jobAid
DESCRIPTION
The10GigESmallForm‐FactorPluggableLongReachDWDM
ExtendedTemperatureXFP(LR‐2XFP)isafullyduplexserial
electric,serialopticdevicewithbothtransmitandreceive
functionscontainedinasinglemodulethatprovidesahigh
speedseriallinkat10Gb/s.TheLR‐2XFPoperatesonOptical
Channel28(1554.94nm).Installedintheappropriatehost
module,theLR‐2XFPprovidesa10Gigabitinterfacetothe
supportingsystem.
ThetransmitsideoftheLR‐2XFPconvertsserialNRZelectrical
dataatthe10Gb/slineratetoastandardcompliantoptical
signal.ThereceivesideconvertstheincomingDCbalanced
serialNRZopticaldataatthe10Gb/slinerateintoserial
electricaldata.
NOTE
Toensurecompatibility,refertothedocumentationprovided
withthehostmodule.
ThefollowingfeaturesaresupportedontheLR‐2XFP:
♦1554.94nmopticalsignalsforupto80kmreach
♦Lowpowerconsumption(<3.5Wmax)
♦Biterrorrate10^–12
CAUTION
!
Duetocompliancecertificationrequirements,useonlySFPs/
XFPssuppliedbyADTRANwiththehostmodule.ADTRAN
cannotcertifysystemintegritywithotherSFPs.
Small Form-Factor Pluggable
10 GigE LR-2 Channel 28 (1554.94 nm) DWDM
80 km Extended Temperature XFP
OPERATIONAL SPECIFICATIONS
♦TransmitWavelength:1554.94nm(Channel28)
♦ReceiveWavelength:1270to1600nm
♦DataRate:9.95Gb/sto11.35Gb/s
♦Opticaltransmitlevels:–1.0to+3.0dBm
♦Opticalreceivelevel:–22.0to–7.0dBm
♦MinimumSpanAttenuation:10dB
♦Opticaldistance:80kmmaximum
♦Opticalconnectors:LC
♦ExtendedEnvironmentalSupport:
◊Operationaltemperaturerange:–5°Cto+60°C
◊Storagetemperaturerange:–40°Cto+85°C
◊Relativehumidityto85%,noncondensing
INSTALLATION
ToinstalltheLR‐2XFPintoanappropriatemodule,completethe
followingsteps:
1. InspecttheLR‐2XFP.Ifdamaged,fileaclaimwiththecarrier
andthencontactADTRANCustomerSupport.
CAUTION
!
DonotremovetheprotectiveendcapfromtheXFPuntilthefiber
opticcableisreadytobeconnected.
2. InserttheLR‐2XFPintotheSFPcageonthemodule.Ensure
thatthemanufacturer’slabelontheSFPisfacingupwardfor
correctinstallation.
3. SlidetheLR‐2XFPallthewayintothereceptacleuntilthereis
anaudible“click”.
NOTE
ThelatchontheLR‐2XFPisusedtoremovetheXFPfromthecage
onthecircuitcard.
CLEI: BVL3AJTD_ _
Product P/N: 1442981G8C
Issue Date: May 2011
Document P/N: 61442981G8C-22B
Warranty: ADTRAN will replace or repair this product
within the warranty period if it does not meet its
published specifications or fails while in
service. Warranty information can be found
online at www.adtran.com/warranty.
ADTRAN CUSTOMER CARE:
From within the U.S. 1.800.726.8663
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807
*61442981G8C-22B*
SAFETY AND REGULATORY COMPLIANCE
CAUTION
!
ElectrostaticDischarge(ESD)candamageelectronicmodules.
Whenhandlingmodules,wearanantistaticdischargewriststrap
topreventdamagetoelectroniccomponents.Placemodulesin
antistaticpackingmaterialwhentransportingorstoring.When
workingonmodules,alwaysplacethemonanapproved
antistaticmatthatiselectricallygrounded.
TheLR‐2XFPmeetsorexceedsalltheapplicablerequirementsof
NEBS,TelcordiaGR‐63‐CORE,GR‐1089‐CORE,andETSIEN
300368.TheLR‐2XFPisintendedfordeploymentinCentral
Officetypefacilities,EEEs,EECs,andlocationswheretheNEC
applies(forexample,CustomerPremises).
TheLR‐2XFPistobeinstalledinADTRANproductsin
RestrictedAccessLocationsonly,andinstalledbytrainedservice
personnel.
ThisdevicecomplieswithPart15oftheFCCrules.Operationis
subjecttothefollowingtwoconditions:
1. Thisdevicemaynotcauseharmfulinterference
2. Thisdevicemustacceptanyinterferencereceived,including
interferencethatmaycauseundesiredoperation.
ChangesormodificationsnotexpresslyapprovedbyADTRAN
couldvoidtheuserʹsauthoritytooperatethisequipment.
CAUTION
!
♦ PerGR‐1089‐COREtheADTRANsystemthattheLR‐2XFPis
beingdeployedinisdesignedandintendedforinstallationas
partofaCommonBondingNetwork(CBN).TheADTRAN
systemthattheLR‐2XFPisbeingdeployedinisnotdesigned
norintendedforinstallationaspartofanIsolatedBonding
Network(IBN).
♦ PerGR‐1089‐CORESection9,theLR‐2XFPdoesnothavean
internalDCconnectionbetweenbatteryreturnandframe
ground.TheLR‐2XFPcanbeinstalledinaDC‐I(isolated)or
DC‐C(common)installation.Forinstallationswhereother
cardsorthehostsystemhaveinternalconnectionsbetween
batteryreturnandframeground,thesystemwouldbe
intendedfordeploymentonlyinaDC‐Cinstallation.
♦ TheADTRANsystemchassisframegroundterminalmustbe
connectedtoareliableearthgroundtoensurethatthemetal
enclosureoftheLR‐2XFPisproperlygroundedthroughthe
backplaneconnector.
♦ The10GigELR‐2Channel28(1554.94nm)DWDM80km
ExtendedTemperatureXFPisaClass1LaserProductand
complieswiththeLaserSafetyrequirementsofFDA21CFR
1040.11,EN60825‐1,andEN60825‐2.TheLR‐2XFPisNRTL
ListedandCBCertifiedtoallapplicableAmericanand
Europeansafetystandards.
NOTE
♦ TheGigabitEthernetport(s)areopticalandthereforearenot
classifiedasanytypeofportasdefinedinAppendixBofGR‐
1089‐COREIssue5.
♦ ThisLR‐2XFPiscompliantwithSFF‐8472“DigitalDiagnostics
MonitoringInterfaceforOpticalTransceivers,”Revision9.3
♦ ThisLR‐2XFPiscompliantwiththeXFPMulti‐Source
Agreement(MSA).
♦ ThisLR‐2XFPisdesignedtobedeployedinGR‐3108‐CORE
environmentalclass1or2asdefinedinGR‐3108‐COREIssue
2.
TheLR‐2XFPisdesignedtomeetthefollowingenvironmental
classes:
♦ETSIEN300019‐1‐1“Classificationofenvironmental
conditions;Storage,”Class1.2
♦ETSIEN300019‐1‐2“Classificationofenvironmental
conditions;Transportation,”Class2.3
♦ETSIEN300019‐1‐3“Classificationofenvironmental
conditions;Stationaryuseatweather‐protectedlocations,”
Class3.3
Theequipmentisdesignedtofunctionwithoutdegradation
duringexposuretoalltestseveritiesperClass3.3.
The10GigELR‐2Channel28(1554.94nm)DWDM80km
ExtendedTemperatureXFPmeetsEURoHSDirective2002/95/EC
and/orapplicableexemptions.Refertowww.adtran.comfor
furtherinformationonRoHS/WEEE.
C A U T I O NC A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.

Other ADTRAN Control Unit manuals

ADTRAN Total Access Quad BNC Instruction Manual

ADTRAN

ADTRAN Total Access Quad BNC Instruction Manual

ADTRAN Job Aid+ Total Access 5000 1442910G1C User manual

ADTRAN

ADTRAN Job Aid+ Total Access 5000 1442910G1C User manual

ADTRAN Job Aid+ 1442707G3 User manual

ADTRAN

ADTRAN Job Aid+ 1442707G3 User manual

ADTRAN Total Access 1500 Instruction Manual

ADTRAN

ADTRAN Total Access 1500 Instruction Manual

ADTRAN T400 Maintenance and service guide

ADTRAN

ADTRAN T400 Maintenance and service guide

ADTRAN 1200065L1-1 User manual

ADTRAN

ADTRAN 1200065L1-1 User manual

ADTRAN Octal BRI S/T User manual

ADTRAN

ADTRAN Octal BRI S/T User manual

ADTRAN Job Aid+ 1442704PG2 User manual

ADTRAN

ADTRAN Job Aid+ 1442704PG2 User manual

ADTRAN Octal User manual

ADTRAN

ADTRAN Octal User manual

ADTRAN 1442442F1 User manual

ADTRAN

ADTRAN 1442442F1 User manual

ADTRAN IMUX-56 User manual

ADTRAN

ADTRAN IMUX-56 User manual

ADTRAN Job Aid+ 1442982G7C User manual

ADTRAN

ADTRAN Job Aid+ 1442982G7C User manual

ADTRAN SFP User manual

ADTRAN

ADTRAN SFP User manual

ADTRAN 1200261L1 User manual

ADTRAN

ADTRAN 1200261L1 User manual

ADTRAN SFP User manual

ADTRAN

ADTRAN SFP User manual

ADTRAN GPON D OLT User manual

ADTRAN

ADTRAN GPON D OLT User manual

ADTRAN T200 H2TU-R User manual

ADTRAN

ADTRAN T200 H2TU-R User manual

ADTRAN Job Aid+ 1442910G2 User manual

ADTRAN

ADTRAN Job Aid+ 1442910G2 User manual

ADTRAN U-BR1TE Instruction Manual

ADTRAN

ADTRAN U-BR1TE Instruction Manual

ADTRAN TRACER QUAD E1 User manual

ADTRAN

ADTRAN TRACER QUAD E1 User manual

ADTRAN 1200222L1 User manual

ADTRAN

ADTRAN 1200222L1 User manual

ADTRAN T3 User manual

ADTRAN

ADTRAN T3 User manual

ADTRAN Total Access 351 Series User manual

ADTRAN

ADTRAN Total Access 351 Series User manual

ADTRAN 1200315L1 User manual

ADTRAN

ADTRAN 1200315L1 User manual

Popular Control Unit manuals by other brands

BASF EXACTUS IFX-21 user guide

BASF

BASF EXACTUS IFX-21 user guide

Smartgen CMM365A-2G user manual

Smartgen

Smartgen CMM365A-2G user manual

Fleck 9500 Service manual

Fleck

Fleck 9500 Service manual

SABAF 10 Instructions for use, maintenance instructions

SABAF

SABAF 10 Instructions for use, maintenance instructions

Danfoss AMZ 112 installation guide

Danfoss

Danfoss AMZ 112 installation guide

Burkert 265X instruction manual

Burkert

Burkert 265X instruction manual

ABB NMBA-01 Installation and startup guide

ABB

ABB NMBA-01 Installation and startup guide

Siemens OZW771 installation instructions

Siemens

Siemens OZW771 installation instructions

Quectel EC2 Series Design Guideline

Quectel

Quectel EC2 Series Design Guideline

Keysight Technologies M8000 Series installation guide

Keysight Technologies

Keysight Technologies M8000 Series installation guide

XIA Pixie-32 user manual

XIA

XIA Pixie-32 user manual

Lumel MR03 Series user manual

Lumel

Lumel MR03 Series user manual

Neles Jamesbury Series Installation maintenance and operating instructions

Neles

Neles Jamesbury Series Installation maintenance and operating instructions

SKYDANCE LP-150M-12 user manual

SKYDANCE

SKYDANCE LP-150M-12 user manual

Robertshaw Uni-Kit 720-079 Installation data

Robertshaw

Robertshaw Uni-Kit 720-079 Installation data

Quectel LTE-A Series Hardware design

Quectel

Quectel LTE-A Series Hardware design

Ebyte E108-GN Series user manual

Ebyte

Ebyte E108-GN Series user manual

Geco G-403-P02 user manual

Geco

Geco G-403-P02 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.