manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ADTRAN
  6. •
  7. Control Unit
  8. •
  9. ADTRAN Job Aid+ 1442981G8C User manual

ADTRAN Job Aid+ 1442981G8C User manual

Other ADTRAN Control Unit manuals

ADTRAN GPON D OLT User manual

ADTRAN

ADTRAN GPON D OLT User manual

ADTRAN Total Access 1500 FT1 DP Instruction Manual

ADTRAN

ADTRAN Total Access 1500 FT1 DP Instruction Manual

ADTRAN Job Aid+ 1442707G3 User manual

ADTRAN

ADTRAN Job Aid+ 1442707G3 User manual

ADTRAN SFP GPON ONU User manual

ADTRAN

ADTRAN SFP GPON ONU User manual

ADTRAN Total Access 300 Series Product manual

ADTRAN

ADTRAN Total Access 300 Series Product manual

ADTRAN Job Aid+ 1442804G1 User manual

ADTRAN

ADTRAN Job Aid+ 1442804G1 User manual

ADTRAN SFP User manual

ADTRAN

ADTRAN SFP User manual

ADTRAN Job Aid+ 1442910G2 User manual

ADTRAN

ADTRAN Job Aid+ 1442910G2 User manual

ADTRAN Job Aid+ Total Access 5000 1442910G1C User manual

ADTRAN

ADTRAN Job Aid+ Total Access 5000 1442910G1C User manual

ADTRAN ATLAS 800 Series Module QUAD E1 User manual

ADTRAN

ADTRAN ATLAS 800 Series Module QUAD E1 User manual

ADTRAN Octal E&M User manual

ADTRAN

ADTRAN Octal E&M User manual

ADTRAN Job Aid+ 1442940G1 User manual

ADTRAN

ADTRAN Job Aid+ 1442940G1 User manual

ADTRAN T200 H2TU-R User manual

ADTRAN

ADTRAN T200 H2TU-R User manual

ADTRAN SFP User manual

ADTRAN

ADTRAN SFP User manual

ADTRAN Octal User manual

ADTRAN

ADTRAN Octal User manual

ADTRAN IMUX-56 User manual

ADTRAN

ADTRAN IMUX-56 User manual

ADTRAN Job Aid+ 1442971GX User manual

ADTRAN

ADTRAN Job Aid+ 1442971GX User manual

ADTRAN Total Access 300 Series User manual

ADTRAN

ADTRAN Total Access 300 Series User manual

ADTRAN Quad E1/PRA User manual

ADTRAN

ADTRAN Quad E1/PRA User manual

ADTRAN NetVanta SHDSL User manual

ADTRAN

ADTRAN NetVanta SHDSL User manual

ADTRAN Octal BRI S/T User manual

ADTRAN

ADTRAN Octal BRI S/T User manual

ADTRAN Total Access Quad BNC Instruction Manual

ADTRAN

ADTRAN Total Access Quad BNC Instruction Manual

ADTRAN Total Access 351 Series User manual

ADTRAN

ADTRAN Total Access 351 Series User manual

ADTRAN Modem-16 Module User manual

ADTRAN

ADTRAN Modem-16 Module User manual

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

jobAid
DESCRIPTION
The10GigESmallForm‐FactorPluggableLongReachDWDM
ExtendedTemperatureXFP(LR‐2XFP)isafullyduplexserial
electric,serialopticdevicewithbothtransmitandreceive
functionscontainedinasinglemodulethatprovidesahigh
speedseriallinkat10Gb/s.TheLR‐2XFPoperatesonOptical
Channel28(1554.94nm).Installedintheappropriatehost
module,theLR‐2XFPprovidesa10Gigabitinterfacetothe
supportingsystem.
ThetransmitsideoftheLR‐2XFPconvertsserialNRZelectrical
dataatthe10Gb/slineratetoastandardcompliantoptical
signal.ThereceivesideconvertstheincomingDCbalanced
serialNRZopticaldataatthe10Gb/slinerateintoserial
electricaldata.
NOTE
Toensurecompatibility,refertothedocumentationprovided
withthehostmodule.
ThefollowingfeaturesaresupportedontheLR‐2XFP:
♦1554.94nmopticalsignalsforupto80kmreach
♦Lowpowerconsumption(<3.5Wmax)
♦Biterrorrate10^–12
CAUTION
!
Duetocompliancecertificationrequirements,useonlySFPs/
XFPssuppliedbyADTRANwiththehostmodule.ADTRAN
cannotcertifysystemintegritywithotherSFPs.
Small Form-Factor Pluggable
10 GigE LR-2 Channel 28 (1554.94 nm) DWDM
80 km Extended Temperature XFP
OPERATIONAL SPECIFICATIONS
♦TransmitWavelength:1554.94nm(Channel28)
♦ReceiveWavelength:1270to1600nm
♦DataRate:9.95Gb/sto11.35Gb/s
♦Opticaltransmitlevels:–1.0to+3.0dBm
♦Opticalreceivelevel:–22.0to–7.0dBm
♦MinimumSpanAttenuation:10dB
♦Opticaldistance:80kmmaximum
♦Opticalconnectors:LC
♦ExtendedEnvironmentalSupport:
◊Operationaltemperaturerange:–5°Cto+60°C
◊Storagetemperaturerange:–40°Cto+85°C
◊Relativehumidityto85%,noncondensing
INSTALLATION
ToinstalltheLR‐2XFPintoanappropriatemodule,completethe
followingsteps:
1. InspecttheLR‐2XFP.Ifdamaged,fileaclaimwiththecarrier
andthencontactADTRANCustomerSupport.
CAUTION
!
DonotremovetheprotectiveendcapfromtheXFPuntilthefiber
opticcableisreadytobeconnected.
2. InserttheLR‐2XFPintotheSFPcageonthemodule.Ensure
thatthemanufacturer’slabelontheSFPisfacingupwardfor
correctinstallation.
3. SlidetheLR‐2XFPallthewayintothereceptacleuntilthereis
anaudible“click”.
NOTE
ThelatchontheLR‐2XFPisusedtoremovetheXFPfromthecage
onthecircuitcard.
CLEI: BVL3AJTD_ _
Product P/N: 1442981G8C
Issue Date: May 2011
Document P/N: 61442981G8C-22B
Warranty: ADTRAN will replace or repair this product
within the warranty period if it does not meet its
published specifications or fails while in
service. Warranty information can be found
online at www.adtran.com/warranty.
ADTRAN CUSTOMER CARE:
From within the U.S. 1.800.726.8663
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807
*61442981G8C-22B*
SAFETY AND REGULATORY COMPLIANCE
CAUTION
!
ElectrostaticDischarge(ESD)candamageelectronicmodules.
Whenhandlingmodules,wearanantistaticdischargewriststrap
topreventdamagetoelectroniccomponents.Placemodulesin
antistaticpackingmaterialwhentransportingorstoring.When
workingonmodules,alwaysplacethemonanapproved
antistaticmatthatiselectricallygrounded.
TheLR‐2XFPmeetsorexceedsalltheapplicablerequirementsof
NEBS,TelcordiaGR‐63‐CORE,GR‐1089‐CORE,andETSIEN
300368.TheLR‐2XFPisintendedfordeploymentinCentral
Officetypefacilities,EEEs,EECs,andlocationswheretheNEC
applies(forexample,CustomerPremises).
TheLR‐2XFPistobeinstalledinADTRANproductsin
RestrictedAccessLocationsonly,andinstalledbytrainedservice
personnel.
ThisdevicecomplieswithPart15oftheFCCrules.Operationis
subjecttothefollowingtwoconditions:
1. Thisdevicemaynotcauseharmfulinterference
2. Thisdevicemustacceptanyinterferencereceived,including
interferencethatmaycauseundesiredoperation.
ChangesormodificationsnotexpresslyapprovedbyADTRAN
couldvoidtheuserʹsauthoritytooperatethisequipment.
CAUTION
!
♦ PerGR‐1089‐COREtheADTRANsystemthattheLR‐2XFPis
beingdeployedinisdesignedandintendedforinstallationas
partofaCommonBondingNetwork(CBN).TheADTRAN
systemthattheLR‐2XFPisbeingdeployedinisnotdesigned
norintendedforinstallationaspartofanIsolatedBonding
Network(IBN).
♦ PerGR‐1089‐CORESection9,theLR‐2XFPdoesnothavean
internalDCconnectionbetweenbatteryreturnandframe
ground.TheLR‐2XFPcanbeinstalledinaDC‐I(isolated)or
DC‐C(common)installation.Forinstallationswhereother
cardsorthehostsystemhaveinternalconnectionsbetween
batteryreturnandframeground,thesystemwouldbe
intendedfordeploymentonlyinaDC‐Cinstallation.
♦ TheADTRANsystemchassisframegroundterminalmustbe
connectedtoareliableearthgroundtoensurethatthemetal
enclosureoftheLR‐2XFPisproperlygroundedthroughthe
backplaneconnector.
♦ The10GigELR‐2Channel28(1554.94nm)DWDM80km
ExtendedTemperatureXFPisaClass1LaserProductand
complieswiththeLaserSafetyrequirementsofFDA21CFR
1040.11,EN60825‐1,andEN60825‐2.TheLR‐2XFPisNRTL
ListedandCBCertifiedtoallapplicableAmericanand
Europeansafetystandards.
NOTE
♦ TheGigabitEthernetport(s)areopticalandthereforearenot
classifiedasanytypeofportasdefinedinAppendixBofGR‐
1089‐COREIssue5.
♦ ThisLR‐2XFPiscompliantwithSFF‐8472“DigitalDiagnostics
MonitoringInterfaceforOpticalTransceivers,”Revision9.3
♦ ThisLR‐2XFPiscompliantwiththeXFPMulti‐Source
Agreement(MSA).
♦ ThisLR‐2XFPisdesignedtobedeployedinGR‐3108‐CORE
environmentalclass1or2asdefinedinGR‐3108‐COREIssue
2.
TheLR‐2XFPisdesignedtomeetthefollowingenvironmental
classes:
♦ETSIEN300019‐1‐1“Classificationofenvironmental
conditions;Storage,”Class1.2
♦ETSIEN300019‐1‐2“Classificationofenvironmental
conditions;Transportation,”Class2.3
♦ETSIEN300019‐1‐3“Classificationofenvironmental
conditions;Stationaryuseatweather‐protectedlocations,”
Class3.3
Theequipmentisdesignedtofunctionwithoutdegradation
duringexposuretoalltestseveritiesperClass3.3.
The10GigELR‐2Channel28(1554.94nm)DWDM80km
ExtendedTemperatureXFPmeetsEURoHSDirective2002/95/EC
and/orapplicableexemptions.Refertowww.adtran.comfor
furtherinformationonRoHS/WEEE.
C A U T I O NC A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.