperature
-40~85℃
Working humidity
5%~95% (no condensation)
Protection grade
IP40 (metal shell)

Other 3One data Switch manuals

3One data IPS215 Series User manual

3One data

3One data IPS215 Series User manual

3One data IES716-2GS User manual

3One data

3One data IES716-2GS User manual

3One data IES318 Series User manual

3One data

3One data IES318 Series User manual

3One data ICS5400TSN-24GT16GS4XS-LN Series User manual

3One data

3One data ICS5400TSN-24GT16GS4XS-LN Series User manual

3One data SW4485 User manual

3One data

3One data SW4485 User manual

3One data TNS5800 Series User manual

3One data

3One data TNS5800 Series User manual

3One data IES5028G-4GS-8GC User manual

3One data

3One data IES5028G-4GS-8GC User manual

3One data IES5024 Series User manual

3One data

3One data IES5024 Series User manual

3One data IES7120-4GS Series User manual

3One data

3One data IES7120-4GS Series User manual

3One data IPS7110-2GC-8POE User manual

3One data

3One data IPS7110-2GC-8POE User manual

3One data IES6300 Series User manual

3One data

3One data IES6300 Series User manual

3One data ICS5400 Series User manual

3One data

3One data ICS5400 Series User manual

3One data IES205G User manual

3One data

3One data IES205G User manual

3One data SW4485I User manual

3One data

3One data SW4485I User manual

3One data IES6306 Series User manual

3One data

3One data IES6306 Series User manual

3One data IES2100SL Series User manual

3One data

3One data IES2100SL Series User manual

3One data IPS215-4POE User manual

3One data

3One data IPS215-4POE User manual

3One data IES6306 Series User manual

3One data

3One data IES6306 Series User manual

3One data TNS5500D Series User manual

3One data

3One data TNS5500D Series User manual

3One data IES5028G-4GS-8GC User manual

3One data

3One data IES5028G-4GS-8GC User manual

3One data ES5026 User manual

3One data

3One data ES5026 User manual

3One data IES3000 Series User manual

3One data

3One data IES3000 Series User manual

3One data TNS5800 Series User manual

3One data

3One data TNS5800 Series User manual

3One data IES206 Series User manual

3One data

3One data IES206 Series User manual

Popular Switch manuals by other brands

ZyXEL Communications MES-3528 - user guide

ZyXEL Communications

ZyXEL Communications MES-3528 - user guide

Verbatim 49142 Quick install guide

Verbatim

Verbatim 49142 Quick install guide

Minicom Smart 4 user guide

Minicom

Minicom Smart 4 user guide

Digi ANYWHEREUSB Product data sheet

Digi

Digi ANYWHEREUSB Product data sheet

Asante IntraCore 35516 Series user manual

Asante

Asante IntraCore 35516 Series user manual

GoMax Electronics SW-5004IZ user manual

GoMax Electronics

GoMax Electronics SW-5004IZ user manual

US Robotics USR997932 installation guide

US Robotics

US Robotics USR997932 installation guide

MINN KOTA TALON owner's manual

MINN KOTA

MINN KOTA TALON owner's manual

SCE SCE-EXR12-30T200 Installation

SCE

SCE SCE-EXR12-30T200 Installation

HP StorageWorks 64 - SAN Director Switch Cli reference guide

HP

HP StorageWorks 64 - SAN Director Switch Cli reference guide

StarTech.com IES81000POE user manual

StarTech.com

StarTech.com IES81000POE user manual

Linksys DSHUB24 Specifications

Linksys

Linksys DSHUB24 Specifications

Siemens 3KA50 operating instructions

Siemens

Siemens 3KA50 operating instructions

3Com 5500G SERIES Configuration and Command Reference Guide

3Com

3Com 5500G SERIES Configuration and Command Reference Guide

Magnetrol STI Echotel Trident 91S Instruction manual and parts list

Magnetrol

Magnetrol STI Echotel Trident 91S Instruction manual and parts list

ENER-J SHA5336-1G quick start guide

ENER-J

ENER-J SHA5336-1G quick start guide

Stahl 8060/2 Series manual

Stahl

Stahl 8060/2 Series manual

Exsys EX-1184HMVS-2 manual

Exsys

Exsys EX-1184HMVS-2 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.