Screen 1 Adjustments Default Description
Mount: Push or Pull Push Side of opening operator is mounted on
Hold Open: 0 - 30 sec in 1 sec increments 4s Amount of time door will stay in full open position after an activation
Open Delay
(previously
Start Delay):
0 - 10 sec in 1 sec increments 0s Time before operator begins to open door. This is to allow accessories time to
function and not hinder the opening of the door.
Latch Rtrct: OFF, 3 - 45 sec in 5 sec
increments OFF Amount of time power is supplied to a latch retraction device.
Home: see Setting Open Position - Used to set the Home position and the Fully Open position of the door.
Vestibule: OFF, 5 - 30 sec in 5 sec
increments OFF Amount of delay for opening 2nd vestibule door
Push: OFF or PushNGo OFF Turn on or off Push N Go feature. If On, a slight push or pull of the door starts it
automatically opening.
Open Speed: 0 - 100% in 1% increments 120 How fast the door opens to the full open position.
Close Speed: 0 - 100% in 1% increments 80
How fast the motor returns to the home position. As Latch and Sweep on the
closer are adjusted, adjustments may be needed for Close Speed to assure
closer is not trying to backdrive the motor.
Errors: not adjustable - Error code seen by controller. See Page 14 for Controller Error Codes.
Screen 2 Adjustments Default Description
Door Feedback: not adjustable -General feedback. Includes Door State, Door Position, Motor Position, Open
Limit, Close Limit.
Drive Feedback: not adjustable -General feedback. Includes Bus Voltage, Bus Current, Frequency.
Usage: not adjustable -General feedback. Includes Open Time, Close Time, Days, Cycles, Firmware Rev.
Single: not functional - future Single not functional - for future
MastStopOffset: not functional - future 180 not functional - for future
PDET Option: On, Off Off On or Off for 585 Presence Detector
DT:
Standard, SS1:Stall,
SS1:Return Open, SS1:Stall /
Open
Stnd
Standard is Door Toggle. SS1 is for use of a Closing side door presence
detector. SS1:Stall - door stalls when obstruction is detected; SS1:Return Open
- door reopens when obstruction is detected; SS1:Stall/Open - door stalls
when obstruction is detected and then reopens when obstruction is removed.
A2:
Standard, SS2:Stall,
SS2:Return Home, SS2:Stall /
Home
Stnd
Standard is Activation mode - just like A1 activation. SS2 is for use of an
Opening side door presence detector. SS2:Stall - door stalls when obstruction
is detected; SS2:Return Home - door closes to home when obstruction is
detected; SS2:Stall/Home - door stalls when obstruction is detected and then
returns home when obstruction is removed.
Rly2: Alarm, Activation, On Opened,
On Closed Alarm
How Relay 2 is used: Alarm - used with above Alarm Delay; Activation - acts as
an additional NO/NC contact; On Opened - relay trips (closed contacts) when
door is in opened position; On Closed - relay trips (closed contacts) when
door reaches the fully closed position.
Alarm Delay: OFF, 30 sec, 60 sec OFF Used only for alarm accessories
Slow Speed: 0 - 100% in 1% increments 55 Speed up or slow down door during last few degrees of opening.
Hold Speed: 0 - 100% in 1% increments 55 Increase or decrease hold open force (when in “ON” position only, not “H/O”)
to compensate for spring force, wind conditions, etc.
Obst Delay: 0 - 5 sec in 1 sec increments 3s
Obstruction Delay: the amount of time the operator will push against an
obstruction before closing if during an opening cycle or reopening and trying
to close again if during a clocking cycle.