manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ADC
  6. •
  7. Thermometer
  8. •
  9. ADC Adtemp II 412 Maintenance manual

ADC Adtemp II 412 Maintenance manual

Other ADC Thermometer manuals

ADC Adtemp 422 Maintenance manual

ADC

ADC Adtemp 422 Maintenance manual

ADC Adtemp ULTRA 417 Maintenance manual

ADC

ADC Adtemp ULTRA 417 Maintenance manual

ADC Adtemp II 412 Maintenance manual

ADC

ADC Adtemp II 412 Maintenance manual

ADC Adtemp V 418 Maintenance manual

ADC

ADC Adtemp V 418 Maintenance manual

ADC Adtemp 427 TempleTouch User manual

ADC

ADC Adtemp 427 TempleTouch User manual

ADC ADTEMP 421 User manual

ADC

ADC ADTEMP 421 User manual

ADC Adtemp 423 User guide

ADC

ADC Adtemp 423 User guide

ADC Adtemp V 418N User manual

ADC

ADC Adtemp V 418N User manual

ADC Adimals 426 User manual

ADC

ADC Adimals 426 User manual

ADC Adtemp 429 User manual

ADC

ADC Adtemp 429 User manual

ADC Adtemp ULTRA 417 User manual

ADC

ADC Adtemp ULTRA 417 User manual

ADC Adtemp Mini 432 User manual

ADC

ADC Adtemp Mini 432 User manual

ADC Adtemp 415FL User manual

ADC

ADC Adtemp 415FL User manual

ADC Adtemp 424 Maintenance manual

ADC

ADC Adtemp 424 Maintenance manual

ADC Adtemp Temple Touch  427 User manual

ADC

ADC Adtemp Temple Touch 427 User manual

ADC Adimals 426 User manual

ADC

ADC Adimals 426 User manual

ADC Adtemp V 418 Maintenance manual

ADC

ADC Adtemp V 418 Maintenance manual

ADC Adtempt 419 User manual

ADC

ADC Adtempt 419 User manual

ADC Adimals 426 Manual

ADC

ADC Adimals 426 Manual

ADC Adtemp 433 User manual

ADC

ADC Adtemp 433 User manual

ADC Adtemp II 412 Maintenance manual

ADC

ADC Adtemp II 412 Maintenance manual

ADC Adtemp V 418N Maintenance manual

ADC

ADC Adtemp V 418N Maintenance manual

ADC Adtemp 422 Maintenance manual

ADC

ADC Adtemp 422 Maintenance manual

ADC Adtemp 412 User manual

ADC

ADC Adtemp 412 User manual

Popular Thermometer manuals by other brands

Benetech GM900 instruction manual

Benetech

Benetech GM900 instruction manual

Parton PTD-400 manual

Parton

Parton PTD-400 manual

GAME 15900 owner's manual

GAME

GAME 15900 owner's manual

scigiene FP-180 instruction manual

scigiene

scigiene FP-180 instruction manual

Ametek Land UNO U1 600/1600C-L user guide

Ametek Land

Ametek Land UNO U1 600/1600C-L user guide

Delton 981A instruction manual

Delton

Delton 981A instruction manual

Taylor 5286498 instruction manual

Taylor

Taylor 5286498 instruction manual

Baker MM2P instruction manual

Baker

Baker MM2P instruction manual

Chino IR-FA Series instructions

Chino

Chino IR-FA Series instructions

Vive DMD1010 user manual

Vive

Vive DMD1010 user manual

Tarmo 320281 manual

Tarmo

Tarmo 320281 manual

Citizen CTD 504 instruction manual

Citizen

Citizen CTD 504 instruction manual

TFA 14.1500 instruction manual

TFA

TFA 14.1500 instruction manual

Gotemp THB4002 user guide

Gotemp

Gotemp THB4002 user guide

GREISINGER G 1202 Quick reference guide

GREISINGER

GREISINGER G 1202 Quick reference guide

Amprobe TMD-53W user manual

Amprobe

Amprobe TMD-53W user manual

Trotec BP10 operating manual

Trotec

Trotec BP10 operating manual

Radiance instruments RT616 Series product manual

Radiance instruments

Radiance instruments RT616 Series product manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

AdtempTM II 412
Digital Fever Thermometer
USE, CARE &
MAINTENANCE
®
Intended Use:
A digital thermometer is a device used to measure the body temperature of a patient by means
of a transducer coupled with an electric signal amplification, conditioning, and display unit.
Safety Infor ation:
• High, prolonged fever requires medical attention especially for young children.
Please contact your physician.
• Do not allow children to take their temperatures unattended.
• Read the enclosed instructions carefully to ensure accurate temperature readings. Temperature
readings are affected by many factors including exercise, drinking hot or cold beverages prior to
taking a reading as well as technique.
• Do not allow children to walk or run during temperature taking. The rigid probe could present
a hazard. Oral, underarm, and rectal temperatures vary by approximately 1°F (0.5°C).
• Dispose of batteries in accordance with locally applicable regulations, not with domestic waste.
• CAUTION:
Do not take an axillary temperature through patient’s clothing. Direct probe cover to
skin contact is required.
• CAUTION:
Biting the probe tip while taking a temperature may result in damage to the probe.
• CAUTION:
Do not autoclave. Please note the cleaning procedures described in this manual
•
WARNING:
This product may contain a chemical known to the state of California to cause cancer,
birth defects, or other reproductive harm.
• WARNING: Keep battery out of children’s reach. Swallowing battery could be harmful.
Battery should not be recharged or placed into extreme heat as it may explode.
Specifications
Size 5”L x 3/4”W x 3/8”H (12.7cm L x 1.905cm W x .9525cm H)
Weight 0.49 oz (14 grams)
Display: LCD, Liquid Crystal Display
Battery: 1.5v(LR41)
Battery Li e: Estimated 1,500 uses
Measurement Time: Oral 60 Seconds / Rectal 40 Seconds / Axillary 90 Seconds
Measurement Range: 90.0°F to 109.9°F / 32.0°C to 43.9°C
Accuracy: 0.2°F / 0.1°C between 96.0°F to 107.0°F / 34.0°C to 42.0°C at
a room temperature o 64.4°F to 82.4°F / 18°C to 28°C
+/-0.5°F/0.3°C between 90.0°F to 96.0°F/32.0°C to 34°C and
107.0°F to 109.9°F/42.0°C to 43.9°C
Measurement Mode: Real measurement with peak-hold method
Auto Turn O : In approximately 8’40”+/-1 minutes
Memory Feature: Stores last temperature taken.
Operating Environment: 10 °C to 40 °C, humidity: 15 % to 95 % (noncondensing)
Storage Environment Temp: -25 °C to +60 °C, humidity: 15 % to 95 % (noncondensing)
WARRANTY: This Thermometer is guaranteed for a period of 24 months from date of pur-
chase. This warranty does not cover batteries, or damage resulting from improper handling or
use. Specific legal rights stipulated in your state may guide this warranty. If you have a legitimate
claim under this warranty, send item(s) postage paid to Service Center, Attn: Repair Dept.,
55 Commerce Dr., Hauppauge, NY 117 . Please include your name and address, phone
no., proof of purchase, and a brief note explaining the problem., your return address and
$2.00 to cover shipping and handling.
Visit www.adctoday.co to view this instruction booklet in other languages.
IB p/n 93-412-00 rev 3 Printed in China
Read the instructions care ully
be ore using this device.
Type BF applied part
Dist. by: ADC®
55 Commerce Drive,
Hauppauge, NY 11788
Inspected in the USA
Made in China
tel: 631-273-9600
toll ree: 1-800-232-2670
ax: 631-273-9659
www.adctoday.com
email: in o@adctoday.com
Onbo Electronic (Shenzhen) Co., Ltd.
No. 497, Ta Laneg Nan Road, Ta Laneg Street,
Baoan District, Shenzhen, China
Microli e AG, Espenstrasse
139, 9443 Widnau, Switzerland
0044
EC REP
93-412-00 rev 3 w/CE_ADTemp 93-412-00 rev 3 CE 10/17/14 10:35 AM Page 1
How to take te perature:
1. Place a probe cover carefully over the tip (Figure 1).
Select oral, underarm, or rectal as your measurement
site based on the individual requiring a temperature
measurement.
2. Push the Multi-Function button located at the end of the thermometer. The display
will read: “1 . ° ”. This is a function check indicating the unit is working properly.
The last measured temperature will be displayed for approximately 2-seconds. Next
the thermometer will read L°F.(or L°C).
3. The °F or °C symbol will flash when the unit is ready to measure temperature.
Please note that the “ ” indicates a low battery. Do not expect an accurate
temperature reading if this low battery indicator is present. An “ERR” message in the
window indicates your unit is not functioning properly.
4. Depending on the measurement site, the unit will complete measurement in 40
(rectal), 60 (oral), or approximately 90 (axillary) seconds. When the F° or C°
symbol stops flashing and the display reads a consistant temperature, the peak
temperature has been reached.
5. Read and record the temperature and time for reference. The reading will automatically
be stored in the memory.
6. Push the Multi-Function button to turn the unit off. This will prolong the battery life.
If you do not turn the unit off, it will shut off automatically in approximately ’40”+/-1
minutes.
Oral use: (for children 4 years and older)
1. Do not drink hot or cold fluids, exercise or perform other activities
that will raise or lower temperature readings when compared to
your normal, average temperature. The mouth should remain
closed up to 5 minutes before attempting a reading.
2. Place the probe tip well under the tongue as indicated (Figure 2).
3. Instruct children not to bite down on the probe.
4. The peak temperature should be reached in approximately
60 seconds, and a beep will sound. Opening the mouth or improper placement
of the probe tip could result in a longer time for a reading.
Rectal use:
1. Commonly used for babies, young children or when it is difficult to take an oral or
underarm temperature.
2. After placing the probe cover on the thermometer, lubricate with a water-soluble jelly
or petroleum jelly .
3. Gently insert the probe tip no more than 1/2 inch or 1.3 cm into the rectum. Do not
force the tip into the rectum if resistance is encountered.
4. Dispose of the used probe cover and wash the thermometer as recommended.
5. The peak temperature should be reached in approximately 40 seconds, and a beep
will sound.
Underar (Axillary) use:
1. Wipe underarm with a dry towel.
2. Place probe tip in armpit and bring arm down against the body.
3. The probe should be pointing upward in the same direction as your body if possible.
4. The time required for an accurate underarm temperature may be 90 seconds or
longer depending on placement of the probe and closure of the arm against the body.
Operation of the °F - °C feature (How to change the measuring scale) From the “OFF”
position, hold down the Multi-Function button for 5-sec. The thermometer will
automatically change from °F - °C or °C - °F. Release the button. You may toggle
between °C +°F. After 3-sec. in one scale the °C or °F will flash, indicating ready to
measure.
Standards:
Complies with EN 12470-3, ASTM E 1112-00, IEC 60601-1, IEC 60601-1- 2
Electromagnetic compatibility: device fulfills the stipulations of standard IEC 60601-1-2
The manufacturer recommends a calibration check every 2 years.
How to care for this product:
• Use of probe covers is recommended to help avoid spreading germs, and to keep
the thermometer clean. The thermometer should be cleaned after use even when
probe covers are used.
• Clean the thermometer tip and probe only using isopropyl alcohol or soap and water.
• Store the unit in the protective case while not in use.
• Do not store or keep in direct sunlight, or in high temperatures.
• Keep battery away from children.
• Do not open the thermometer.
• Do not drop the thermometer, as this may ruin the unit.
• The manufacturer recommends verifying the accuracy by an authorized laboratory
Figure 1
Figure 2
F
M
Probe Tip Display Window Multi-Function Button
Parts and Asse bly
93-412-00 rev 3 w/CE_ADTemp 93-412-00 rev 3 CE 10/17/14 10:35 AM Page 2