manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. 3One data
  6. •
  7. Switch
  8. •
  9. 3One data IES206G-2GS User manual

3One data IES206G-2GS User manual

Other 3One data Switch manuals

3One data TNS5800 Series User manual

3One data

3One data TNS5800 Series User manual

3One data IES1028 Series User manual

3One data

3One data IES1028 Series User manual

3One data IES618 Series User manual

3One data

3One data IES618 Series User manual

3One data ICS6420 Series User manual

3One data

3One data ICS6420 Series User manual

3One data TNS5800D Series User manual

3One data

3One data TNS5800D Series User manual

3One data ES209G-1GF User manual

3One data

3One data ES209G-1GF User manual

3One data IES205G User manual

3One data

3One data IES205G User manual

3One data IPS7112G-4GS-8GPOE User manual

3One data

3One data IPS7112G-4GS-8GPOE User manual

3One data IES615-2DI(3IN1) Series User manual

3One data

3One data IES615-2DI(3IN1) Series User manual

3One data IES2220 Series User manual

3One data

3One data IES2220 Series User manual

3One data IES618-4D Series User manual

3One data

3One data IES618-4D Series User manual

3One data IES716-2GS User manual

3One data

3One data IES716-2GS User manual

3One data IES3016L Series User manual

3One data

3One data IES3016L Series User manual

3One data IES2210 Series User manual

3One data

3One data IES2210 Series User manual

3One data IES6210 Series User manual

3One data

3One data IES6210 Series User manual

3One data TNS5800-8GP16GT-P24VDC User manual

3One data

3One data TNS5800-8GP16GT-P24VDC User manual

3One data TNS5500 Series User manual

3One data

3One data TNS5500 Series User manual

3One data TNS5800 Series User manual

3One data

3One data TNS5800 Series User manual

3One data IES6116 Series User manual

3One data

3One data IES6116 Series User manual

3One data IPS7110-2GC-8POE User manual

3One data

3One data IPS7110-2GC-8POE User manual

3One data IES206 Series User manual

3One data

3One data IES206 Series User manual

3One data IPS215 Series User manual

3One data

3One data IPS215 Series User manual

3One data IES618 Series User manual

3One data

3One data IES618 Series User manual

3One data IPS7112G-4GS-8GPOE User manual

3One data

3One data IPS7112G-4GS-8GPOE User manual

Popular Switch manuals by other brands

SMC Networks SMC6224M Technical specifications

SMC Networks

SMC Networks SMC6224M Technical specifications

Aeotec ZWA003-S operating manual

Aeotec

Aeotec ZWA003-S operating manual

TRENDnet TK-209i Quick installation guide

TRENDnet

TRENDnet TK-209i Quick installation guide

Planet FGSW-2022VHP user manual

Planet

Planet FGSW-2022VHP user manual

Avocent AutoView 2000  AV2000BC AV2000BC Installer/user guide

Avocent

Avocent AutoView 2000 AV2000BC AV2000BC Installer/user guide

Moxa Technologies PT-7728 Series user manual

Moxa Technologies

Moxa Technologies PT-7728 Series user manual

Intos Electronic inLine 35392I operating instructions

Intos Electronic

Intos Electronic inLine 35392I operating instructions

Cisco Catalyst 3560-X-24T Technical specifications

Cisco

Cisco Catalyst 3560-X-24T Technical specifications

Asante IntraCore IC3648 Specifications

Asante

Asante IntraCore IC3648 Specifications

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Siemens

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Edge-Core DCS520 quick start guide

Edge-Core

Edge-Core DCS520 quick start guide

RGBLE S00203 user manual

RGBLE

RGBLE S00203 user manual

Thrustmaster FLIGHT SIMULATOR X quick guide

Thrustmaster

Thrustmaster FLIGHT SIMULATOR X quick guide

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Southwire

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Buhler Nivotemp NT 61 Brief instructions

Buhler

Buhler Nivotemp NT 61 Brief instructions

Kramer VS-41HDCP user manual

Kramer

Kramer VS-41HDCP user manual

Techly IDATA AU-270 user manual

Techly

Techly IDATA AU-270 user manual

Belkin F1U109 user manual

Belkin

Belkin F1U109 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

IES206G-2GS
Unmanaged Industrial Ethernet
Switch Quick Installation Guide
3onedata Co., Ltd.
Address:
3/B, Zone 1, Baiwangxin High Technology
Industrial Park, Xili, Nanshan District,
Shenzhen
Website:
www.3onedata.com
Tel:
+86 0755-26702688
Fax:
+86 0755-26703485
【Package Checklist】
Please check whether the package and accessories are intact
while using the switch for the first time.
1.
Industrial Ethernet switch
2.
Certification
3.
Quick installation guide
4.
Warranty card
5.
DIN-Rail mounting attachment
If any of these items are damaged or lost, please contact our
company or dealers, we will solve it ASAP.
【Product Overview】
The product is full Gigabit unmanaged DIN-Rail industrial
Ethernet switch. Model as follows: IES206G-2GS (2 Gigabit
SFP + 4 Gigabit copper ports).
【Panel Design】
Rear view, Top view and Bottom view
Front view and Side view
1. DIN-Rail mounting kit
2. Grounding screw
3. Power input terminal block
4. Power input status indicator P1/P2
5. Ethernet port status indicator
6. 1000Base-SFP Gigabit Ethernet SFP slot
7. 10/100/1000Base-T(X) Ethernet port
【Mounting Dimension】
Unit: mm
Attention before mounting:
Don't place or install the device in area near water or
moist, keep the relative humidity of the device
surrounding between 5%~95% without condensation.
Before power on, first confirm the supported power
supply specification to avoid over-voltage damaging the
device.
The device surface temperature is high after running;
please don't directly contact to avoid scalding.
【DIN-Rail Mounting】
For convenient usage in industrial environments, the product
adopts 35mm DIN-Rail mounting, mounting steps as below:
Check whether the DIN-Rail mounting kit thatStep 1
comes with the device is installed firmly.
Insert the bottom of DIN-Rail mounting kit (one sideStep 2 with spring support) into DIN-Rail, and then insert
the top into DIN-Rail.
Tips:
Insert a little to the bottom, lift upward and then insert
to the top.
Check and confirm the product is firmly installed onStep 3 DIN-Rail, and then mounting ends.
【Disassembling DIN-Rail】
Power off the device.Step 1 After lift the device upward slightly, first shift out theStep 2 top of DIN-Rail mounting kit, and then shift out the
bottom of DIN-Rail, disassembling ends.
Attention before powering on:
Power ON operation: first connect power line to the
connection terminal of device power supply, and then
power on.
Power OFF operation: first unpin the power plug, and
then remove the power line, please note the operation
order above.
【Power Supply Connection】
DC power supply The device provides 4 pins power
supply input terminal blocks and
two independent DC power supply
systems of PWR1 and PWR2. The
power supply supports nonpolarity
and anti-reverse connection. It can normally operate after
reverse connection. Power supply range: 24VDC (12 ~
48VDC)
【Checking LED Indicator】
The function of each LED is described in the table as below:
LED
Status
Description
P1
ON
PWR1 is connected and running
normally
OFF
PWR1 is disconnected and running
abnormally.
P2
ON
PWR2 is connected and running
normally
OFF
PWR2 is disconnected and running
abnormally
Link/ACT
(G1-G2,
1-4)
ON
Ethernet port connection is active.
Blinking
Data transmitted
OFF
Ethernet port connection is inactive.
【Specification】
Panel
Gigabit SFP
1000Base-SFP, SFP slot
Gigabit copper port
10/100/1000Base-T(X)
self-adapting RJ45 port, full/half
duplex mode, support MDI/MDI-X
self-adaption
Indicator
Power indicator, interface
indicator
Exchange attributes
Backplane bandwidth
12G
Packet buffer size
1Mbit
MAC table size
1K
Power supply
Input power supply
24VDC (12~48VDC)
Support dual power supply
redundancy, nonpolarity and
anti-reverse connection
Access terminal
4 pins 7.62mm pitch terminal
blocks
Consumption
No-load
1.44W@24VDC
Full-load
4.34W@24VDC
Environmental
Limits
Working temperature
-40~75℃
Storage temperature
-40~85℃
Working humidity
5%~95% (no condensation)
Protection grade
IP40 (metal shell)