TNS5800D 20-Port Series
Layer 3 Wall Mounting
Industrial Ethernet Switch
Quick Installation Guide
3onedata Co., Ltd.
Address: 3/B, Zone 1, Baiwangxin High Technology
Industrial Park, Xili, Nanshan District,
Shenzhen
Website: www.3onedata.com
Te l : +86 0755-26702688
Fax: +86 0755-26703485
【Package Checklist】
Please check the integrity of package and accessories while
first using the switch.
1
Switch ×1
2
Warranty card
3
Certificate
If any of these items are damaged or lost, please contact our
company or dealers, we will solve it ASAP.
【Product Overview】
This series of product islayer-3 wall-mounted industrial
Ethernet switch. For convenience, the products of this series
adopt the following number on the left in this guide, please
affirm the number of your product.
Model I. TNS5800D-20GT-P110 (20 Gigabit M12, 110VDC
power input).
Model II. TNS5800D-16T4GT-P110 (16 100M M12 + 4
Gigabit M12, 110VDC power input).
Model III. TNS5800D-16T4GT-P24 (16 100M M12 + 4
Gigabit M12, 24VDC power input).
Model IV. TNS5800D-16GP4GT-P110 (16 Gigabit PoE M12
+ 4 Gigabit M12, 110VDC power input).
Model V. TNS5800D-16P4GT-P110 (16 100M PoE M12 + 4
Gigabit M12, 110VDC power input).
Model VI. TNS5800D-16P4GT-P24 (16 100M PoE M12 + 4
Gigabit M12, 24VDC power input).
【Panel Design】
Model II, III Front View
1. Power supply indicator (P1-P2)
2. Alarm indicator (ALM)
3. Running indicator (RUN)
4. Lugs
5. Relay alarm output interface
6. Grounding screw
7. CONSOLE port
8. Power input interface (P1-P2)
9. Gigabit Bypass M12 interface (Bypass: G1-G2,
G3-G4)
10. 100M Ethernet port (E1-E16)
11. Ethernet port indicator (E1-E16, G1-G20)
Model I, IV, V, VI Front View
Model I
Model IV
Model V, VI
1. Power supply indicator (P1-P2)
2. Alarm indicator (ALM)
3. Running indicator (RUN)
4. Lugs
5. Relay alarm output interface
6. Grounding screw
7. CONSOLE port
8. Power input interface (P1-P2)
9. Gigabit Bypass M12 interface (Bypass: G1-G2,
G3-G4)
10. PoE indicator (E1-E16)
11. 100M PoE M12 interface (E1-E16)
12. Ethernet port indicator (E1-E16, G1-G4)
13. Gigabit Bypass M12 interface (Bypass: G17-G18,
G19-G20)
14. PoE indicator (G1-G16)
15. Gigabit PoE M12 interface (G1-G16)
16. Ethernet port indicator (G1-G20)
【Mounting Dimension】
Unit: mm
Notice Before Mounting:
Don't place or install the device in area near water or
moist, keep the relative humidity of the device
surrounding between 5%~95% without condensation.
Before power on, first confirm the supported power
supply specification to avoid over-voltage damaging the
device.
The device surface temperature is high after running;
please don't directly contact to avoid scalding.
【Wall-mounted Device Mounting】
Step 1. On the wall of device mounting, place the device on
the wall for reference or refer to the mounting
dimension to mark two screw positions.
Step 2. Nail screws on the wall and keep 7mm interspace
reserved.
Step 3. Hang the device on 4 screws and slide downward,
then tighten the screw. Mounting ends.
【Wall-mounted Device Disassembling】
Power off the device.
Unscrew the screw on the wall about 7mm.
Lift the device upward slightly; take out the device,
disassembling ends.
Notice before power on:
Power ON operation: First insert the power supply
terminal block into the device power supply interface,
then plug the power supply plug contact and power on.
Power OFF operation: First, remove the power plug,
then remove the wiring section of terminal block. Please
pay attention to the above operation sequence.
【Power Supply Connection】
110VDC power supply
The Model I, II, IV and V of this series device
provide two independent DC power supply inputs,
which support reverse connection protection and
power redundancy backup. The power supply interface adopts
M12 A-Coded 4-Pin pin (male) connector. Power supply input
range: 110VDC (66~156VDC). The pin definitions of M12
(male) are shown as follows:
Pin No.
1
2
3
4
Pin Definition
V1+
V2+
V1-
V2-
24VDC power supply
The Model III, VI of this series device provide two independent
DC power supply inputs, which support reverse connection
protection and power redundancy backup. The power supply
interface adopts M12 A-Coded 4-Pin pin (male) connector.
The pin definitions of M12 (male) are shown as follows:
Model III power supply input range: 24VDC (9~36VDC).
Model VI power supply input range: 24VDC
(18~36VDC).
Pin No.
1
2
3
4
Pin Definition
V1+
V2+
V1-
V2-
【Relay Connection】
Provide 1 M12 D-Coded 4-Pin slot (female) that
supports 1 relay alarm output. R1 and R2 are a set of
normally open contacts of the device alarm relay. They are
open circuit in the state of normal non alarm, closed when any
alarm information occurs. For example, they are closed when
powered off, and send out alarm. The relay supports the
output of DC power supply alarm information or network
abnormality alarm. It can be connected to alarm light or alarm
buzzer or other switching value collecting devices, which can
timely inform operators when the alarm occurs. The pin
definitions of relay are shown as follows:
Pin No.
1
2
3
4
Pin Definition
R1
R2
NC
NC
【Console Port Connection】
Provide 1 program debugging port based on RS232
serial port which can conduct device CLI command
management after connecting to PC. The interface
adopts M12 D-Coded 4-Pin slot (female). The pin definitions
of M12 are shown as follows:
Pin No.
1
2
3
4
Pin Definition
TX-
RX-
NC
GND
【Communication Interface Connection】
100M M12 Interface
Provide 10/100Base-T(X) interface, the interface
type is M12 D-Coded 4-Pin slot (female). The
definitions of M12 pin are as follows:
Pin No. Pin Definition Description
1 TX+ Positive send data of 100M
Ethernet
2 RX+ Positive receive data of
100M Ethernet
3 TX- Negative send data of 100M
Ethernet
4 RX- Negative receive data of
100M Ethernet
Gigabit M12 interface
This device provides 10/100/1000Base-T(X)
interfaces, the interface type is M12 X-Coded
8-Pin slot (female). The definitions of M12 pin are
as follows:
Pin No. Pin Definition Description
1 D0+ (DA+) Positive bi-directional data of
Gigabit Ethernet group 1
2 D0- (DA-) Negative bi-directional data
of Gigabit Ethernet group 1
3 D1+ (DB+) Positive bi-directional data of
Gigabit Ethernet group 2
4 D1- (DB-) Negative bi-directional data
of Gigabit Ethernet group 2
Pin No. Pin Definition Description
5 D3+ (DD+) Positive bi-directional data of
Gigabit Ethernet group 4
6 D3- (DD-) Negative bi-directional data
of Gigabit Ethernet group 4
7 D2- (DC-) Negative bi-directional data
of Gigabit Ethernet group 3
8 D2+ (DC+) Positive bi-directional data of
Gigabit Ethernet group 3
【Checking LED Indicator】
The device provides LED indicators to monitor its operating
status, which has simplified the overall troubleshooting
process. The function of each LED is described in the table
below:
LED
Indicate
Description
P1/P2
ON P1/2 is connected and running
normally
OFF P1/2 is disconnected and running
abnormally
ALM
ON
Power supply or port link has alarm
OFF Power supply or port link has no
alarm
RUN
ON
The device is powering on or the
device is abnormal.
OFF
The device is powered off or the
device is abnormal.
Blinking Blinking 1 time per second, system
is running normally
LINK
(E1-E16,
G1-G20)
ON
Ethernet port has established a
valid network connection
Blinking
Ethernet port is in an active
network status
OFF
Ethernet port has not established
valid network connection
POE
(E1-E16,
ON
POE port is powering other PD
devices normally
LED
Indicate
Description
G1-G16) OFF POE port is not powering other PD
devices
【Logging in to WEB Interface】
This device supports WEB management and configuration.
Computer can access the device via Ethernet interface. The
way of logging in to device’s configuration interface via IE
browser is shown as below:
Configure the IP addresses of computer and the
device to the same network segment, and the
network between them can be mutually accessed.
Enter device’s IP address in the address bar of the
computer browser.
Enter device’s username and password in the login
window as shown below.
Click “Login” button to login to the WEB interface of
the device.
Note:
The default IP address of the device is “192.168.1.254”.
The default username and password of the device are
“admin123”.
If the username or password is lost, user can restore it to
factory settings via management software; all modified
configurations will be cleared after restoring to factory
settings, so please backup configuration file in advance.
Please refer to user manual for specific configuration
method of logging in to WEB interface and other
configurations about network management function.
【Specification】
Panel
Gigabit PoE
M12
10/100/1000Base-T(X), M12 (Female),
8-Pin X-Coded, automatic flow rate
control, full/half duplex mode,
MDI/MDI-X autotunning; The maximum
capacity of a single port is 30W PoE
power supply output. Pin 1 and 2 of PoE
power supply are positive, while pin 3
and 4 are negative
Gigabit M12
LAN Port
10/100/1000Base-T(X), M12(Female),
8-Pin X-Coded, Automatic Flow Control,
Full/half Duplex Mode, MDI/MDI-X
Autotunning; support two groups of
Bypass
100M PoE M12 10/100base-T(X), M12 (Female), 4-Pin
D-Coded, automatic flow control,
full/half duplex mode, MDI/MDI-X
automatic detection; The single port
supports up to 30W PoE power supply
output. Pin 1 and 3 of PoE power supply
are positive, while pin 2 and 4 are
negative
100M M12 10/100Base-T(X), M12(Female), 4-Pin
D-Coded, Automatic Flow Control,
Full/half Duplex Mode, MDI/MDI-X
Autotunning
Console port CLI command line management port
(RS-232), M12(Female), 4-Pin D-Coded
Alarm interface M12 (Female), 4-Pin D-Coded, support
1 relay alarm output, current load
capability is 1A@30VDC or
0.3A@125VAC
Indicator Power indicator, alarm indicator, running
indicator, interface indicator
Switch Property
Backplane
bandwidth
128G
Packet buffer
size
12Mbit
MAC Address
Table
16K
Power supply
Model I, Model
II, Model IV,
Model V
110VDC(66~156VDC)
Support reverse connection protection
Model III 24VDC(9~36VDC)
Support reverse connection protection
Model VI 24VDC(18~36VDC)
Support reverse connection protection
Connection
Mode
M12(Male), 4-Pin A-Coded
Power consumption
Full-load(without
PoE)
<20W
Full-load(with
PoE)
<120W
Working Environment
Working
temperature
-40~75℃
Storage
temperature
-40~85℃
Working
humidity
5%~95% (no condensation)
Protection grade
IP67(metal shell)
【Disposal of Waste Electrical and Electronic
Equipment (WEEE 2012/19/EU)】
(Applicable in the EU-member states)
The crossed-out wheeled bin symbol on the equipment or its
packaging indicates that the product, at the end of its service
life, shall not be mixed with unsorted municipal waste but
should be collected
separately, in accordance
with local laws and
regulations.
A proper separate collection
of end-of-life equipment for
the subsequent recycling,
treatment and
environmentally compatible
disposal, will help prevent
potential damage to the
environment and human health, facilitating the reuse,
recycling and/or recovery of its component materials.
Private users should contact their vendor or municipal waste
management service and ask for disposal information.
Professional users should contact their suppliers and check
the terms of their selling agreement.
This product must not be disposed of with other commercial
waste.
Users’ cooperation in the correct disposal of this product will
contribute to saving valuable resources and protecting the
environment.

Other 3One data Switch manuals

3One data IES6100PN-8T-2LV User manual

3One data

3One data IES6100PN-8T-2LV User manual

3One data TNS5000D Series User manual

3One data

3One data TNS5000D Series User manual

3One data TNS5800-8GP16GT-P24VDC User manual

3One data

3One data TNS5800-8GP16GT-P24VDC User manual

3One data IES5024-P User manual

3One data

3One data IES5024-P User manual

3One data ES1008G-8POE-150W-P User manual

3One data

3One data ES1008G-8POE-150W-P User manual

3One data IES6306 Series User manual

3One data

3One data IES6306 Series User manual

3One data IES5328 Series User manual

3One data

3One data IES5328 Series User manual

3One data PS5026G-2GS-24PoE User manual

3One data

3One data PS5026G-2GS-24PoE User manual

3One data IPS7110-2GC-4POE Series User manual

3One data

3One data IPS7110-2GC-4POE Series User manual

3One data TNS5800 Series User manual

3One data

3One data TNS5800 Series User manual

3One data PS5026G-2GS-24PoE Operating and maintenance instructions

3One data

3One data PS5026G-2GS-24PoE Operating and maintenance instructions

3One data IES2220 Series User manual

3One data

3One data IES2220 Series User manual

3One data IES618 Series User manual

3One data

3One data IES618 Series User manual

3One data IES5024 Series User manual

3One data

3One data IES5024 Series User manual

3One data ES5018 User manual

3One data

3One data ES5018 User manual

3One data IPS7112G-4GS-8POE User manual

3One data

3One data IPS7112G-4GS-8POE User manual

3One data IES618-4D Series User manual

3One data

3One data IES618-4D Series User manual

3One data IES2016-16T Series User manual

3One data

3One data IES2016-16T Series User manual

3One data IES3016L Series User manual

3One data

3One data IES3016L Series User manual

3One data TNS5500D Series User manual

3One data

3One data TNS5500D Series User manual

3One data IES5028 Series User manual

3One data

3One data IES5028 Series User manual

3One data IES7116G-8GS Series User manual

3One data

3One data IES7116G-8GS Series User manual

3One data IES6300 Series User manual

3One data

3One data IES6300 Series User manual

3One data IES1028 Series User manual

3One data

3One data IES1028 Series User manual

Popular Switch manuals by other brands

Intellinet IES-48GM04 instructions

Intellinet

Intellinet IES-48GM04 instructions

Compaq EO1002 user guide

Compaq

Compaq EO1002 user guide

GET GPA Guide

GET

GET GPA Guide

Next Level f-gt simulator cockpit instruction manual

Next Level

Next Level f-gt simulator cockpit instruction manual

Wöhner QUADRON 60Classic Speed manual

Wöhner

Wöhner QUADRON 60Classic Speed manual

T3 77562 user guide

T3

T3 77562 user guide

Allen-Bradley 440G-TZS21UPRH installation instructions

Allen-Bradley

Allen-Bradley 440G-TZS21UPRH installation instructions

Enterasys RoamAbout RBT-8100 installation guide

Enterasys

Enterasys RoamAbout RBT-8100 installation guide

Edge-Core DCS520 quick start guide

Edge-Core

Edge-Core DCS520 quick start guide

Belkin F1U109 user manual

Belkin

Belkin F1U109 user manual

Bones TWIN-CITY AB/Y owner's manual

Bones

Bones TWIN-CITY AB/Y owner's manual

Vertiv AutoView AV104 Installer/user guide

Vertiv

Vertiv AutoView AV104 Installer/user guide

Helmholz 700-841-16S01 instruction manual

Helmholz

Helmholz 700-841-16S01 instruction manual

Axis T8504-R manual

Axis

Axis T8504-R manual

Acuity Brands Sensor Switch WSX Series quick start guide

Acuity Brands

Acuity Brands Sensor Switch WSX Series quick start guide

Process Technology DLC16 manual

Process Technology

Process Technology DLC16 manual

EMP-Centauri MS5/5+12ECP5dB-4 instruction manual

EMP-Centauri

EMP-Centauri MS5/5+12ECP5dB-4 instruction manual

ATEN US3312 user manual

ATEN

ATEN US3312 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.