AMQ ACTIV-Pro3 User manual

ACTIV-Pro3 assembly guide

SAFETY STATEMENT .................... 3-5
90°.....................................6
Components.............................7
Leg Attachment ..........................8
Attaching Stretcher Bar ....................9
Attaching Cantilevers & Feet ...............11
Adjusting Stretcher Bars ..................12
Connecting Power .......................13
Connecting Worksurface ..................14
Program Height Memory Presets............15
120°...................................16
Components............................17
Leg Attachment .........................18
Attaching Stretcher Bar ...................19
Attaching Cantilevers & Feet ...............21
Adjusting Stretcher Bars ..................22
Connecting Worksurface and Power .........23
Program Height Memory Presets............24

ACTIV-PRO3 ASSEMBLY GUIDE | 3 amqsolutions.com
SAFETY STATEMENT
WARNING RISK OF SERIOUS INJURY DUE TO PINCH POINTS, TIPOVER, OR
POTENTIAL COLLAPSE.
This powered, adjustable height desk appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have
been given supervision or instruction concerning use of the appliance by a person responsible for their
safety. Children should be supervised to ensure that they do not play with the appliance.
• RISK OF DEATH OR SERIOUS
INJURY. Raising or lowering desk
can trap, pinch or crush body parts or
property.
• CRUSH HAZARD - DO NOT PLACE
FEET, LEGS OR OTHER BODY
PARTS ON OBJECTS PLACED
UNDER TABLE TOP OR BELOW
MODESTY PANEL.
• DO NOT OPERATE THIS EQUIPMENT
Unless Properly Trained.
• DO NOT ALLOW USE BY CHILDREN
or people unable to understand the
risks and to safely adjust the desk
height. Lock handset or remove and
secure power cord when not in use to
prevent children from adjusting the desk
unsupervised.
• INSPECT REGULARLY. Stop using if
product is damaged or has loose parts.
Only repair with AMQ authorized parts
and methods.
• MAINTAIN >1” (25mm) GAP ABOVE
OBJECTS ON DESK AT MAX HEIGHT AND BETWEEN THE DESK & ADJACENT OBJECTS. Locate desk,
accessories, and nearby objects to allow movement of desktop through full range without pulling cords, trapping
body parts, or colliding with anything (shelves, electrical plugs and cords, door knobs, window sills, storage
cabinets, etc.)
• Always lock castors during use to keep adequate clearance between desk and other objects.
Risk of Tip-Over Injury. Before moving on castors:
1. Adjust desk to lowest height.
2. Verify path is clear of obstructions.
3. Remove objects not attached to desk.
4. Restrict monitor arms from moving outside desk perimeter.
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired
operation.
This equipment has been tested and found to comply with the limits for a class B digital device pursuant to Part 15 for FCC rules. These
limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving
antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet or a circuit different from
that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.
Important: Changes or modifications to this product not authorized by AMQ could void your authority to operate the product.
Max.
Min.
>1"
(25mm)
>1"
(25mm)
>1"
(25mm)
X
X
X
NOTE: Desk image
is for reference only.
Table shape and leg
quantity may change
based on the style
and configuration.
(877) 801-0307
www.amqsolutions.com
?

ACTIV-PRO3 ASSEMBLY GUIDE | 4 amqsolutions.com
WARNING
SAFETY STATEMENT
RISK OF SERIOUS INJURY:
POTENTIAL FOR INJURY: The use of worksurfaces that do not comply with the AMQ defined criteria and limitations
could cause personal injury or property damage due to pinch points, instability, or other problems.
POTENTIAL FOR NON-COMPLIANCE: The use of work surfaces that do not comply with AMQ criteria VOIDS any
AMQ claims of compliance with ANSI/BIFMA, UL, LEED, or other applicable requirements. The use of non-AMQ work
surfaces on AMQ adjustable-height bases may NOT be accepted as compliant to municipal electrical codes or OSHA
federal workplace standards, because this use does not create an NRTL (UL, ETL, etc.) listed product. AMQ is not
responsible for the ultimate determinations of compliance for height-adjustable bases with non-AMQ work surfaces.AMO
assumes NO liability for lack of standards compliance in these instances.
WARRANTY RESTRICTIONS: The use of non-AMQ supplied work surfaces VOIDS all AMQ warranties, expressed or
implied.
DISCLAIMER: The use of non-AMQ work surfaces is NOT recommended. Any use of a non-AMQ work surface
requires additional investigation by the customer regarding the appropriateness for use. It is the sole responsibility of
the customer to determine the suitability and safety of the selected work surface construction and attachment means.
The following information is provided as a guideline, but does not address all potential issues. Customers should seek
professional guidance as to the appropriateness of their chosen work surface.
MANDATORY REQUIREMENTS REGARDLESS OF WORK SURFACE MATERIAL OR CONSTRUCTION:
FASTENERS: Adjustable-height bases include fasteners intended for use with AMQ work surfaces.
These fasteners may potentially also be suitable for work surfaces meeting the following criteria:
• Medium-density or higher particleboard or fiberboard cores with High-pressure laminate (HPL), Lowpressure
laminate (LPL) or veneer & backers
• Thickness of .984” (25.0 mm) or greater
• Fasteners located a minimum distance of .984” (25.0 mm) from any edge
Any other work surface construction will require different and/or additional fastening means and these means must be
determined by the project’s designer, architect, or engineer. For example, solid-surface materials should use appropriate
threaded inserts and corresponding fasteners or
similar attachment means.
In all cases, all fastener locations provided in the
base attachment features MUST be used (e.g. if
attachment plate has 6 screw holes, all 6 holes
must be used for attachment).
FLAMMABILITY: Any worksurface or similar large
part> 10ft” 2 must have a flame spread< 200
and a smoke developed index < 450 when tested
per UL 723.
SHARP EDGES: All accessible edges of the
work surface must meet 1439 test for sharp
edges.
DIMENSIONAL LIMITATIONS:
• Work surface depth not to exceed
30”(762mm)
• Longitudinal work surface position on base
must be on centerline
• Maximum work surface width may not
exceed 72” (1828.8 mm)
• Work surface overhang (distance from side
of support cantilever to edge of work surface)
must be greater than .75” (19mm) and may not exceed 1.25” (32 mm)
FOLLOW ALL WARNINGS PROVIDED FOR BASE+ WORK SURFACE.
WORKSURFACE
OVERHANG
C
L
+
WORKSURFACE
WIDTH
WORKSURFACE
DEPTH

ACTIV-PRO3 ASSEMBLY GUIDE | 5 amqsolutions.com
SAFETY INSTRUCTIONS
When using an electrical furnishing, basic precautions should always be followed, including the following:
Read all instructions before using (this furnishing). PLEASE SAVE THESE INSTRUCTIONS, AND THE USER
GUIDE, IN AN OBVIOUS PLACE FOR THE END USER AFTER ASSEMBLY.
To reduce the risk of burns, fire, electric shock or injury to persons:
1. Always unplug this furnishing from the electrical outlet before cleaning.
2. Use this table only for its intended use as described in these instructions. Do not use attachments not
recommended by the manufacturer.
3. Never operate this table if it has a damaged cord or plug, if it is not working properly, or if it has been
dropped or damaged.
4. Keep the cord away from heated surfaces.
5. Never drop or insert any object into any opening.
6. Do not use outdoors.
7. Do not operate where aerosol (spray) products are being used or where
oxygen is being administered.
8. For loading always put heavier items at the bottom and not near the top in
order to help prevent the possibility of the furnishing tipping over.
9. Do not sit/stand on product.
10. Inspect regularly, stop using if damaged or loose parts found.
The desk or table shall be installed near power socket & the plug shall be
easily accessible.
WARNING - Risk of fire and shock
POLARIZED PLUG INSTRUCTIONS (Only for products with polarized plug)
To reduce the risk of electrical shock, some furnishings have a polarized plug (one
blade is wider than the other) like the plug illustrated in Figure 1. This plug will fit in
a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the
plug. If it still does not fit, contact a qualified electrician to install the proper outlet.
Do not change the plug in any way.
INSTRUCTIONS FOR DOUBLE INSULATED PRODUCTS: No grounding
means is provided on a double-insulated product. Nor is a means for grounding
to be added to the product. The plug looks like the plug illustrated in Figure 1. A
double insulated product is marked with the words “double insulation”, “double
insulated.”
GROUNDING INSTRUCTIONS (for grounded products only) - Some
products must be grounded. Connect these types of appliances to a properly
grounded outlet in accordance with all local codes and ordinances.
For products sold in North America and other 120V regions: the product is for use
on a nominal 120-V circuit. These products use a grounded plug that looks like the
plug illustrated in sketch A in Figure 2. Make sure that the product is connected to an outlet having the same
configuration as the plug. No adapter should be used with this product. WARNING - Risk of fire and shock,
Use only type SJT 18 AWG cord.
PLUG ILLUSTRATION DISCLAIMER - Illustrations shown here may not match your product.
Depending on your region, the plug pin size and shape may change.
OPERATING INSTRUCTIONS
Please refer to the User Guide, which is available online.
WARNING
GROUNDED
OUTLET
GROUNDED
OUTLET BOX
GROUNDING PIN
Figure 1
Polarized Plug
Figure 2
Grounding methods
Products with Grounded Plugs
Products with Polarized Plugs

ACTIV-PRO3 90°

ACTIV-PRO3 ASSEMBLY GUIDE | 7 amqsolutions.com
COMPONENTS
Hardware
foot
x 2
cantilever
x 2
center leg
bracket x 1
end leg
x 2
center leg
x 1
M10
x 8
M6
(special)
x 8
wood
screw
x 23
M6
x 12
handset
screw
x 2
cable clips
x 12
8mm 5mm
allen keys
4mm
screw caps
x 8
stretcher bar
end x 2
stretcher bar
x 4
frame
BL x 1
frame
BR x 1
frame
FL x 1
frame
FR x 1
controller
cable
x 2
power
cable
handset x 1
power box
x 1
90°
mending
plate x 2

ACTIV-PRO3 ASSEMBLY GUIDE | 8 amqsolutions.com
PHASE 1 | Leg Attachment
Step 1
Identify center leg.
Step 2
Assemble center leg to center bracket with M6
screws.
21
Front Right, Back
Right, Front Left
and Back Left are
indicated on Center
Bracket with the
initials FR, BR, FL
and BL
90°

ACTIV-PRO3 ASSEMBLY GUIDE | 9 amqsolutions.com
PHASE 2 | Attaching Stretcher Bar
1
BL BR
FL FR
Step 1
Match up frames to center bracket, lining up the holes
to the degree that you are setting (90° or 120°). Screw
in with M6 screws.
1
Note limit of stretch length and assemble base within that limitation.
maximum mounting distance
90°

ACTIV-PRO3 ASSEMBLY GUIDE | 10 amqsolutions.com
PHASE 2 | Attaching Stretcher Bar
Step 2
Assemble stretcher bars into the frames.
Step 3
Complete connecting the stretcher bars and
stretcher bar ends. Assemble end legs to the
stretcher bar ends using M6 (special) screws.
NOTE: Trim caps will be attached in Phase 4.
2
3
*For 48” width worksurfaces, do not install stretcher bars.
90°

ACTIV-PRO3 ASSEMBLY GUIDE | 11 amqsolutions.com
PHASE 3 | Attaching Cantilevers & Feet
Step 1
Plug cantilevers into the stretcher bar ends, lining
up holes. Add screws M6 (special). Tighten using
#4 allen key (or a long extension angle-tipped allen
key to expedite the process).
2
2
1
Step 2
Attach feet to legs with M10 screws.
NOTE: Trim caps will be attached in Phase 4.
90°

ACTIV-PRO3 ASSEMBLY GUIDE | 12 amqsolutions.com
PHASE 4 | Adjusting Stretcher Bars
Step 1
Adjust stretcher bar to desired length.
NOTE: The worksurface should be center aligned
with the cantilever depth and should have equal
amount of overhang on each end.
Step 2
Place caps.
90°
Make sure the screw bracket stays
in the center of the stretcher bars
1” 1”
2
11

ACTIV-PRO3 ASSEMBLY GUIDE | 13 amqsolutions.com
PHASE 5 | Connecting Power
Step 1
Attach cable management clips if using.
Step 2
Plug in electrical according to the diagram below.
90°
Facing
Direction
Connect each plugs according to
the drawing. Orientate yourself to
the table assembly by facing as
user to identify left and right motor.
Position handset wire into
dedicated slot before screwing
down base to worksurface.
Right Motor
Left
Motor
Power
Position wire into dedicated slots
to keep them neat & tidy before
screwing down base to worksurface.
1

ACTIV-PRO3 ASSEMBLY GUIDE | 14 amqsolutions.com
PHASE 6 | Connecting Worksurface
Step 1
Ensure that the base is properly positioned on the
worksurface. Attach base to the worksurface using
wood screws.
Step 2
Attach the handset to desired location using
handset screws (count x2).
Step 3
Tighten 4 factory inset screws to hold
desired length in place.
Step 4
Attach Mending Plates (Applicable to
ACTIV-Pro3 90° using 2 piece worksurface
setup) to the worksurface using wood
screws.
NOTE: 1 piece worksurface setup does not
need mending plates.
90°
43
2
1

ACTIV-PRO3 ASSEMBLY GUIDE | 15 amqsolutions.com
PHASE 7 | Program Height Memory Presets
Step 1
To Program Up to 4 Presets: Use the up/down
arrows to find desired height, then press “M”
followed by the number 1, 2, 3 or 4.
Step 2
To Test Programmed Height: Use the up/down
arrows to adjust the table to a height other than the
preset height. Then push and hold the number you
programmed to see if it automatically adjusts to
the height programmed in Step 1. You may need to
hold for 2-3 seconds to activate the base.
NOTE: If it does not adjust to the programmed
height, repeat Step 1 followed by Step 2.
A
M
Q
1
2
3
M
4

ACTIV-PRO3 120°

ACTIV-PRO3 ASSEMBLY GUIDE | 17 amqsolutions.com
COMPONENTS
Hardware
foot
x 2
cantilever
x 2
center leg
bracket x 1
end leg
x 2
center leg
x 1
M10
x 8
M6
(special)
x 8
wood
screw
x 23
M6
x 12
handset
screw
x 2
cable clips
x 12
8mm 5mm
allen keys
4mm
screw caps
x 8
stretcher bar
end x 2
stretcher bar
x 4
frame
BL x 1
frame
BR x 1
frame
FL x 1
frame
FR x 1
controller
cable
x 2
power
cable
handset x 1
power box
x 1
120°

ACTIV-PRO3 ASSEMBLY GUIDE | 18 amqsolutions.com
PHASE 1 | Leg Attachment
Step 1
Identify center leg.
Step 2
Assemble center leg to center bracket with M6
screws.
21
Front Right, Back
Right, Front Left
and Back Left are
indicated on Center
Bracket with the
initials FR, BR, FL
and BL
120°

ACTIV-PRO3 ASSEMBLY GUIDE | 19 amqsolutions.com
PHASE 2 | Attaching Stretcher Bar
1
BL BR
FL FR
Step 1
Match up frames to center bracket, lining up the holes
to the degree that you are setting (90° or 120°). Screw
in with M6 screws.
1
Note limit of stretch length and assemble base within that limitation.
maximum mounting distance
120°

ACTIV-PRO3 ASSEMBLY GUIDE | 20 amqsolutions.com
PHASE 2 | Attaching Stretcher Bar
Step 2
Assemble stretcher bars into the frames.
Step 3
Complete connecting the stretcher bars and
stretcher bar ends. Assemble end legs to the
stretcher bar ends using M6 (special) screws.
NOTE: Trim caps will be attached in Phase 4.
2
3
*For 48” width worksurfaces, do not install stretcher bars.
120°
Other manuals for ACTIV-Pro3
2
Table of contents
Other AMQ Indoor Furnishing manuals
Popular Indoor Furnishing manuals by other brands

Vivo
Vivo DESK-AC03L-B instruction manual

anko
anko SLR-23222 instruction manual

Costway
Costway NP10278 user manual

Forte
Forte HEYS821 Assembling Instruction

Lefroy Brooks
Lefroy Brooks M1-5301 Installation, operating, & maintenance instructions

RSI Systems Furniture
RSI Systems Furniture EZcube installation guide

HON
HON HBXRISER installation guide

CUGGL
CUGGL FSC WOODEN GATE NATURAL Care & instruction manual

Axor
Axor Massaud 18013001 installation instructions

Southern Enterprises
Southern Enterprises Kinsley BT7860A0TX Assembly instructions

Amart Furniture
Amart Furniture Insurgent 75373 Assembly instruction

Argos
Argos 875/9047 Assembly instructions