EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Arjo
  6. •
  7. Medical Equipment
  8. •
  9. Arjo Auralis User manual

Arjo Auralis User manual

Other manuals for Auralis

5

Other Arjo Medical Equipment manuals

Arjo Auralis User manual

Arjo

Arjo Auralis User manual

Arjo AtmosAir Velaris User manual

Arjo

Arjo AtmosAir Velaris User manual

Arjo AtmosAir User manual

Arjo

Arjo AtmosAir User manual

Arjo TheraKair Visio User manual

Arjo

Arjo TheraKair Visio User manual

Arjo MAA2070M User manual

Arjo

Arjo MAA2070M User manual

Arjo Nimbus Professional User manual

Arjo

Arjo Nimbus Professional User manual

Arjo TheraRest User manual

Arjo

Arjo TheraRest User manual

Arjo Maxi Sky 2 PLUS User manual

Arjo

Arjo Maxi Sky 2 PLUS User manual

Arjo Simulflex User manual

Arjo

Arjo Simulflex User manual

Arjo Stretcher Slings User manual

Arjo

Arjo Stretcher Slings User manual

Arjo Ninjo User manual

Arjo

Arjo Ninjo User manual

Arjo Voyager User manual

Arjo

Arjo Voyager User manual

Arjo Sara Combilizer User manual

Arjo

Arjo Sara Combilizer User manual

Arjo Maxi 500 User manual

Arjo

Arjo Maxi 500 User manual

Arjo Sara 3000 Installation guide

Arjo

Arjo Sara 3000 Installation guide

Arjo MLAAS2000 User manual

Arjo

Arjo MLAAS2000 User manual

Arjo Enterprise ENT-ACC02 User manual

Arjo

Arjo Enterprise ENT-ACC02 User manual

Arjo Evenda EV-ACC12 User manual

Arjo

Arjo Evenda EV-ACC12 User manual

Arjo MAXI MOVE Operating instructions

Arjo

Arjo MAXI MOVE Operating instructions

Arjo Flowtron ACS900 User manual

Arjo

Arjo Flowtron ACS900 User manual

Arjo Evenda EV-ACC01 User manual

Arjo

Arjo Evenda EV-ACC01 User manual

Arjo MAA8000 User manual

Arjo

Arjo MAA8000 User manual

Arjo MAA2080M User manual

Arjo

Arjo MAA2080M User manual

Arjo Tempo Installation guide

Arjo

Arjo Tempo Installation guide

Popular Medical Equipment manuals by other brands

TekTone Tek-CARE160 Installation and operation manual

TekTone

TekTone Tek-CARE160 Installation and operation manual

NeuroMetrix Quell 2.0 user manual

NeuroMetrix

NeuroMetrix Quell 2.0 user manual

AMT XLR8 Quick reference guide

AMT

AMT XLR8 Quick reference guide

EDAN SONOTRAX Pro user manual

EDAN

EDAN SONOTRAX Pro user manual

Restorative Therapies RT300 Service guide

Restorative Therapies

Restorative Therapies RT300 Service guide

Gendex Expert DC installation manual

Gendex

Gendex Expert DC installation manual

Dexcowin ADX4000W user manual

Dexcowin

Dexcowin ADX4000W user manual

Libelium MySignals user manual

Libelium

Libelium MySignals user manual

Acelity V.A.C.ULTA 4 user manual

Acelity

Acelity V.A.C.ULTA 4 user manual

Caputron ActivaDose II tDCS quick start guide

Caputron

Caputron ActivaDose II tDCS quick start guide

Plinth 2000 93CDT Service manual

Plinth 2000

Plinth 2000 93CDT Service manual

GE SENOGRAPHE 800T Operator's manual

GE

GE SENOGRAPHE 800T Operator's manual

GE Definium 5000 Operator's manual

GE

GE Definium 5000 Operator's manual

Kanmed GE-1380 user manual

Kanmed

Kanmed GE-1380 user manual

Huntleigh FD1 Instructions for use

Huntleigh

Huntleigh FD1 Instructions for use

Stryker SPR Plus Operation manual

Stryker

Stryker SPR Plus Operation manual

Tobii Dynavox I-Series user manual

Tobii Dynavox

Tobii Dynavox I-Series user manual

S-Capepod Evac Cocoon Step-by-step guide

S-Capepod

S-Capepod Evac Cocoon Step-by-step guide

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

Assemble seat cushion and pump
Assemble mattress overlay or mattress replacement and pump
CPR unit is clicked into
closed position. Connect the tubeset.
Seat cushion:
Place on chair surface.
8VHWKH¿[LQJVWUDSVWRDWWDFK
3ODFHSXPSRQÀRRUFDEOHXQGHUFKDLU
WXEHVHWSODFHGDORQJVLGHFKDLU
Connect the tubeset.
Connect power cable to power source.
• FHOOVIDFLQJXS
• WXEHVHWDWIURQWULJKWFRUQHU
• FHOOVKRUL]RQWDODFURVVFKDLU
V-shape towards front
Front of chair
Back of chair
Zip the protective cover
over the mattress. Arjo
ORJRYLVLEOHDWWKHIRRW
end.
Auralis
2
Mattress overlay:
Place on top of base mattress.
6HFXUHZLWK¿[LQJVWUDSV
Mattress replacement:
Place on bed base. Attach the 8
VHFXULQJVWUDSVWRPRYLQJSDUWVRI
bed frame (+ 3 at head end for Auralis
Plus only)
• tubeset at foot end
• CPR at head end
• FHOOVIDFLQJXS
5
1
4
+DQJWKHSXPSDWWKH
foot end of the bed.
43
Place cable in the cable
PDQDJHPHQW. Close the
ÀDSDURXQGWKHFDEOHZLWK
the press studs.
Connect power cable to
power source.
6
1 2
$,(1B3DJH
QUICK REFERENCE GUIDE - USE
Auralis
10s
2s
$XWR¿UPPRGH
Activate: Press and
hold the button.
&RPIRUWLQGLFDWRUVÀDVK
DQGPDWWUHVVLQÀDWHVWR
$XWR¿UP
Extend: Press button
WRH[WHQGPLQXWHV
0D[PLQXWHV
,IQRWH[WHQGHGSXPS
JRHVEDFNWRSUHYLRXV
mode.
Deactivate: Press and
hold the button or select
another mode.
Pressure reached –
$XWR¿UPDQG&RQWURO
comfort indicators turn to
constant.
&35UDSLGGHÀDWLRQXQLW
Activate: Press both CPR release
buttons simultaneously. Reset: Press down the open part
until it clicks into closed position.
Make sure the front part is open.
7KHDLUHYDFXDWHVLQVHFRQGV
2s
Alternating mode, default setting
Activate:
3UHVVEXWWRQWKH$OWHUQDWLQJPRGHLQGLFDWRULVVKRZQ
$GMDFHQWFHOOVLQÀDWHDQGGHÀDWHRQDPLQXWHF\FOH
PLQ
Start the Auralis system
When the pump is connected to a power
source it runs a self check:
Beep – 10 seconds – 2 beeps – ready to use.
Press and hold Run/Standby button.
7KHIROORZLQJLQGLFDWRUVDUHVKRZQ
• Run/Standby
• Wait indicator
• $OWHUQDWLQJPRGHEXWWRQ
• Comfort control indicator
• %DWWHU\FKDUJHLQGLFDWRU
• Green indicators on the front of the pump
Once the Wait indicator turns
RIISODFHEHGVKHHWRQPDWWUHVV
Make sure that the CPR rapid
GHÀDWLRQXQLWLVFOHDUO\YLVLEOH
Place patient on the mattress or
seat cushion.
$OWHUQDWLQJPRGHLVVHWE\GHIDXOW
2
1
1
1
2
2
Auralis
Deactivate:
6HOHFW5HDFWLYH&/3RU$XWR¿UPPRGH
,IQRIXUWKHUWKHUDS\LVUHTXLUHGUHPRYHSDWLHQWIURP
the surface and turn off the pump.
$,(1B3DJH
2s
Deactivate:
Reconnect the tubeset. The SXPSJRHVEDFNWRWKH
previous mode.
Transport mode (mattresses only)
Reactive CLP mode
Activate:
Press and hold the button.
Reactive CLP mode indicator is shown.
Deactivate:
6HOHFW$OWHUQDWLQJPRGHRU$XWR¿UPPRGH
,IQRIXUWKHUWKHUDS\LVUHTXLUHGUHPRYHSDWLHQWIURP
the surface and turn off the pump.
Activate:
Press side buttons simultaneously and remove
tubeset.
The mattress supports the patient for up to 12 hours.
Lock out mode
Locking:
Press and hold the comfort control buttons
VLPXOWDQHRXVO\&RPIRUWFRQWUROLQGLFDWRUVZLOOÀDVK
Pump is now locked.
%ROVWHULQÀDWLRQDQGGHÀDWLRQ$XUDOLV3OXVRQO\
%ROVWHUGHÀDWLRQ
Locate the valve symbol (A). Turn the valve (B) on
the bolster fully clockwise.
/HDYHWRGHÀDWHIRUPLQXWHV
Unlocking:
Push and hold the comfort control buttons
VLPXOWDQHRXVO\&RPIRUWFRQWUROLQGLFDWRUVZLOOÀDVK
Pump is now unlocked.
%ROVWHULQÀDWLRQ
The bed frame should be in its widest form before
LQÀDWLQJWKHEROVWHUV/RFDWHWKHYDOYHV\PERO$
Turn the valve (B) on the bolsters fully anticlockwise.
/HDYHWRLQÀDWHIRUPLQXWHV
Risk of injury or discomfort
AA
BB
2s 2s
ArjoHuntleigh AB
Hans Michelsensgatan 10
211 20 Malmö, Sweden
www.arjo.com $,(1B3DJH