ACME ENERGY SPOT XA-400 SPOT User manual

XA-400 SPOT PRO
User Manual
Please read the instruction carefully before use

CONTENTS
1. Safety Instructions..........................................................................................2
2. Technical Specifications..................................................................................3
3. How To Set The Unit.......................................................................................4
3.1 Control panel ..........................................................................................4
3.2 Main Function.........................................................................................5
4. Control By Universal DMX Controller ...........................................................13
4.1 DMX Connection...................................................................................13
4.2 Address Setting .....................................................................................14
4.3 DMX 512 Configuration.........................................................................14
5. Troubleshooting ...........................................................................................29
6. Fixture Cleaning ...........................................................................................29
1B

1. Safety Instructions
WARNING
Please keep this User Guide for future consultation. If you sell the unit to another user, be sure
that they also receive this instruction booklet.
Unpack and check carefully there is no transportation damage before using the unit.
Before operating, ensure that the voltage and frequency of power supply match the power
requirements of the unit.
It’s important to ground the yellow/green conductor to earth in order to avoid electric shock.
The unit is for indoor use only. Use only in a dry location.
The unit must be installed in a location with adequate ventilation, at least 50cm from adjacent
surfaces. Be sure that no ventilation slots are blocked.
Disconnect main power before replacement or servicing.
Make sure there are no flammable materials close to the unit while operating as it is fire hazard.
Use safety cable when fixes this unit. DO NOT handle the unit by taking its head only, but always
by taking its base.
Maximum ambient temperature is Ta: 40℃. DO NOT operate it where the temperature is higher
than this.
Unit surface temperature may reach up to 85℃. DO NOT touch the housing bare-hand during its
operation. Turn off the power and allow about 15 minutes for the unit to cool down before
replacing or serving.
In the event of serious operating problem, stop using the unit immediately. Never try to repair
the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction.
Please contact the nearest authorized technical assistance center. Always use the same type
spare parts.
DO NOT touch any wire during operation as high voltage might be causing electric shock.
Warning:
To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or
Please read carefully the instruction, which includes
important information about the installation, usage and
2B

moisture.
DO NOT open the unit within five minutes after switching off.
The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly damaged.
Caution:
There are no user serviceable parts inside the unit. DO NOT open the housing or attempt any
repairs yourself. In the unlikely event your unit may require service, please contact your nearest
dealer.
Installation:
The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is
firmly fixed to avoid vibration and slipping while operating. And make sure that the structure to
which you are attaching the unit is secure and is able to support a weight of 10 times of the unit’s
weight. Also always use a safety cable that can hold 12 times of the weight of the unit when
installing the fixture.
The equipment must be fixed by professionals. And it must be fixed at a place where is out of the
touch of people and has no one pass by or under it.
2. Technical Specifications
DMX Channels: 18/22/25 channel mode
Color display for easy navigation
Voltage:
Power consumption:
LED:
Fuse:
Beam Angle:
Dimension:
Weight:
AC 100V~240V, 50/60Hz
455W
1 x 270W LED
T10A
8°-45°
430 x 254 x 64mm
20 Kgs
368.9mm
625.4mm
207.3mm
3B

Photometrics Diagram
Distance(m)
5 10 15 20
8° Lux 32000
7800
3300 1750
Diameter(m) 0. 2714. 5 21.7
8° 45°
45° Lux 147 470 230 130
Diameter(m) 41. 1 .321.64
8.2
2 91.
3. How To Set The Unit
3.1 Control panel
567
12
43
1. LED:
POWER On Power On
DMX On DMX input present
2. Button:
MENU
To select the programming functions
UP
To go forward in the selected functions
DOWN
To go backward in the selected functions
4B

ENTER
To confirm the selected functions
3. Function Display: Used to show the various menus and the selected function;
4. Fireware Upgrade
5. DMX IN/OUT: DMX 512 link, use XLR cable to link the unit and DMX controller;
6. FUSE (T6.3Amp): Protect the unit from damage of the overcurrent;
7. POWER IN: Connect to power supply.
3.2 Main Function
To select any of the given functions, press the MENU button up to when the required one is
showing on the display. Select the function by the ENTER button and the display will blink. Use the
DOWN and UP button to change the mode. Once the required mode has been selected, press the
ENTER button to setup, to go back to the functions without any change press the MENU button
again. Hold and press the MENU button about one second or wait for one minute to exit the menu
mode.
The main functions are showing below:
5B

512
1
1~10
℃ ℉
/
Fixture Setting
1-9999
MENU
DMX Functions
Display Setting
FixtureText
Fixture Information
Reset Functions
Special Functions
DMX Address
DMX Channel Mode
DMX State
Pan Inverse
Tilt Inverse
PTFeedback
Dimmer Curve
Dimmer Speed
Focus Compensate
Liner
Square law
Inv SQ law
S Curve
Fast
Smooth
Disable
Near
Medium
Far
Display Inverse
Backlight Intensit
Temperature Unit
Language
English
Chinese
AutoTest
ManualTest
Fixture Use Time
Temperature
USB Upgrade File
Pan Tilt
Effect
Factory Setting No
Yes
No
Yes
No
Yes
Mode1(18)
Mode2(22)
Mode3(25)
Blackout
Hold
No
Yes
Firmware Version
View DMX Value
6B

DMX Settings
To select DMX Settings press the ENTER button to confirm, use the UP/DOWN button to
select DMX Address, DMX Channel Mode or DMX State
,
View DMX Value.
DMX Address —DMX512 address setting
To select DMX Address, press the ENTER button to confirm. Use the UP/DOWN button to
adjust the address from 001 to 512, press the ENTER button to store. Press the MENU button
back to the last menu or let the unit idle one minute to exit menu mode.
DMX Channel Mode
To select DMX Channel Mode, press the ENTER button to confirm. Use the UP/DOWN button
to select Mode 1(18),Mode 2(22) or Mode 2(25) press the ENTER button to store. Press the
MENU button back to the last menu or let the unit idle one minute to exit menu mode
DMX State —fixture state while DMX single stops
To select DMX State, press the ENTER button to confirm. Use the UP/DOWN button to select
Blackout (fixture blacks out if DMX signal stops) or Hold (fixture continues to obey the last
command it received Via DMX if DMX signal stops), press the ENTER button to store. Press the
MENU button back to the last menu or let the unit idle one minute to exit menu mode.
View DMX Value
To select View DMX Value, press the ENTER button to confirm. Use the UP/DOWN button to
view the DMX channel value. Press the MENU button back to the last menu or let the unit idle
one minute to exit menu mode.
Fixture Settings
To select Fixture Settings, press the ENTER button to confirm, use the UP/DOWN button to select
Pan Inverse, Tile Inverse, P/T Feedback,Dimmer Curve , Dimmer Speed or Focus Compensate.
Pan Inverse
To select Pan Inverse, press the ENTER button to confirm. Use the UP/DOWN button to select
No (normal) or Yes (pan inverse), press the ENTER button to store. Press the MENU button
back to the last menu or let the unit idle one minute to exit menu mode.
Tilt Inverse
To select Tilt Inverse, press the ENTER button to confirm. Use the UP/DOWN button to select
7B

No (normal) or Yes (tilt inverse), press the ENTER button to store. Press the MENU button back
to the last menu or let the unit idle one minute to exit menu mode.
P/T Feedback
To select P/T Feedback, press the ENTER button to confirm. Use the UP/DOWN button to
select No (Pan or tilt’s position will not feedback while out of step) or Yes (Feedback while
pan/tilt out of step), press the ENTER button to store. Press the MENU button back to the last
menu or let the unit idle one minute to exit menu mode.
Dimmer Curve
To select Dimmer Curve, press the ENTER button to confirm. Use the DOWN/UP button to
select the Linear(Mode1) or Square law (Mode 2) o Inv SQ law (Mode 3) or S Curve (Mode
4). Once the mode has been selected, press the ENTER button to setup, to go back to the
functions without any change press the MENU button again. Press and hold the MENU button
about one second or wait for one minute to exit the menu mode.
Dimmer Speed
To select Dimmer Speed , press the ENTER button to confirm. Use the DOWN/UP button to
select the Fast or Smooth. press the ENTER button to store. Press the MENU button back to
the last menu or let the unit idle one minute to exit menu mode.
Focus Compensate
To select Focus Compensate , press the ENTER button to confirm. Use the DOWN/UP
button to select the Disable , Near ,Medium or Far. Once the mode has been selected, press
the ENTER button to setup, to go back to the functions without any change press the MENU
button again. Press and hold the MENU button about one second or wait for one minute to
exit the menu mode.
8B

Mode 1(Optically Linear):
The increase in light intensity appears to be linear as DMX value is increased.
Mode 2(Square Law):
Light intensity control is finer at low levels and coarser at high levels.
Mode 3(Inverse Square Law):
Light intensity control is coarser at low levels and finger at high levels.
Mode 4(S-cure):
Light intensity control is finger at low levels and high levels and coarser at medium levels.
Display Settings
Enter menu mode, select Display Setting, press the ENTER button to confirm, use the
UP/DOWN button to select Display Inverse, Backlight Intensity, Temperature Unit or
Language.
Display Inverse
Select Display Inverse, press the ENTER button to confirm, present mode will blink on the
display, use the UP/DOWN button to select No (normal display) or Yes (inverse display), press
the ENTER button to store. Press the MENU button back to the last menu or let the unit idle
one minute to exit menu mode.
Backlight Intensity
Select Backlight Intensity, press the ENTER button to confirm, present mode will blink on the
display, use the UP/DOWN button to adjust backlight intensity from 1 (dark) to 10 (bright),
press the ENTER button to store. Press the MENU button back to the last menu or let the unit
idle one minute to exit menu mode.
Temperature Unit
9B

Select Temperature Unit, press the ENTER button to confirm, present mode will blink on the
display, use the UP/DOWN button to select
℃
or
℉
, press the ENTER button to store. Press
the MENU button back to the last menu or let the unit idle one minute to exit menu mode.
Language
To select Language , press the ENTER button to confirm, present mode will blink on the display,
use the UP/DOWN button to select English or Chinese, press the ENTER button to store. Press
the MENU button back to the last menu or let the unit idle one minute to exit menu mode.
F ixture Test
Enter menu mode, select Fixture Test, press the ENTER button to confirm, use the UP/DOWN
button to select Auto Test or Manual Test
Auto Test
Select Auto Test, press the ENTER button to confirm, the unit will run built-in programs to
automatically test pan, tilt, shutter, color, CMY, gobo, gobo rotation, prism, prism rotation, iris,
frost, zoom, focus, dimmer and lamp on/off. Press the MENU button back to the last menu or
exit menu mode after auto test.
Manual Test
Select Manual Test, press the ENTER button to confirm, the present channel will show on the
display, use the UP/DOWN button to select channel, press the ENTER button to confirm, then
use the UP and DOWN button to adjust the value, press the ENTER button to store, the fixture
will run as the channel value indicates. Press the MENU button back to the last menu or exit
menu mode idling one minute.
(All channels value will become 0 after exiting Manual Test menu)
Fixture Information
Enter menu mode, select Fixture Information, press the ENTER button to confirm, use the
UP/DOWN button to select Fixture use time, Temperature ,USB upgrade File or Firmware
Version.
Fixture use hour
Select Fixture use hour, press the ENTER button to confirm, fixture use time will show on the
10B

display, press the MENU button to exit.
Temperature
Select Temperature, press the ENTER button to confirm, fixture temperature will show on the
display, press the MENU button to exit.
USB upgrade File
Select Firmware Version, press the ENTER button to confirm, firmware version will show on
the display, press the MENU button back to exit.
Firmware Version
Select Firmware Version, press the ENTER button to confirm, firmware version will show on
the display, press the MENU button back to exit.
Reset Functions
Enter menu mode, select Reset Function, press the ENTER button to confirm, use the
UP/DOWN button to select Pan/Tilt, Effect or All.
Pan
﹠
Tilt —Reset Pan/Tilt
Select Pan
﹠
Tilt, press the ENTER button to confirm, use the UP/DOWN button to select Yes
(the unit will run built-in program to reset pan and tilt to their home positions) or No(normal),
press the ENTER button to store. Press the MENU button back to the last menu or let the unit
idle one minute to exit menu mode.
Effect —Reset Effect
Select Effect, press the ENTER button to confirm, use the UP/DOWN button to select Yes (the
unit will run built-in program to reset effect to their home positions) or No, press the ENTER
button to store. Press the MENU button back to the last menu or let the unit idle one minute
to exit menu mode
All — Reset All
Select All, press the ENTER button to confirm, use the UP/DOWN button to select Yes (the
unit will run built-in program to reset all motors to their home positions) or No, press ENTER
button to store. Press the MENU button to exit.
Special Functions
11B

Factory Settings
Select Factory Settings,press the ENTER button to confirm, use the UP/DOWN button to
select Yes (the fixture will reset to factory settings)or No (normal), press ENTER button to
store. Press the MENU button to exit.
5.2 Home Position Adjustment
Press the MENU button into menu mode, then press the ENTER button for about 3 seconds into
offset mode to adjust the home position. Select the function by the ENTER button. Use the
UP/DOWN button to choose the submenu, press the ENTER button to store and automatically
return to the last menu. Press MENU button to exit.
Pan
Tilt
Color 1
Gobo 1
Rgobo 1
Gobo 2
Prism1
Rprism1
Iris
Forst
Focus
-128
127
Cyan
Magenta
Yellow
Zoom
12B

4. Control By Universal DMX Controller
4.1 DMX Connection
DMX Out
1. Connect the fixture together in a “daisy chain” by XLR plug cable from the output of the fixture
to the input of the next fixture. The cable cannot be branched or split to a “Y” cable.
Inadequate or damaged cables, soldered joints or corroded connectors can easily distort the
signal and shut down the system
2. The DMX output and input connectors are pass-through to maintain the DMX circuit when one
of the units’ power is disconnected.
3. At last fixture, the DMX cable has to be terminated with a terminator to reduce signal errors.
Solder a 120-ohm 1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug
and plug it in the DMX-output of the last fixture.
4. Each lighting fixture needs to have an address set to receive the data sent by the controller.
The address number is between 0-511 (usually 0 & 1 are equal to 1).
5. 3 pin XLR connectors are more popular than 5 pins XLR.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
13B

4.2 Address Setting
If you use a universal DMX controller to control the units, you have to set DMX address from 1 to
512 so that the units can receive DMX signal.
Press the MENU button to enter menu mode, select the DMX Functions, press the ENTER button
to confirm, use the UP and DOWN button to select the DMX Address, press the ENTER button to
confirm, the present address will blink on the display, use the UP and DOWN button to adjust the
address from 0 to 512, press the ENTER button to store. Press the MENU button back to the last
menu or let the unit idle 7 seconds to exit menu mode.
Please refer to the following diagram to address your DMX512 channel for the first 4 units:
Channel mode
Unit 1
Address
Unit 2
Address
Unit 3
Address
Unit 4
Address
18 Channels 1 19 37 55
22 Channels 1 23 45 67
25 Channels 126 51 76
4.3 DMX 512 Configuration
18 Channels Mode (Mode 1):
Channel Value Function
1
000-255
Pan
Pan movement 0°-540°
2
000-255
Tilt
Tilt movement 0°-270°
3
000-019
020-024
025-064
065-069
Shutter
Blackout
Open
Strobe 1: fast slow
Open
14B

070-084
085-089
090-104
105-109
110-124
125-129
130-144
145-149
150-164
165-169
170-184
185-189
190-204
205-209
210-224
225-229
230-244
245-255
Strobe 2: opening pulse, fast slow
Open
Strobe 3: closing pulse, fast slow
Open
Strobe 4: random strobe, fast slow
Open
Strobe 5:random opening pulse, fast slow
Open
Strobe 6:random closing pulse, fast slow
Open
Strobe 7:burst pulse, fast slow
Open
Strobe 8:random burst pulse, fast slow
Open
Strobe 9:sine wave, fast slow
Open
Strobe 10:burst, fast slow
Open
4
000-255
Dimmer
0~100%
5
000-255
Cyan
0~100%
6
000-255
Magenta
0~100%
7
000-255
Yellow
0~100%
8
000-006
007-012
Color
Open
Color1
15B

013-018
019-025
026-031
032-037
038-044
045-050
051-056
057-063
064-127
128-190
191-192
193-255
Color2
Color3
Color4
Color5
Color6
Color7
Color8
Color9
Color Index
Fast->Slow
Stop
Slow->Fast
9
000-007
008-015
016-023
024-031
032-039
040-047
048-055
056-063
064-072
073-081
082-090
091-099
100-108
109-117
118-127
128-190
Gobo
Open
Gobo1
Gobo2
Gobo3
Gobo4
Gobo5
Gobo6
Gobo7
Gobo1 Shaking
Gobo2 Shaking
Gobo3 Shaking
Gobo4 Shaking
Gobo5 Shaking
Gobo6Shaking
Gobo7Shaking
Fast->Slow
16B

191-192
193-255
Stop
Slow->Fast
10
000-127
128-190
191-192
193-255
RGobo1
Index 0 -> 360
Fast->Slow
Stop
Slow->Fast
11
000-006
007-012
013-018
019-025
026-031
032-037
038-044
045-050
051-056
057-063
064-070
071-077
078-084
085-091
092-098
099-105
106-112
113-119
120-127
128-190
191-192
Gobo 2
Open
Gobo1
Gobo2
Gobo3
Gobo4
Gobo5
Gobo6
Gobo7
Gobo8
Gobo9
Gobo1 Shaking
Gobo2 Shaking
Gobo3 Shaking
Gobo4 Shaking
Gobo5 Shaking
Gobo6Shaking
Gobo7 Shaking
Gobo8Shaking
Gobo9Shaking
Fast->Slow
Stop
17B

193-255 Slow->Fast
12
000-255
Iris
Big->Small
13
000-010
011-127
128-255
Prism1
No Effect
Prism1 On
Prism1 Macro1 – Macro32
14
000-127
128-190
191-192
193-255
R-Prism1
Index 0 -> 360
Fast->Slow
Stop
Slow->Fast
15
000-255
Frost
0-100%
16
000-255
Zoom
17
000-255
Focus
0-100%
18
000-069
070-079
080-089
090-099
100-109
110-119
120-129
130-139
140-149
150-159
Function
Null
BlackOut Pan/Tilt Move Enable
BlackOut Pan/Tilt Move Disable
BlackOut Color Move Enable
BlackOut Color Move Disable
BlackOut Gobo Move Enable
BlackOut Gobo Move Disable
Focus Compensate Disable
Focus Compensate Near
Focus Compensate Medium
18B

160-169
170-199
200-209
210-219
220-229
230-255
Focus Compensate Far
Null
Reset All
Reset Effect
Reset Pan/Tilt
Null
22 Channels Mode (Mode 2):
Channel Value Function
1
000-255
Cyan
0-100%
2
000-255
Magenta
0-100%
3
000-255
Yellow
0-100%
4
000-006
007-012
013-018
019-025
026-031
032-037
038-044
045-050
051-056
057-063
064-127
128-190
191-192
193-255
Color
Open
Color1
Color2
Color3
Color4
Color5
Color6
Color7
Color8
Color9
Color Index
Fast->Slow
Stop
Slow->Fast
19B
Other manuals for ENERGY SPOT XA-400 SPOT
1
Table of contents
Other ACME Dj Equipment manuals

ACME
ACME IU-01 User manual

ACME
ACME MACE User manual

ACME
ACME Stage Panel 1080 User manual

ACME
ACME LED WAVE 100 User manual

ACME
ACME LED-256D RGB User manual

ACME
ACME LP-F2000 VW User manual

ACME
ACME GENESIS COLOR II User manual

ACME
ACME LED-BL4B User manual

ACME
ACME AE-610 BEAM User manual

ACME
ACME LED-BL8 User manual

ACME
ACME MP-90 RGBW User manual

ACME
ACME Ellipsoidal E-300 D2550 User manual

ACME
ACME ASTRO LED-256D User manual

ACME
ACME CYC-200 FC User manual

ACME
ACME CB-16FC User manual

ACME
ACME LED-245 II User manual

ACME
ACME MH-575S User manual

ACME
ACME Color Par 36 User manual

ACME
ACME MH-275R User manual

ACME
ACME iMove 50SR User manual